• Title/Summary/Keyword: Normal temperature Fitting

Search Result 10, Processing Time 0.034 seconds

TESTS FOR VARYING-COEFFICIENT PARTS ON VARYING-COEFFICIENT SINGLE-INDEX MODEL

  • Huang, Zhensheng;Zhang, Riquan
    • Journal of the Korean Mathematical Society
    • /
    • v.47 no.2
    • /
    • pp.385-407
    • /
    • 2010
  • To study the relationship between the levels of chemical pollutants and the number of daily total hospital admissions for respiratory diseases and to find the effect of temperature/relative humidity on the admission number, Wong et al. [17] introduced the varying-coefficient single-index model (VCSIM). As pointed out, it is a popular multivariate nonparametric fitting technique. However, the tests of the model have not been very well developed. In this paper, based on the estimators obtained by the local linear technique, the average method and the one-step back-fitting technique in the VCSIM, the generalized likelihood ratio (GLR) tests for varying-coefficient parts on the VCSIM are established. Under the null hypotheses the new proposed GLR tests follow the $\chi^2$-distribution asymptotically with scale constant and degree of freedom independent of the nuisance parameters, known as Wilks phenomenon. Simulations are conducted to evaluate the test procedure empirically. A real example is used to illustrate the performance of the testing approach.

The hopping variable range conduction in amorphous InAs thin films

  • Yao, Yanping;Bo, Baoxue;Liu, Chunling
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1492-1495
    • /
    • 2018
  • This paper studies the influence of temperature on electrical resistivity in ${\alpha}-InAs$ thin films between 30 K-2K based on the analysis of Mott VRH model and ES VRH model. The effect of the interactions between electrons at lower temperature must be considered, therefore, ES VRH conduction will dominate mechanism, and the crossover from Mott to ES VRH conduction is observed about 7 K. Based on available experiment data and VRH conduction model, the parameters of VRH conduction are determined. And the calculated values of $T_C$ are consistent with the experimental results. In addition, $R_M/{\xi}$, ${\Delta}_M/kT$, $R_{ES}/{\xi}$ and ${\Delta}_{ES}/kT$ are satisfied with the validity of Mott and ES models. Furthermore, the temperature dependence of resistivity at low temperature obeys a universal scaling law, which well describes the overall temperature range of VRH conduction. However, the values of $T^{\prime}_M$ from the universal function are two order of magnitudes lower than $T_M$ deduced from fitting experiment.

Precision and accuracy of CARS spectrometer for instantaneous temperature measurement (순간 온도 측정을 위한 CARS 분광기의 정밀 정확도 분석)

  • 박승남;박철융;한재원;길용석;정석호
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.348-356
    • /
    • 1996
  • A mobile CARS spectrometer is constructed to measure the instantaneous temperature of gases, of which software include the quick fit methods and a least square fitting method to obtain temperatures from the spectra. Two quick-fit-methods give smaller variance of temperatures than the least square fitting method even though they consume much shorter time to yield temperatures. The precision and accuracy of CARS temperature is measured in the graphite tube blackbody furnace in reference to a radiation pyrometer. The accuracy of the CARS temperature is $\pm$2% from 1000K to 2400K and the precision is $\pm$35K at 1600K with the most accurate quick-fit-method. As a demonstration of the instantaneous measurement, the spectrometer is applied for measurement of the turbulent combustion at a certain condition. eograms(HS) are made using a relatively small number of synthesized 2D images. The influence of aliasing artifacts caused by insufficient or improper sampling is presented, and a new sampling theory is proposed, which is used to making holographic stereograms. Also, the optical system for extension of viewing distance and viewing zone is proposed. Results of this analysis can be applied to design normal holographic stereograms and computer based holographic stereograms.

  • PDF

THE X-RAY EMISSION FROM EARLY TYPE GALAXIES

  • Kim, Dong-Woo
    • Publications of The Korean Astronomical Society
    • /
    • v.7 no.1
    • /
    • pp.63-69
    • /
    • 1992
  • We have systematically investigated the X-ray spectra of normal galaxies, by using the Imaging Proportional Counter (IPC) data in the Einstein data base. We employed the X-ray color-color plot as well as the standard model fitting method which requires higher signal to noise ratio. We discuss X-ray emission mechanisms in terms of their spectral properties and the signature of cooling flows which are most likely present in X-ray bright early type galaxies. On the average, fits to absorbed thermal spectra show that the X-ray emission temperature of spirals is higher than that of ellipticals. This is consistent with our understanding that accreting binaries are a major X-ray source in spirals, while extended gaseous halos are present in ellipticals. The emission temperature becomes lower with increasing X-ray to optical luminosity ratio in E and S0 galaxies. This result is what we would expect if the emission of X-ray faint early type galaxies consists of a large evolved stellar component, while the gaseous emission becomes dominant in X-ray brighter galaxies. We also find a cool, self-absorbed core in some early type galaxies, which directly indicates the presence of cooling flows in such galaxies.

  • PDF

Warm Compaction: FEM Analysis of Stress and Deformation States of Compacting Dies with Rectangular Profile of Various Aspect Ratio

  • Armentani, E.;Bocchini, G. F.;Gricri, G.;Esposito, R.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.191-192
    • /
    • 2006
  • The deformation under radial pressure of rectangular dies for metal powder compaction has been investigated by FEM. The explored variables have been: aspect ratio of die profile, ratio between diagonal of the profile and die height, insert and ring thickness, radius at die corners, interference, different insert materials, i. e. conventional HSS, HSS from powders, cemented carbide (10% Co). The analyses have ascertained the unwanted appearance of tensile normal stress on brittle materials, also "at rest", and even some dramatic changes of stress patterns as the die height increases with respect to the rectangular profile dimensions. Different materials behave differently, mainly due to difference of thermal expansion coefficients. Profile changes occur when the dies are heated up to the temperature required for warm compaction. The deformation patterns depend on compaction temperature and thermal expansion coefficients.

  • PDF

Magneto-resistances of the coated conductors fabricated on the tilted single crystalline Ni substrates and RABiTS

  • Yoo, J.;Kim, H.;Jung, K.;Oh, S.;Youm, D.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.132-135
    • /
    • 2000
  • Magneto-resistances of the YBa$_2$Cu$_3$O$_{7-{\delta}}$ based coated conductors fabricated on the tilted single crystalline Ni substrates and RABiTS (rolling assisted bi-axially textured substrate) were measured under various magnetic fields. The activation energies of vortices were estimated from them by fitting equation of p = p$_o$ exp(-U(H,T)/k$_B$T). When currents flew in the rolling direction for the case of the tilted single crystalline YBCO on the RATS, the activation energies were similar to those of c-axis normal YBCO films on the SrTiO$_3$ single crystal substrates [5] and were slightly larger than those of the RABiTS coated conductors. On the contrary, for the currents flowing in the transverse direction, the magnetoresistances show double transitions in the temperature with much smaller activation energies.

  • PDF

Numerical Simulation of Pulsatile Flows around Micro-Stenosis for Blood Analog Fluids (혈액모사유체의 미세협착 주변 맥동유동 시뮬레이션)

  • Song, Jae Min;Hong, Hyeonji;Ha, Yi Kyung;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2019
  • Considering the role of viscosity in the hemorheology, the characteristics of non-Newtonian fluid are important in the pulsatile blood flows. Stenosis, with an abnormal narrowing of the vessel, contributes to block blood flows to downstream tissue and lead to plaque rupture. Therefore, systematic analysis of blood flow around stenosed vessels is crucial. In this study, non-Newtonian behaviors of blood analog fluids around the micro-stenosis with 60 % severity in diameter of $500{\mu}m$ was examined by using CFX under the pulsatile flow conditions with the period of 10 s. Viscosity information of two non-Newtonian fluids were obtained by fitting the value of normal blood and highly viscous blood. As the Newtonian fluid, the water at room temperature was used. During the pulsatile phase, wall shear stress (WSS) is highly oscillated. In addition, high viscous solution gives rise to increases the variation in the WSS around the micro-stenosis. Highly oscillating WSS enhance increasing tendency of plaque instability or rupture and damage of the tissue layer. These results, related to the influence on the damage to the endothelium or stenotic lesion, may help clinicians understand relevant mechanisms.

On the Statistical Properties of the Parameters B and q in Creep Crack Growth Law, da/dt=B(C*)q, in the Case of Mod. 9Cr-1Mo Steel (Mod. 9Cr-1Mo강의 크리프 균열 성장 법칙의 파라메터 B와 q의 통계적 성질에 관한 연구)

  • Kim, Seon-Jin;Park, Jae-Young;Kim, Woo-Gon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.3
    • /
    • pp.251-257
    • /
    • 2011
  • This paper deals with the statistical properties of parameters B and q in the creep crack growth rate (CCGR) law, da/dt=B$(C^*)^q$, in Mod. 9Cr-1Mo (ASME Gr.91) steel which is considered a candidate materials for fabricating next generation nuclear reactors. The CCGR data were obtained by creep crack growth (CCG) tests performed on 1/2-inch compact tension (CT) specimens under an applied load of 5000N at a temperature of $600^{\circ}C$. The CCG behavior was analyzed statistically using the empirical equation between CCGR, da/dt and the creep fracture mechanics parameter, $C^*$. The B and q values were determined for each specimen by the least-squares fitting method. The probability distribution functions for B and q were investigated using normal, log-normal, and Weibull distributions. As far as this study is considered, it can be appeared that B and q followed the log-normal and Weibull distributions. Moreover, a strong positive linear correlation was found between B and q.

PHOTOCATALYTIC ANTIEUNGAL ACTIVITY AGAINST CANDIDA ALBICANS BY $TiO_2$ COATED ACRYLIC RESIN DENTURE BASE

  • Yang Ji-Yeon;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.284-294
    • /
    • 2006
  • Statement of problem. Proliferation of Candida albicans is primarily within the plaque on the fitting surface of the denture rather than on the inflamed mucosa. Consequently, the treatment of the denture is equally important as treatment of the tissue. Cleansing and disinfection should be efficiently carried-out as the organisms can penetrate into the voids of the acrylic resin and grow in them, from which they can continue to infect and reinfect bearing tissues. Purpose. The purpose of this study was to evaluate the applicability of photocatalytic reaction to eliminate Candida albicans from acrylic resin denture base, and to investigate the anti-fungal effect with various UVA illumination time. Materials and Methods. The specimens were cured by the conventional method following the manufacturer's instruction using thermal polymerized denture base resin (Vertex RS: Dentimex, Netherlands). $TiO_2$ photocatalyst sol(LT), which is able to be coated at normal temperature, was made from the Ti-alkoxide progenitor. The XRD patterns, TEM images and nitrogen absorption ability of the $TiO_2$ photocatalyst sol(LT) were compared with the commercial $TiO_2$ photocatalyst P-25. The experimental specimens were coated with the mixture of the $TiO_2$ photocatalyst sol(LT) and binder material (silane) using dip-coater, and uncoated resin plates were used as the control group. Crystallinity of $TiO_2$ of the specimen was tested by the XRD. Size, shape and chemical compositions were also analyzed using the FE-SEM/ EDS. The angle and methylene blue degradation efsciency were measured for evaluating the photocatalytic activity of the $TiO_2$ film. Finally, the antifungal activity of the specimen was tested. Candida albicans KCTC 7629(1 ml, initial concentration $10^5$ cells/ ml) were applied to the experiment and control group specimens and subsequently two UVA light source with 10W, 353 nm peak emission were illuminated to the specimens from 15cm above. The extracted $2{\mu}l$ of sample was plated on nutrient agar plate ($Bacto^{TM}$ Brain Heart Infusion; BD, USA) with 10 minute intervals for 120 minute, respectively. It was incubated for 24 hours at $37^{\circ}C$ and the colony forming units (CFUs) were then counted. Results. Compared the characteristics of LT photocatalyst with commercial P-25 photocatalyst, LT were shown higher activity than P-25. The LT coated experimental specimen surface had anatase crystal form, less than 20 nm of particle size and wide specific surface area. To evaluate the photocatalytic activity of specimens, methylene blue degradation reaction were used and about 5% of degradation rate were measured after 2 hours. The average contact angle was less than $20^{\circ}$ indicating that the LT photocatalyst had hydrophilicity. In the antifungal activity test for Candida albicans, 0% survival rate were measured within 30 minute after irradiation of UVA light. Conclusion. From the results reported above, it is concluded that the UVA-LT photocatalytic reaction have an antifungal effect on the denture surface Candida albicans, and so that could be applicable to the clinical use as a cleaning method.