• Title/Summary/Keyword: Normal eyes

Search Result 208, Processing Time 0.023 seconds

Test-retest Reliability of Balance Tests in Older Adults (노인들에 대한 균형검사의 검사-재검사 신뢰도)

  • Kang, Soon-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.16 no.4
    • /
    • pp.49-57
    • /
    • 2009
  • Background: The purpose of this study was to assess the test-retest reliability of balance measurements in older adults using balance measurement system(Good Balance). Methods: The subjects consisted of 49 female and 20 male in community-dwelling older adults. This study used a repeated-measure design. Each subject completed all the different tests once and they were then repeated with 2 minutes in between. Repeated two-ways analysis of variance(ANOVA), representing two test times and both sexes, was calculated for each of the two dependent variables. Intraclass correlation coefficients(ICCs) were used to assess the test-retest reliability. Results: 1) There was not significant difference between test and retest for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There was not significant difference between males and females for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There were not the interaction effects between genders and test time under three conditions. 2) The reproducibility between test and retest was excellent for anterioposterior sway speed(ICC=.77) under condition of normal standing with eyes open, and for mediolateral sway speed(ICC=.76) and anterioposterior sway speed(ICC=.84) under condition of semitandem standing with eyes open. The reproducibility between test and retest was fair to good for mediolateral sway speed(ICC=.64) under condition of normal standing with eyes open, for mediolateral sway speed(ICC=.63) and anterioposterior sway speed(ICC=.75) under condition of normal standing with eyes closed. Conclusion: Balance tests in older adults using balance measurement system(Good Balance) demonstrated acceptable levels of reliability.

  • PDF

Analysis of Visual Acuity and Retinal State in the Eyes with Central Serous Chorioretinopathy (중심장액성맥락망막병증 눈의 시력 및 망막 상태 분석)

  • Choi, Jong Kil;Lee, Kyung Min;Kim, Se-il;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.137-146
    • /
    • 2016
  • Purpose: The relationship between retinal conditions such as macular thickness and retinal volume of the eyes with central serous chorioretinopathy(CSC) and visual acuity was investigated. Methods: A total of 136 eyes from 78 subjects was divided into 5 groups: CSC eyes under treatment and its asymptomatic contralateral eyes, fully cured CSC eyes after the diagnosis and its contralateral, and normal eyes. Their uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), retinal thickness and retinal volume were further examined. Results: All of UCVA, BCVA, retinal thickness and retinal volume of CSC eyes under treatment were significantly different from those of asymptomatic contralateral eyes, fully cured CSC eyes and normal eyes. BCVA of the asymptomatic contralateral eyes was not significantly different from it of normal eyes, however, its retinal thickness and volume were significantly different from those of normal eyes. Increased degree of retinal volume along with the increase of retinal volume was greater in CSC eyes and its asymptomatic contralateral eyes, fully cured CSC eyes and its contralateral eyes than normal eyes. Conclusions: From the present study, it was revealed that the retinal thickness and volume of asymptomatic contralateral eyes of CSC increase as well as CSC eyes, and the change of BCVA due to CSC occurs only when the retinal thickness and volume increase in some extent.

A Study of Sitting Balance Control between Normal group and with Low Back Pain group According to Eyes Condition Change (정상군과 요통환자군의 시각변화에 따른 자세 균형 조절에 관한 연구)

  • Kim, Beung-Sun;Lee, Suk-Min
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.109-121
    • /
    • 2003
  • The purpose of this study was to test the difference of sitting balance control between a normal group and a group of patients with low back pain when their eyes were opened or closed. The 30 subjects of the control group had been chosen from healthy individuals who fit into the pre-designed criteria, and the 30 subjects of the experimental group were composed of the patients with LBP who had their treatment from S hospital from september 1, 2002, to October 30, 2002, and the subjects were measured by static balance test by using a balance performance monitor(BPM). Static balance test was done twice for each subject with his or her eyes opened and closed. Collected data were statistically analyzed by SPSS/PC using unpaired T-Test, Pained T-Test and multiple regression. The results were as follows: 1. In static balance test, normal group did not show statistical significance in sway angle(Anterior, Posterior, left and Right), sway path, sway area and maximal sway velocity, but showed statistical significance in mean balance with eyes opened and eyes dosed(P<.05) 2. In static balance test, LBP group did not show statistical significance in sway angle(Anterior, Posterior, left and Right), mean balance, sway path, sway area and maximal sway velocity with eyes opened and eyes dosed 3. With eyes opened, the comparison between the normal group and the LBP group showed statistical significance in sway angle(Anterior, Posterior, left and Right), mean valance, sway path, sway area and maximal sway velocity(p<.05). With eyes closed, normal group and LBP group did not show statistical significance in sway angle(Anterior and Right), sway area, but showed statistical significance in sway angle(Posterior and Left), mean balance, sway path, sway area and maximal sway velocity(p<.05) In conclusion, there was a significant difference in static sitting balance between normal group and LBP patients group. For future studies, I strongly suggest that researches be done on the treatment with LBP by predicting changes of postures and manipulating them.

  • PDF

The Difference of Tear Break-Up Time by the Fitting States of Soft Contact Lens in Normal and Dry Eyes (정상안과 건성안에서 소프트렌즈 피팅 상태에 따른 비침입성 눈물막 파괴 시간의 차이)

  • Jung, Da I;Lee, Heum Sook;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.339-346
    • /
    • 2010
  • Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.

Quantitative Differences in mRNA Expression of Toll-like Receptor (TLR)-2, -4, and -9 in Normal Equine Eyes and Eyes with Equine Recurrent Uveitis (말의 정상안과 재발성 포도막염이 있는 안구에서의 Toll-like Receptor-2, -4, -9 발현 비교)

  • Yi, Na-Young;Salmon, Jacklyn;Gilger, Brian
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.520-523
    • /
    • 2009
  • The purporse of this study was to evaluate the quantitative differences in mRNA expression of TLR-2, -4, and -9 in normal equine eyes and eyes with equine recurrent uveitis (ERU). Normal equine eyes (n = 6) and eyes with naturally-occurring ERU (n = 6) were collected. Real time PCR assay was performed to compare mRNA expression of TLR-2, -4, and -9 between normal and ERU eyes. A significant up-regulation of TLR-2 and -9 mRNA in the ciliary body and TLR-2 mRNA in the iris was found in eyes with ERU compared to the mRNA levels in these same tissues of normal equine eyes. There were no remarkable differences observed in TLR-4 mRNA expression between normal eyes and eyes with ERU. The current data suggest the potential involvement of TLR-2 and -9 in the pathogenesis of ERU. However, further study is required to determine the role of TLRs in ERU.

The Comparison of Lens Movement by the Fitting States of Soft Contact Lenses in Normal and Dry Eyes (정상안과 건성안에서 피팅상태에 따른 각막에서의 소프트렌즈 움직임 비교)

  • Jung, Da I;Lim, Shin Kyu;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2011
  • Purpose: The study was performed to compare the differences in lens rotation, lens movement by blinking and lens centration with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified into the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment fitting or steep fitting. Lens rotation, lens movement by blinking and lens centration were separately measured immediately after lens wearing and after stabilization of tear film and compared by fitting states of soft contact lenses. Results: With steep fitting of soft contact lens in dry eyes, averaged lens rotation immediately after lens wearing was not significantly different from that of the normal eye group with alignment fitting however, lens rotation after stabilization in dry eyes was significantly larger than that in normal eyes. Any significant difference in lens movement by blinking was not shown in normal eyes. However, lens movement by blinking in dry eyes was increased with steep fitting. The range of lens centration on cornea in normal eyes with alignment fitting was more vertically distributed. On the other hand, the range of lens centration on cornea in dry eyes with alignment fitting was more horizontally distributed. Lens centration was shown to be changed by stabilization of tear film. That is, lens centrations were somewhat vertically widespread immediately after lens wearing and restrictively distributed in horizontal direction, respectively, with steep fitting in dry eyes. Conclusions: These results suggested that lens movements and centration in dry eyes were different from those of normal eyes. Especially, those differences between normal and dry eyes were much bigger with steep fitting of soft contact lenses. Thus, those differences should be considered for the comfortable and safe fitting of soft contact lens in dry eyes.

Diurnal Change of Intraocular Pressures and Comparison of $Tono-pen^{XL}$ and Schi$\emptyset$tz Tonometer in Normal Dogs (정상견 안압의 일변동과 안압계간 측정치의 비교)

  • 김완희;권오경
    • Journal of Veterinary Clinics
    • /
    • v.19 no.4
    • /
    • pp.415-417
    • /
    • 2002
  • To investigate the diurnal change of intraocular pressures(IOP) and compare of $Tono-pen^{XL}$ and Schi$\emptyset$tz tonometer, we measured the IOP in clinically normal eyes of dogs. To estimate the diurnal change of IOP, the measurements of IOP were taken with $Tono-pen^{XL}$ in 44 normal canine eyes. Two physicians measured the IOP through the central cornea and limbal cornea. To compare of two tonometers, a physician measured the IOP with both $Tono-pen^{XL}$ and Schi$\emptyset$tz (7.5 g) tonometer in 23 clinically normal eyes of dogs. Mean of lOP was 26.51 $\pm$ 6.91 mmHg and IOP was highest as 30.65 mmHg at a.m. 10, but not significantly different within physicians and corneal regions (p > 0.05). Correlation coefficient within two tonometers was too low.

The Changes of Balance Ability after Therapeutic Intervention for Muscle Strengthening of Cervical (경추부의 근력강화 운동이 건강한 성인의 균형 능력에 미치는 영향)

  • Park, Jonghang;Kim, Yoonhwan;Choi, Wonjye;Seo, Taehwa;Song, Hyunseung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.2
    • /
    • pp.31-40
    • /
    • 2014
  • Purpose : To evaluate the effect of cervical strengthening exercise on balance ability in healthy adults. Method : The subjects consisted of forty healthy people. The subjects were divided into two group. The control group(n=14) received no exercise and/or stimulation. The cervical strengthening exercise group(n=14) performed therapeutic intervention using cervical exercise for strengthening of cervical spine muscle. The exercise group were accomplished during 6 weeks(2~3set, 5times/week). All tests were completed before and after experiment. The static balance ability was measured by normal standing when subjects open and close their eyes on GOOD BALANCE SYSTEM, respectively. For each case, the experimental data were obtained in 3 items: mean X speed, mean Y speed and velocity moment. Result : The results of this study were as follows; 1. In the exercise group, the statistically significant difference were shown on X speed and Y speed in the case of normal standing when subjects open and close their eyes and X speed, Y speed and velocity moment in the case of normal standing when subjects close their eyes(p<0.05). 2. In control group, the statistically significant difference were not shown on all posture(p>0.05). 3. There were a statistically significant difference in the X speed and Y speed in the case of normal standing when subjects open their eyes between control group and the exercise group(p<0.05). There were a statistically significant difference in the X speed, Y speed and velocity moment in the case of normal standing when subjects close their eyes between control group and exercise group(p<0.05). Conclusion : The above results revealed that therapeutic intervention for muscle strengthening of cervical there were positive changes to balance ability.

Effect of Calf Muscle Fatigue on Postural Sway According to Foot Posture (발 자세에 따른 종아리 근육의 피로유발이 자세 흔들림에 미치는 영향)

  • Lee, Myoung-Hee;Chang, Jong-Sung
    • PNF and Movement
    • /
    • v.17 no.3
    • /
    • pp.481-486
    • /
    • 2019
  • Purpose: This study examined the effect of calf muscle fatigue on postural sway according to foot posture (a pes cavus, a normal foot, and a pes planus). Methods: The subjects of this study were 12, 11, and 9 students of U University with a pes cavus, a normal foot, and a pes planus, respectively, according to a Navicular Drop Test. Postural sway was measured with a balance instrument (BioRescue, RM Ingenierie, France) while the subjects stood static on two legs as well as during one-leg standing using the dominant leg in two conditions (with the eyes open and with the eyes closed for 30 seconds). Muscle fatigue was then induced in the calf muscle of the dominant leg, and both muscle fatigue and postural sway were measured using an EMG. To compare the degree of postural sway between the three groups after muscle fatigue was induced, the change values were calculated. The results were analyzed using a Kruskal-Wallis test, and a post-hoc test was conducted using the Bonferroni correction. Results: Significant inter-group differences were detected for postural sway during two-leg standing with the eyes closed and during one-leg standing with the eyes open and with the eyes closed (p<0.05). The post-hoc test showed significant differences between the pes cavus and normal foot groups and between the pes planus and normal foot groups for all three variables (p<0.05). However, no significant difference was detected between the pes cavus and pes planus groups (p>0.05). Conclusion: The results of this study show that the pes cavus and pes planus cause more fatigue and postural sway than a normal foot. Therefore, attention should be paid to changes in balance caused by muscle fatigue.

Characteristics of Static Balance in Patients With Adolescent Idiopathic Scoliosis

  • Shin, Seung-Sub;Woo, Young-Keun
    • Physical Therapy Korea
    • /
    • v.13 no.4
    • /
    • pp.47-55
    • /
    • 2006
  • The purpose of this study was to compare the static balance of standing position between adolescent idiopathic scoliosis (AIS) and a normal group that were aged-matched. There were forty subjects included in this study. Twenty-seven healthy subjects (age, $13.9{\pm}1.2$ yrs; height, $161.9{\pm}7.5$ cm; weight, $52.2{\pm}7.7$ kg) and thirteen AIS subjects (age, $14.2{\pm}2.2$ yrs; height, $161.5{\pm}8.7$ cm; weight, $48.1{\pm}8.1$ kg) were participated in the study. The thirteen subjects in the AIS group had a major Cobb angle between $20.1^{\circ}$ and $49^{\circ}$. Each group was tested with the Balance Performance Monitor (BPM). The parameters for static balance were sway area, sway path, max velocity, mean balance, anterior-posterior angle, and left-right angle of each group with their eyes opened and again with their eyes closed. Both sides of the forward reach test and the lateral reach test were also performed on each group. Results from the BPM tested showed significantly increases in all parameters of static balance with those patients with AIS under the conditions where eyes were opened and closed. In the right and left forward reach test, there was no significant difference between normal and AIS groups. However, in the lateral reach test with right and left direction, there were significant differences between normal and AIS groups. For the normal subjects, there were significant differences in the parameters with sway path and anterior-posterior sway angle between the eyes opened and closed. However, there were no significant differences in the all parameters between eyes opened and closed for the AIS subjects. These results suggest that, balance programs could be used in the rehabilitation setting for intervention of AIS and evaluation of AIS. Further study is needed to measure many patients with AIS and other functional balance scales for clinical application.

  • PDF