Clinical Analysis of Novalis Stereotactic Radiosurgery for Brain Metastases

  • Gu, Hae-Won;Sohn, Moon-Jun;Lee, Dong-Joon;Lee, Hye-Ran;Lee, Chae-Heuck;Whang, C.-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.245-251
    • /
    • 2009
  • Objective : The authors analyzed the effectiveness and therapeutic response of Novalis shaped beam radiosurgery for metastatic brain tumors, and the prognostic factors which influenced the outcome. Methods : We performed a retrospective analysis of 106 patients who underwent 159 treatments for 640 metastatic brain lesions between January 2000 and April 2008. The pathologies of the primary tumor were mainly lung (45.3%), breast (18.2%) and GI tract (13.2%). We classified the patients using Radiation Therapy Oncology Group Recursive Partitioning Analysis (RPA) and then analyzed the survival and prognostic factors according to the Kaplan Meier method and univariate analysis. Results : The overall median actuarial survival rate was 7.3 months from the time of first radiosurgery treatment while 1 and 2 year actuarial survival estimates were 31% and 14.4%, respectively. Median actuarial survival rates for RPA classes I, II, and III were 31.3 months, 7.5 months and 1.7 months, respectively. Patients' life spans, higher Karnofsky performance scores and age correlated closely with RPA classes. However, sex and the number of lesions were not found to be significantly associated with length of survival. Conclusion : This result suggests that Novalis radiosurgery can be a good treatment option for treatment of the patients with brain metastases.

Novalis Stereotactic Radiosurgery for Spinal Dural Arteriovenous Fistula

  • Sung, Kyoung-Su;Song, Young-Jin;Kim, Ki-Uk
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.420-424
    • /
    • 2016
  • The spinal dural arteriovenous fistula (SDAVF) is rare, presenting with progressive, insidious symptoms, and inducing spinal cord ischemia and myelopathy, resulting in severe neurological deficits. If physicians have accurate and enough information about vascular anatomy and hemodynamics, they achieve the good results though the surgery or endovascular embolization. However, when selective spinal angiography is unsuccessful due to neurological deficits, surgery and endovascular embolization might be failed because of inadequate information. We describe a patient with a history of vasospasm during spinal angiography, who was successfully treated by spinal stereotactic radiosurgery using Novalis system.

Novalis Radiosurgery of Primary Central Nervous System Lymphoma in Elderly Patients : Preliminary Results

  • Han, Seong-Rok;Yee, Gi-Taek;Choi, Chan-Young;Sohn, Moon-Jun;Lee, Dong-Joon;Whang, Choong-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.6
    • /
    • pp.409-412
    • /
    • 2006
  • Objective : Primary central nervous system lymphoma[PCNSL] is a non-Hodgkin's lymphoma arising in the central nervous system. Combined chemotherapy and radiation therapy is the standard treatment for PCNSL. However, treatment induced neurotoxicity is a major problem especially in elderly patients. Methods : From May 2001 to April 2004, elderly five patients with PCNSL confirmed via pathological examination were underwent Novalis radiosurgery in authors' institution, who were investigated retrospectively. Of these patients, 2 were male and 3 were female, with a mean age 68 years old [range $65{\sim}73$]. The number of lesions was 1 in 2 patients, 2 in 2, and 3 in 1. The mean follow up period was 12.6 months [range $8{\sim}16$]. Results : Clinical symptoms and signs in all patients markedly improved within 1 weeks after Novalis radiosurgery. The Karnofsky performance status score was also improved from a pre-radiosurgery average of 68 to a post-radiosurgery one of 82. All of treated lesions showed a partial or complete regression of the original mass. There have been no complication following Novalis radiosurgery. Conclusion : The preliminary results of our experience indicate that radiosurgery with Novalis provides a safe and effective therapeutic alternative treatment of PCNSL in elderly patients.

Development of Novalis Quality Assurance Protocol for Radiosurgery (방사선수술을 위한 노발리스 품질관리 프로토콜 개발)

  • Lee, Dong-Joon;Lee, Kyung-Nam;Lee, Suk;Lee, Sang-Hoon;Kim, Dae-Hong
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.99-112
    • /
    • 2010
  • In Republic of Korea, there are many Quality Assurance protocol for general radiation treatment machine such as linac. However, Quality Assurance protocol for radiosurgery treatment system is not ready perfectly. One of the radiation treatment machine for radiosurgery, novalis system needs to suitable Quality Assurance protocol for using it right way during radiation treatment and maintaining suitable accuracy for daily, weekly, monthly and annually periods. Therefore, in this article, we develop Quality Assurance protocol for novalis system. We collected and analysed domestic and foreign novalis Quality Assurance protocol. After that, we selected essential QA items and each tolerance range for developing proper QA protocol, and we made anatomical phantom for execution of selected QA items and evaluation of overall state of QA, and then, we use this measured value as a reference. Quality Assurance items are consisted of Mechanical accuracy QA part and Radiation delivery QA part. Mechanical accuracy QA part is comprised of radiation generation machine part, assistive devices part and multi-leaf collimator part. Radiation delivery QA part is divided into radiation isocenter accuracy and dosimetric evaluation. After that, developed novalis QA tables are made by using these QA items. These novalis QA tables would be used to good standard in order to maintain apt accuracy for radiosurgery in daily, weekly, monthly and annually periods.

Fractionated Stereotactic Radiosurgery for Brain Metastases Using the Novalis Tx® System

  • Lim, Tae Kyoo;Kim, Woo Kyung;Yoo, Chan Jong;Kim, Eun Young;Kim, Myeong Jin;Yee, Gi Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.525-529
    • /
    • 2018
  • Objective : To evaluate the efficacy of fractionated stereotactic radiosurgery (FSRS) performed using the Novalis $Tx^{(R)}$ system (BrainLAB AG, Feldkirchen, Germany; Varian Medical Systems, Palo Alto, CA, USA) for brain metastases. Methods : Between March 2013 and July 2016, 23 brain metastases patients were admitted at a single institute. Twenty-nine lesions too large for single session stereotactic radiosurgery or located in the vicinity of eloquent structures were treated by FSRS. Based on the results obtained, we reviewed the efficacy and toxicity of FSRS for the treatment of brain metastases. Results : The most common lesion origin was lung (55%) followed by breast (21%). Median overall survival was 10.0 months (95% confidence interval [CI], 4.9-15.0), and median progression-free survival was 10.0 months (95% CI, 2.1-13.9). Overall survival rates at 1 and 2 years were 58.6% and 36.0%, respectively. Local recurrence and neurological complications affecting morbidity each occurred in two cases. Conclusion : FSRS using the $Novalis-Tx^{(R)}$ system would appear to be an effective, safe noninvasive treatment modality for large and eloquently situated brain metastases. Further investigation is required on a larger number of patients.

Novalis Shaped Beam Radiation Treatment for Craniopharyngiomas

  • Yee, Gi-Taek;Han, Seong-Rok;Yoon, Sang-Won;Choi, Chan-Young;Lee, Dong-Joon;Whang, Choong-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.4
    • /
    • pp.245-248
    • /
    • 2006
  • Objective : To evaluate the effectiveness of Novalis shaped beam radiation treatment as an adjuvant treatment in patients with craniopharyngiomas. Methods : We reviewed 8 patients with craniopharyngiomas who had recurring tumors during follow-up or had residual lesions after primary surgery. Three of 8 patients were found to have recurrence after gross total excision of the tumor and 5 patents had residual lesions after subtotal resection. All patients were treated with fractionated stereotactic radiation treatment[FSRT] using Novalis system. The mean age of patients was 28 years [range $16{\sim}52$]. The median irradiation dose per fraction was 17Gy [range $1.7{\sim}2.0$]. The median fraction number was 23 [range $15{\sim}25$], and the median total dose was 39.1 Gy [range $25.5{\sim}42.5$]. Follow-up included MR imaging, and ophthalmologic and endocrine examinations. Results : The median follow-up period was 23 months [range $12{\sim}43$]. The local tumor control rate was 87.5%. One patient had a recurring tumor, in which cystic change developed 2 months after FSRT. Four patients showed a decrease in size of their tumor, while 3 patients remained stable. Seven out of 8 patients had hormonal dysfunction that remained unchanged after initial surgery. No further progression of visual impairment was observed. Conclusion : FSRT using Novais system is effective and safe for the treatment of recurring or residual craniopharyngiomas without toxicity like optic neuropathy.

Application of the ExacTrac System in Respiratory Gated Radiotherapy for Lung Cancer Patients (폐암 환자의 호흡연동방사선치료를 위한 ExacTrac 시스템 적용)

  • Ko, Seung Young;Lee, Jung Il
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.325-332
    • /
    • 2019
  • This study analyzed the movement of tumors using 4DCT. Appropriate uniform IM were identified using TC, II and CI depending on ITV margins. DVH and NTCP were also compared in each case. Dose analysis on tumors with uniform IM showed that the optimal treatment plan for satisfying all TC, CI, II was evaluated as 2 mm in phase 20 and 3 mm in 40%. That was compared to the dose from the normal tissues of $PTV_{20}$, $PTV_{40}$. In the 20% radiation field, V5, V10, and V20 for the lungs increased 1.49, 1.26, and 0.65%, while 40% increased by 1.9, 2.41 and 1.23%. NTCP had a dose increase of 0.57 to 0.029% from 20% and 40%. There was a dose increase in the spinal cord and heart at uniform IM, but there was no significant difference. These data suggest that the ITV setting of 20%, phase for Respiratory Gated Radiotherapy using Novalis ExacTrac system can be applied with a uniform IM 2 mm and 40% with 3 mm for optimal treatment plan.

Assessment of the Optic-guided Patient Positioning for Spinal Stereotactic Radiosurgery Using Novalis ExacTrac System (노발리스 ExacTrac system을 이용한 척추 정위 방사선수술 방법 평가)

  • 이동준;손문준;최광영;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.218-223
    • /
    • 2002
  • Stereotactic radiosurgery for intracranial lesion is well established since the Lars Leksell first introduced radiosurgery concept in 1951 Its use in the treatment of spinal lesion has been limited by the availability of effective immobilization devices. The first clinical experience of the spinal stereotactic radiosurgery technique was reported by Hamilton AJ. in 1995. Recently, Optic-guided patient positioning technique for extracranial stereotactic radiosurgery was developed and reported. This study is for assess the target positioning accuracy of the optic guided patient positioning system Exactrac (BrainLab., Inc, Germany). We have designed phantom for assess the accuracy of spinal stereotactic radiosurgery The infrared reflective body markers attached to the relatively immobile part of the body and a series of 2 mm CT images was taken. The image sets were transferred to the planning computer. During the radiosurgery treatment, we measure the real-time display showing the positioning values from Exactrac computer. And we compare the isocenter deviation from irradiated center point of the film which was mounted on the lesion site of the phantom and pin hole site of that film. The accuracy of the ExacTrac system in positioning a target point shows enough for the clinical applications.

  • PDF

Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy : a retrospective study

  • Oh, Se An;Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.2
    • /
    • pp.108-115
    • /
    • 2022
  • Background: This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device. Portal dosimetry is extensively used for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Methods: The study includes 29 patients who underwent IMRT on a Novalis-Tx linear accelerator (Varian Medical System and Brain-LAB) between June 2019 and March 2021. We analyzed the multileaf collimator DynaLog files generated after portal dosimetry to evaluate the same condition using FractionLab. The results of the recently launched FractionLab at various gamma indices (0.1%/0.1 mm-1%/1 mm) are analyzed and compared with those of portal dosimetry (3%/3 mm). Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and FractionLab are 98.1% (95.5%-100%) and 97.5% (92.3%-99.7%) at 0.6%/0.6 mm, respectively. The results of portal dosimetry (3%/3 mm) are statistically comparable with the QA results of FractionLab (0.6%/0.6 mm-0.9%/0.9 mm). Conclusion: This paper presents the clinical performance of FractionLab by the comparison of the QA results of FractionLab using portal dosimetry with various gamma indexes when performing patient-specific QA in IMRT treatment. Further, the appropriate gamma index when performing patient-specific QA with FractionLab is provided.

Respiratory signal analysis of liver cancer patients with respiratory-gated radiation therapy (간암 호흡동조 방사선치료 환자의 호흡신호분석)

  • Kang, dong im;Jung, sang hoon;Kim, chul jong;Park, hee chul;Choi, byung ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Purpose : External markers respiratory movement measuring device (RPM; Real-time Position Management, Varian Medical System, USA) Liver Cancer Radiation Therapy Respiratory gated with respiratory signal with irradiation time and the actual research by analyzing the respiratory phase with the breathing motion measurement device respiratory tuning evaluate the accuracy of radiation therapy Materials and Methods : May-September 2014 Novalis Tx. (Varian Medical System, USA) and liver cancer radiotherapy using respiratory gated RPM (Duty Cycle 20%, Gating window 40% ~ 60%) of 16 patients who underwent total when recording the analyzed respiratory movement. After the breathing motion of the external markers recorded on the RPM was reconstructed by breathing through the acts phase analysis, for Beam-on Time and Duty Cycle recorded by using the reconstructed phase breathing breathing with RPM gated the prediction accuracy of the radiation treatment analysis and analyzed the correlation between prediction accuracy and Duty Cycle in accordance with the reproducibility of the respiratory movement. Results : Treatment of 16 patients with respiratory cycle during the actual treatment plan was analyzed with an average difference -0.03 seconds (range -0.50 seconds to 0.09 seconds) could not be confirmed statistically significant difference between the two breathing (p = 0.472). The average respiratory period when treatment is 4.02 sec (${\pm}0.71sec$), the average value of the respiratory cycle of the treatment was characterized by a standard deviation 7.43% (range 2.57 to 19.20%). Duty Cycle is that the actual average 16.05% (range 13.78 to 17.41%), average 56.05 got through the acts of the show and then analyzed% (range 39.23 to 75.10%) is planned in respiratory research phase (40% to 60%) in was confirmed. The investigation on the correlation between the ratio Duty Cycle and planned respiratory phase and the standard deviation of the respiratory cycle was analyzed in each -0.156 (p = 0.282) and -0.385 (p = 0.070). Conclusion : This study is to analyze the acts after the breathing motion of the external markers recorded during the actual treatment was confirmed in a reproducible ratios of actual treatment of breathing motion during treatment, and Duty Cycle, planned respiratory gated window. Minimizing an error of the treatment plan using 4DCT and enhance the respiratory training and respiratory signal monitoring for effective treatment it is determined to be necessary.

  • PDF