• Title/Summary/Keyword: Nuclear Program

Search Result 1,192, Processing Time 0.031 seconds

A Numerical Technique for Predicting Deformation due to Neutron Irradiation for Integrity Assessment of Research Reactors (연구용 원자로의 건전성 평가를 위한 수치해석적 중성자 조사 재료변형 예측기법 개발)

  • Jun-Geun Park;Tae-Hyeon Seok;Nam-Su Huh
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.20 no.1
    • /
    • pp.39-48
    • /
    • 2024
  • Research reactors are operated under ambient temperature and atmospheric pressure, which is much less severe conditions compared to those in typical nuclear power plants. Due to the high temperature, heat resistant materials such as austenite stainless steel should be used for the reactors in typical nuclear power plants. Whereas, as the effect of temperature is low for research reactors, materials with high resistance to neutron irradiation, such as zircaloy and beryllium, are used. Therefore, these conditions should be considered when performing integrity assessment for research reactors. In this study, a computational technique through finite element (FE) analysis was developed considering the operating conditions and materials of research reactor when conducting integrity assessment. Neutron irradiation analysis techniques using thermal expansion analysis were proposed to consider neutron irradiation growth and swelling in zirconium alloys and beryllium. A user subroutine program that can calculate the strain rate induced by neutron irradiation creep was developed for use in the commercial analysis program Abaqus. To validate the proposed technique and the user subroutine, FE analysis results were compared with hand-calculation results, and showed good agreement. Consequently, developed technique and user subroutine are suitable for evaluating structural integrity of research reactors.

Quantitative Assessment of Obstructive Uropathy with Diuretic Renography in Children (소아 폐쇄성 요로질환에서 이뇨 신 신티그라피의 정량적 분석)

  • Kim, Jong-Ho;Lee, Dong-Soo;Kwark, Cheol-Eun;Lee, Kyung-Han;Choi, Chang-Woon;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Choi, Yong;Choi, Hwang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.239-247
    • /
    • 1993
  • Differentiating the various causes of hydronephrosis from that of obstruction can be very difficult. The decision-making process for those instances of urinary tract dilatation that require surgical correction and those that do not is based in part on the findings of diuresis renography. The methodology for performing this test has differed among nuclear medicine practitioners and the surgical findings are occasionally discrepant from the diuretic renogram interpretation. Consequently we made an automatic computer software program that calculates the slope of the response curve. The quantitative indices, such as the injection and response t1/2 by linear-fitting and monoexponential-fitting, were compared with the visual assessment of the diuretic cinerenography and clinical outcome in 50 children (62 kidneys) with ureteropelvic junction obstruction. Pooled diuresis renogram data indicated that: (1) Visual evaluation of the diuretic cinerenography is a sensitive (87%, 54/62) tool to differentiate obstruction in suspected ureteropelvic junction obstruction. (2) The cut-off value (maximum washout t1/2 with non-obstruction) of injection and response t1/2 by linear-fitting were 40 min. (3) The sensitivity and specificity using injection and response t1/2 by linear-fitting for obstruction were 89%(23/26) and 100%(30/30), respectively. (4) Response t1/2 as well as injection t1/2 by monoexponential-fitting do not stratify children with possible ureteropelivic junction obstruction. In conclusion, quantitative assessment of diuretic renography as well as visual assessment of diuretic cinerenography correlate well with surgical and clinical outcome of suspected ureteropelvic junction obstruction.

  • PDF

Development of Program Evaluating the Effects on the Secondary Side of Nuclear Power Plant of Steam Generator due to Foreign Objects (원자력발전소 증기발생기 2차측 Free-Span 잔류물질 영향평가 전산 프로그램 개발)

  • Yu, Hyeon-Ju
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.26-28
    • /
    • 2006
  • When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. Considering the wear and impact by the foreign materials, KEPRI(Korea Electric Power Research Institute) developed the methodology to evaluate the foreign materials analytically. This methodology was described with a computer program in order to obtain the fast results. The program informs whether the tubes have the structural integrity when the foreign material strikes the tubes. Moreover, this gives us the remaining life of the steam generator tubes. In this paper, the program, which evaluates the effects of the foreign objects in the secondary side of steam generator, is introduced.

  • PDF

Direct radio-iodination of folic acid for targeting folate receptor-positive tumors

  • Huynh, Phuong Tu;Lee, Woonghee;Ha, Yeong Su;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.1
    • /
    • pp.3-10
    • /
    • 2018
  • The folate receptor (FR) is a promising cell membrane-associated target for nuclear imaging of various cancers (via imaging $FR-{\alpha}$) and potentially also inflammatory diseases (via imaging $FR-{\beta}$), through the use of folic acid-based radioconjugates. However, there have been several drawbacks of previously reported radioconjugates, such as a short half-life of the radiolabel ($^{68}Ga\;t_{1/2}$ 68 min), a complex and time-consuming multistep radiosynthesis, and a high renal uptake of radiolabeled folate derivatives. The goal of this study was to develop an imaging probe by directly labeling folate with radioactive iodine without using an extra prosthetic group. The radiolabeling of folate was optimized using various labeling conditions and the labeled tracers were isolated by high-performance liquid chromatography. The in vitro stability of labeled folate was checked in phosphate-buffered saline and serum. The tumor-targeting efficacy of the probe was also evaluated by biodistribution studies using a murine 4T1 tumor model.

A Study on the Marital Satisfaction and Needs of Education for Elder Couples - Centered the Mid-Later Life - (결혼만족도와 노년기부부교육요구에 관한 연구 - 중.노년기를 중심으로 -)

  • Hong, Dal-Ah-Gi;Lee, Nam-Joo
    • Korean Journal of Human Ecology
    • /
    • v.14 no.6
    • /
    • pp.883-898
    • /
    • 2005
  • This study was to find out the demand for the education of elder marital couples to improve their relationship. The results of this study were as follows. 1. Marital satisfaction was affected by four elements such as confidence and affinity, mutual respect, communication, and cohesion. Each element showed significant differences by the socio-demographic variables. Out of these variables, age, academic career, health, occupation, and salary showed significant difference in all 4 elements affecting the marital satisfaction. 2. The couples with shorter marriage period, with religion, and belonging to a nuclear family, and doing social activities were recognized the necessity of education highly. 3. The higher the confidence and affinity, and cohesion between couple, the higher the demand for education program. The lower the score of communication between couple, they participated more often in the educational program. For the improvement of confidence and affinity between couple, the educational program with partners is necessary.

  • PDF

A Current Status of Natural Analogues Programs in Nations Considering High-Level Radioactive Waste Disposal

  • HunSuk Im;Dawoon Jeong;Min-Hoon Baik;Ji-Hun Ryu
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.1
    • /
    • pp.65-93
    • /
    • 2023
  • Several countries have been operating radioactive waste disposal (RWD) programs to construct their own repositories and have used natural analogues (NA) studies directly or indirectly to ensure the reliability of the long-term safety of deep geological disposal (DGD) systems. A DGD system in Korea has been under development, and for this purpose a generic NA study is necessary. The Korea Atomic Energy Research Institute has just launched the first national NA R&D program in Korea to identify the role of NA studies and to support the safety case in the RWD program. In this article, we review some cases of NA studies carried out in advanced countries considering crystalline rocks as candidate host rocks for high-level radioactive waste disposal. We examine the differences among these case studies and their roles in reflecting each country's disposal repository design. The legal basis and roadmap for NA studies in each country are also described. However because the results of this analysis depend upon different environmental conditions, they can be only used as important data for establishing various research strategies to strengthen the NA study environment for domestic disposal system research in Korea.

Study on Dose Rate on the Surface of Cask Packed with Activated Cut-off Pieces from Decommissioned Nuclear Power Plant

  • Park, Kwang Soo;Kim, Hae Woong;Sohn, Hee Dong;Kim, Nam Kyun;Lee, Chung Kyu;Lee, Yun;Lee, Ji Hoon;Hwang, Young Hwan;Lee, Mi Hyun;Lee, Dong Kyu;Jung, Duk Woon
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.4
    • /
    • pp.178-186
    • /
    • 2020
  • Background: Reactor pressure vessel (RV) with internals (RVI) are activated structures by neutron irradiation and volume contaminated wastes. Thus, to develop safe and optimized disposal plan for them at a disposal site, it is important to perform exact activation calculation and evaluate the dose rate on the surface of casks which contain cut-off pieces. Materials and Methods: RV and RVI are subjected to neutron activation calculation via Monte Carlo methodology with MCNP6 and ORIGEN-S program-neutron flux, isotopic specific activity, and gamma spectrum calculation on each component of RV and RVI, and dose rate evaluation with MCNP6. Results and Discussion: Through neutron activation analysis, dose rate is evaluated for the casks containing cut-off pieces produced from decommissioned RV and RVI. For RV cut-off ones, the highest value of dose rate on the surface of cask is 6.97 × 10-1 mSv/hr and 2 m from it is 3.03 × 10-2 mSv/hr. For RVI cut-off ones, on the surface of it is 0.166 × 10-1 mSv/hr and 2 m from it is 1.04 × 10-1 mSv/hr. Dose rates for various RV and RVI cut-off pieces distributed lower than the limit except the one of 2 m from the cask surface of RVI. It needs to adjust contents in cask which carries highly radioactive components in order to decrease thickness of cask. Conclusion: Two types of casks are considered in this paper: box type for very-low-level waste (VLLW) as well as low-level waste (LLW) and cylinder type for intermediate-level waste (ILW). The results will contribute to the development of optimal loading plans for RV and RVI cut-off pieces during the decommissioning of nuclear power plant that can be used to prepare radioactive waste disposal plans for the different types of wastes-ILW, LLW, and VLLW.

Application of peak based-Bayesian statistical method for isotope identification and categorization of depleted, natural and low enriched uranium measured by LaBr3:Ce scintillation detector

  • Haluk Yucel;Selin Saatci Tuzuner;Charles Massey
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3913-3923
    • /
    • 2023
  • Todays, medium energy resolution detectors are preferably used in radioisotope identification devices(RID) in nuclear and radioactive material categorization. However, there is still a need to develop or enhance « automated identifiers » for the useful RID algorithms. To decide whether any material is SNM or NORM, a key parameter is the better energy resolution of the detector. Although masking, shielding and gain shift/stabilization and other affecting parameters on site are also important for successful operations, the suitability of the RID algorithm is also a critical point to enhance the identification reliability while extracting the features from the spectral analysis. In this study, a RID algorithm based on Bayesian statistical method has been modified for medium energy resolution detectors and applied to the uranium gamma-ray spectra taken by a LaBr3:Ce detector. The present Bayesian RID algorithm covers up to 2000 keV energy range. It uses the peak centroids, the peak areas from the measured gamma-ray spectra. The extraction features are derived from the peak-based Bayesian classifiers to estimate a posterior probability for each isotope in the ANSI library. The program operations were tested under a MATLAB platform. The present peak based Bayesian RID algorithm was validated by using single isotopes(241Am, 57Co, 137Cs, 54Mn, 60Co), and then applied to five standard nuclear materials(0.32-4.51% at.235U), as well as natural U- and Th-ores. The ID performance of the RID algorithm was quantified in terms of F-score for each isotope. The posterior probability is calculated to be 54.5-74.4% for 238U and 4.7-10.5% for 235U in EC-NRM171 uranium materials. For the case of the more complex gamma-ray spectra from CRMs, the total scoring (ST) method was preferred for its ID performance evaluation. It was shown that the present peak based Bayesian RID algorithm can be applied to identify 235U and 238U isotopes in LEU or natural U-Th samples if a medium energy resolution detector is was in the measurements.

Analysis of Quantitative Indices in Tl-201 Myocardial Perfusion SPECT: Comparison of 4DM, QPS, and ECT Program (Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석)

  • Lee, Dong-Hun;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.67-75
    • /
    • 2009
  • Purpose: As to the analytical method of data, the various programs in which it is used for the quantitative rating of the Tl-201 myocardial perfusion SPECT are reported that there is a difference. Therefore, the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made against data of the same patient. Using quantitative index that able to represent myocardial perfusion defect level, we aimed to determine correlation among three myocardial perfusion analysis programs 4DM (4DMSPECT), QPS (Quantitative Perfusion SPECT), ECT (Emory Cardiac Toolbox) that be used generally in most departments of Nuclear Medicine. Materials and Methods: We analyzed the 145 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Mediacal Center from December 1th 2008 to February 14th 2008. We sorted as normal group and abnormal group. Normal group consist of 80 patients (Male/Female=38/42, age:$65.1{\pm}9.9$) who have low possibility of cardiovascular disease. And abnormal group consist of 65 patients (Male/Female=45/20, age:$63.0{\pm}8.7$) who were diagnosed cardiovascular disease with reversible perfusion defect or fixed perfusion defect through myocardial perfusion SPECT results. Using the 4DM, QPS, and ECT programs, the total defect extent (TDE) such as LAD, LCX, RCA and the summed stress score (SSS) have been analysed for their correlations and statistical comparison with the paried t-test for the quantitative indices analysed from each group. Results: The correlation of 4DM:QPS, QPS:ECT, ECT:4DM each group result from 145 patients is 0.84, 0.86, 0.82 at SSS, 0.87, 0.84, 0.87 at TDE, and both index showed good correlation. In paired t-test and Bland-Altman analysis results showed no statistically significant difference in the comparison of QPS:ECT at the mean SSS and TDE, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index. The correlation of 4DM:QPS, QPS:ECT, ECT:4DM program results from abnormal group (65 patients) is 0.72, 0.72, 0.70 at SSS and 0.77, 0.70, 0.77 at TDE and TDE and SSS has a good correlation. In abnormal group, paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.89) and TDE (p=0.23) comparison, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). In normal group (80 patients), paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.95) and TDE (p=0.73) comparison. And 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). Conclusions: The perfusion defect of the Tl-201 myocardial perfusion SPECT was analyzed in not only the patient in whom it has the cardiovascular disease but also the patient in whom the possibility of the cardiovascular disease is few. In the comparison of the all group research, the mean of the TDE and SSS, 4DM was lower than QPS and ECT progrms. Each program showed good correlation and the results showed statistically significant difference. However, in this way, it is determined to be compatible about the analysis value in which the large-scale side between the programs uses each program a difference in a clinical in the Bland-Altman analyzed result in spite of the good correlation and cannot use. but, this analyzed result will be able to be usefully used as the reference material for the clinical read and is expected.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.