• 제목/요약/키워드: Nuclear Design

검색결과 3,130건 처리시간 0.027초

외압을 받는 두꺼운 원통형 내압용기의 붕괴하중 해석 (The Analysis of Collapse Load of Thick Pressure Cylinder under External Hydrostatic Pressure)

  • 이재환;박병재
    • 대한조선학회논문집
    • /
    • 제56권2호
    • /
    • pp.175-186
    • /
    • 2019
  • Number of studies on the buckling of thin cylindrical pressure vessels, such as submarine pressure hull and pipe with a large ratio of diameter/thickness, have been carried out in the naval and ocean engineering. However, research about thick cylinder pressure vessel has not been active except for the specific application in nuclear area. There are not many papers for the estimation of buckling and ultimate load capacity of thick cylinders for the deep sea usage. Thus, it is important to understand the theoretical bases of the buckling and collapse process and the derivation process of such loads for the proper design and structural analysis. The objective of this study is to survey the collapse behavior, to analyse and clarify the derivation procedure and to estimate the ultimate collapse load for thick cylinder by analyzing relevant books and papers. It is found that the yielding begins at the internal surface of the thick cylinder and plasticity develops from the internal surface to the external surface to generate collapse. Also the initial imperfection of cylinder develops flattening and consequently accelerates buckling and finally ultimate collapse. By comparing the collapse loads of aluminum thick cylinder by applying equations herein, it is shown that the equations analyzed are appropriate to obtain collapse load for thick cylinder.

초음속 증기제트의 충돌하중 특성에 대한 수치해석 연구 (Numerical Analysis on the Characteristics of Supersonic Steam Jet Impingement Load)

  • 오세홍;최대경;박원만;김원태;장윤석;최청열
    • 한국압력기기공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.1-10
    • /
    • 2018
  • Structures, systems and components of nuclear power plants should be able to maintain safety even in the event of design-basis accidents such as high-energy line breaks. The high-pressure steam jet ejected from the broken pipe may cause damage to the adjacent structures. The ANSI/ANS 58.2 code has been adopted as a technical standard for evaluating the jet impingement load. Recently, the U.S. NRC pointed out the non-conservativeness of the ANSI/ANS 58.2, because it does not take into account the blast wave effect, dynamic behavior of the jet, and oversimplifies the shape and load characteristics of the supersonic steam jet. Therefore, it is necessary to improve the evaluation method for the high-energy line break accident. In order to evaluate the behavior of supersonic steam jet, an appropriate numerical analysis technique considering compressible flow effect is needed. In this study, numerical analysis methodology for evaluating supersonic jet impingement load was developed and verified. In addition, the conservativeness of the ANSI/ANS 58.2 model was investigated using the numerical analysis methodology. It is estimated that the ANSI jet model does not sufficiently reflect the physical behavior of under-expanded supersonic steam jet and evaluates the jet impingement load lower than CFD analysis result at certain positions.

Seismic pounding between adjacent buildings considering soil-structure interaction

  • Raheem, Shehata E Abdel;Alazrak, Tarek M.A.;AbdelShafy, Aly G.A.;Ahmed, Mohamed M.;Gamal, Yasser A.S.
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.55-70
    • /
    • 2021
  • In urban cities, buildings were built in the neighborhood, these buildings influence each other through structure-soilstructure interaction (SSSI) and seismic pounding due to limited separation distance in-between. Generally, the effects of the interaction between soil and structure are disregarded during seismic design and analysis of superstructure. However, the system of soil-base adversely changes structural behavior and response demands. Thus, the vibration characteristics plus the seismic response of a building are not able to be independent of those in adjacent buildings. The interaction between structure, soil, and structure investigates the action of the attendance of adjacent buildings to the others by the interaction effect of the sub-soil under dynamic disturbances. The main purpose of this research is to analyze the effects of SSSI and seismic pounding on the behavior of adjacent buildings. The response of a single structure or two adjacent structures with shallow raft base lying on soft soil are studied. Three dimensions finite element models are developed to investigate the effects of pounding; gap distance; conditions of soil; stories number; a mass of adjacent building and ground excitation frequency on the seismic responses and vibration characteristics of the structures. The variation in the story displacement, story shear, and story moment responses demands are studied to evaluate the presence effect of the adjacent buildings. Numerical results acquired using conditions of soil models are compared with the condition of fixed support and adjacent building models to a single building model. The peak responses of story displacement, story moment, and story shear are studied.

Seismic behavior of liquid storage tanks with 2D and 3D base isolation systems

  • Kilic, Samet;Akbas, Bulent;Shen, Jay;Paolacci, Fabrizio
    • Structural Engineering and Mechanics
    • /
    • 제83권5호
    • /
    • pp.627-644
    • /
    • 2022
  • In past major earthquakes (1994 Northridge, 1995 Kobe, Chi-Chi 1999, Kocaeli 1999), significant damages occurred in the liquid storage tanks. The basic failure patterns were observed to be the buckling of the tank wall and uplift of the anchorage system. The damages in the industrial facilities and nuclear power plants have caused the spread of toxic substances to the environment and significant fires. Seismic isolation can be used in liquid storage tanks to decouple the structure and decrease the structural demand in the superstructure in case of ground shaking. Previous studies on the use of seismic isolation systems on liquid storage tanks show that an isolation system reduces the impulsive response but might slightly increase the convective one. There is still a lack of understanding of the seismic response of seismically isolated liquid storage tanks considering the fluid-structure interaction. In this study, one broad tank, one medium tank, and one slender tank are selected and designed. Two- and three-dimensional elastomeric bearings are used as seismic isolation systems. The seismic performance of the tanks is then investigated through nonlinear dynamic time-history analyses. The effectiveness of each seismic isolation system on tanks' performance was investigated. Isolator tension forces, modal analysis results, hydrodynamic stresses, strains, sloshing heights and base shear forces of the tanks are compared. The results show that the total base shear is lower in 3D-isolators compared to 2D-isolators. Even though the tank wall stresses, and strains are slightly higher in 3D-isolators, they are more efficient to prevent the tension problem.

고온 고압 응력부식균열 개시 시험용 디스크 시편의 응력과 변형에 대한 유한요소 해석 (Finite Element Analysis of Stress and Strain Distribution on Thin Disk Specimen for SCC Initiation Test in High Temperature and Pressure Environment)

  • 김태영;김성우;김동진;김상태
    • Corrosion Science and Technology
    • /
    • 제22권1호
    • /
    • pp.44-54
    • /
    • 2023
  • The rupture disk corrosion test (RDCT) method was recently developed to evaluate stress corrosion cracking (SCC) and was found to have great potential for the real-time detection of SCC initiation in a high temperature and pressure environment, simulating the primary water coolant of pressurized water reactors. However, it is difficult to directly measure the stress applied to a disk specimen, which is an essential factor in SCC initiation. In this work, finite element analysis (FEA) was performed using ABAQUSTM to calculate the stress and deformation of a disk specimen. To determine the best mesh design for a thin disk specimen, hexahedron, hex-dominated, and tetrahedron models were used in FEA. All models revealed similar dome-shaped deformation behavior of the disk specimen. However, there was a considerable difference in stress distribution in the disk specimens. In the hex-dominated model, the applied stress was calculated to be the maximum at the dome center, whereas the stress was calculated to be the maximum at the dome edge in the hexahedron and tetrahedron models. From a comparison of the FEA results with deformation behavior and SCC location on the disk specimen after RDCT, the most proper FE model was found to be the tetrahedron model.

Buckling of 2D FG Porous unified shear plates resting on elastic foundation based on neutral axis

  • Rabab, Shanab;Salwa, Mohamed;Mohammed Y., Tharwan;Amr E., Assie;Mohamed A., Eltaher
    • Steel and Composite Structures
    • /
    • 제45권5호
    • /
    • pp.729-747
    • /
    • 2022
  • The critical buckling loads and buckling modes of bi-directional functionally graded porous unified higher order shear plate with elastic foundation are investigated. A mathematical model based on neutral axis rather than midplane is developed in comprehensive way for the first time in this article. The material constituents form ceramic and metal are graded through thickness and axial direction by the power function distribution. The voids and cavities inside the material are proposed by three different porosity models through the thickness of plate. The constitutive parameters and force resultants are evaluated relative to the neutral axis. Unified higher order shear plate theories are used to satisfy the zero-shear strain/stress at the top and bottom surfaces. The governing equilibrium equations of bi-directional functionally graded porous unified plate (BDFGPUP) are derived by Hamilton's principle. The equilibrium equations in the form of coupled variable coefficients partial differential equations is solved by using numerical differential integral quadrature method (DIQM). The validation of the present model is presented and compared with previous works for bucking. Deviation in buckling loads for both mid-plane and neutral plane are developed and discussed. The numerical results prove that the shear functions, distribution indices, boundary conditions, elastic foundation and porosity type have significant influence on buckling stability of BDFGPUP. The current mathematical model may be used in design and analysis of BDFGPU used in nuclear, mechanical, aerospace, and naval application.

Effects of inclined bedrock on dissimilar pile composite foundation under vertical loading

  • Kaiyu, Jiang;Weiming, Gong;Jiang, Xu;Guoliang, Dai;Xia, Guo
    • Geomechanics and Engineering
    • /
    • 제31권5호
    • /
    • pp.477-488
    • /
    • 2022
  • Pile composite foundation (PCF) has been commonly applied in practice. Existing research has focused primarily on semi-infinite media having equal pile lengths with little attention given to the effects of inclined bedrock and dissimilar pile lengths. This investigation considers the effects of inclined bedrock on vertical loaded PCF with dissimilar pile lengths. The pile-soil system is decomposed into fictitious piles and extended soil. The Fredholm integral equation about the axial force along fictitious piles is then established based on the compatibility of axial strain between fictitious piles and extended soil. Then, an iterative procedure is induced to calculate the PCF characteristics with a rigid cap. The results agree well with two field load tests of a single pile and numerical simulation case. The settlement and load transfer behaviors of dissimilar 3-pile PCFs and the effects of inclined bedrock are analyzed, which shows that the embedded depth of the inclined bedrock significantly affects the pile-soil load sharing ratios, non-dimensional vertical stiffness N0/wdEs, and differential settlement for different length-diameter ratios of the pile l/d and pile-soil stiffness ratio k conditions. The differential settlement and pile-soil load sharing ratios are also influenced by the inclined angle of the bedrock for different k and l/d. The developed model helps better understand the PCF characteristics over inclined bedrock under vertical loading.

고정된 사각형 수중 및 부유식 구조물에 의한 고립파의 처오름높이 저감 수치모의 (Numerical Simulation on Reduced Runup Height of Solitary Wave by Fixed Submerged and Floating Rectangular Obstacles)

  • 신충훈;김형석
    • 한국해안·해양공학회논문집
    • /
    • 제34권6호
    • /
    • pp.211-221
    • /
    • 2022
  • 파의 처오름높이는 제방, 호안 및 방파제와 같은 해안 구조물의 설계에 영향을 미치는 가장 중요한 매개변수 중 하나이다. 본 연구에서는 비정수압 수치모형인 SWASH(Zijlema et al., 2011)를 이용해 고정된 수중 및 부유식 사각형 구조물에 의한 고립파의 처오름높이 저감 효과를 분석하였다. SWASH 수치모형이 고립파의 전파, 쇄파 및 처오름현상을 매우 잘 재현하는 것을 확인하였다. 또한 수중 및 부유식 사각형 구조물에 의한 고립파의 파랑변형을 잘 재현하는 것을 확인하였다. 마지막으로 수중 및 부유식 사각형 구조물의 처오름높이 저감 효과를 검토하였다. 부유식 구조물의 에너지 감쇠효과는 수중 구조물보다 크고, 처오름높이 저감에 더 효과적인 것으로 나타났다.

부착식 텐던의 유효 긴장력 평가를 위한 최적의 매개변수 결정에 관한 연구 (A Study on the Determination of the Optimal Parameter for the Evaluation of the Effective Prestress Force on the Bonded Tendon)

  • 장정범;이홍표;황경민;송영철
    • 대한토목학회논문집
    • /
    • 제30권2A호
    • /
    • pp.161-168
    • /
    • 2010
  • 국내 가동 중 일부 원전의 원자로건물에 부착식 텐던이 설치되어 있고, 부착식 텐던에 대한 유효 긴장력 평가는 이들 원전의 계속운전을 위한 주요 현안으로 부각되고 있다. 따라서, 본 연구에서는 System Identification 기법을 이용한 부착식 텐던의 유효 긴장력 평가를 위하여, SI 기법에 유효한 주요 매개변수의 영향 평가를 수행하고 최적의 매개변수를 도출하였다. 본 연구를 위하여, 원자로건물 벽체의 1/5 축소모형 시험체를 제작하였고, 유효 긴장력과 고유진동수 및 변위와의 상관성을 분석하기 위하여 Impact test, SIMO sine sweep test 및 광섬유센서와 변위계에 의한 휨시험을 수행하였다. 시험결과, 고유진동수와 변위 모두 유효 긴장력과 좋은 상관성을 지니는 것으로 나타나, 이들 매개변수 모두 SI 기법의 입력자료로 활용되어 부착식 텐던의 유효 긴장력 예측이 가능한 것으로 분석되었다.

북한보험제도의 변화와 전망: 현지답사결과를 중심으로 (Recent Changes of Insurance Market in North Korea: Based on Field Study)

  • 최문;이재현;조승호;김범
    • 아태비즈니스연구
    • /
    • 제14권2호
    • /
    • pp.119-139
    • /
    • 2023
  • Purpose - This study is the first field study about the insurance market in North Korea. By analysing the information and the data collected from the visit to North Korea, we introduced the most recent change on the insurance market in North Korea and analyzed the impact of the change of economic policy on the insurance market. This study may enhance the understanding the current situation and provide expectations on the future of the insurance market in North Korea. Design/methodology/approach - This study is based on the field study doen in 2018 to Pyeong Yang, the capital of North Korea, The most information was collected from the legal documents, news papers and academic reports. Findings - During his regime from the year of 2012, Kim Jong Eun, the Supreme Leader of North Korea, initiated the drastic change in economic renovation policy in North Korea by shifting the economic system from the commodity economy to the market economy. Due to the policy, the insurance market in North Korea became marginally privatized and the market of life insurance contracts is expected to be increased if North Korea may resolve the political conflicts between North Korea and the United States and its allies in Asia mainly due to its nuclear testing. Research implications or Originality - Until now, very few studies have been done regarding the financial market in North Korea, especially about the insurance market. Our study provides unique information on the insurance market in North Korea because all the information and its implications are based on the field study in 2018.