• Title/Summary/Keyword: Nuclear activity detection

Search Result 90, Processing Time 0.025 seconds

MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil (지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가)

  • Lee, Jun-Ho;Kim, Bong-Gi;Lee, Dong Myung;Byun, Jong-In
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • The detection performances of the NaI(Tl), $LaBr_3$(Ce) and $CeBr_3$ scintillation detectors, which can be used to rapidly evaluate the major artificial radionuclides deposited on the soil surface in a nuclear accident or radiological emergency, were compared. Detection performance was assessed by calculating the minimum detectable activity (MDA). The detection efficiency of each detector for artificial radionuclides was semi-empirically determined using mathematical modelling and point-like sources having certified radioactivity. The background gamma-ray energy spectrum for MDA evaluation was obtained from relatively wide and flat grassland, and the MDA values of each detector for the major artificial radionuclides that could be released in nuclear accidents were calculated. As a result, the relative MDA values of each detector regarding surface deposition distribution at normal environmental radiation level were evaluated as high in the order of the NaI(Tl), $LaBr_3$(Ce), and $CeBr_3$ detectors. These results were compared based on each detector's intrinsic and measurement environment background, detection efficiency, and energy resolution for the gamma-ray energy region of the radionuclide of interest.

Quantitative Comparison of Activity Calculation Methods for the Selection of Most Reliable Radionuclide Inventory Estimation

  • Hwang, Ki-Ha;Lee, Sang-Chul;Lee, Kun-Jai;Jeong, Chan-Woo;Ahn, Sang-Myeon;Kim, Tae-Wook;Kim, Kyoung-Doek;Herr, Y.H.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.322-327
    • /
    • 2003
  • It is important to know the accurate radionuclide inventory of radioactive waste for the reliable management. However, estimation of radionuclide concentrations in drummed radioactive waste is difficult and unreliable because of difficulties of direct detection, high cost, and radiation exposure of sampling personnel. In order to overcome these difficulties, scaling factors (SFs) have been used to assess the activities of radionuclides that could not be directly analyzed. A radionuclide assay system has been operated at KORI site since 1996 and consolidated scaling factor method has played a dominant role in determination of radionuclides concentrations. However, some problems are still remained such as uncertainty of estimated scaling factor values, inaccuracy of analyzed sample values, and disparity between the actual and ideal correlation pairs and the others. Therefore, it needs to improve the accuracy of scaling factor values. The scope of this paper is focused on the improvement of accuracy and representativeness of calculated scaling factor values based on statistical techniques. For the selection of reliable activity determination method, the accuracy of estimated SF values for each activity determination method is compared. From the comparison of each activity determination methods, it is recommended that SF determination method should be changed from the arithmetic mean to the geometrical mean for more reliable estimation of radionuclide activity. Arithmetic mean method and geometric mean method are compared based on the data set in KORI system.

  • PDF

Neuroactivation studies using Functional Brain MRI (기능적 자기공명영상을 이용한 뇌활성화 연구)

  • Chung, Kyung-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.1
    • /
    • pp.63-72
    • /
    • 2003
  • Functional MRI (fMRI) provides an indirect mapping of cerebral activity, based on the detection of the local blood flow and oxygenation changes following neuronal activity (Blood Oxygenation Level Dependent). fMRI allows us to study noninvasively the normal and pathological aspects of functional cortical organization. Each fMRI study compares two different states of activity. Echo-Planar Imaging is the technique that makes it possible to study the whole brain at a rapid pace. Activation maps are calculated from a statistical analysis of the local signal changes. fMRI is now becoming an essential tool in the neurofunctional evaluation of normal volunteers and many neurological patients as well as the reference method to image normal or pathologic functional brain organization.

Effect of Coincidence Gamma-ray Spectroscopy to the Reduction of Background Spectrum

  • Kim, Taewook;Changsoo Yoou;Chongmook park;Kim, Byungtae
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.464-469
    • /
    • 1998
  • A coincidence gamma-ray spectroscopy method was applied to reduce the background radioactivity for measuring the activity of radioisotopes in a sample in the presence of environmental natural radioactivity. A HPGe detector was used for the coincident spectrum as a main detector and a NaI(Tl) scintillation detector for gating purposes as an associated detector. For coincidence spectroscopy the whole energy spectrum of associated detector was used instead of gate signals. The coincident events obtained from the gating spectrum was evaluated by a coincidence computer program in this study instead of timing circuit. In this work, the background of detection environment was reduced to factor 100 and peaks to be determined was reduced to factor 30 using the coincidence gamma-ray spectroscopy.

  • PDF

Special monitoring results for determination of radionuclide composition of Russian NPP atmospheric releases

  • Vasyanovich, Maxim;Vasilyev, Aleksey;Ekidin, Aleksey;Kapustin, Ivan;Kryshev, Alexander
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1176-1179
    • /
    • 2019
  • Measurements of activity concentrations of radionuclides in atmospheric releases were performed in 2017-2018 at vent stacks of seven Russian nuclear power plants. The selected instruments and research methods, with detection limits significantly lower than the existing detection limit of Russian NPPs routine control, allowed to reliably determine up to 26 radionuclides. Analysis of experimental data allows to determine the list of radionuclides for calculation the effective dose rates to public and the permissible annual discharge levels for each Russian NPP. Radiocarbon is determined as major contributor for the dose from the atmospheric releases of LWGR reactors - up to 98% for EGP-6 and RBMK-1000 (Smolensk NPP) reactors. For PWR reactors (VVER) radionuclides contribution to the annual dose from atmospheric releases is more complicated, but, in general, dose is formed by tritium, $^{14}C$ and noble gases. The special monitoring results with ranking of measured radionuclides according to their contribution to the effective dose makes it possible to optimize the list of controlled radionuclides in airborne releases of Russian NPPs from 94 to 8-16 for different NPPs.

Improvement of the Biosensor for Detection of Endocrine Disruptors by Combination of Human Estrogen Receptorα and Co-Activator (Human Estrogen Receptor α와 Co-activator로 구성된 바이오센서를 이용한 내분비계장애물질의 검출)

  • Lee, Haeng-Seog
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.893-904
    • /
    • 2006
  • To improve sensitivity of biosensor as yeast two-hybrid detection system for estrogenic activity of suspected chemicals, we tested effects of several combinations of the bait and fish components in the two-hybrid system on Saccharomyces cerevisiae inducted a chromosome-integrated lacZ reporter gene that was under the control of CYC1 promoter and the upstream Gal4p-binding element $UAS_{GAL}$. The bait components that were fused with the Gal4p DNA binding domain are full-length human estrogen receptor ${\alpha}$ and its ligand-binding domain. The fish components that were fused with the Gal4p transcriptional activation domain were nuclear receptor-binding domains of co-activators SRC1 and TIF2. We found that the combination of the full-length human estrogen receptor ${\alpha}$ with the nuclear receptor-binding domain of co-activator SRC1 was most effective for the estrogen-dependent induction of reporter activity among the two-hybrid systems so far reported. The relative strength of transcriptional activation by representative natural and xenobiotic chemicals was well correlated with their estrogenic potency that had been reported with other assay systems.

Source and LVis based coincidence summing correction in HPGe gamma-ray spectrometry

  • Lee, Jieun;Kim, HyoJin;Kye, Yong Uk;Lee, Dong Yeon;Kim, Jeung Kee;Jo, Wol Soon;Kang, Yeong-Rok
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1754-1759
    • /
    • 2022
  • The activity of gamma-ray emitting nuclides is calculated assuming that each gamma-ray is detected individually; thus, the magnitude of the coincidence summing signal must be considered during activity calculations. Here, the correction factor for the coincidence summing effect was calculated, and the detection efficiencies of two HPGe detectors were compared. The CANBERRA Inc. GC4018 high-purity Ge detector provided an estimate for the peak-to-total ratio using a point source to determine the coincidence summing correction factor. The ORTEC Inc. GEM60 high-purity Ge detector uses EFFTRAN in LVis to obtain the parameters of the detector and source model and the gamma-gamma and gamma-X match estimates, in order to determine the coincidence summing correction factor. Nuclide analyses, radioactivity comparisons, and analyses of reference material samples were performed utilizing certified reference materials to accurately determine the detection efficiencies. For both Co-60 and Y-88, the detection efficiency for a point source increased by an average of at least 12-13%, whereas the detection efficiency determined using LVis increased by an average of at least 13-15%. The calculated radioactivity values of the certified reference material and reference material samples were accurate to within 3% and 6% of the measured values, respectively.

Detection of Occult Thymoma Using Tc-99m tetrofosmin Scintigraphy (Tc-99m tetrofosmin 신티그래피로 우연히 발견된 흉선암종)

  • Kwon, Seong-Young;Jeong, Shin-Young;Seo, Young-Soon;Ha, Jung-Min;Chong, A-Ri;Oh, Jong-Ryool;Song, Ho-Chun;Min, Jung-Joon;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.259-260
    • /
    • 2008
  • Tetrofosmin is a ligand that forms a lipophilic, cationic complex with Tc-99m. Tc-99m tetrofosmin was developed as a myocardial perfusion imaging agent and also used to depict tumors. Mediastinal tumors is also detected by Tc-99m tetrofosmin. We report a case of extracardiac mediastinal activity detected by Tc-99m tetrofosmin scintigraphy, which revealed thymoma.

Thyroiditis: Radioisotope Scan Findings and Clinical Significance (갑상선염의 방사선동위원소 검사소견 및 임상적의의)

  • Kim, Jong-Chae;Han, Duck-Sup;Park, Jung-Suck;Kim, Se-Jong;Park, Byung-Lan;Kim, Byoung-Geun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.280-285
    • /
    • 1991
  • We analyzed Radioisotope scan findings of 46 patients of thyroiditis which were proven pathologically at K.C.H. The results were as follows 1) 45 patients were female, one was male and average age of patients was 37 years old. 2) The lesion site was predominant in both lobe (67%) 3) Hashimoto's thyroiditis showed enlarged thyroid (85%) with cold nodule (20%), diffuse decreased activity (10%), while subacute thyroiditis was presented absent activity (53%), poor visualization (20%) or cold nodule (7%) 4) Radioisotope scan was valuable in evaluations function of thyroid gland and detection of lesion but there was a limit of pathological nature.

  • PDF

Development of Anticosmic Shielded Ultra Low Background Gamma Spectrometer for Precise Measurement of Environmental Radioactivity

  • Byun, Jong-In;Park, Yun-Ho;Kwak, Seung-Im;Hwang, Han-Yull;Chung, Kun-Ho;Park, Gun-Sik;Park, Doo-Won;Lee, Chnag-Woo
    • Nuclear Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.545-552
    • /
    • 2002
  • We developed an ultra low background gamma ray spectrometer particularly suitable for experiment which require lower detection limit. The background of a germanium spectrometer is suppressed by applying active and passive shielding technique at the same time. The active shielding devices consist of plastic scintillating plates of 50 mm thick and anti-coincidence electronic system. The shielding is made of 150 mm thick walls of very low activity lead,20 mm with activity of <10 Bq/kg and 130 mm with activity of <50 Bq/kg. The observed background count rates are 1.2 $s^{-1}$ and 0.36 $s^{-1}$ without and with the active shielding, respectively, overall the energy regions from 30 keV to 3 MeV The cosmic ray induced background is suppressed by a rate of 0.8 $s^{-1}$ at the present work. The detection efficiency curve necessary to obtain the radioactivity of environmental samples has been precisely determined on the energy regions from 80 to 2000 keV with a 10$^3$ ml marinelli beaker sample, consisting of the calibrated radionuclides $^{109}$ Cd, $^{57}$ CO, $^{139}$ Ce, $^{203}$ Hg, $^{113}$ Sn, $^{85}$Sr, $^{137}$ Cs, $^{60}$ Co and $^{88}$ Y. Virtues Of the method are demonstrated by measuring the activity of $^{137}$ Cs contained in the powdered milk.