• Title/Summary/Keyword: Normal Stiffness

Search Result 404, Processing Time 0.027 seconds

Three-dimensional finite element analysis of the interference of adjacent moving trains resting on a ballasted railway track system

  • Marwah Abbas Hadi;Saif Alzabeebee;Suraparb Keawsawasvong
    • Geomechanics and Engineering
    • /
    • v.32 no.5
    • /
    • pp.483-494
    • /
    • 2023
  • High-speed trains became common nowadays due to the need for fast and safe mean to transport goods and people. However, the use of high-speed trains necessitates the examination of the critical speed, which is the train speed at which the maximum settlement of the railway track occurs. The critical speed and railway track settlement have been investigated considering only one train in previous studies. However, it is normal to have two adjacent trains moving at the same time. This paper aims to understand how the interference of two moving trains affects the settlement and critical speed of ballasted railway track. Calibrated three-dimensional finite element models of railway track subjected to one moving train and two moving trains have been developed to address the aim of the study. It is found that the interference dramatically increases the railway track settlement with a percentage increase ranges between 5 and 100%. It is also found that the percentage increase of the railway track settlement depends on the train speed and the distance between the moving trains. In addition, it is found that the thickness of the ballast layer and the stiffness of the subgrade have minor influence on the percentage increase of the settlement. Importantly, the results of this paper illustrate the importance of the interference of the moving trains on the dynamic response of the railway track. Thus, there is a need to consider the dynamic interaction between the adjacent moving trains in the design of railway track foundation.

Diagnosis and treatment of the odontoid process fracture of the axis in a dog (강아지 고리뼈의 치아돌기 골절 진단과 치료)

  • Hyoung Joon Park;ShinHo Lee;Chung Hui Kim;ChungKil Won;Jae-Hyeon Cho
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.1
    • /
    • pp.87-92
    • /
    • 2023
  • A 7-year-old dog weighing 3.9 kg visited the hospital with symptoms of inability to stand and quadriparesis. There were seizure symptoms 2 months before admission to the hospital, and the symptoms of stiffness and rigidity appeared. Radiographs showed normal vertebrae in cervical vertebral column. Magnetic resonance imaging (MRI) and computed tomography (CT) were performed immediately to diagnose vertebral lameness. As a result of the CT, it was possible to observe the fracture of the odontoid process of the axis, and the exact location of the damage was identified. The odontoid process was fractured and separated from the body of the 2nd cervical vertebra (axis), and fragment of the process was observed inside the vertebral arch of the first cervical vertebra (atlas), and the body of the axis was lifted to the dorsal side. The MRI examination reflected the CT findings and confirmed severe spinal cord compression due to the fracture of the odontoid process. The patient was applied by neck brace and medical management including Mycophenolate mofetil administration was performed. The patient was able to move legs and tail after 2 weeks, and was able to voluntarily defecate, urinate and stand up after 4 weeks of administration.

Diagnosis and Management of Suspected Case of Early Rheumatoid Arthritis in the Temporomandibular Joint: A Case Report

  • Tae-Seok Kim;Yeon-Hee Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.1
    • /
    • pp.31-36
    • /
    • 2023
  • This report presents the case of a 14-year-old male with rheumatoid arthritis (RA) in both temporomandibular joints (TMJs), in whom a bone scan and laboratory tests were used to confirm the diagnosis. The patient visited the Department of Orofacial Pain and Oral Medicine at the affiliation hospital with a complaint of a 1-year history of bilateral TMJ pain and sound. Clinical examination revealed bilateral TMJ and masseter muscle pain during mouth opening and palpation. Radiological examination revealed no significant morphological changes in either TMJ. The patient was prescribed medications at the first visit to address the pain, inflammation, and stiffness. A bone scan and laboratory tests were planned/scheduled for differential diagnosis between simple arthralgia and osteoarthritis. The bone scan revealed increased radiotracer uptake in both TMJs. The laboratory tests revealed a RA factor of 82.4 IU/mL, which is more than four times the normal range. The final diagnoses were bilateral TMJ early rheumatoid arthritis (ERA) and juvenile idiopathic arthritis. We created a stabilization splint and referred the patient to the Department of Rheumatology for further evaluation of the ERA. After fitting of the stabilization splint and giving instructions regarding its use, the patient has been receiving monthly follow-up checks for symptoms and undergoes follow-up blood tests every 3 months. About 14 months after the initial visit, the pain had significantly decreased from a Visual Analog Scale score of 5 to 1, and the RA factor decreased to 66.6 IU/mL. A regular follow-up check will continue until the end of growth.

Generalization and implementation of hardening soil constitutive model in ABAQUS code

  • Bo Songa;Jun-Yan Liu;Yan Liu;Ping Hu
    • Geomechanics and Engineering
    • /
    • v.36 no.4
    • /
    • pp.355-366
    • /
    • 2024
  • The original elastoplastic Hardening Soil model is formulated actually partly under hexagonal pyramidal Mohr-Coulomb failure criterion, and can be only used in specific stress paths. It must be completely generalized under Mohr-Coulomb criterion before its usage in engineering practice. A set of generalized constitutive equations under this criterion, including shear and volumetric yield surfaces and hardening laws, is proposed for Hardening Soil model in principal stress space. On the other hand, a Mohr-Coulumb type yield surface in principal stress space comprises six corners and an apex that make singularity for the normal integration approach of constitutive equations. With respect to the isotropic nature of the material, a technique for processing these singularities by means of Koiter's rule, along with a transforming approach between both stress spaces for both stress tensor and consistent stiffness matrix based on spectral decomposition method, is introduced to provide such an approach for developing generalized Hardening Soil model in finite element analysis code ABAQUS. The implemented model is verified in comparison with the results after the original simulations of oedometer and triaxial tests by means of this model, for volumetric and shear hardenings respectively. Results from the simulation of oedometer test show similar shape of primary loading curve to the original one, while maximum vertical strain is a little overestimated for about 0.5% probably due to the selection of relationships for cap parameters. In simulation of triaxial test, the stress-strain and dilation curves are both in very good agreement with the original curves as well as test data.

The behavior of concrete filled steel tubular columns infilled with high-strength geopolymer recycled aggregate concrete

  • Rajai Z. Al-Rousan;Haneen M. Sawalha
    • Steel and Composite Structures
    • /
    • v.51 no.6
    • /
    • pp.661-678
    • /
    • 2024
  • The utilization of geopolymer recycled aggregate concrete (GRAC) as the infilled core of the concrete-filled steel tubular (CFST) columns provides superior economic and environmental benefits. However, limited research exists within the field of geopolymer recycled aggregate concrete considered a green and sustainable material, in addition to the limitation of the design guidelines to predict the behavior of such an innovative new material combination. Moreover, the behavior of high-strength concrete is different from the normal-strength one, especially when there is another material of high-strength properties, such as the steel tube. This paper aims to investigate the behavior of the axially loaded square high-strength GRACFST columns through the nonlinear finite element analysis (NLFEA). A total of thirty-two specimens were simulated using ABAQUS/Standard software with three main variables: recycled aggregate replacement ratio (0, 30, and 50) %, width-to-thickness ratios (52.0, 32.0, 23.4, and 18.7), and length-to-width ratio (3, 5, 9, and 12). During the analysis, the response in terms of the axial load versus the longitudinal strain was recorded and plotted. In addition, various mechanical properties were calculated and analyzed. In view of the results, it has been demonstrated that the mechanical properties of high-strength GRACFST columns such as ultimate load-bearing capacity, compressive stiffness, energy absorption capacity, and ductility increase with the increase of the steel tube thickness owing to the improvement of the confinement effect of the steel tube. In contrast, the incorporation of the recycled aggregate adversely affected the mentioned properties except the ductility, while the increase of the recycled aggregate replacement ratio improved the column's ductility. Moreover, it has been found that the increase in the length-to-width ratio significantly reduced both the failure strain and the energy absorption capacity. Finally, the obtained NLFEA results of the ultimate load-bearing capacity were compared with the corresponding predicted capacities by numerous codes. It has been concluded that AISC, ACI, and EC give conservative predictions for the ultimate load-bearing capacity since the confinement effect was not considered by these codes.

Association between Pulse Pressure and Impaired Pulmonary Function in Non-Smoking Adults (비흡연 성인에서 맥압과 폐기능 장애의 상관성)

  • Yoon, Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.2
    • /
    • pp.119-127
    • /
    • 2020
  • According to previous studies, an impaired pulmonary function is associated with arterial stiffness (AS). The pulse pressure (PP) is an important predictor of AS, but the association of an impaired pulmonary function with the PP is unclear. Therefore, this study assessed the associations between the PP and the predicted forced vital capacity (predicted FVC) and predicted forced expiratory volume in one second (predicted FEV1) in Korean non-smoking adults. The data obtained from 6,857 adults during the 2013~2015 Korean National Health and Nutrition Examination Survey were analyzed. After adjusting for the related variables, the ORs of restrictive pulmonary disease (RPD, the predicted FVC<80.0% with FEV1/FVC≥70.0%) using the normal PP group (PP≤60 mmHg) as a reference group was significant for the high PP group (PP>60 mmHg; 1.337 [95% confidence interval (CI), 1.049~1.703]). In addition, the ORs of obstructive pulmonary disease (OPD, FEV1/FVC<70.0%) using the normal PP group as a reference group were significant for the high PP group (1.339 [95% CI, 1.093~1.642]). In conclusion, a high PP is positively associated with both RPD and OPD in Korean non-smoking adults.

Pulse wave velocity and ankle brachial index in normal adolescents (정상 청소년에서 맥파 속도와 발목 상완 동맥압 지수에 대한 연구)

  • Kim, Ji Hye;Gil, Tae Young;Lee, Hee Woo;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.6
    • /
    • pp.549-555
    • /
    • 2007
  • Purpose : Pulse wave velocity (PWV) and ankle brachial index (ABI) are simple, non-invasive methods to assess arterial stiffness. These parameters are also known to be closely related to cardiovascular risk factors and diseases. The purposes of this study were to measure blood pressure, PWV, ABI in healthy Korean adolescents, set up their normal values and assess their correlations. Methods : Three hundred ninety two healthy adolescents (213 boys and 179 girls) underwent measurement of brachial ankle pulse wave velocity (baPWV), ABI, body mass index(BMI) and blood pressure from four extremities. Linear regression analysis was performed to reveal the correlations between PWV, ABI and independent variables. Results : Blood pressure and PWV were significantly higher in all extremities in males compared to females. Blood pressure of both brachial and ankle showed positive correlation with body weight, height, and BMI, whereas ABI showed no correlation with any of these indices. Conclusion : Blood pressure increases as body weight, height and BMI increases. PWV shows positive correlation with blood pressure. It will be helpful to predict the risks of cardiovascular diseases in adolescents.

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.

A Biomechanical Study on the Various Factors of Vertebroplasty Using Image Analysis and Finite Element Analysis (의료영상 분석과 유한요소법을 통한 추체 성형술의 다양한 인자들에 대한 생체 역학적 효과 분석)

  • 전봉재;권순영;이창섭;탁계래;이권용;이성재
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.171-182
    • /
    • 2004
  • This study investigates the biomechanical efficacies of vertebroplasty which is used to treat vertebral body fracture with bone cement augmentation for osteoporotic patients using image and finite element analysis. Simulated models were divided into two groups: (a) a vertebral body, (b) a functional spinal unit(FSU). For a vertebral body model, the maximum axial displacement was investigated under axial compression to evaluate the effect of structural integrity. The stiffness of each FE model simulated was normalized by the stiffness of intact model. In the case of FSU model, 3 types of compression fractures were formulated to assess the influence on spinal curvature changes. The FSU models were loaded under compressive pressure to calculate the change of spinal curvature. The results according to the various factors suggest that vertebroplasty has the biomechanical efficacy of the increment of structural reinforcement in a patient who has relatively high level of BMD and a patient with the amount of 15%, PMMA injection of the cancellous bone volume. The spinal curvatures after compression fracture simulation vary from 9$^{\circ}$ to 17$^{\circ}$ of kyphosis compared to that the spinal curvature of normal model was -2.8$^{\circ}$ of lordosis. These spinal curvature changes cause the severe spinal deformity under the same loading. As the degree of compressive fracture increases the spinal deformity also increases. The results indicate that vertebroplasty has the increasing effect of the structural integrity regardless of the amount of PMMA or BMD and the restoration of decreased vertebral body height may be an important factor when the compressive fracture caused the significant height loss of vertebral body.

Pulse wave velocity and ankle brachial index in adolescents with essential hypertension (본태성 고혈압 청소년에서 pulse wave velocity와 ankle brachial index에 대한 연구)

  • Joo, Sun Young;Cho, Ki Young;Cho, Su Jin;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.7
    • /
    • pp.769-776
    • /
    • 2006
  • Purpose : Pulse wave velocity(PWV) and ankle brachial index(ABI) are not only noninvasive methods used to assess arterial stiffness in adults, but also useful, simple ways to estimate the severity of hypertension, end stage renal disease and atherosclerosis in adults. But there are few studies on PWV and ABI in adolescents and children. In this study, hypertensive adolescents were compared to normal individuals to find out the usefulness of PWV as the index of progress in the disease. Methods : 413 teenagers were divided into three groups. The first group consisted of adolescents that only had hypertension(Group 1 : 23 teenagers). The second group consisted of the adolescents who had hypertension with obesity(Group 2 : 17 teenagers), and the last group was the normal subjects(Group 3 : 328 teenagers). Weight, height and body mass index were measured. Simultaneous measurements of systolic, diastolic and average blood pressure were obtained from the four extremities. PWV, ABI, ejection time and preejection period were also measured. Results : Right brachial-ankle PWV was significantly higher in both group 1 and group 2 compared with group 3, and significantly higher in group 2 compared with group 1. Likewise, left brachial-ankle PWV also showed significantly higher values in both group 1 and group 2 compared with group 3, and also higher values in group 2 compared with group 1. Positive correlations were found between the systolic, diastolic, average blood pressure and PWV. There were also positive correlations between the blood pressure and weight, body mass index. Conclusion : Higher PWV was demonstrated in adolescents with essential hypertension compared to normal subjects. Follow-up study is needed to evaluate the progress.