• Title/Summary/Keyword: Normalized parameters

Search Result 459, Processing Time 0.029 seconds

Power Estimation and Optimum Design of a Buoy for the Resonant Type Wave Energy Converter Using Approximation Scheme (근사기법을 활용한 공진형 파력발전 부이의 발전량 추정 및 최적설계)

  • Koh, Hyeok-Jun;Ruy, Won-Sun;Cho, Il-Hyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.85-92
    • /
    • 2013
  • This paper deals with the resonant type of a WEC (wave energy converter) and the determination method of its geometric parameters which were obtained to construct the robust and optimal structure, respectively. In detail, the optimization problem is formulated with the constraints composed of the response surfaces which stand for the resonance period(heave, pitch) and the meta center height of the buoy. Use of a signal-to-noise ratio calculated from normalized multi-objective results with the weight factor can help to select the robust design level. In order to get the sample data set, the motion responses of the power buoy were analyzed using the BEM (boundary element method)-based commercial code. Also, the optimization result is compared with a robust design for a feasibility study. Finally, the power efficiency of the WEC with the optimum design variables is estimated as the captured wave ratio resulting from absorbed power which mainly related to PTO (power take off) damping. It could be said that the resultant of the WEC design is the economical optimal design which satisfy the given constraints.

Effects of Organic and Inorganic Additives on Selective Non Catalytic Reduction Reaction of NOx in a Pilot Scale Flow Reactor (파일럿 규모의 흐름반응기에서 유기 및 무기 첨가제가 질소산화물의 선택적 무촉매 환원반응에 미치는 영향)

  • Park, Soo Youp;Yoo, Kyung Seun;Lee, Joong Kee;Park, Young Kwon
    • Korean Chemical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.540-546
    • /
    • 2006
  • Effects of organic and inorganic additives on the SNCR reaction of NOx were investigated in a pilot scale flow reactor with a variation of operating parameters. NOx reduction efficiency increased with the increase of a residence time and an initial NOx concentration. NOx reduction reaction by urea solution started to appear about 850 and then reached to maximum value around $970^{\circ}C$. NOx reduction efficiency also increased with the increase of NSR (Normalized Stoichiometric Ratio) up to 2.0. Addition of ethanol and phenol as an organic additives shifted the optimum temperature window to lower region with decreasing the maximum NOx reduction efficiency. This might be due to the side reaction of hydrocarbon in ethanol structure. NaOH addition widened the temperature window and enhanced the NOx reduction efficiency about 10% due to the chain reaction of NaOH and the reduction of $N_2O$.

Parametric Study on Design Variables of Concrete Beam Reinforced with GFRP Rebar using Finite Element Analysis (유한요소해석에 의한 GFRP 보강 콘크리트 보의 설계인자 분석)

  • Moon, Do-Young;Oh, Hong-Seob;Ahn, Kwang-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.357-367
    • /
    • 2008
  • Parametric study of beams with reinforced with FRP rebar is conducted in this study. Using ABAQUS program, the finite element analysis model is set and calibrated with the experimental results which have been conducted by the authors. The employed design parameters are reinforcement ratio, elastic modulus of rebar, and concrete strength. The obtained results from FE analysis are investigated in terms of normalized beam stiffness. In particular, the effect of reinforcement ratio on the flexural stiffness is investigated with comparing with the model code specified on ACI 440. From the analysis results, the reinforcement ratio in beam is the first parameter affecting on the beam stiffness. In addition, its effect could be increased with higher concrete strength.

Static and Dynamic Fracture Analysis for the Interface Crack of Isotropic-Orthotropic Bimaterial

  • Lee, Kwang-Ho;Arun Shukla;Venkitanarayanan Parameswaran;Vijaya Chalivendra;Hawong, Jae-Sug
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.165-174
    • /
    • 2002
  • In the present study, interfacial cracks between an isotropic and orthotropic material, subjected to static far field tensile loading are analyzed using the technique of photoelasticity. The fracture parameters are extracted from the full-field isochromatic data and the same are compared with that obtained using boundary collocation method. Dynamic photoelasticity combined with high-speed digital photography is employed for capturing the isochromatics in the case of propagating interfacial cracks. The normalized stress intensity factors for static cracks are greate. when ${\alpha}$: 90$^{\circ}$(fibers perpendicular to the interface) than when ${\alpha}$=0$^{\circ}$(fibers parallel to the interface), and those when ${\alpha}$=90$^{\circ}$are similar to ones of isotropic material. The dynamic stress intensity factors for interfacial propagating cracks are greater when ${\alpha}$=0$^{\circ}$ than ${\alpha}$=90$^{\circ}$. For the velocity ranges (0.1 < C/C$\sub$s1/<0.7) observed in this study, the complex dynamic stress intensity factor │K$\sub$D/│increases with crack speed c, however, the rate of increase of │K$\sub$D/│with crack speed is not as drastic as that reported for homogeneous materials.

A Drug-Induced Liver Injury by Western Medication (양약으로 유발된 약인성 간손상 환자 임상보고)

  • Son, Chang-gue
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.1
    • /
    • pp.69-75
    • /
    • 2015
  • Objectives : To investigate the clinical features of drug-induced liver injury (DILI) and traditional Korean medicine (TKM) -based management. Methods : A female patient diagnosed with DILI caused by Western drugs had been treated with Oriental therapies, then the subjective clinical outcome and biochemical parameters were monitored. Results : A 73-year-old female had taken Western drugs (nonsteroidal anti-inflammatory and skeletal muscle relaxants) for about 3 months, and complained of severe abdominal discomfort and tiredness. Her RUCAM score was 9, which met the criteria for DILI (AST 90 IU/L, ALT 100 IU/L, ALP 191 IU/L, and GGT 614 IU/L). She was treated with herbal drugs, moxibustion, and acupuncture, and her symptoms completely resolved, with normalized hepatic enzymes within two weeks. Conclusions : This case report provides a clinical characteristic for a typical DILI caused by Western medicine, and shows an example of a TKM-based application.

Modal testing and finite element model calibration of an arch type steel footbridge

  • Bayraktar, Alemdar;Altunisk, Ahmet Can;Sevim, Baris;Turker, Temel
    • Steel and Composite Structures
    • /
    • v.7 no.6
    • /
    • pp.487-502
    • /
    • 2007
  • In recent decades there has been a trend towards improved mechanical characteristics of materials used in footbridge construction. It has enabled engineers to design lighter, slender and more aesthetic structures. As a result of these construction trends, many footbridges have become more susceptible to vibrations when subjected to dynamic loads. In addition to this, some inherit modelling uncertainties related to a lack of information on the as-built structure, such as boundary conditions, material properties, and the effects of non-structural elements make difficult to evaluate modal properties of footbridges, analytically. For these purposes, modal testing of footbridges is used to rectify these problems after construction. This paper describes an arch type steel footbridge, its analytical modelling, modal testing and finite element model calibration. A modern steel footbridge which has arch type structural system and located on the Karadeniz coast road in Trabzon, Turkey is selected as an application. An analytical modal analysis is performed on the developed 3D finite element model of footbridge to provide the analytical frequencies and mode shapes. The field ambient vibration tests on the footbridge deck under natural excitation such as human walking and traffic loads are conducted. The output-only modal parameter identification is carried out by using the peak picking of the average normalized power spectral densities in the frequency domain and stochastic subspace identification in the time domain, and dynamic characteristics such as natural frequencies mode shapes and damping ratios are determined. The finite element model of footbridge is calibrated to minimize the differences between analytically and experimentally estimated modal properties by changing some uncertain modelling parameters such as material properties. At the end of the study, maximum differences in the natural frequencies are reduced from 22% to only %5 and good agreement is found between analytical and experimental dynamic characteristics such as natural frequencies, mode shapes by model calibration.

Analysis and Implementation of a Half Bridge Class-DE Rectifier for Front-End ZVS Push-Pull Resonant Converters

  • Ekkaravarodome, Chainarin;Jirasereeamornkul, Kamon
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.626-635
    • /
    • 2013
  • An analysis of the junction capacitance in resonant rectifiers which has a significant impact on the operating point of resonance circuits is studied in this paper, where the junction capacitance of the rectifier diode is to decrease the resonant current and output voltage in the circuit when compared with that in an ideal rectifier diode. This can be represented by a simplified series resonant equivalent circuit and a voltage transfer function versus the normalized operating frequency at varied values of the resonant capacitor. A low voltage to high voltage push-pull DC/DC resonant converter was used as a design example. The design procedure is based on the principle of the half bridge class-DE resonant rectifier, which ensures more accurate results. The proposed scheme provides a more systematic and feasible solution than the conventional resonant push-pull DC/DC converter analysis methodology. To increase circuit efficiency, the main switches and the rectifier diodes can be operated under the zero-voltage and zero-current switching conditions, respectively. In order to achieve this objective, the parameters of the DC/DC converter need to be designed properly. The details of the analysis and design of this DC/DC converter's components are described. A prototype was constructed with a 62-88 kHz variable switching frequency, a 12 $V_{DC}$ input voltage, a 380 $V_{DC}$ output voltage, and a rated output power of 150 W. The validity of this approach was confirmed by simulation and experimental results.

Performance Evaluation of a Switch Router with Output-Buffer (출력 버퍼를 장착한 스위치 라우터의 성능 분석)

  • Shin Tae-zi;Yang Myung-kook
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.2
    • /
    • pp.244-253
    • /
    • 2005
  • In this paper, a performance evaluation model of the switch router with the multiple-buffered crossbar switches is proposed and examined. Buffered switch technique is well known to solve the data collision problem of the crossbar switch. The proposed evaluation model is developed by investigating the transfer patterns of data packets in a switch with output-buffers. The performance of the multiple-buffered crossbar switch is analyzed. Steady state probability concept is used to simplify the analyzing processes. Two important parameters of the network performance, throughput and delay, are then evaluated. To validate the proposed analysis model, the simulation is carried out on a network that uses the multiple buffered crossbar switches. Less than $2\%$ differences between analysis and simulation results are observed. It is also shown that the network performance is significantly improved when the small number of buffer spaces is given. However, the throughput elevation is getting reduced and network delay becomes increasing as more buffer spaces are added in a switch.

Phase-resolved CARS Temperature Measurements in a Lean Premixed Gas Turbine Combustor (2);Effect of equivalence ratio on phase-resolved gas temperature (CARS를 이용한 희박 예혼합 가스터빈 연소기내 온도 측정 (2);당량비가 위상별 온도에 미치는 영향)

  • Lee, Jong-Ho;Moon, Gun-Feel;Park, Chul-Woong;Hahn, Jae-Won;Jeon, Chung-Hwan;Chang, Young-June
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.103-108
    • /
    • 2003
  • The effect of equivalence ratio and fuel/air mixing quality on the phase-resolved gas temperatures at different phases of the oscillating pressure cycle was experimentally investigated. An atmospheric pressure, optically accessible and laboratory-scale dump combustor operating on methane with heat release rate of 1.59kW was used. Temperature measurements were made using coherent anti-Stokes Raman spectroscopy (CARS) at several spatial locations for typical unstable combustion conditions. Analysis was conducted using parameters such as phase-resolved averaged temperature, normalized standard deviation and temperature probability distribution functions (PDFs). Also the probability on the occurrence of high temperature (over 1900K) was investigated to get the information on the perturbation of equivalence ratio and NOx emission characteristics. It was shown that most of temperature histograms exhibit Gaussian profile which has short breadth of temperature fluctuation at equivalence ratio of 0.6, while beta profile was predominant for the cases of other equivalence ratios (${\Phi}$=0.55, 0.50). The characteristics on the occurrence of high temperature also displayed periodic wave form which is very similar to the pressure signal. And the amplitude of this profile goes larger as the fuel/air mixing quality become poorer. These also provided additional information on the perturbation of equivalence ratio at flame as well as NOx emission characteristics.

  • PDF

Removal of nitrogen and sulfur odorous compounds and their precursors using an electrolytic oxidation process (산화전리수를 이용한 질소와 황 계열 악취 및 악취전구물질의 제거)

  • Shin, Seung-Kyu;An, Hea-Yung;Kim, Han-Seung;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.223-230
    • /
    • 2011
  • An electrolytic oxidation process was applied to remove odorous compounds from non-point odor sources including wastewater pipelines and manholes. In this study, a distance between the anode and the cathode of the electrolytic process was varied as a system operating parameters, and its effects on odor removal efficiencies and reaction characteristics were investigated. Odor precursors such as sediment organic matters and reduced sulfur/nitrogen compounds were effectively oxidized in the electrolytic process, and a change in oxidation-reduction potential (ORP) indicated that an stringent anaerobic condition shifted to a mild anoxic condition rapidly. At an electrode distance of 1 cm and an applied voltage of 30 V, a system current was maintained at 1 A, and the current density was 23.1 $mA/cm^{2}$. Under the condition, the removal efficiency of hydrogen sulfide in gas phase was found to be 100%, and 93% of ammonium ion was removed from the liquid phase during the 120 minute operating period. Moreover, the sulfate ion (${SO_4}^{2-}$) concentration increased about three times from its initial value due to the active oxidation. As the specific power consumption (i.e., the energy input normalized by the effective volume) increased, the oxidation progressed rapidly, however, the oxidation rate was varied depending on target compounds. Consequently, a threshold power consumption for each odorous compound needs to be experimentally determined for an effective application of the electrolytic oxidation.