• Title/Summary/Keyword: Nondestructive measurement

Search Result 588, Processing Time 0.032 seconds

A Comparative study on Dynamic & Static elastic modulus of cement mortar specimens (시멘트 모르타르 재료의 동탄성계수와 정탄성계수 비교 연구)

  • O, Seon-Hwan;Kim, Hyoung-Soo;Jang, Bo-An;Suh, Man-Cheol
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.2
    • /
    • pp.127-138
    • /
    • 2000
  • This study was conducted to examine the differences between dynamic and static elastic constants by use of some laboratory tests of cement mortar specimens which have different water/cement mixing ratios. Specific gravity measurement, ultrasonic velocity estimating and uniaxial compression test were adopted to acquire the dynamic and static elastic constants. Digital data acquisition and processing enhanced the accuracy of estimating the velocities of specimens drastically, Also, the method using the gradient of propagation delay time in according to increment of specimen length more enhanced the accuracy than the method using the only one specimen length over total propagation time. The correlation between density and the P and S wave velocity of specimens shows reliable positive relation and the correlation between density and the strength of uniaxial compression has the similar relationship. The dynamic Young's modulus $(E_D)$ is alway greater than the static Young's modulus $(E_S)$ and there is increasing tendency of the ratio $(E_D/E_S)$ according to the increase of density or strength of the specimens. On the other hand, there is no typical relationship between dynamic Poisson's ratio $({\nu}_D)$ and static Poisson's ratio $({\nu}_S)$ and just the ratio of ${\nu}_D/{\nu}_S$ ranges front 69 to 122 %.

  • PDF

3-D Analysis of Semiconductor Surface by Using Photoacoustic Microscopy (광음향 현미경법을 이용한 반도체 표면의 3차원적 구조 분석)

  • Lee, Eung-Joo;Choi, Ok-Lim;Lim, Jong-Tae;Kim, Ji-Woong;Choi, Joong-Gill
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.553-560
    • /
    • 2004
  • In this experiment, a three dimensional structure analysis was carried out to examine the surface defects of semiconductor made artificially on known scale. It was investigated the three dimensional imaging according to the sample depth and the thermal diffusivity as well as the carrier transport properties. The thermal diffusivity measurement of the intrinsic GaAs semiconductor was also analyzed by the difference of frequency-dependence photoacoustic signals from the sample surface of different conditions. Thermal properties such as thermal diffusion length or thermal diffusivity of the Si wafer with and without defects on the surface were obtained by interpreting the frequency dependence of the PA signals. As a result, the photoacoustic signal is found to have the dependency on the shape and depth of the defects so that their structure of the defects can be analyzed. This method demonstrates the possibility of the application to the detection of the defects, cracks, and shortage of circuits on surface or sub-surface of the semiconductors and ceramic materials as a nondestructive testing(NDT) and a nondestructive evaluation(NDE) technique.

Pulsatility Index of Blood Echogenicity of the Human Radial and Common Carotid Arteries: Relation with Age and Stroke (인체 요골동맥과 경동맥의 혈액에코박동지수: 나이 및 뇌졸중과의 관계)

  • Bok, Tae-Hoon;Kong, Qi;Nam, Kweon-Ho;Choi, Jay Chol;Paeng, Dong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.494-501
    • /
    • 2012
  • In the present paper, the ultrasound blood images were measured at both the human radial artery(RA) and common carotid artery(CCA), depending on the age, and the pulsatility index of blood echogenicity(PIBE) was analyzed. In addition, the ultrasound blood images were measured at both RA and CCA of both the stroke patients and the control group, and PIBE was compared. PIBE of RA for the young group was similar with that for the old group ($0.13{\pm}0.11$ and $0.16{\pm}0.03$). PIBE of CCA for the young group, however, was larger than that for the old group ($0.70{\pm}0.21$ and $0.32{\pm}0.01$), and was more variable depending on the subject. Similarly, the fibrinogen concentrations of the patients ($336{\pm}61$ and $340{\pm}126mg/dl$) were more than that of the control group ($264{\pm}38$ and $257{\pm}43mg/dl$), for both RA and CCA. The results indicate the possibility of the ultrasonic test on the correlation between erythrocyte aggregation and stroke, and it is expected that the in-vivo EA measurement would be clinically useful.

Serviceability Assessment of a K-AGT Test Bed Bridge Using FBG Sensors (광섬유 센서를 이용한 경량전철 교량의 사용성 평가)

  • Kang, Dong-Hoon;Chung, Won-Seok;Kim, Hyun-Min;Yeo, In-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.305-312
    • /
    • 2007
  • Among many types of light rail transits (LRT), the rubber-tired automated guide-way transit (AGT) is prevalent in many countries due to its advantages such as good acceleration/deceleration performance, high climb capacity, and reduction of noise and vibration. However, AGT is generally powered by high-voltage electric power feeding system and it may cause electromagnetic interference (EMI) to measurement sensors. The fiber optic sensor system is free from EMI and has been successfully applied in many applications of civil engineering. Especially, fiber Bragg grating (FBG) sensors are the most widely used because of their excellent multiplexing capabilities. This paper investigates a prestressed concrete girder bridge in the Korean AGT test track using FBG based sensors to monitor the dynamic response at various vehicle speeds. The serviceability requirements provided in the specification are also compared against the measured results. The results show that the measured data from FBG based sensors are free from EMI though electric sensors are not, especially in the case of electric strain gauge. It is expected that the FBG sensing system can be effectively applied to the LRT railway bridges that suffered from EMI.

Bulk Shear-Wave Transduction Experiments Using Magnetostrictive Transducers with a Thin Fe-Co Alloy Patch (철-코발트 합금 패치로 구성된 자기변형 트랜스듀서를 이용한 체적 전단파 발생 및 측정)

  • Park, Jae-Ha;Cho, Seung-Hyun;Ahn, Bong-Young;Kwon, Hyu-Sang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1075-1081
    • /
    • 2010
  • Recently, the results of many studies have clarified the successful performance of magnetostrictive transducers in which a ferromagnetic patch is used for the transduction of guided shear waves; this is because a thin ferromagnetic patch with strong magnetostriction is very useful for generating and detecting shear wave. This investigation deals with bulk shear wave transduction by means of magnetostriction; on the other hand, the existing studies have been focused on guided shear waves. A modular transducer was developed; this transducer comprised a coil, magnets, and a thin ferromagnetic patch that was made of Fe-Co alloy. Some experiments were conducted to verify the performance of the developed transducer. Radiation directivity pattern of the developed transducer was obtained, and a test to detect the damage on a side drill hole of a steel block specimen was carried out. From the results of these tests, the good performance of the transducer for nondestructive testing was verified on the basis of the signal-to-noise ratio and narrow beam directivity.

Elemental Analysis by Neutron Induced Nuclear Reaction - Prompt Gamma Neutron Activation Analysis for Chemical Measurement - (중성자 핵반응을 이용한 원소 검출기술 - 즉발감마선 중성자 방사화분석법을 이용한 검출기술 -)

  • Song, Byung Chul;Park, Yong Joon;Jee, Kwang Yong
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.1041-1051
    • /
    • 2003
  • Neutron induced prompt gamma activation analysis (PGAA) offers a nondestructive, sensitive and relatively rapid method for the determination of trace and major elements and is proven to be convenient for online analysis of minerals, metals, coal, cement, petrochemical, coating, paper as well as many other materials and products. The technique has found many uses in medicine, industry, research, security and the detection of contraband items. This report reviews the present status and future trends of the PGAA techniques. Requirements for the system are neutron source, high resolution HPGe detectors with a high-voltage power supply, an amplifier, analog-to-digital converter, and a multichannel analyzer for the detection and measurement of prompt ${\gamma}$-ray emit form the neutron capture elements. Introducing a ${\gamma}$-${\gamma}$ coincidence system also improves the quality of the ${\gamma}$-ray spectrum by suppressing the background created from the Compton scattering of high energy prompt ${\gamma}$-rays. A PGAA system using a $^{252}Cf$ neutron source is currently under construction for the on-line measurement of several elements in aqueous samples at KAERI. The system can be applied for the detection of chemical weapons and explosives as well as various narcotics.

Development of non-destructive freshness measurement system for eggs using PLC control and image processing (PLC제어와 영상처리를 이용한 계란의 비파괴 신선도 측정 시스템 개발)

  • Kim, Tae-Jung;Kim, Sun-Jung;Lee, Dong-Goo;Lee, Jeong-Ho;Lee, Young-Seok;Hwang, Heon;Choi, Sun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.2
    • /
    • pp.162-169
    • /
    • 2019
  • Non-destructive freshness measurement using spectroscopy has been carried out several times, but research on freshness and freshness has not been conducted. Therefore the purpose of this study is to develop a system for visually measuring and quantifying the air sack inside the egg by non - destructive method. The experimental environment which designed a small chamber was composed of 850nm band of two IR lasers, IR camera and two servo motors to acquire air sack Images. When the air sack volume ratio is 2.9% or less and the density is 0.9800 or more, the Haugh Unit value is 60 or more It was judged to be a fresh egg of a grade B or higher. These results mean, using the weight measurement, nondestructive decision system, and freshness evaluating algorithm. It can be expected to distinguish grade B or more marketable eggs without using destructive methods.

The analysis of oat chemical properties using visible-near infrared spectroscopy

  • Jang, Hyeon Jun;Choi, Chang Hyun;Choi, Tae Hyun;Kim, Jong Hun;Kwon, Gi Hyeon;Oh, Seung Il;Kim, Hoon;Kim, Yong Joo
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.5
    • /
    • pp.715-722
    • /
    • 2016
  • Rapid determination of food quality is important in food distribution. In this study, the chemical properties of oats were analyzed using visible-near infrared (VIS-NIR) spectroscopy. The objective of this study was to develop and validate a predictive model of oat quality by VIS-NIR spectroscopy. A total of 200 oat samples were collected from domestic and import markets. Reflectance spectra, moisture, protein, fat, Fe, and K of oat samples were measured. Reflectance spectra were measured in the wavelength range of 400 - 2,500 nm at 2 nm intervals. The reflectance spectrum of an oat sample was measured after sample cell and reflectance plate spectrum measurement. Preprocessing methods such as normalization and $1^{st}$ and $2^{nd}$ derivations were used to minimize the spectroscopic noise. The partial-least-square (PLS) models were developed to predict chemical properties of oats using a commercial software package, Unscrambler. The PLS models showed the possibility to predict moisture, protein, and fat content of oat samples. The coefficient of determination ($R^2$) of moisture, protein, and fat was greater than 0.89. However, it was hard to predict Fe and K concentrations due to their low concentrations in the oat samples. The coefficient of determinations of Fe and K were 0.57 and 0.77, respectively. In future studies, the stability and practicability of these models should be improved by using a high accuracy spectrophotometer and by performing calibrations with a wider range of oat chemicals.

Fundamental Parameter 법에 의한 만장굴용암 쌍자석주의 형광X선분포

  • ;Ko, Mun-Ok;Kim, Gyung-Sik
    • Journal of the Speleological Society of Korea
    • /
    • v.19 no.20
    • /
    • pp.29-62
    • /
    • 1989
  • Cheju Island, which was formed by volcanic activity, is an oval in its shape with the major axis 80km and the minor axis of 40km. The island holds in its heart Mt. Hanala rising 1,950m above the sea. Petrological study of this volcanic island has been made actively by Sang-Man Lee, Chong-Kwang Won and Moon-Won Li. The chronological measurements of the island by Chong-Kwan Won and Moon-Won Lee showed that it is composed of Sanbangsan trachytes and Backlokdam trachytes(25,000 year ago). These reports are based on the chemical analysis and the rediometric chronological measurements on the ground. However, there has been no reports about the inside of caves. We made an (composition) analysis of the inside of Manjang Cave by the fundamental parameter method in X-ray fluorescence spectrometry. The fundamental parameter method in X-ray fluorescence spectrometry is nondestructive analysis. and it enables us to make the values processed by a computer. The results obtained by this methods are as follows: SiO$_2$(49%), $Al_2$O$_3$(17%), Fe$_2$O$_3$(13%), CaO(8.1%), MgO(5.5%), Na2O(3.6%), TiO$_2$(2.1%), $K_2$O(0.86%), P$_2$O$_{5}$(0.28%), and MnO(0.20%) respectively. The data obtained by the fundamental parameter method in X-ray fluorescene was compared with the data provided by Chong-Kwan Won and Moon-Won Lee. Our measurement was made by K-Ar-method in cooperation with T. ITAYA. The samples are of 30,000-420,000 years ago. The composition of the values of our underground analysis with the existing values obtained by the analyses on the ground produced new data about Cehju volcanic island.d.

  • PDF

Development of Deterioration Diagnosis System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화진단시스템 개발)

  • 김성덕;이승호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.43-50
    • /
    • 2000
  • Design and experiments of a nondestructive testing system with a solenoid eddy current sensor to inspect deterioration of ASCR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wires) usually used in HV overhead distribution lines in domestic areas in presented in this paper. Through corrosion mechanisms and deterioration results for ACSR-OC conductors are examined, it is shown that corrosion may lead to the reduction of the effective cross section area of conductors is proposed. The measurement system consisting of a constant current source with a RF frequency, a signal processing unit and a motor driver/ controller is designed and implemented. This instrument has such capabilities as detecting the sensor output and estimating diameter change of the testing conductors, continuously. As a result, it was verified that such corrosion detector system with an eddy current sensor can be shown good effectiveness for estimating the serious faults due to deterioration in overhead distribution lines and giving an early warming before severe aged conductor may lead to fail.

  • PDF