• Title/Summary/Keyword: Normal value

Search Result 3,429, Processing Time 0.028 seconds

Psychosocial Stress Levels and Related Factors in some Rural Residents (일부 농촌지역 주민에서 사회심리적 스트레스 수준과 관련요인)

  • Han, Mi-Ah;Kim, Ki-Soon;Park, Jong;Ryu, So-Yeon;Kang, Myung-Geun
    • Journal of agricultural medicine and community health
    • /
    • v.33 no.1
    • /
    • pp.46-58
    • /
    • 2008
  • Objectives: This study was performed to investigate the levels of psychosocial stres and to identify its Methods: The study subjects were 1,806 adults aged 40-70 years living in Naju City, Jeollanamdo. Sociodemographic characteristics, health-related behavior, social suport and personality were collected for statistical analysis. The measurement instrument of psychosocial stress was psychosocial well-being index. The regression analysis. Results: The results showed that 16.6% of subjects were categorized as high stress, 63.4% as moderate, and 20.0% as normal. Overall, the mean value of PWI was 17.29.8 and significantly diferent by socioeconomic characteristics, health-related behavior, social suport and personality. In the case of men, the income, decreased positive social suport, increased negative social suport, type A behavior pattern, decrease of internal locus of control or poorer self-esteem. In the case of women, the PWI was significantly deteriorated in the subjects with no job, no spouse, decreased positive social suport, increased negative social support, type A behavior pattern, decrease of internal locus of control or poorer self-esteem.Conclusions: The psychosocial stres for rural residents was related with social suport and personality. Thus, these results should be considered to reduce stres levels in rural adults.

Time-series Mapping and Uncertainty Modeling of Environmental Variables: A Case Study of PM10 Concentration Mapping (시계열 환경변수 분포도 작성 및 불확실성 모델링: 미세먼지(PM10) 농도 분포도 작성 사례연구)

  • Park, No-Wook
    • Journal of the Korean earth science society
    • /
    • v.32 no.3
    • /
    • pp.249-264
    • /
    • 2011
  • A multi-Gaussian kriging approach extended to space-time domain is presented for uncertainty modeling as well as time-series mapping of environmental variables. Within a multi-Gaussian framework, normal score transformed environmental variables are first decomposed into deterministic trend and stochastic residual components. After local temporal trend models are constructed, the parameters of the models are estimated and interpolated in space. Space-time correlation structures of stationary residual components are quantified using a product-sum space-time variogram model. The ccdf is modeled at all grid locations using this space-time variogram model and space-time kriging. Finally, e-type estimates and conditional variances are computed from the ccdf models for spatial mapping and uncertainty analysis, respectively. The proposed approach is illustrated through a case of time-series Particulate Matter 10 ($PM_{10}$) concentration mapping in Incheon Metropolitan city using monthly $PM_{10}$ concentrations at 13 stations for 3 years. It is shown that the proposed approach would generate reliable time-series $PM_{10}$ concentration maps with less mean bias and better prediction capability, compared to conventional spatial-only ordinary kriging. It is also demonstrated that the conditional variances and the probability exceeding a certain thresholding value would be useful information sources for interpretation.

A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation (실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

Diagnostic Accuracy of 18F-FDG-PET in Patients with Testicular Cancer: a Meta-analysis

  • Zhao, Jing-Yi;Ma, Xue-Lei;Li, Yan-Yan;Zhang, Bing-Lan;Li, Min-Min;Ma, Xue-Lei;Liu, Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3525-3531
    • /
    • 2014
  • Objective: Fluorine-18-fluorodeoxyglucose positron emission tomography (18F-FDG-PET) is a new technique for identifying different malignant tumors using different uptake values between tumor cells and normal tissues. Here we assessed the diagnostic accuracy of 18F-FDG-PET in patients with testicular cancer by pooling data of existing trials in a meta-analysis. Methods: PubMed/MEDLINE, Embase and Cochrane Central Trials databases were searched and studies published in English relating to the diagnostic value of FDG-PET for testicular cancer were collected. The summary receiver operating characteristic (SROC) curve was used to examine the FDG-PET accuracy. Results: A total of 16 studies which included 957 examinations in 807 patients (median age, 31.1 years) were analyzed. A meta-analysis was performed to combine the sensitivity and specificity and their 95% confidence intervals (CIs), from diagnostic odds ratio (DOR), positive likelihood ratios (PLR), negative likelihood ratio (NLR). SROC were derived to demonstrate the diagnostic accuracy of FDG-PET for testicular cancer. The pooled sensitivity and specificity were 0.75 (95% confidence interval (CI), 0.70-0.80) and 0.87 (95% CI, 0.84-0.89), respectively. The pooled DOR was 35.6 (95% CI, 12.9-98.3). The area under the curve (AUC) was 0.88. The pooled PLR and pooled NLR were 7.80 (95% CI, 3.73-16.3) and 0.31 (95% CI, 0.23-0.43), respectively. Conclusion: In patients with testicular cancer, 18F-FDG-PET demonstrated a high SROC area, and could be a potentially useful tool if combined with other imaging methods such as MRI and CT. Nevertheless, the literature focusing on the use of 18F-FDG-PET in this setting still remains limited.

A Study on Reliability Based Design Criteria for Reinforced Concrete Bridge Superstructures (철근(鐵筋)콘크리트 도로교(道路橋) 상부구조(上部構造) 신뢰성(信賴性) 설계규준(設計規準)에 관한 연구(研究))

  • Cho, Hyo Nam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.3
    • /
    • pp.87-99
    • /
    • 1982
  • This study proposes a reliability based design criteria for the R.C. superstructures of highway bridges. Uncertainties associated with the resistance of T or rectangular sections are investigated, and a set of appropriate uncertainties associated with the bridge dead and traffic live loads are proposed by reflecting our level of practice. Major 2nd moment reliability analysis and design theories including both Cornell's MFOSM(Mean First Order 2nd Moment) Methods and Lind-Hasofer's AFOSM(Advanced First Order 2nd Moment) Methods are summarized and compared, and it has been found that Ellingwood's algorithm and an approximate log-normal type reliability formula are well suited for the proposed reliability study. A target reliability index (${\beta}_0=3.5$) is selected as an optimal value considering our practice based on the calibration with the current R.C. bridge design safety provisions. A set of load and resistance factors is derived by the proposed uncertainties and the methods corresponding to the target reliability. Furthermore, a set of nominal safety factors and allowable stresses are proposed for the current W.S.D. design provisions. It may be asserted that the proposed L.R.F.D. reliability based design criteria for the R.C. highway bridges may have to be incorporated into the current R.C. bridge design codes as a design provision corresponding to the U.S.D. provisions of the current R.C. design code.

  • PDF

Antropometric and Health Status of the Elderly Women Attending a Health Promotion Program in an Urban Community (건강증진프로그램을 이용하는 도시지역 여자노인의 신체 및 건강수준)

  • 권진희;윤희정;문효정;이재무;손윤희;박성화;이희경;이성국
    • Korean Journal of Community Nutrition
    • /
    • v.7 no.6
    • /
    • pp.762-768
    • /
    • 2002
  • This study was conducted to evaluate the health status of elderly women who attended in a Health Promotion Program of the Seo-gu Health Center in Daegu. The study subjects were 158 elderly women (over 65 years) in an urban community. The subjects were investigated by means of individual interviews using a questionnaire, Blood tests for analyzing their biochemical status were carried out. The average age of the study subjects was 70.9 $\pm$ 2.3 years. Of the subject group 79.1% ranged in age from 65 to 74 year and 20.9% were over 75 years. With respect to health related factors, 23.4% of subjects drank alcoholic beverages and 15.2% of subjects currently smoke.The prevalence with chronic diseases was 51.9%, and 26.6% of the subjects were healthy. The diseases most frequently reported as having been or being treated were arthritis (38.1%), hypertension (21.4%), and diabetes (17.9%). The average height of subjects was below the standard established in the Korean Recommended Dietary Allowances, while the average weight was close to the standard. The means of systolic and diastolic blood pressure were 130.2 mmHg and 71.9 mmHg, respectively. The mean serum albumin level was 4.5 mg/d$\ell$ and the value of hemoglobin and hematocrit was 12.5 mg/d$\ell$ and 0.7%, respectively. The mean serum cholesterol level was 207.1 mg/d$\ell$ and the mean triglyceride level was 187.7 mg/d$\ell$. The serum lipid levels were higher then in those reported in research. The serum cholesterol levels of 71.5% of subjects were within the normal range. The GOT and GTP levels were within the moderate range. In conclusion, the health status of the elderly who attended the Health Promotion Program in the Seo-gu Health Center were very average. However, it was necessary to prepare a health management program to deal with the serum lipids so as to establish and maintain good health. When we carry out the health promotion program in a community, individual program Of adequate to health status should be developed more.

Study on mechanical behaviors of large diameter shield tunnel during assembling

  • Feng, Kun;Peng, Zuzhao;Wang, Chuang;He, Chuan;Wang, Qianshen;Wang, Wei;Cao, Songyu;Wang, Shimin;Zhang, Haihua
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.623-635
    • /
    • 2018
  • In order to study the mechanical behavior of shield tunnel segments during assembly stage, the in-situ tests and FDM numerical simulation were conducted based on the Foguan Shiziyang Tunnel with large cross-section. Analysis for the load state of the assembling segments in different assembly steps as well as the investigation for the changing of inner forces and longitudinal stress of segments with assembling steps were carried out in this paper. By comparing the tested results with the simulated results, the conclusions and suggestions could be drawn as follows: (1) It is the most significant for the effects on axial force and bending moment caused by the assembly of adjacent segment, followed by the insertion of key segment while the effects in the other assembly steps are relative smaller. With the increasing value of axial force, the negative bending moment turns into positive and remains increasing in most monitored sections, while the bending moment of segment B1and B6 are negative and keeping increasing; (2) The closer the monitored section to the adjacent segments or the key segment, the more significant the internal forces response, and the monitored effects of key segment insertion are more obvious than that of calculation; (3) The axial forces are all in compression during assembling and the monitored values are about 1.5~1.75 times larger than the calculated values, and the monitored values of bending moment are about 2 times the numerical calculation. The bending moment is more sensitive to the segments assembly process compared with axial force, and it will result in the large bending moment of segments during assembling when the construction parameters are not suitable or the assembly error is too large. However, the internal forces in assembly stage are less than those in normal service stage; (4) The distribution of longitudinal stress has strong influence on the changing of the internal forces. The segment side surface and intrados in the middle of two adjacent jacks are the crack-sensitive positions in the early assembly stage, and subsequently segment corners far away from the jacks become the crack-sensitive parts either.

BIOASSAY STUDY OF EARLY DEVELOPMENT OF MACTRA CHINENSIS PHILIPPI FOR THE WATER QUALITY EVALUATION OF THE COASTAL WATERS OF BUSAN (개량조개, Mactra chinensis Philippi 발생에 의한 부산연안 해수의 수질오탁 조사)

  • LEE Taek Yuil;SON Young Won
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.2
    • /
    • pp.115-121
    • /
    • 1978
  • Early developmental stages of Mactra chinensis were bioassayied to determin the water quality of the costal waters of Busan. The water samples were obtained at 12 stations from July 12 to July 17, 1977. Water quality evaluation was made in terms of the rates of normal development to abnormal development in three indicatory states, i. e. fertilization membrane formation, morula and trochophore larvae. The pollution degree of the waters brought from five swimming beaches was found to be highest at Haewundae followed by Songdo, Kwang-anri, Songjeong and Dadaepo with decreasing order. The highest value of the water at Haewundae was mainly due to the accidental oil spill from an oil tanker which happened on July 7, 1977. At Dongsamdong the rate of total abnormal development was $47.17\%$. This result is apparently attributable to fish byproducts discarded from a number of restaurants. At Chungmudong where a large fish-market is located, the rate of total abnormal development was $61.14\%$. At Suyeng Bay and Yongho Bay the rates of total abnormal development were $73.82\%$ and $72.90\%$ respectively. At these bays the drainage presumably contains a large amount of chemical pollutants from the industrial areas. This result shows that no organisms can normally breed in these regions.

  • PDF

Comparison Measurement Error of T-score Between Lumbar and Femoral Neck According to Kind of DXA (DXA측정기 종류에 따른 요추부와 대퇴경부 골밀도 값의 측정오차 비교)

  • Han, Beom-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan;Lee, Hye-Nam;Jeong, Cheon-Soo;Lee, Sang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.250-257
    • /
    • 2010
  • In this study, three different devices, Norland, Osteocore and Lunar were used to compare and analyze the measurement error by each bone density measurement device by classifying the physical characteristics into age, height and weight, the subject of total 300 sampling 100 persons for each device. Categorizing Lumbar region and Femoral neck as normal (T-score$\geqq$-1.0), osteopenia (-1.0>T-score>-2.5) and osteoporosis (T-score$\leqq$-2.5), the findings were observed as follows. Norland device showed the least measurement error in age and height, while Lunar showed the least in weight among the devices. And, the result of comparing the bone density measurement error based on the lumbar region showed that all of Lunar, Norland and Osteocore have the least variation of measurement error in osteopenia and the result of comparing based on the femoral neck showed that all of Lunar, Norland and Osteocore have the least variation of measurement error in osteoporosis. For each variable, the measurement error was observed to be vary upon the device. To solve this, standardized common Phantom should be used to compare and converge the measured value of each company and cross-calibration would be necessary when replacing the software.

Association between Glycemic Index, Glycemic Load, Dietary Carbohydrates and Diabetes from Korean National Health and Nutrition Examination Survey 2005 (2005 국민건강영양조사 자료 분석을 통한 한국 성인 남녀의 식이 중 Glycemic Index, Glycemic Load 및 탄수화물 섭취 수준과 당뇨 발병과의 관련성 연구)

  • Kim, Eun-Kyung;Lee, Jung-Sug;Hong, Hee-Ok;Yu, Choon-Hie
    • Journal of Nutrition and Health
    • /
    • v.42 no.7
    • /
    • pp.622-630
    • /
    • 2009
  • The purpose of this study was to establish an association between glycemic index (GI), glycemic load (GL), dietary carbohydrates and diabetes with the context of the current population dietary practice in Korea. The subjects of 3,389 adults (male 1,430, female 1,959) were divided into normal (serum fasting glucose < 100 mg/dL), impaired glucose tolerance (100 ${\leq}$ serum fasting glucose < 126 mg/dL), diabetes (serum fasting glucose > 126 mg/dL) by serum fasting glucose. Anthropometric and hematologic factors, and nutrient intakes, dietary glycemic index (DGI), dietary glycemic load (DGL) were assessed. Multiple logistic regression model was used to determine the odds ratios (ORs) and 95% confidence intervals for relationship of DGI, DGL, carbohydrates intakes, and diabetes. DGI and DGL were not significantly correlated with impaired glucose tolerance and diabetes. However, the risk of impaired glucose tolerance and diabetes showed a tendency to increase as increase of DGI after multivariate adjustment (age, education, income, region area, diabetes family history, smoking, drinking, exercise, energy intake) in male. The risk of impaired glucose tolerance and diabetes showed a tendency to increase in the DGI 71.1-74.8 after multivariate adjustment in female. DGL was inversely related to impaired glucose tolerance and diabetes in male. In female, however, DGL was positively related to impaired glucose tolerance and diabetes. In particular, the risk of diabetes increased positively in level of DGL 260.5, and remained after multivariate adjustment (Q5 vs Q1:2.38, 0.87-6.48). When percent energy intakes from carbohydrates were more than 70%, the risk of impaired glucose tolerance and diabetes increased in both male and female. In particular, when percent energy intakes from carbohydrates were more than 69.9%, the risk of diabetes increased positively in male (Q4 vs Q1:2.34, 1.16-4.17). In conclusion, above 70% energy intakes from carbohydrates appeared to be a risk factor of diabetes. It seemed that the meal with high GI and GL value must be avoided it. And also, the macronutrients of the meal must be properly balanced. In particular, it may be said that it is a preventive way for treatment of the diabetes to avoid eating carbohydrates of much quantity.