• 제목/요약/키워드: Nose Detection

검색결과 74건 처리시간 0.03초

개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발 (A portable electronic nose (E-Nose) system using PDA device)

  • 양윤석;김용신;하승철;김용준;조성목;표현봉;최창억
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.

전자코를 이용한 살모넬라 식중독균 판정 (Identification of Salmonella Pathogen Using Electronic Nose)

  • 김기영;이민욱;이강진;최규홍;노광모;강석원;장영창
    • Journal of Biosystems Engineering
    • /
    • 제30권2호
    • /
    • pp.121-126
    • /
    • 2005
  • In this study, a commercial electronic nose system was used to detect contamination of Salmonella bacteria. Odors from growth media contaminated with Salmonella typhimurium, Salmonella enteritidis, or Escherichia coli were collected and analyzed to evaluate a possibility of rapid detection of pathogen. Odor chromatograph showed that S. typhimurium, S. enteritidis, and E. coli had 7,6, and 9 main peaks, respectively. Retention time and intensity of the peaks were distinct for different bacteria species. Principal component analysis (PCA) were also performed to clarify odor differences. Analysis results showed that the odors for uncontaminated growth medium were differently grouped from the odors of contaminated one. The odor from the bacteria growth identified with two principal components, PC 1 and PC2. In PCA figures, odor groups were moved from left to right of PC 1 with elapse of the bacteria growth time. The electronic nose system could detect odors of S. typhimurium, S. enteritidis, E. coli when their concentration were $1.85\times10^6\;cfu/g,\;2.25\times10^6\;cfu/g,\;and\;1.8\times10^5 cfu/g$, respectively.

An Array-Based Sensor for Seafood Freshness Assessment

  • Gonzalez-Martin, Anuncia;Lewis, Brian;Raducanu, Marius;Kim, Jin-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권11호
    • /
    • pp.3084-3092
    • /
    • 2010
  • This paper describes the development of an automated, hand-held sensor for the fast assessment of seafood freshness. The sensor developed here combined: an array-based chemical sensor, composed of incrementally different conducting polymer elements deposited on a small chip; a highly sensitive, custom-made electronics for the detection of very small signal changes; precise temperature control of the sensor chamber; and an on-board microcontroller for data collection, storage, automation, and analysis. The instrument was used to successfully test seafood samples with different degree of freshness and spoilage. A linear relationship between microbiological count and e-Nose signal for three different fish fillet was developed. Once the linear relationship is included into the hand-held unit software, the e-Nose signal can be used for assessment of seafood freshness without performing the microbiological count technique.

목 부분의 제거를 통한 얼굴 검출 향상 기법 (Improvement of Face Components Detection using Neck Removal)

  • 윤가림;윤요섭;김영봉
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2004년도 추계 종합학술대회 논문집
    • /
    • pp.321-326
    • /
    • 2004
  • 보통 사람의 정면과 측면 사진 등을 이용하여 3차원 얼굴 모델에 텍스처를 입히는 많은 연구들이 수행되어 오고 있다. 많은 좋은 결과들이 나타나고 있다. 정면 사진이나, 측면 사진에서 사람의 눈, 코 입 등의 위치를 정확히 추출하는 일은 이 작업에서 가장 중요한 요소라 할 것이다. 기존의 연구들은 눈의 위치 혹은 입이나 코의 위치를 대충 찾은 다음에 그 상관관계에 따라 얼굴의 각 요소를 추출해 내는 방법을 많이 쓰고 있다. 이 때 가장 문제가 되는 부분이 목 부분이 제대로 인식되어 얼굴 부분에서만 얼굴 요소를 찾으면 정확한 결과를 보이는데, 목 과 턱선의 구분의 불명확으로 나타난 경우에는 잘못된 결과를 보이고 있다. 따라서 본 연구에서는 전체의 얼굴 영상에서 턱 아래 부분을 제거함으로써 얼굴 요소의 검출이 향상되도록 하는 알고리즘을 제시할 것이다. 턱 아래 부분의 완전한 제거를 위해 본 연구에서는 RGB값과 그 기울기를 이용하여 목 부분을 효율적으로 제거하는 방법을 제시할 것이다.

  • PDF

Hyaluronic Acid Filler Injection Guided by Doppler Ultrasound

  • Won Lee
    • Archives of Plastic Surgery
    • /
    • 제50권4호
    • /
    • pp.348-353
    • /
    • 2023
  • Doppler ultrasound can be used to detect almost all arteries of the face before injecting the hyaluronic acid (HA) filler. The relatively more dangerous sites of filler injection are the glabellar wrinkle, forehead, temple, nose, and nasolabial fold area, and it is recommended to map the vasculature of these areas by Doppler ultrasound before performing filler injection. The Doppler ultrasound detection method is included as a video. Internal carotid arterial branches, the supratrochlear, supraorbital, and dorsal nasal arteries, and external carotid arterial branches, the superficial temporal and facial arteries, are very important arteries when injecting HA filler; thus, Doppler ultrasound detection is recommended.

Adaptive Background Modeling Considering Stationary Object and Object Detection Technique based on Multiple Gaussian Distribution

  • Jeong, Jongmyeon;Choi, Jiyun
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권11호
    • /
    • pp.51-57
    • /
    • 2018
  • In this paper, we studied about the extraction of the parameter and implementation of speechreading system to recognize the Korean 8 vowel. Face features are detected by amplifying, reducing the image value and making a comparison between the image value which is represented for various value in various color space. The eyes position, the nose position, the inner boundary of lip, the outer boundary of upper lip and the outer line of the tooth is found to the feature and using the analysis the area of inner lip, the hight and width of inner lip, the outer line length of the tooth rate about a inner mouth area and the distance between the nose and outer boundary of upper lip are used for the parameter. 2400 data are gathered and analyzed. Based on this analysis, the neural net is constructed and the recognition experiments are performed. In the experiment, 5 normal persons were sampled. The observational error between samples was corrected using normalization method. The experiment show very encouraging result about the usefulness of the parameter.

Drowsiness Detection Method during Driving by using Infrared and Depth Pictures

  • You, Gang-chon;Park, Do-hyun;Kwon, Soon-kak
    • Journal of Multimedia Information System
    • /
    • 제5권3호
    • /
    • pp.189-194
    • /
    • 2018
  • In this paper, we propose the drowsiness detection method for car driver. This paper determines whether or not the driver's eyes are closed using the depth and infrared videos. The proposed method has the advantage to detect drowsiness without being affected by illumination. The proposed method detects a face in the depth picture by using the fact that the nose is closest to the camera. The driver's eyes are detected by using the extraction of harr-like feature within the detected face region. This method considers to be drowsiness if eyes are closed for a certain period of time. Simulation results show the drowsiness detection performance for the proposed method.

Rapid Detection of Bacteria from Blood Culture by an Electronic Nose

  • Lykos, Peter;Patel, Pravin H.;Morong, Christopher;Joseph, Asha
    • Journal of Microbiology
    • /
    • 제39권3호
    • /
    • pp.213-218
    • /
    • 2001
  • The treatment of Patients with bacteraemia and septicemia requires accurate and rapid identification of the pathogen so that the physician can be guided regarding the selection of the proper antimicrobial therapy. The usual procedure is to withdraw an aliquot of the positive blood culture sample for gram staining and subculturing on the media for the growth and subsequent identification, and susceptibility determinations. It was noticed that during the process some microbiologists would sniff the effluent gases that are products of metabolism and in some cases guess the identity of the bacterium. That Prompted us to engage in systematic investigation of two gram positive and two gram negative bacteria using an electronic nose that had been proven successful in distinguishing the aroma of coffee beans from different sources. The investigation was successful in illustrating the efficacy of such a device in this clinical setting to distinguish Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Enterococcus faecalis. A representative set of patterns obtained with this apparatus is displayed as well. A representative set of patterns obtained with this apparatus is displayed as well. No effort was made to determine an optimal set of sensors for some specific set of bacterial metabolism gaseous products.

  • PDF

Wound-State Monitoring for Burn Patients Using E-Nose/SPME System

  • Byun, Hyung-Gi;Persaud, Krishna C.;Pisanelli, Anna Maria
    • ETRI Journal
    • /
    • 제32권3호
    • /
    • pp.440-446
    • /
    • 2010
  • Array-based gas sensors now offer the potential of a robust analytical approach to odor measurement for medical use. We are developing a fast reliable method for detection of microbial infection by monitoring the headspace from the infected wound. In this paper, we present initial results obtained from wound-state monitoring for burn patients using an electronic nose incorporating an automated solid-phase microextraction (SPME) desorption system to enable the system to be used for clinical validation. SPME preconcentration is used for sampling of the headspace air and the response of the sensor module to variable concentrations of volatiles emitted from SPME fiber is evaluated. Gas chromatography-mass spectrometry studies prove that living bacteria, the typical infectious agents in clinical practice, can be distinguished from each other by means of a limited set of key volatile products. Principal component analysis results give the first indication that infected patients may be distinguished from uninfected patients. Microbial laboratory analysis using clinical samples verifies the performance of the system.

Skin-tone과 특징형태를 적용한 효율적인 얼굴영역 자동검출 기법의 구현 (Efficient and Automatic Face Detection Using Skin-tone and Shape)

  • 김광희;김성환;최옥매;이배호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.575-578
    • /
    • 1999
  • The principal features of a face are as follows : skin-tone, symmetry, and requisites such as shape of ellipse, eyes, nose, mouth. Also, faces have different size, various shape and position. In case of application of face recognition and detection without preprocessing, efficiency of the performance is decreased. In addition, face itself, complex background, image quality, etc. are included. Therefore, previous face recognition methods are implemented on the base of specific constraints of the face image. In this paper, we propose the efficient and automatic face detection algorithm for minimizing influence such as complex background, image quality, etc. This face detection technique consists of skin-tone, candidate face region and face region extractions.

  • PDF