• Title/Summary/Keyword: Nonpoint pollutant

Search Result 219, Processing Time 0.028 seconds

Application of Water Quality Management System of Freshwater Lake

  • Kim, Sun-Joo;Kim, Phil-Shik;Lee, Joo-Young
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.38-48
    • /
    • 2003
  • Lake water quality assessment information is useful to anyone involved in lake management, from lake owners to lake associations. It provides lake water quality criteria, which can improve the ways how to manage out lake resources and how to measure current conditions. It also provides a knowledge base so that the lakes can be protected and restored. Here, the Freshwater Lake Water Quality Management System(FLAQUM) was developed. The results of FLAQUM application by scenario proved that pollutant load at rainfall by the nonpoint sources was much more than normal times at rainfall. From the result of Scenario I (pollutant source increase case), the concentrations of Boryeong freshwater lake were BOD 9.43mg/L, T-N 4.53 mg/L and T-P 0.21 mg/L, respectively, and those values exceed the standard of agricultural water. And in case of Scenario I and II(the present case) excluding Scenario III (pollutant source decrease case), all of T-N and T-P are either mesotrophication or eutrophication, on the other hand when 60% of pollution source is removed, the concentrations of Scenario III were BOD 3.21 mg/L, T-N 0.95 mg/L, T-P 0.11 mg/L, respectively, and which satisfies the standard of agricultural water quality.

Estimation of Livestock Pollutant Sources Reduction Effect on Water Quality in Hapcheon Dam Watershed Using HSPF Model (HSPF 모형을 이용한 축산계 비점오염 저감에 따른 합천댐 유역 수질 영향 분석)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.98-108
    • /
    • 2020
  • The purpose of this study was to evaluate water quality in Hapcheon dam via using the Hydrological Simulation Program-Fortran (HSPF) model and applied livestock reduction scenarios. Hapcheon dam watershed input data for the HSPF model were established using the stream, land use, digital elevation map and meteorological data and others. The HSPF model was calibrated and validated using the observed water quality data from 2000 to 2016. For water quality simulation, we calculated the generated and discharge loads of the population, livestock, industry and land use following the guideline provided by the Ministry of Environment. The pollutant data were obtained from National Institute of Environmental Research (NIER). The monthly discharge load were estimated by applying the delivery rate. The calibration and validation results showed that the annual mean BOD had a difference of 0.22 mg/L and an error of ±13 %, T-N had a difference of 0.66 mg/L and an error of ±16 % and T-P had a difference of 0.027 mg/L and an error of ±13 %. In order to evaluate the nonpoint pollutants management effects, we applied livestock reduction scenarios because livestock consists of the largest portion of pollutants. As a result of the 20 % of livestock reduction, BOD, T-N and T-P decreased by 3 %, 1 % and 3 %, respectively. When 40 % of livestock reduction was applied, BOD, T-N and T-P decreased by 5 %, 3 % and 4 %, respectively. Based on the results of this study, effective pollutant management methods can be applied to improve the water quality and achieve the target water quality of Hapcheon dam watershed.

Analysis of Nonpoint Sources Runoff Characteristic for the Vineyard Areas (포도밭에 대한 비점오염원 유출특성 해석)

  • Yoon, Young-Sam;Lee, Sang-Hyeup;Yu, Jay-Jung;Lee, Jae-Kwan
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.361-372
    • /
    • 2011
  • This study analyzed the characteristics of stormwater runoff by rainfall type in orchard areas for two years. Effluents were monitored to calculate the EMCs and runoff loads of each pollutant. The runoff characteristics for nonpoint sources from vineyards were also inspected based on independent variables that affect runoff such as rainfall and rainfall intensity. The average runoff loads of each pollutant from vineyard_A and vineyard_B were found as follows: BOD 39.13 mg/$m^2$, COD 112.13 mg/$m^2$, TOC 54.98 mg/$m^2$, SS 1,681.8 mg/$m^2$, TN 18.29 mg/$m^2$, and TP 4.06 mg/$m^2$, which indicates that the COD's runoff load was especially high. The average EMCs from vineyard_A and vineyard_B, which represents the quality of rainfall effluent, were also analyzed: BOD 3.5 mg/L, COD 11.5 mg/L, TOC 5.2 mg/L, SS 211.7 mg/L, TN 1.774 mg/L, and TP 0.324 mg/L. This suggested that the COD, as an indicator of organic pollutants, is high in terms of EMCs as well. As rainfall increased, the EMCs of BOD, COD, TOC and SS kept turning upward. At a point, however, the high rainfall brought about dilution effects and began to push down the EMCs. Higher rainfall intensities led to the increase in the EMCs that displays the convergence of rainfall. Low rainfall intensities also raised pollutant concentrations, although the concentrations themselves were slightly different among pollutants.

Characteristics of NPS Pollutants and Treatment of Stormwater Runoff in Paved Area during a Storm (강우시 포장지역의 비점오염물질 유출 및 저감특성)

  • Son, Hyun-Geun;Lee, So-Young;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.11 no.2
    • /
    • pp.55-66
    • /
    • 2009
  • The increase of pollutant loadings from nonpoint sources affect the water quality of the major rivers in Korea. Consequently, the need for managing the nonpoint source (NPS) pollution becomes the main concern of the Korean Ministry of Environment (MOE). Recently, the policy was changed from pollutant concentration-restricting approach to the total maximum daily load (TMDL) approach to improve the water quality and protect the aquatic ecosystem. Part of the program is the construction of Best Management Practice (BMP) pilot facilities basically to control NPS. Most of the BMPs adopted were foreign technologies which could not be properly employed in the country due to some limitations such as climate, watershed characteristics, etc. In other words, to be able to apply the BMPs, research on its applicability is necessary. In this study, a three-year monitoring has been conducted to assess the treatment performance of the BMP installed in highway toll plaza and parking lot. The data gathered aid in the characterization of NPS pollutants in runoff and estimation of the pollutant removal efficiency of the BMP. The results will be used for the future implementation of BMP in different land uses as well as for the determination of optimum operation and maintenance.

  • PDF

A Study on the Estimation Methods of Nonpoint Pollutant Unit Load - Focus on Nonpoint Pollutant Unit Load in Paddy Field - (비점오염 발생 원단위 산정방법에 대한 고찰 - 논 비점오염 원단위를 중심으로 -)

  • Choi, DongHo;Choi, Soon-Kun;Kim, Min-Kyeong;Hur, Seung-Oh;Hong, Sung Chang;Yeob, So-Jin;Yoon, KwangSik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.15-22
    • /
    • 2019
  • In order to preserve water environment, Total Maximum Daily Load(TMDL) is used to manage the total amount of pollutant from various sources, and the annual average load of source is calculated by the unit load method. Determination of the unit load requires reliable data accumulation and analysis based on a reasonable estimation method. In this study, we propose a revised unit load estimation method by analyzing the unit load calculation procedure of National Institute of Environment Research(NIER) method. Both methods were tested using observed runoff ratio and water quality data of rice paddy fields. The estimated values with the respective NIER and revised NIER methods were highly correlated each other. However, the Event Mean Concentration(EMC) and the runoff ratio considered in the NIER method appeared to be influenced by rainfall classes, and the difference in unit load increases as the runoff and EMC increase. The error can be further increased when the EMC and runoff ratio are changed according to changes in rainfall patterns by climate change and change of agricultural activities. Therefore, it is recommended to calculate unit load by applying the revised NIER method reflecting the non point pollution runoff characteristics for different rainfall classes.

Pollution accident analysis using a hybrid hydrologic-hydraulic model(K-River & K-DRUM) (1차원수리모형-분포형 연계모형을 이용한 수질오염사고 분석)

  • Yonghyeon Lee;Hyunuk An;Ahn Jungmina;Youngteck Hur
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.472-472
    • /
    • 2023
  • In this study, the transport of pollutants was analyzed using the K-River and K-DRUM coupling model for water pollution accidents that occurred in the Nakdong River water system. In Korea, the necessity of a distribution model that accommodates the water circulation process and the importance of nonpoint pollution sources were emphasized in water quality management after the introduction of the total amount of water pollution. Therefore, in order to reflect the runoff characteristics of nonpoint sources, the K-DRUM distribution model, which can analyze pollution in the basin, was used. And the reproducibility of the model was improved by applying the operating rules of dams operating in the Nakdong River system. In addition, in order to analyze the movement of pollutants in the river, only the advection part of the advection-dispersion equation was applied to the 1D hydraulic model K-River to perform pollutant tracking. As a result of water pollution analysis, the peak concentration of the pollutant was underestimated, but the arrival time and the trend of the overall pollutant concentration were well reproduced.

  • PDF

Evaluation of Runoff and Pollutant Loads using L-THIA 2012 Runoff and Pollutant Auto-calibration Module and Ranking of Pollutant Loads Potential (L-THIA 2012 유출 및 수질 자동 보정 모듈을 이용한 유출/비점부하량 산정 및 비점오염 부하량 포텐셜 등급화)

  • Jang, Chunhwa;Kum, Donghyuk;Ha, Junsoo;Kim, Kyoung-Soon;Kang, Dong Han;Kim, Keuk-Tai;Shin, Dong Suk;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.184-195
    • /
    • 2013
  • Urbanization from agricultural/forest areas has been causing increased runoff and pollutant loads from it. Thus, numerous models have been developed to estimate NPS loading from urban area and Long-Term Hydrologic Impact Analysis (L-THIA) model has been used to evaluate effects of landuse changes on runoff and pollutant loads. However, the L-THIA model could not consider rainfall intensity in runoff evaluation. Therefore, the L-THIA model, capable of simulating runoff using 10-minute rainfall data, was applied to the study areas for evaluation of estimated runoff and NPS. The estimated Nash-Sutcliffe coefficient (NSE) values were over 0.6 for runoff, BOD, TN, and TP for most sites and watershed. The calibrated model was further extended to other counties for pollutant load potential evaluation. Pollutant load potential maps were developed and target areas were identified. As shown in this study, the L-THIA 2012 can be used for evaluation runoff and pollutant loads with limited data sets and its estimation could be used in identifying pollutant load hot spot areas for implementation of site-specific Best Management Practices.

Development of Pollutant Loading Estimation System using GIS (GIS를 이용한 유역별 오염부하량 산정시스템의 개발)

  • Ham, Kwang-Jun;Kim, Joon-Hyun;Shim, Jae-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.3
    • /
    • pp.97-107
    • /
    • 2005
  • The purpose of this study is to develop a system, which estimates watershed pollutant loading rate through the combination of GIS and computational mode. Also, the applicability of this study was estimated by the application of the above system for Chuncheon City. The detailed results of these studies are as follows; The pollutant loading estimation system was developed for more convenient estimation of pollutant loading rate in watershed, and the system load was minimized by the separation of estimation module for point and non-point source. This system on the basis of GIS is very economical and efficient because it can be applied to other watershed with the watershed map. System modification is not needed. The pollutant loading estimation system for point source was developed to estimate the pollutant loading rate in watershed through the extraction of the proper data from all districts and yearly data and the execution of spatial analysis which is main function of GIS. From the verification result of spatial analysis, real watershed area and the administrative districtarea extracted by spatial analysis were $1,114,893,340.15m^2$ and $1,114,878,683.68m^2$, respectively. It shows that the spatial analysis results were very exact with only 0.001% error. The pollutant loading estimation system for non-point source was developed to calculate the pollutant loading rate through the overlaying of land-use and watershed map after the construction of new land-use map using the land register database with most exact land use classification. Application result for Chuncheon City shows that the proposed system results in one percent land use error while the statistical method results in five percent. More exact nonpoint source pollutant loading was estimated from this system.

Analysis of Pollutant load Reduction Efficiency with Riparian Buffer System Using the SWAT-REMM (SWAT-REMM을 적용한 수변림 조성에 따른 하천오염부하 저감효과 분석)

  • Choi, Youn Ho;Ryu, Ji Chul;Hwang, Ha Sun;Kum, Dong Huyk;Park, Youn Shik;Jung, Young Hun;Choi, Joong Dae;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.2
    • /
    • pp.166-180
    • /
    • 2015
  • Pollutant in watersheds comes from two major sources which are NPS (nonpoint source pollution) and PS (point source pollution). Most of the pollutant can be treated by wastewater treatment plants. However, wastewater treatment plants may not be an appropriate practice to improve water quality for the watersheds with large portion of NPS pollutant and NPS pollution from direct runoff and baseflow has different characteristics. Therefore the practices to improve water quality need to be comprehensive for pollutants by both direct runoff and baseflow. Riparian buffer, one of practices to manage pollutant in watershed, has been applied to reduce pollutant not only from direct runoff but also baseflow. In this study, the scenarios for pollutant reduction by wastewater treat plants and the nitrogen reduction by riparian buffer were simulated using SWAT-REMM to suggest an effective plan for pollutant reduction from baseflow. Riparian buffer provided nitrogen reduction of 0.2~75.0% in YbB watershed and 38.0~47.0% in GbA watershed. The result indicates that riparian buffer is effective to reduce the pollutant especially from baseflow, and it suggested as suitable for the a watershed which WWTP discharge is not capable to reduce enough pollutant.

Dischatge Loads of Nonpoint Source Pollutant in the Upper Watershed of Inigation Reservoir - Case Study of the Goseong Reservoir - (농업용 저수지 상류유역의 비점원오염 유출부하량 산정 - 고성저수지를 대상으로 -)

  • Kim, Jin-Ho;Han, Kuk-Heon;Ryu, Jong-Soo;Jung, Goo-Bok;Kwun, Soon-Kuk
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.324-331
    • /
    • 2007
  • This study was conducted to evaluate the influence of pollutant loads on the water quality in the Goseong reservoir from May 2005 to October 2006. Annual total runoff at the Goseong-cheon watershed was 968.0 mm in 2005, 382.6 mm in 2006, respectively. The mean concentration of BOD, COD and SS in the stream were 2.28, 6.03, 46.97 mg/L in rainy seasons and 0.95, 2.14, 6.05 mg/L in dry seasons at SWT C sub-watershed. Total-N concentrations ranged from 2.60 to 3.18 mg/L at SWT C sub-watershed, which was generally higher than the quality standard of agricultural water (1.0 mg/L). Total-P concentrations ranged from 0.044 to 0.130 mg/L at SWT C sub-watershed. Measured pollutant loads in the SWT C sub-watershed were 36.7 kg/day of BOD, 72.3 kg/day of T-N and 2.3 kg/day of T-P in 2005 at SWT C sub-watershed, 63.9 kg/day of BOD, 82.8 kg/day of T-N and 1.1 kg/day of T-P in 2006 at SWT C sub-watershed, respectively. In the analysis of the effluent characteristics for NPS pollutants, it appeared that the loading rates of effluent from SWT C watershed were, respectively, BOD 62.3%, T-N 69.6%, T-P 71.1%, SS 70.1% during the rainy season in 2006. The calculated T-N daily pollutant loadings by the unit loading factor method from each sub-watershed were much greater than observed, but the calculated T-P daily pollutant loadings much lesser than observed.