• Title/Summary/Keyword: Nuclear Program

Search Result 1,194, Processing Time 0.03 seconds

Evaluation of Liver Function Using $^{99m}-Lactosylated$ Serum Albumin Liver Scintigraphy in Rat with Acute Hepatic Injury Induced by Dimethylnitrosamine (Dimethylnitrosamine 유발 급성 간 손상 흰쥐에서 $^{99m}-Lactosylated$ Serum Albumin을 이용한 간 기능의 평가)

  • Jeong, Shin-Young;Seo, Myung-Rang;Yoo, Jeong-Ah;Bae, Jin-Ho;Ahn, Byeong-Cheol;Hwang, Jae-Seok;Jeong, Jae-Min;Ha, Jeong-Hee;Lee, Kyu-Bo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.418-427
    • /
    • 2003
  • Objects: $^{99m}-lactosylated$ human serum albumin (LSA) is a newly synthesized radiopharmaceutical that binds to asialoglycoprotein receptors, which are specifically presented on the hepatocyte membrane. Hepatic uptake and blood clearance of LSA were evaluated in rat with acute hepatic injury induced by dimethylnitrosamine (DMN) and results were compared with corresponding findings of liver enzyme profile and these of histologic changes. Materials and Methods: DMN (27 mg/kg) was injected intraperitoneally in Sprague-Dawley rat to induce acute hepatic injury. At 3(DMN-3), 8(DMN-8), and 21 (DMN-21) days after injection of DMN, LSA injected intravenously, and dynamic images of the liver and heart were recorded for 30 minutes. Time-activity curves of the heart and liver were generated from regions of interest drawn over liver and heart area. Degree of hepatic uptake and blood clearance of LSA were evaluated with visual interpretation and semiquantitative analysis using parameters (receptor index : LHL3 and index of blood clearance : HH3), analysis of time-activity curve was also performed with curve fitting using Prism program. Results: Visual assessment of LSA images revealed decreased hepatic uptake in DMN treated rat, compared to control group. In semiquantitative analysis, LHL3 was significantly lower in DMN treated rat group than control rat group (DMN-3: 0.842, DMN-8: 0.898, DMN-21: 0.91, Control: 0.96, p<0.05), whereas HH3 was significantly higher than control rat group (DMN-3: 0.731,.DMN-8: 0.654, DMN-21: 0.604, Control: 0.473, p<0.05). AST and ALT were significantly higher in DMN-3 group than those of control group. Centrilobular necrosis and infiltration of inflammatory cells were most prominent in DMN-3 group, and were decreased over time. Conclusion: The degree of hepatic uptake of LSA was inversely correlated with liver transaminase and degree of histologic liver injury in rat with acute hepatic injury.

Development of Evaluation Method of Regional Contractility of Left Ventricle Using Gated Myocardial SPECT and Assessment of Reproducibility (게이트 심근 SPECT를 이용한 좌심실의 국소탄성률 평가방법 개발 및 재현성 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Kang, Won-Jun;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.355-363
    • /
    • 2003
  • Purpose: Regional contractility can be calculated using the regional volume change of left ventricle measured by gated myocardial SPECT image and curve of central artery pressure obtained from radial artery pressure data. In this study, a program to obtain the regional contractility was developed, and reproducibility of regional contractility measurement was assessed. Materials and Methods: Seven patients(male:female=5:2, $58{\pm}11.9$ years) with coronary artery diseases underwent gated Tc-99m MIBI myocardial SPECT twice without delay between two scans. Regional volume change of left ventricle was estimated using CSA (Cardiac SPECT Analyzer) software developed in this study. Regional contractility was iteratively estimated from the time-elastance curve obtained using the time-pressure curve and regional time-volume curve. Reproducibility of regional contractility measurement assessed by comparing the contractility values measured twice from the same SPECT data and by comparing those measured from the pair of SPECT data obtained from a same patient. Results: Measured regional contractility was $3.36{\pm}3.38{mm}Hg/mL$ using 15-segment model, $3.16{\pm}2.25{mm}Hg/mL$ using 7-segment model, and $3.11{\pm}2.57{mm}Hg/mL$ using 5-segment model. The harmonic average of regional contractility value was almost identical to the global contractility. Correlation coefficient of regional contractility values measured twice from the same data was greater than 0.97 for all models, and two standard deviations of contractility difference on Bland Altman plot were 1.5%, 1.0%, and 0.9% for 15-, 7-, and 5-segment models, respectively. Correlation coefficient of regional contractility values measured from the pair of SPECT data obtained from a same patient was greater than 0.95 for all models, and two standard deviations on Bland Altman plot were 2.2%, 1.0%, and 1.2%. Conclusion: Regional contractility of left ventricle measured using developed software in this study was reproducible. Regional contractility of left ventricle will be a new useful index for myocardial function after analysis of the clinical data.

Correlation of SUV According to the Body Weight and Body Surface Area in PET/CT Imaging (PET/CT 검사 시 체중과 체표면적에 따른 SUV의 상관관계)

  • Park, Ju-Seon;Do, Yong-Ho;Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.44-47
    • /
    • 2013
  • Purpose: There are several methods of measuring SUV in PET/CT imaging including $SUV_{bw}$ which uses the body weight, $SUV_{bsa}$ which that uses body surface area and $SUV_{lbm}$ which uses lean body mass. Currently, Seoul National University Hospital uses $SUV_{bw}$ method which minimizes the variability. In this study, we compared and analyzed the correlation between $SUV_{bw}$ and $SUV_{bsa}$ according to patients' body mass index. Materials and Methods: Using Biograph mCT40 (Siemens, Germany), we conducted $^{18}F-FDG$ PET/CT imaging on 70 patients (41 males, 29 females; ages $58.04{\pm}12.44$). We classified the patients as underweight (BMI<20), normal weight (20$${\leq_-}$$BMI<25), overweight (25$${\leq_-}$$BMI<30), obese (30$${\leq_-}$$BMI<35) and severely obese (35$${\leq_-}$$BMI) according to the patient's sex, age and BIM. Then, bone, liver and lungs were set as ROI for calculation of maximum values of $SUV_{bw}$ and $SUV_{bsa}$, through Syngo.via VA11A analysis program. Results: Comparing the five groups divided according to the BMI by the standard differences between $SUV_{bw}$ to $SUV_{bsa}$, $SUV_{max}$ was measured to be $0.66{\pm}0.15$, $0.78{\pm}0.35$, $0.77{\pm}0.21$, $1.00{\pm}0.44$, $1.53{\pm}0.38$ for bones in underweight, normal weight, overweight, obese and severely obese groups, respectively. For liver, values of $SUV_{max}$ were $1.64{\pm}0.16$, $2.06{\pm}0.34$, $2.19{\pm}0.21$, $2.52{\pm}0.21$ and $2.74{\pm}0.40$ in the same order. And for lung, values of $SUV_{max}$ were $0.69{\pm}0.33$, $0.54{\pm}0.17$, $0.62{\pm}0.23$, $0.83{\pm0.29}$, $1.03{\pm}0.30$. Conclusion: By comparing and analyzing the differences between $SUV_{bw}$ and $SUV_{bsa}$ in this study, it was found that the differences between $SUV_{bw}$ and $SUV_{bsa}$ increased as patient's BMI increased. Thus, there is room for error in the values of SUV depending on the methods of calculations, and appropriate methods must be applied according to the circumstances in clinical settings.

  • PDF

Evaluation of Image Quality Using CT Attenuation Correction in SPECT/CT (SPECT/CT에서 CT감쇠보정에 따른 영상의 질 평가)

  • Cho, Sung Wook;Kim, Gye Hwan;Sung, Yong Joon;Lee, Hyung Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.78-83
    • /
    • 2013
  • Purpose: SPECT/CT, a combination of SPECT and CT, is capable of expressing the results of attenuation correction on images biased by automatic program. As a result, this research evaluates the usefulness of images with CT attenuation correction, using various phantoms and images of patients. Materials and Methods: From July of 2012 to September of 2012, this research was conducted on the contrast, spatial resolution, and images of patients. We studied the contrast with IEC body phantom and Jaszczak phantom, while the spatial resolution was evaluated with NEMA triple line phantom. Further, a comparative study was carried out on the quality of the images, on the difference between the images before and after the CT attenuation correction. Results: Compared the differences between the contrast before and after the CT attenuation correction in IEC body phantom. The contrast was improved by 33.6% at minimum, 89.8% at maximum. In case of Jaszczak Phantom, the contrast was enhanced by 9.9% at minimum, 27.8% at maximum. In NEMA Triple line phantom, the resolution was raised by 4.5% in average: 4.4% in horizontal, 4.5% in vertical. In Anthropomorphic Torso Phantom, the perfusion score of the interior wall with the most severe attenuation was measured to be 29.4%. In the experiment carried out on myocardial perfusion SPECT/CT patients, 9% improvement was discovered in the interior wall, where the most dramatic attenuation occurred, after the CT attenuation correction. Conclusion: SPECT/CT proved its clinical usefulness by enabling the acquisition of images with enhanced contrast and spatial resolution compare to the ones resulted from SPECT.

  • PDF

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

Usability Research of Onco Flash in SPECT (SPECT 검사에서 Onco Flash의 유용성과 질적 향상 평가)

  • Noh, Ik-Sang;Cha, Eun-Sun;Kim, Ki;Choi, Choon-Ki;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.3-8
    • /
    • 2009
  • Purpose: Onco flash shortens a scan time with half and there is a possibility of getting the data which corresponds in existing. The experiment which makes the image whose Onco Flash is excellent OSEM tried, as changes parameter of time, iteration. After reconstituting an image, produces FWHM and executes an evaluation. Materials and Methods: Siemens e.cam gamma camera, standard Jaszczak phantom and spatial resolution phantom was used. In order for the bubble not to enter, implants 2 mCi and volume 0.25 cc $^{99m}Tc$ respectively in line 3 to spatial resolution phantom. Put on that phantom on the table correctly, and acquires an image. 15 mCi putting in distilled water to mix $^{99m}Tc$ well in Jaszczak phantom and acquires image just like spatial resolution phantom. Reconstructs and converts the image to digital image as Sante program. Produce FWHM and evaluate by Amide. Results: The non-scattered image shows better FWHM value than scattered image. As time increases from 10 sec to 30 sec for 5sec interval, FWHM appeared to 30.1, 28.5, 24.5, 23.6, 23.4 mm. At the standard iteration value 4, OSEM FWHM shows 8.0 mm, and Onco Flash is 8.1 mm. As fade in iteration, FWHM value more and more decreased. Conclusion: When using Onco Flash, shortens a scan time, and enhances image quality. Also, user can adjust the parameters to improve resolution. Therefore, patient and user are satisfied with these merits.

  • PDF

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Functional Brain Mapping Using $H_2^{15}O$ Positron Emission Tomography ( II ): Mapping of Human Working Memory ($H_2^{15}O$ 양전자단층촬영술을 이용한 뇌기능 지도 작성(II): 작업 기억의 지도 작성)

  • Lee, Jae-Sung;Lee, Dong-Soo;Lee, Sang-Kun;Nam, Hyun-Woo;Kim, Seok-Ki;Park, Kwang-Suk;Jeong, Jae-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.238-249
    • /
    • 1998
  • Purpose: To localize and compare the neural basis of verbal and visual human working memory, we performed functional activation study using $H_2^{15}O$ PET. Materials and Methods: Repeated $H_2^{15}O$ PET scans with one control and three different activation tasks were performed on six right-handed normal volunteers. Each activation task was composed of 13 match-ing trials. On each trial, four targets, a fixation dot and a probe were presented sequentially and subject's task was to press a response button to indicate whether or not the probe was one of the previous targets. Short meaningful Korean words, simple drawings and monochromic pictures of human faces were used as matching objects for verbal or visual memory. All the images were spatially normalized and the differences between control and activation states were statistically analyzed using SPM96. Results: Statistical analysis of verbal memory activation with short words showed activation in the left Broca's area, promoter cortex, cerebellum and right cingulate gyrus. In verbal memory with simple drawings, activation was shown in the larger regions including where activated with short words and left superior temporal cortex, basal ganglia, thalamus, prefrontal cortex, anterior portion of right superior temporal gyrus and right infero-lateral frontal cortex. On the other hand, the visual memory task activated predominantly right-sided structures, especially inferior frontal cortex, supplementary motor cortex and superior parietal cortex. Conclusion: The results are consistent with the hypothesis of the laterality and dissociation of the verbal and visual working memory from the invasive electrophysiological studies and emphasize the pivotal role of frontal cortex and cingulate gyrus in working memory system.

  • PDF

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

Clinical Study of Simultaneous Acquisition Rest 99mTc-sestaMIBI/Stress 201Tl Dual-Isotope Myocardial Perfusion Imaging with a Solid-State Dedicated Cardiac Gamma Camera (반도체 심근 전용 감마카메라를 이용한 Rest 99mTc-sestaMIBI/Stress201Tl 이중 동위원소 심근 관류 동시 스캔에 관한 임상적 고찰)

  • Bahn, Young-Kag;Kim, Dong-Heui;Choi, Yong-Hoon;Kang, Chun-Koo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.88-91
    • /
    • 2018
  • Purpose The purpose of this study is to investigate the simultaneous dual isotope (SDI) myocardial perfusion scan that can be performed in a short time using a semiconductor gamma camera. Materials and Methods Of the 86 patients who underwent Rest/Stress $^{99m}TC$-sestaMIBI 1-day myocardial perfusion scan and Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope myocardial perfusion scan using a heart-only gamma camera, the test results were the same, 36 patients who did not show any change in the clinical outcome. Quantitative values were statistically analyzed using a QPS program to confirm the correlation between the images of the two examinations. Results Rest/Stress $^{99m}TC$-sestaMIBI simultaneous dual myocardial perfusion scans and $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ double-isotope myocardial perfusion scans were analyzed for Summed score. The $R^2$ value of the Rest summed score (RSS) was 0.91 and the $R^2$ value of the stress summed score (SSS) was 0.71. Conclusion The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan confirmed its correlation with the previous day's test. The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan can be completed in approximately 30minutes. It maybe clinically useful for patients who need short examination time such as emergency patients or elderly patients.