Comparison of Characteristics of Nonpoint Source Pollution from Separate and Combined Sewer System (합류식 월류수와 분류식 우수유출수의 비점오염물질 유출특성 비교)

  • Shin, Min Hwan;Jeon, Ji-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.97-106
    • /
    • 2017
  • In this study, the characteristics of nonpoint source pollutant loads from separate sewer overflow (SSO) and combined sewer overflow (CSO) were evaluated during 2016 in Namyangju city, Korea. Five rainfall events were monitored during 2016 with ranging from 14.5 mm to 121.5 mm. The runoff ratio of CSO was higher than that of SSO because only design volume of maximum sanitary sewer ($1Q_h$) was transported and treated and $2Q_h$ was overflowed to waterbody during rainy day although combined sewer system was designed to transport $3Q_h$ to treatment system. The event mean concentrations (EMCs) and pollutant loads from CSO were higher than those from SSO. BOD and COD of CSO, and TOC and TN of SSO represented distinct first flush phenomena. The inadequate management in combined sewer system from which the untreated $2Q_h$ from CSO was overflowed to waterbody during rainy day could influence on high pollutant loads and first flushing. Treating $2Q_h$ from CSO, source control such as low impact development, and treating outflow from SSO were strongly recommended to control non-point source pollution in urban area.

Development of Excel Based PADDIMOD2 for Estimating Nonpoint Source Pollutant Loadings from Paddy Rice Fields (논에서의 비점오염부하 예측을 위한 엑셀기반의 PADDIMOD2 개발)

  • Jeon, Ji-Hong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.4
    • /
    • pp.11-19
    • /
    • 2011
  • PADDIMOD2 was deloped to estimate nonpoint source pollution from paddy rice fields. The PADDIMOD2 was enhanced to estimate runoff and pollutant load during non-growing as well as growing season and to be easily used for public by development of Excel based system. Nutrient concentration and hydrology were based on Dirac delta function and continuous source function, and tank model for growing season and Event Mean Concentrations (EMCs) and SCS-Curve Number method for non-growing season. The PADDIMOD2 consists of three main component (input data, parameters data, and output data) by including eight Excel spread sheets. As a result of model application, total precipitation and irrigation were 1,051.7 mm and 439.2 mm, respectivley and surface runoff and water loss including infiltration and evapotranspiration were 463.0 mm and 947.9 mm, respectively. Annual nutrient loadings of T-N and T-P from study area were 6.7 kg/$km^2$/day and 0.5 kg/$km^2$/day, respectively. Development of PADDIMOD2 was focused on minimizing input data and maximizing user friendly system and is expected to be useful tool to evaluate various non-structure BMPs and estimate unit load from paddy rice fields for application at Korean TMDL.

Analysis of Nonpoint source Reduction at Andong Area Considering Changes in CN (CN의 변화에 따른 안동시 물순환 선도도시 조성계획의 비점오염부하 저감효과 분석)

  • Kwon, Heongak;Jung, Kangyoung;Kim, Shin;Shin, Sukho;Ahn, Jungmin;Kim, Gyeonghoon
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.342-349
    • /
    • 2016
  • Andong belongs to the Nakdong River Basin, Nakdong River is flowing through the city, including Andong dam and Imha dam. The runoff due to provincial transfer and impervious area has been increasing by urbanization increases and nonpoint source loads. In this study, we evaluate the runoff and nonpoint pollution loads in accordance with the development targeted at selected urban water cycle leading to Andong city. Andong city leading to the water cycle plan to evaluate the directly runoff and BOD, T-N and T-P nonpoint pollutant loads using the CN into account the temporal and spatial changes. Evaluation, direct runoff per year is 10.41 % if the green roof and a water permeable pavement replacement, water cycle parks and streets compositions, City impermeable layer improvements to be business including four kinds of scenario is applied to both the development and the BOD non-point pollutant loads 20.56%, T-N 9.55% and T-P pollution and nonpoint loads was investigated to be reduced 14.29%. Four kinds of low lapse rate of the development scenario of the highest thing urban impervious surface was investigated by improving business development prior year annual direct runoff is 6.25 %, BOD nonpoint pollution loads are 11.84%, T-N nonpoint pollution loads are 4.46 % and T-P was investigated by reducing pollutant loads to be 10.20%.

Development and experimental verification of vortex typed nonfilter nonpoint source pollution reduction device (와류형 미필터 비점오염저감장치의 개발과 실험적 검증)

  • Jang, Suk Hwan;Lee, Jae-Kyoung;Lee, Hae-Kwang;Hwang, Sung-Gyu
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.265-277
    • /
    • 2019
  • The objective of this study was to develop and verify an effective vortex typed nonfilter nonpoint source pollution reduction device. To verify this pollution reduction device, a total of twelves scenarios (three rainfall intensities${\times}$two states${\times}$two steps) of experiments were conducted using pollutants. First, simulated inflow (rainfall intensity 2.5 mm/hr: $0.00152m^3/s$, rainfall intensity 3.395 mm/hr: $0.00206m^3/s$, rainfall intensity 6.870 mm/hr: $0.00326m^3/s$) was calculated. Second, pollutants (mixture of 25% of four particle sizes) were selected and injected. Third, pollutant removal efficiencies of this device at its initial state and operating states were measured. As a result of analysis based on rainfall intensity, the concentration of pollutants was decreased by the device at initial and operating states at all rainfall intensities. Its pollutant removal efficiency was more than 80%, the standard set by the Ministry of Environment. Its pollutant removal efficiency was gradually increased over time, reaching approximately 90%. Its pollutant removal efficiency was higher in its operating state than that in its initial state. Therefore, nonpoint source pollutants can be effectively removed by this vortex typed nonpoint source pollution reduction device developed in this study.

Estimation of Optimal Size of the Treatment Facility for Nonpoint Source Pollution due to Watershed Development (비점오염원의 정량화방안에 따른 적정 설계용량결정)

  • Kim, Jin-Kwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.149-153
    • /
    • 2008
  • The pollutant capacity occurred before and after the development of a watershed should be quantitatively estimated and controlled for the minimization of water contamination. The Ministry of Environment suggested a guideline for the legal management of nonpoint source from 2006. However, the rational method for the determination of treatment capacity from nonpoint source proposed in the guideline has the problem in the field application because it does not reflect the project based cases and overestimates the pollutant load to be reduced. So, we perform the standard rainfall analysis by analytical probabilistic method for the estimation of an additional pollutant load occurred by a project and suggest a methodology for the estimation of contaminant capacity instead of a simple rational method. The suggested methodology in this study could determine the reasonable capacity and efficiency of a treatment facility through the estimation of pollutant load from nonpoint source and from this we can manage the watershed appropriately. We applied a suggested methodology to the projects of housing land development and a dam construction in the watersheds. When we determine the treatment capacity by a rational method without consideration of the types of projects we should treat the 90% of pollutant capacity occurred by the development and to do so, about 30% of the total cost for the development should be invested for the treatment facility. This requires too big cost and is not realistic. If we use the suggested method the target pollutant capacity to be reduced will be 10 to 30% of the capacity occurred by the development and about 5 to 10% of the total cost can be used. The control of nonpoint source must be performed for the water resources management. However it is not possible to treat the 90% of pollutant load occurred by the development. The proper pollutant capacity from nonpoint source should be estimated and controlled based on various project types and in reality, this is very important for the watershed management. Therefore the results of this study might be more reasonable than the rational method proposed in the Ministry of Environment.

Planning for Adapting to the Rural Region Impacts of Climate Change - Case study in Yesan - (기후변화에 따른 농촌지역 영향 및 대응방안 연구 - 예산군을 대상으로 -)

  • Lee, Gyeong-Jin;Cha, Jung-Woo
    • Journal of Korean Society of Rural Planning
    • /
    • v.19 no.4
    • /
    • pp.115-123
    • /
    • 2013
  • Owing to increase of meteorological disasters by climate change, it needs to study of climate change which will be able to deal with adaption for basic local authorities. A case study area of Yesan have been impacted by land-use which alter natural environment demage. It has led to micro-climate change impacts in rural area, Yesan. In order to adapt to the effects, this paper estimated temperature change in productivity of fruits and conducted decline of nonpoint pollutant loadings. As the results of temperature change of effecting on growth of apple, since a rise in temperature have not increased high, therefore the apple productivity could not be influence until 2030s. While the apple productivity could be declined 14.8% in 2060s. In addition, it supposes that the productivity would be decreased 44.5% in 2090s. Furthermore, it showed that the apple maturity has become worse, because length of high temperature has dramatic increased 54.2% in 2030s, 103.2% in 2060s and 154.0% in 2060s beside 2000, respectively, compared with 2000. As results of analysing between the future rainfall characteristics and nonpoint pollutant loadings, the subject of reduction of nonpoint pollutant was efficiency when it implemented around Oga-myeon or Deoksan-myeon Dun-ri. This study classified the region more detail each Eup and Myeon after that it analysed the rural region impacts of climate change for basic local authorities. Hence, this study is able to predict adaptation of rural region impacts of climate change. Due to increase of green house gases emission, meteorological disasters could often occur in the future. Therefore, it needs follow-up studies that assess climate change of effecting on rural region.

The Characteristics of Water Quality and the Estimation of Pollutant Loadings from the Flowing Streams in Cheju Island (제주도내 유수하천에 대한 수질특성 및 오염부하량 산정)

  • 조은일;오윤근
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.845-851
    • /
    • 1998
  • In order to manage the water quality from the flowing streams in Cheju Island, the characteristics of water quality was investigated from August, 1996 to May, 1997 and the pollutant loadings for future were estimated from the watershed at each stream. Comparing the mean concentrations of each water quality with the criterion of water quality in river, it was under I class except for Changgo Stream, for DO, under I class at the whole station for SS and under II class for BOD. As the pollutant loadings at each stream in 2020 is compared with those in 1996, the estimated results are as follows : 1) for BOD, 59% at Donghong Stream, 24% at Yeonoe Stream, 44% at Ohngpo Stream and 57% at Changgo Stream. 2) for T-N, 91% at Donghong Stream, 76% at Yeonoe Stream, 63% at Ohngpo Stream and 89% at Changgo Stream. 3) for T-P, 69% at Donghong Stream, 42% at Yeonoe Stream, 45% at Ohngpo Stream and 73% at Changgo Stream. The point source loadings discharged through combined sewer could be treated at sewage treatment plant. However, the expected slow decreasing rate of BOD, T-N, and T-P loadings is due to the part of untreated nonpoint source loadings. Nonpoint source loading overflow typically occurs when the flow of stormwater combined with sewage exceeds the capacity of the interceptor sewers. Since most of the sewers used in Cheju Island are the combined sewers, the combined overflow sewage is bypassed into the receiving water area after a rainstorm. Therefore, a means to control nonpoint source loadings should be considered for the river and marine water quality management.

  • PDF

Determination of EMCs and Comparison with Sampled Concentrations in Paved Areas (포장지역에서의 강우사상별 EMC 산정 및 단순 샘플농도와의 비교)

  • Lee, Eun-Ju;Ko, Seok-Oh;Kang, Hee-Man;Lee, Joo-Kwang;Lee, Byung-Sik;Lim, Kyeong-Ho;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.104-109
    • /
    • 2006
  • TPLMS programs in four large rivers have been developed to improve the water quality from possible pollutants originated from watershed areas. The success of TPLMS program is depended on nonpoint source control. Currently, the pollutant loading from nonpoint pollution sources is gradually increasing as developing the nearby watershed. However, there are not enough data concerning on nonpoint pollution in Korea because of lacking of monitoring activities. It is the main reason of uncertainty. Therefore, this manuscript will summarize the EMCs in various landuses based on monitoring program. Also the EMC in each paved area will be compared and discussed to find the differences. When the EMC is compared by average monitored sample concentrations, the EMC values are 2-4 times higher than sample concentrations. It means the monitoring program is very important in the field of nonpoint pollution. The pollutant loadings from bridge landuse is higher than loadings from parking lot and highway because of more traffic activities.