• Title/Summary/Keyword: Normal gait

Search Result 368, Processing Time 0.028 seconds

The Effect of Arm Swing on Gait in Healthy Adults (팔 흔들기가 정상인의 보행에 미치는 영향)

  • Jung, Hwa-Su;Choi, Su-Hee;Park, Sun-Ja;Oh, Hye-Jin;Cho, Hwa-Young
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.451-459
    • /
    • 2014
  • This study was to performed to get the reference data of the kinetic parameters for normal subjects according to the arm swing type. Forty-five normal subjects($22.62{\pm}2.69years$) pariticpated in this study and preformed 4 sequence according to the arm swing type as follows; first procedure-normal arm swing, second procedure-one arm swing, thrid procedure-no arm swing, fourth procedure-fitness arm swing. There were significant differences according to the arm swing type in the kinetic parameters such as walking speed, hip power, ground reaction force of vertical in terminal stance phase(p<.05). These finding can be utilized (a) as a reference for kinetic data of gait analysis in normal subjects, and (b) as an aide in evaluating and treating patients who have problems relating to gait.

Analysis of Kinematic Parameters of Gait in Normal Subject (정상 성인의 운동 형상학적 보행 분석)

  • Jung, Hwa-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2989-2995
    • /
    • 2014
  • This study was to performed to get the reference data of the kinematic parameters for normal subjects according to the arm movement type. Forty-five normal subjects participated in this study and preformed four sequence according to the arm movement type : normal arm movement, one arm movement, no arm movement, fitness arm movement. The study data was collected from June to August 2010. The kinematic data were measured using Vicon motion system 6MX3 cameras while each subjects walked through a 10m walkway. There were significant differences according arm movement type in the kinematic parameters such as range of motion (ROM) of the right pelvic, hip in sagittal plane, and ROM of the pelvic, hip, lumbar in coronal plane and ROM of the pelvic, thoracic, lumbar in transverse plane. This study can be utilized as the basic reference data in gait analysis for patients with pathologic gaits.

A Comparative Study on Biomechanical Variables of Elderly Women and Elderly Women at Risk of Fall in Gait by Environmental Conditions (환경조건에 따른 보행 시 낙상 위험 여성 노인과 정상 여성 노인의 생체역학적 변인 비교 연구)

  • Kim, Tae-Whan;Kim, Dae-Hyun;Min, Seok-Ki;Cho, Eun-Hyung;Lee, Jin-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.189-198
    • /
    • 2021
  • Objective: The aim of this study is to investigate the effect of biomechanical variables on gait according to indoor and outdoor environmental conditions in elderly women at risk of falling. Method: 26 elderly women aged 70 years or older, and consisted of 13 elderly people with a walking speed of less 1.0 m/s and 13 people in the fall risk group as normal groups. Depending on the purpose of the study, physical examination and psychological questionnaire were prepared, and then walking was performed in an indoor/outdoor environment, and the gait pattern, muscle activity, and plantar pressure results were compared and analyzed in the elderly females through a 2 group × 2 environment 2-way repeted ANOVA analysis. Results: The gait variable showed an interaction effect the cadence. The muscle variables showed interaction effects in the rectus femoris and tibialis anterior muscles, and the interaction effects of the plantar pressure variables were confirmed in the forefoot and midfoot of the contact area, and the midfoot of the mean pressure. Conclusion: These results indicate that both groups are exposed to falls risk when gait in an outdoor environment, but the fall risk group has a higher risk of falls in both the gait pattern, muscle activity, and plantar pressure variables. The results of this study are considered to be helpful as basic data and development of exercise programs to prevent falls.

Effects of Adaptation and Sudden Remove of Various Color Information on Plantar Foot Pressure during Gait in Normal Adults (다양한 색상 정보에 대한 적응과 갑작스런 제거가 정상 성인의 보행 중 족저압력에 미치는 영향)

  • Lee, Sang-Yeol;Choi, Su-Hong;Lee, Su-Kyoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.391-396
    • /
    • 2011
  • Purpose : The Purpose of this study is to investigate the values of foot pressure during gait cycle according to adaptation and sudden remove of various color information. Methods : Participants who met the criteria for this study (n=13). RS-Scan was used to measure plantar foot pressur according to Five kinds of color information in this study. Results : The adaptation of various color information is no statistically significant on all area. But sudden remove of various color information is statistically significant on T2-5, M5 and MF area. Conclusion : The results of this study suggest that sudden remove of various color information reduces the ability of balance during gait in normal adults. And these results means that increase risk of falling down according to sudden remove of various color information.

Development of Walking Assistant Controller for Patients with Weakness in Cardiopulmonary System (심폐기능 허약자를 위한 보행보조장치 제어기 개발)

  • Kang, S.J.;Kim, G.S.;P, S.H.;Mun, M.S.;Sei, S.W.;Kim, J.K.;Ryu, J.C.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • Case of patients with weakness in cardiopulmonary system, other ambulatory function is normal, but oxygen supply function is problem. So they need reduce energy consumption for gait by assistance system. In this study, we designed and developed walking assistant device which helps flexion and extension of hip joint for cardiopulmonary patients. There are two motors, each at the left and right side of pelvis, providing torque to the hip joint. The target angle of the flexion and extension in the hip joint is set according to the normal gait. As a result, reduction of energy consumption was 14.8% by gait assistive device.

Plantar Hypoesthesia Alters Gait Kinematics Pattern in Individuals with and without Chronic Ankle Instability (만성 발목 불안정성 환자군과 정상인 군의 발바닥 감각기능 저하에 따른 운동학적 보행 패턴의 변화)

  • Kang, Tae Kyu;Lee, Sae Yong;Lee, Inje;Kim, Byong Hun;Jeong, Hee Seong;Kim, Chang Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.2
    • /
    • pp.79-86
    • /
    • 2021
  • Objective: The purpose of this study was to identify the effect of reduced plantar cutaneous sensation on gait kinematics during walking with and without CAI. Method: A total of 20 subjects involved in this study and ten healthy subjects and 10 CAI subjects participated underwent ice-immersion of the plantar aspect of the feet before walking test in this study. The gait kinematics were measured before and after ice-immersion. Results: We observed a before ice-immersion on plantar cutaneous sensation, CAI subject were found to reduced ankle dorsiflexion, knee external rotation, hip adduction, and internal rotation compared to control subject. After ice-immersion, CAI subjects were found to reduce knee external rotation, hip adduction. However, no significant ankle joint kinematics. Conclusion: While walking, gait pattern differences were perceived between groups with and without plantar cutaneous sensation. The results of the study may explain the abductions in the hip angle movements in CAI patients at initial contact compared to healthy subjects in the control group when plantar cutaneous sensation was reduced. A change in proximal joint kinematics may be a conservative strategy to promote normal gait patterns in CAI patients.

The Effect of Wrist and Trunk Weight Loading using Sandbags on Gait in Chronic Stroke Patients (모래주머니를 이용한 팔목과 몸통의 무게 증가가 만성 뇌졸중 환자들의 보행에 미치는 영향)

  • Park, Sangheon;Lim, Hee Sung;Yoon, Sukhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.50-58
    • /
    • 2021
  • Objective: This study aimed to determine the effect of wrist and trunk weight loading using sandbags in stroke patients in order to provide the quantitative data for enhancement of gait movement. Method: Twelve stroke patients, who have been diagnosed with hemiplegia over a year ago, were participated in this study. All subjects were asked to perform normal walking [N], wrist sandbag walking [W], wrist & trunk sandbag walking [WT], and both wrist sandbag walking [B] and both wrist & trunk sandbag walking [BT], respectively. Eight infrared cameras were used to collect the raw data. Gait parameters, arm swing, shoulder-pelvic kinematics, and lower extremity joint angle were calculated to examine the differences during walking. Results: As a result, there were no significant differences in the gait parameters, shoulder-pelvis, and lower extremities joint angles, but significant differences were found in the range of motion and the anteversion in arm swing. Conclusion: Wrist and trunk weight loading using sandbags affected the movement of the upper extremities only while it did not affect the movement of the lower extremities. It implies that it can reduce the risk of falling caused by a sudden movement change in lower extremities. In addition, the wrist and trunk weight loading using sandbags can induce changes in movement of the upper extremities independently and contribute to functional rehabilitation through resistance training.

Relationships Between the Transfemoral Socket Interface Pressure and Myoelectric Signal of Residual Limb During Gait

  • Hong, J.H.;Lee, J.Y.;Chu, J.U.;Lee, J.Y.;Mun, M.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1070-1073
    • /
    • 2002
  • The biomechanical interaction between the stump and the prosthetic socket is critically important to achieve close-to-normal ambulation. Many investigators suggested that the pressure changes during gait of transfemoral amputees are closely related to the prosthetic alignment, the socket shape, the stump size, and the residual muscle activity. The effects of the prosthetic alignment, the socket shape, and the stump size on the interface pressure were investigated previously. However, there is no report how the residual muscle activities in the transfemoral stump affect the socket interface pressure characteristics during gait. Since designs of socket fur lower limb amputees need to consider the socket interface pressure characteristics, the interface pressure patterns by the residual muscle activities during gait should be investigated. In this study, myoelectric signals (MES) and socket interface pressure in residual limb of transfemoral amputees were measured during the stance and swing phases of gait. For the purpose, specially designed quadrilateral sockets that MES electrodes could be instrumented were fabricated. A total of two transfemoral amputees were participated in the experiments. The measured temporal MES amplitude and interface pressure in knee flexor (biceps femoris) and extensor (rectus femoris) had significant correlations (P < 0.05). Based on the test results, It was suggested that the residual muscle activity of transfemoral amputees stump is an important factor affecting socket pressure changes during walk.

  • PDF

Development and Evaluation of the Auditory Feedback Gait Training System Induced Symmetrical Weight-Bearing in Hemiplegic Patients (편마비 환자의 대칭적 체중부하 유도를 위한 청각적 피드백 보행훈련 시스템 개발 및 평가)

  • Kwon, Y.C.;Lee, H.J.;Tae, K.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.23-30
    • /
    • 2012
  • In this study, we developed a wireless rehabilitation auditory feedback gait training system for symmetrical weight-bearing in patient with CVA. The device consists of an instantaneous shoe equipped with two load-cell sensors. Auditory feedback can be applied according to the weight-bearing. For gait patterns analysis, cadence, walking velocity, stance/swing phase ratio and gait cycle were examined. The clinical test with six healthy volunteers and two hemiplegic patients was performed applying the auditory feedback system. Both normal subjects and hemiplegic patients were increased strength on weight-bearing in affected limb, walking velocity, and cadence after biofeedback device. Also, the stance time with weight-bearing was increased while the swing time was decreased in gait phase. It can be expected that by using the feedback system, the patient with lower limb disorder will be able to reach a better quality of weight-bearing during gait.

  • PDF