• Title/Summary/Keyword: Normal value

Search Result 3,443, Processing Time 0.025 seconds

Effect of One Leg Bridge Exercise with Abdominal Pressure Control on the Trunk Muscle Activation in Healthy Adults

  • Jeong, Seunghoon;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.253-258
    • /
    • 2022
  • Objective: This study aimed to determine the effect of internal abdominis pressure(normal, hollowing and bracing) on trunk muscle activity during one leg bridge exercise. Design: Cross-sectional study. Methods: Thirteen healthy adults (9 men and 4 women) were instructed to perform Internal abdominal pressure(IAP) control(Normal, Hollowing, Bracing) during one leg bridge. Electromyography (EMG) data (% Maximum Voluntary Isometric Contraction, MVIC) were recorded three times on both sides of the participant's Internal Oblique(IO), Effector Spinae(ES), and Multifidus(MF) muscles and the average value was analyzed. Results: As a result, Abdominal bracing one leg bridge (BOLB) group and Abdominal hollowing one leg bridge (HOLB) group showed significantly increased muscle activation of bilateral internal oblique, erector spinae and multifidus activation compared to the Normal one leg bridge (NOLB) group (p<0.05). Abdominal hollowing one leg bridge (HOLB) group had a significant difference in bilateral Internal oblique muscle activation in compared to the NOLB group (p<0.05). Conclusions: Bilateral internal oblique, erector spinae, and multifidus muscles activation in healthy adults at one leg bridge exercise showed greater activation at abdominal bracing. Therefore, in this study, IAP control can be used as an indicator of choice to the dysfunction with trunk muscle weakness and corrective exercise subject's situation when the goal is to activate the trunk muscles by performing one leg bridge.

Analysis of the thermal instability of laminated composite plates

  • H. Mataich;A. El Amrani;B. El Amrani
    • Coupled systems mechanics
    • /
    • v.13 no.2
    • /
    • pp.95-113
    • /
    • 2024
  • In this paper, we will analyse the thermo-elastic behavior of the plate element of a structure arranged in a climatically aggressive environment (extreme temperature), we use a refined four-variable thick plate theory to take the shear effect into consideration, the proposed theory less computationally expensive and more accurate so that it incorporates the shear effect into the formulation. The plate is assumed to be simply supported on its four edges, so exact (closed-form) solutions are found according to the Navier expansion, and the governing stability equations and associated boundary conditions of the problem are obtained via the virtual works principle. The plate studied ismade of laminated composite materials, so a parametric study is needed to see the effect of different types of parameters and coupling on the critical temperature value causing thermo-elastic instability of the plate and also on the natural frequency of free vibration, as well as for other parameters such as anisotropy, slenderness and aspect ratio of the plate and finally the lamination angle. Numerical results are obtained for specially orthotropic and antisymmetrical plates and are compared with those obtained by othertheoriesin the literature to validate the analysis approach used.

An Efficient PSI-CA Protocol Under the Malicious Model

  • Jingjie Liu;Suzhen Cao;Caifen Wang;Chenxu Liu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.18 no.3
    • /
    • pp.720-737
    • /
    • 2024
  • Private set intersection cardinality (PSI-CA) is a typical problem in the field of secure multi-party computation, which enables two parties calculate the cardinality of intersection securely without revealing any information about their sets. And it is suitable for private data protection scenarios where only the cardinality of the set intersection needs to be calculated. However, most of the currently available PSI-CA protocols only meet the security under the semi-honest model and can't resist the malicious behaviors of participants. To solve the problems above, by the application of the variant of Elgamal cryptography and Bloom filter, we propose an efficient PSI-CA protocol with high security. We also present two new operations on Bloom filter called IBF and BIBF, which could further enhance the safety of private data. Using zero-knowledge proof to ensure the safety under malicious adversary model. Moreover, in order to minimize the error in the results caused by the false positive problem, we use Garbled Bloom Filter and key-value pair packing creatively and present an improved PSI-CA protocol. Through experimental comparison with several existing representative protocols, our protocol runs with linear time complexity and more excellent characters, which is more suitable for practical application scenarios.

Relationship between Normal Measurement and Error Rate of Output Voltage Linear Ratio of Seismic Accelerometer in Use (사용 중 지진 가속도계의 정상 측정과 출력전압 선형비 오차율 관계 분석)

  • Min-Jun Kim;Seong-Cheol Cho;Yong-Hun Jung;Jeong-Hun Won
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.65-74
    • /
    • 2024
  • We analyzed the relationship between the normal measurement of the seismic accelerometer (SA) and the error rate of the output voltage linear ratio to propose an evaluation method to determine whether the SA in use is measuring normally. Utilizing a test bed, the regular operation of SA in use was evaluated using acceleration data measured through impact tests since there are no regulations regarding performance testing of SA in use. For the used SA, the error rate of the output voltage linear ratio, which is a major performance criterion, was evaluated. We analyzed common characteristics of the SA that satisfied the impact test and the performance criteria of the output voltage linear ratio error rate. The results indicated that we must consider the decreasing trend and convergence of the error rate as the measurement angle increases, ensuring that the average value of the output voltage linear ratio error rate is within 1%.

Should Voiding Cystourethrography be Performed for Infants with Urinary Tract Infection? (요로감염 영아에서 배뇨성방광요도조영술이 필요한가?)

  • Woo, Mi-Kyeong;Kim, Mun-Sub;Koo, Ja-Wook
    • Childhood Kidney Diseases
    • /
    • v.12 no.1
    • /
    • pp.54-61
    • /
    • 2008
  • Purpose: This study was performed to assess necessity of voiding cystourethrography (VCUG) for infants with urinary tract infection (UTI) who had both normal renal sonography and normal DMSA renal scans. Methods: We reviewed 117 infants hospitalized for UTI between February 2002 and July 2007 at Sanggye Paik Hospital. The diagnosis of UTI was made by culture from a urine specimen obtained by suprapubic puncture(n=57), catheterization(n=58), or collection bag method (n=2, twice positive culture of the same organism). All patients had undergone renal sonography, DMSA renal scan and VCUG. Children with both normal renal sonography and normal DMSA renal scans were evaluated for the presence or severity of vesicoureteral reflux (VUR). Results: Of the 117 patients, 96 were boys and 21 were girls. 28 patients(23.9%) had VUR. 59(50.4%) showed both normal renal sonography and normal DMSA renal scans. Among these 59 patients, 7(11.9%) showed VUR. Three of them had grade I-II reflux, two grade III reflux, and the other two grade IV reflux. One of them showed bilateral VUR, grade IV reflux on the right and grade III on the left. Conclusion: Although the negative predictive value of both normal renal sonography and normal DMSA renal scan for VUR was 88.1%, 7 patients had VUR and two of them had high grade reflux(grade IV). So, we suggest that VCUG should be performed in infants with UTI despite both normal renal sonography and normal DMSA renal scans.

  • PDF

A SES Alarmed Link Encryption Synchronization Method Having Optimized Threshold Value for High-Speed Video Data Encryption

  • Kim, Hyeong-Rag;Lee, Hoon-Jae;Kim, Ki-Hwan;Jung, Ju-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.57-64
    • /
    • 2017
  • CCSDS Standard is widely used in the international space telecommunication area. But standard recommendation of CCSDS is not restrictive, so, we can select an appropriate encryption protocol among the layer. For synchronization, encryption sync is attached in the beginning of the encrypted data. In the exceptional environmental condition, although the receiver can not decrypt the normal data, the sender have no conception of that situation. In this paper, we propose a two-stage SES alarmed link encryption synchronization method having optimized threshold value necessary to decide whether the receiver has a correct decryption or not. first, through the experiment of mutual relations between error rate and encryption synchronization detection error, we can predict worst communication environment for the selected encryption synchronization pattern. second, through the experiment for finding what number of consecutive frame synchronization error is an appropriate reference value and analysis of that experiment, we suggest an optimized threshold value for resynchronization request. lastly, through the output images we can predict the probability error that should be guaranteed by channel coder.

A frictionless contact problem for two elastic layers supported by a Winkler foundation

  • Birinci, Ahmet;Erdol, Ragip
    • Structural Engineering and Mechanics
    • /
    • v.15 no.3
    • /
    • pp.331-344
    • /
    • 2003
  • The plane contact problem for two infinite elastic layers whose elastic constants and heights are different is considered. The layers lying on a Winkler foundation are acted upon by symmetrical distributed loads whose lengths are 2a applied to the upper layer and uniform vertical body forces due to the effect of gravity in the layers. It is assumed that the contact between two elastic layers is frictionless and that only compressive normal tractions can be transmitted through the interface. The contact along the interface will be continuous if the value of the load factor, ${\lambda}$, is less than a critical value. However, interface separation takes place if it exceeds this critical value. First, the problem of continuous contact is solved and the value of the critical load factor, ${\lambda}_{cr}$, is determined. Then, the discontinuous contact problem is formulated in terms of a singular integral equation. Numerical solutions for contact stress distribution, the size of the separation areas, critical load factor and separation distance, and vertical displacement in the separation zone are given for various dimensionless quantities and distributed loads.

Determination of epidemiological tetracycline MIC cut-off value for Vibrio ichthyoenteri

  • Han, Hyun-Ja;Kim, Do-Hyung;Lee, Deok-Chan;Won, Kyoung-Mi;Lee, Soon-Jeong;Cho, Mi-Young;Jee, Bo-Young;Kim, Jin-Woo
    • Journal of fish pathology
    • /
    • v.24 no.2
    • /
    • pp.95-102
    • /
    • 2011
  • Normalized resistance interpretation (NRI) analysis for tetracycline was applied to generate information on the epidemiological cut-off value for Vibrio ichthyoenteri isolated from diseased olive flounder (Paralichthys olivaceus) larvae. Thus, 42 strains of V. ichthyoenteri were used to determine minimum inhibitory concentration (MIC) values of tetracycline using Etest. Also, 11 tetracycline resistance related genes were investigated by PCR method. Most tetracycline-resistant strains harbored both tetB and tetM with a few exceptions. NRI-derived mean and 2 SD above the mean of theoretical normal distributions of susceptible isolates were 0.33 mg/L and 1.66 mg/L, respectively. The epidemiological cut-off value for V. ichthyoenteri from the calculations could be set to S ${\leq}$ 2 mg/L. Of the 42 strains, 15 were classified as non-wild type (NWT), and MIC values of the NWT strains vary regardless of tetB and tetM detection, suggesting that there may be other mechanisms involved in tetracycline resistance in this Vibrio species.

Quality and Storage Characteristics of Pork Teokgalbi with Added Rosemary (Rosemarinus officinalis) Extract Powder (로즈마리 추출분말을 첨가한 돈육 떡갈비의 품질 및 저장특성)

  • Jung, Hae-Ok;Lee, Jae-Joon
    • The Korean Journal of Community Living Science
    • /
    • v.27 no.3
    • /
    • pp.509-520
    • /
    • 2016
  • This study was carried out to investigate the effects of adding rosemary extract powder (REP) to pork teokgalbi on its quality and storage characteristics. Five types of teokgalbi were tested, viz. with no REP added (normal, N), with 0.05% ascorbic acid added (control, C) and with 0.05% (R1), 0.1% (R2) and 0.2% (R3) of REP added. The proximate composition, calorific value, water holding capacity and cooking loss were not significantly different among the different types of pork teokgalbi. The L and a values of the teokgalbi containing REP were significantly lower than those of the N and C groups. As regards the textural characteristics, the addition of 0.2% REP increased the springiness value. In the sensory evaluation, the teokgalbi with the addition of 0.1% REP had higher scores in flavor and total acceptability. The 2-thiobarbituric acid (TBA) value, total microbial count and volatile basic nitrogen content of the teokgalbi containing 0.2% REP were lower than those of the N group. In conclusion, R3 was significantly more effective in delaying lipid peroxidation than the other treatment groups. Therefore, rosemary extract could be used as a natural antioxidant in meat products.

An Experimental Study on Effect on Debonding Strength of Metal-porcelain by Painting Method of Opaque Porcelain (Opaque 도재의 도포 방법에 따른 금속-도재의 결합강도에 미치는 영향에 관한 실험적 연구)

  • Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.39-47
    • /
    • 2000
  • This study is the know the difference bond strength according to painting method of Opaque porcelain. Among Porcelain powder for Porcelain, Noritake powder, Bonding agent 1 class and metal are selected as Base metal alloy. And painting method of Opaque porcelain is divided by 4 groups : PG, WG, NG and DG. Also it is to manufacture 24 sheets of Specimen by 6 each every method and to measure Crack-initiation Strength of Metal-porcelain and it is to observe it by Scanning electron microscope. I come to get a conclusion as follows. 1. As for Debonding strength of every experiment groups, it showed that WS group which executed Wash bake had highest value, 44.25MPa and NG group which used Normal powder had value, 42.11MPa and DG group which used Bonding agent had value, 35.88MPa and PG group which used Paste opaque had value, 35.39MPa. 2. In four painting methods of Opaque porcelain, PG group, WG group, NG group and DG group, there is no significant difference statistically in Crack-initiation Strength. 3. As a result of observing fracture surface with Scanning electron microscope, it was showde that PG group remained a lot of particle of porcelain on the surface of metal than WG group, NG group and DG group.

  • PDF