• Title/Summary/Keyword: Normally-off

Search Result 93, Processing Time 0.024 seconds

A Study on Security Architecture for Digital Content Dissemination (디지탈 컨텐츠 배포를 위한 보안 체계에 관한 연구)

  • 김대엽;주학수
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.13 no.1
    • /
    • pp.147-155
    • /
    • 2003
  • The diffusion of internet infrastructure and a fast increase of Population to use it is becoming a base of the service that can use various information, data and digital contents which were provided through off-line physically and used. Recently, the. techniques for copy deterrence and copyright protection have been important in e-commerce because various contents in digital form can be duplicated easily. The Access Control(AC) technique that only a user having the qualifications can access and use contents normally has been studied. The Conditional Access System(CAS) used in a satellite broadcasting md Digital Right Management System(DRMS) used for contents service are representative models of current commercialized access control. The CAS and DRM can be considered as an access control technique based on the payment based type(PBT). This paper describe the access control method of payment free type(PFT) suggested in [5] which are independent on the payment structure. And then we suggest a new access control method of payment free type which is more efficient than the previous one.

Theoretical Consideration of Nondestructive Testing by use of Vertical Magnetization and Magneto-Optical Sensor

  • Lee, Jinyi;Tetsuo Shoji;Dowon Seo
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.640-648
    • /
    • 2004
  • This paper describes a new magnetization method for non-destructive testing with magneto-optical sensor (denoted as MO sensor) which have the following characteristic : high observation sensitivity, independence of the crack orientation, and precise imaging of a complex crack geometry such as multiple cracks. When a magnetic field is applied normally to the surface of a specimen which is significantly larger than its defects, approximately the same magnetic charge per unit area occurs on the surface of the specimen. If there is a crack in the specimen, magnetic charge per unit area has the same value at the bottom of the crack. The distribution of the vertical component of the magnetic flux density, B$\_$Z/, is almost uniform over the no-crack area (denoted as B$\_$Z,BASE/), while the magnetic flux density is smaller in the surroundings of the crack(denoted as B$\_$Z,CRACK/) If B$\_$Z, BASE/ is a bit larger than the saturated magnetic flux density of the MO sensor (B$\_$s/) , then small magnetic domains occur over the crack area and a large domain over the non-crack area because B$\_$Z,CRACK/ is smaller than B$\_$s/.

Simulations of Effects of Variable Conductance Throttle Valve on the Characteristics of High Vacuum System

  • Kim, Hyung-Taek;Cho, Han-Ho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.28-35
    • /
    • 2015
  • Thin film electronic devices which brought the current mobile environment could be fabricated only under the high quality vacuum conditions provided by high vacuum systems. Especially for the development of advanced thin film devices, constant high quality vacuum as the deposition pressure is definitely needed. For this purpose, the variable conductance throttle valves were employed to the high vacuum system. In this study, the effects of throttle valve applications on vacuum characteristics were simulated to obtain the optimum design modelling of variable conductance of high vacuum system. Commercial simulator of vacuum system, $VacSim^{(multi)}$, was used on this investigation. Reliability of employed simulator was verified by the simulation of the commercially available models of high vacuum system. Simulated vacuum characteristics of the proposed modelling were agreed with the observed experimental behaviour of real systems. Pressure limit valve and normally on-off control valve were schematized as the modelling of throttle valve for the constant process-pressure of below $10^{-3}torr$. Simulation results were plotted as pump down curve of chamber, variable valve conductance and conductance logic of throttle valve. Simulated behaviors showed the applications of throttle valve sustained the process-pressure constantly, stably, and reliably.

Variable speed control of low power motor by using the astable multivibrator (비안정 멀티바이브레이터를 이용한 가변속도 가능한 저전력 모터)

  • Lee, Yong-IL
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.1
    • /
    • pp.167-171
    • /
    • 2018
  • We have developed ideal products that need low power by utilizing astable multivibraters since we are in need of technology that can be adaptable to any environments anytime because tons of thousands of electric products and IT products need to be operated by low power DC motors. Since motors generally use much electricity in an initial stage of operation, we have testified and proved the technology that can be furnished with any kinds of motors including those of AC and DC by loading them with on-off systems with electric pulse with operating methodology that has realized low-electrical operation when normally operated.

4H-SiC High Power VJFET with modulation of n-epi layer and channel dimension (N-epi 영역과 Channel 폭에 따른 4H-SiC 고전력 VJFET 설계)

  • Ahn, Jung-Joon;Bahng, Wook;Kim, Sang-Cheol;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.350-350
    • /
    • 2010
  • Silicon carbide (SiC), one of the well known wide band gap semiconductors, shows high thermal conductivities, chemical inertness and breakdown energies. The design of normally-off 4H-SiC VJFETs [1] has been reported and 4H-SiC VJFETs with different lateral JFET channel opening dimensions have been studied [2]. In this work, 4H-SiC based VJFETs has been designed using the device simulator (ATLAS, Silvaco Data System, Inc). We varied the n-epi layer thickness (from $6\;{\mu}m$ to $10\;{\mu}m$) and the channel width (from $0.9\;{\mu}m$ to $1.2\;{\mu}m$), and investigated the static characteristics as blocking voltages, threshold voltages, on-resistances. We have shown that silicon carbide JFET structures of highly intensified blocking voltages with optimized figures of merit can thus be achieved by adjusting the epi layer thickness and channel width.

  • PDF

A Study on Monitoring Means of Insulation deterioration of Electric Power Cable (전력케이블 열화 감시방안에 관한 연구)

  • Han, Hag-Su;Min, Kyung-Yun;Ryu, Ki-Son
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1522-1528
    • /
    • 2007
  • Electric Power cable is the apparatus that receives electric power from the Korea Electric Power Corporation and supplies electric power to electric train and annex facilities of each railway station. With substantial ripple effect during power blackout accidents, such power blackout accidents must be coped with by discriminating the status of insulation deterioration of electric power cable in advance. Discrimination of insulation deterioration of the electric power cable is normally executed while the power is disconnected and it is very difficult to discover, at early stage, the insulation deterioration of the power cable in operational state since the duration of inspection is limited. This research aims to consider method of diagnosing the insulation deterioration of electric power cable in On-Line state rather than diagnosis in Off-Line state in order to secure reliability of power supply by reducing duration of power blackout (accidental blackout and blackout during works) and by seeking reduction in equipment and manpower used in diagnosis of deterioration through prevention of the accident itself prior to occurrence through early restoration of accident due to insulation deterioration of the electric power cable and assessment of performance of the cable under operation.

  • PDF

Development of the Auto-Aging Test Controller for a Hydraulic Motor (유압모터 길들이기 자동시험 제어기 개발)

  • Jung, Gyu Hong;Shin, Dae Young;Seo, Dong Jin
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.28-34
    • /
    • 2015
  • Because heavy-duty construction vehicles such as excavators are required for good engine-room cooling capacity, a hydraulic gear motor is adopted in the cooling fan drive mechanism to actively control the output speed, instead of adopting the conventional ON/OFF type belt drive. While gear motors are normally limited to 140bars of operating pressure, those for the cooling fan are capable of operating at continuous pressures of up to 220bars. After assembly, all gear motors for high pressure must pass an aging test which is a kind of the wearing process between the gear teeth and motor housing. During the aging process with gradual pressure increments, gear sticking sometimes occurs due to abnormal wear, resulting in defects. This paper focuses on a gear-sticking free aging test controller that is designed together with the knowledge of an experienced operator and the analysis results of experimental data of the gear jamming phenomenon. From the aging experiment, it is demonstrated that the developed controller that can alter the setting pressure of the load pump is effective for stabilizing the abrupt increase in the motor input pressure, thus preventing the hydraulic motor from stopping. This is expected to be helpful for the reduction of defects and increase in productivity.

A Study on the Explosive Plugging of A Repair for Defective Tube/Tubeplate on the Nuclear Steam Generator (원자력 증기발생기 결함 세관 보수용 폭발 Plugging에 관한 연구)

  • 이병일;심상한;강정윤;이상래
    • Explosives and Blasting
    • /
    • v.17 no.4
    • /
    • pp.18-31
    • /
    • 1999
  • The explosive forming has been used for many year to expand tubes into tubesheets. this process has demonstrated ability to direct carefully the energy of an explosive to expand tubes into tubesheet holes without damaging the tubesheet and without causing the excessive cold work at the tube I.D. that is normally associated with mechanical expansion. The success of explosive tube expansion provided the background for the development of the explosive tube plug. The main results are as follows : (1) The optimum explosives and explosive qualities are PETN, RDX, HMS and about 18~31gr/ft of explosive plugging in nuclear steam generator. (2) Explosive plugging's thickness is 0.9~1.8mm. If groove of 0.4 mm formed in plug outside, For the hydraulic leakage is go up, explosive plugging of formed groove are applicate tube and tubrplate. (3) Sheath is designed on the polyethylene of low density, In thermal impact test of the $430^\circ{C}$, hydraulic leakage is $300kg/cm^2$. (4) About 10~60mm oxide inclusions are existed on the space of explosive plug and tube protect to the leakage.

  • PDF

A Study on the Modified Safety Valve for Vessels of Liquefied Petroleum Gas (LP가스 용기용 안전 밸브 개발에 관한 연구)

  • Rhim Jong-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.2 s.27
    • /
    • pp.38-42
    • /
    • 2005
  • This study introduced concept of safety valve about development of valve for LP gas cylinders. LP gas cylinders are used more because of convenience of use, but a lot of accidents are occurred. Specially, it is used by purpose to injure glossary or others and is sometimes used to a demonstration tool. Korean government was making mandatory to use overuse cutoff valve to reduce accident, but it is real condition that product development is not following. In this study, introduce concept of safety valve that introduce more original safety concept than overuse cutoff valve. This was developed by method that insert module to present use valve and flowing of gas is controlled in state that hose or regulator un-connects to valve. Also, flowing of gas cut-off immediately if hose is cut or occurrence of overuse is produced even if is using normally.

  • PDF

A Modularized Charge Equalizer Using the Magnetizing Energy of the Multi-Winding Transformer (다권선 변압기의 자화 에너지를 이용한 모듈화 전하 균일 장치)

  • Lim, Chang-Soon;Hyun, Dong-Seok;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.393-400
    • /
    • 2012
  • The modularized equalizers normally use additional components among the modules in the long series-connected lithium-ion battery string. In these approaches, the overall systems are heavy, bulky, and high-priced. Furthermore, the losses related to additional components decrease the system efficiency. To avoid these problems, a modularized equalizer, which has no additional components among the modules, is required. This paper proposes a novel control scheme using the magnetizing energy of the multi-winding transformer for the module equalization. In this scheme, the high duty cycle is applied to the module where the voltage is higher than the reference voltage and the low duty cycle is applied to the module where the voltage is lower than the reference voltage. Due to the different duty cycle, more electric charges are transferred from high voltage module to the low voltage module during the turn-off switching interval. Using the proposed control scheme, the equalizer system does not suffer from the size, cost, and loss related to the modularization. The experimental results are provided to verify the effectiveness of the proposed modularized equalizer.