• 제목/요약/키워드: Nozzle Efficiency

검색결과 420건 처리시간 0.029초

폴리우레탄 발포 노즐 형상이 혼합 성능에 미치는 영향 (Influences of Polyurethane Nozzle Shape on Mixing Efficiency)

  • 김도연;이태경;정해도;김형재
    • 한국정밀공학회지
    • /
    • 제33권1호
    • /
    • pp.31-35
    • /
    • 2016
  • For reaction injection molding (RIM) polyurethane was mixed in the mixing head by impingement mixing, injected into the mold, and cured quickly, as soon as the mold is filled. The shape of the nozzle in the mixing head is critical to improve the quality of polyurethane. To achieve homogeneous mixing, an intensive turbulence energy in the mixing nozzle is essential. In this study, a mixing nozzle for RIM was designed, and mixing efficiency was investigated based on experiment. Experiments were conducted with different combinations of nozzle tips and exit diameter to measure the mixing efficiency by measuring jet force and investigating mixing image with high speed camera. Jet force increased gradually and reaches steady state conditions. The jet force depended on shape of nozzle tip and outlet sizes. These results suggest that optimized nozzle configurations are necessary for high efficiency mixing with RIM.

증기 터빈 노즐 베인의 두께 변화와 유량별 등엔트로피 효율 변화에 관한 수치해석 (A Numerical Investigation on the Isentropic Efficiency of Steam Turbine Nozzle Stage with Different Nozzle Vane Thickness and Mass Flow Rate)

  • 이종현;박희성;정종윤;김준섭;정예림;박성원
    • 대한기계학회논문집B
    • /
    • 제41권10호
    • /
    • pp.685-691
    • /
    • 2017
  • 증기 질량 유량의 변화에 따른 증기 터빈 노즐 단의 등엔트로피 노즐 효율을 계산하였다. 증기상태에 관한 압축성 Navier-Stokes 방정식을 기반으로 삼차원 수치해석 모델이 개발되었다. 두 가지의 삼차원 노즐 형상으로 압력, 온도, 속도, 마하수, 그리고 Markov 에너지 손실 계수가 계산되었다. 노즐 블레이드의 두께가 15mm에서 45mm로 증가함에 따라 최대 효율의 질량 유량은 0.9kg/s에서 1.6kg/s로 증가하였으며 최대 등엔트로피 효율은 각각 96.66%, 97.32%로 계산되었다. 질량 유량에 따른 등엔트로피 노즐 효율과 Markov 에너지 손실 계수를 계산하여 Markov 에너지 손실 계수와 등엔트로피 노즐 효율이 선형적 반비례 관계가 있음을 규명하였다.

저온분사 코팅공정에서 초음속 슬릿노즐 사용시 유동장 해석 (A Numerical Analysis of Flow Field in the Silt Nozzle During Cold Spray Coating Process)

  • 박혜영;박종인;정훈제;장경수;백의현;한정환;김형준
    • 대한금속재료학회지
    • /
    • 제49권3호
    • /
    • pp.221-230
    • /
    • 2011
  • The cold spray process is an emerging technology that utilizes high velocity metallic particles for surface coating. Metallic powder particles are injected into a converging-diverging de Laval nozzle and accelerated to a high velocity by a supersonic gas flow. The cold spray process normally uses a circular nozzle that has a rather narrow spraying range. To overcome this fault, a slit nozzle was considered in this study. The slit nozzle is anticipated to reduce the coating process time because it has a wider coating width than the circular nozzle. However, the slit nozzle can reduce the coating efficiency because it does not allow as much gas and particle velocity as the circular nozzle. To improve the coating efficiency of a slit nozzle, the shape of the slit nozzle was modified. And the results of gas flow and particle behaviour according to the nozzlers shape were compared by the a numerical analysis. As a results, as Expansion Ratio(ER) of 7.5 was found to be the most optimal condition for enhancing the spraying efficiency when the ER was changed by the variation of nozzle neck and exit size.

횡류수차 노즐형상이 성능과 내부유동에 미치는 영향 (Effect of Nozzle Shape on the Performance and Internal Flow of a Cross-Flow Hydro Turbine)

  • 최영도;임재익;김유택;이영호
    • 한국유체기계학회 논문집
    • /
    • 제11권4호
    • /
    • pp.45-51
    • /
    • 2008
  • The purpose of this study is to examine the effect of nozzle shape on the performance and internal flow of a cross-flow hydro turbine. CFD analysis for three kinds of nozzle shape is conducted to simulate the effect of nozzle shape. The results reveal that relatively narrow nozzle width is effective to increase the turbine efficiency and output power. Almost output power is achieved at Stage 1. Therefore, optimum design of the nozzle shape is necessary to improve the turbine performance. Recirculation flow in the runner passage decreases the turbine efficiency and output power because the flow make hydraulic loss and collision loss in the region. Air should be put into the runner passage and the recirculating flow should be suppressed by the air layer in the runner.

광학식 입자 계수기 내 샘플 노즐 직경이 측정 효율 및 특성에 미치는 영향에 대한 실험적 연구 (Experimental analysis on effects of nozzle diameter on detection characteristics of an optical particle counter)

  • 송현우;김태욱;송순호
    • 한국입자에어로졸학회지
    • /
    • 제13권4호
    • /
    • pp.159-164
    • /
    • 2017
  • The detection efficiency and characteristics of an optical particle counter (OPC), with various sample nozzle outlet diameters, were experimentally investigated. The OPC system, which was built with original design, was made up of a diode laser, two photodetectors, and a variety of optics such as a beam splitter and a concave mirror. The cone-shaped sampling nozzle was designed to be changeable to alter the outlet diameter, within the range of 1 to 3 mm. For samples, sets of polystyrene latex (PSL) standard particle with various sizes of 1 to $3{\mu}m$, were used. As a result, detection efficiency of the OPC greatly decreased with larger nozzle outlet diameter. Moreover, increased nozzle outlet diameter means broader sample flow, thus caused light interference and multiple scattering which results in abnormal high peaks in scattered light signal. The ratio of abnormal peaks to regular signal of single particle increased with larger nozzle outlet diameter.

지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구 (Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations)

  • 안영철;이재근
    • 한국분무공학회지
    • /
    • 제9권3호
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF

집속효율 향상을 위한 외장유동노즐 가속 구간의 최적설계 연구 (Optimal Design of Sheath Flow Nozzle Acceleration Section for Improving the Focusing Efficiency)

  • 이진우;진정민;김윤제
    • 한국군사과학기술학회지
    • /
    • 제22권6호
    • /
    • pp.763-772
    • /
    • 2019
  • There is a need to use sheath flow nozzle to detect bioaerosol such as virus and bacteria due to their characteristics. In order to enhance the detection performance depending on nozzle parameters, numerical analysis was carried out using a commercial code, ANSYS CFX. Eulerian-lagrangian approach method is used in this simulation. Multiphase flow characteristics between primary fluid and solid were considered. The detection performance was evaluated based on the results of flow field in nozzle chamber such as focusing efficiency and swirl strength. In addition, Latin hypercube sampling(LHS) of design of experiment(DOE) was used for generating a near-random sampling. Then, the acceleration section is optimized using response surface method(RSM). Results show that the optimized model achieved a 6.13 % in a focusing efficiency and 11.47 % increase in swirl strength over the reference model.

분사펌프에 연결된 구동관로 위치변화에 따른 유동특성 (Flow Characteristics of Driven Nozzle Position Change in the Connected Injection Pump)

  • 손현철;박길문;고현선;이행남
    • 대한기계학회논문집B
    • /
    • 제33권4호
    • /
    • pp.215-224
    • /
    • 2009
  • Analysis for various driven nozzle position changes. The analysis was done for different Reynolds number in entrance region of jet-pump and for several diameter ratios of driven nozzle. (1) The largest absorption energy was found at the point s=1 in condition of diameter ratio 1:3.21 and point s=0.5 in condition of diameter ratio 1:2.25. (2) The absorption energy was not related to the change of entrance velocity and the driven nozzle position having the largest absorption energy was function for cross section ratio. (3) As the position of driven nozzle moves to the downstream, the absorption energy gets weaker. Because the energy from swirl was lost at the cross section gets smaller. (4) As the position of driven nozzle moves to the downstream, the injection energy leans to the upper direction wall and as the Reynolds number increase, the lean phenomenon is more distinct. (5) The flow quantity of driven nozzle, the diameter ratio 1:3.21, was 32% higher than that of 1 : 2.25 and as the inlet velocity gets faster the efficiency decreased. And as the cross section of the driven nozzle increases.

최적화기법을 이용한 초음속 충동형 터빈 노즐의 비대칭 설계 (Design of Supersonic Impulse Turbine Nozzle with Asymmetric Configuration using the Optimal Method)

  • 정수인;최병익;정은환;김귀순
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.61-65
    • /
    • 2011
  • 본 연구에서는 초음속 충동형 터빈의 노즐에서 나타나는 유동의 과소 과대팽창 문제를 최적화 기법을 이용하여 비대칭형상을 포함해 설계함으로써 개선시키고자 하였다. 노즐 형상 설계를 위해 8개의 설계변수를 설정하였으며 목적함수로는 후류 영역 출구까지의 정효율이 최대가 되도록 하였다. 최적화에는 iSIGHT-FD가 사용되었으며 근사최적화를 위한 방법으로는 Radial Basis Function을 이용하였다. 노즐유동의 계산에는 상용 코드인 FLUENT 6.3을 사용하였으며 개선된 노즐의 정효율은 기존 대비 1.35% 증가하였고 손실계수는 19.85% 감소하였다.

  • PDF

Effect of Guide Nozzle Shape on the Performance Improvement of a Very Low Head Cross Flow Turbine

  • Chen, Zhenmu;Singh, Patrick Mark;Choi, Young-Do
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.19-26
    • /
    • 2014
  • The cross flow turbine attracts more and more attention for its relatively wide operating range and simple structure. In this study, a novel type of micro cross flow turbine is developed for application to a step in an irrigational channel. The head of the turbine is only H=4.3m and the turbine inlet channel is open ducted type, which has barely been studied. The efficiency of the turbine with inlet open duct channel is relatively low. Therefore, a guide nozzle on the turbine inlet is attached to improve the performance of the turbine. The guide nozzle shapes are investigated to find the best shape for the turbine. The guide nozzle plays an important role on directing flow at the runner entry, and it also decreases the negative torque loss by reducing the pressure difference in Region 1. There is 12.5% of efficiency improvement by attaching a well shaped guide nozzle on the turbine inlet.