• 제목/요약/키워드: Nondestructive measurement

검색결과 587건 처리시간 0.023초

Assessing the Nano-Dynamics of the Cell Surface

  • Bae, Chil-Man;Park, Ik-Keun;Butler, Peter J.
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.263-268
    • /
    • 2012
  • It is important to know the mechanism of cell membrane fluctuation because it can be readout for the nanomechanical interaction between cytoskeleton and plasma membrane. Traditional techniques, however, have drawbacks such as probe contact with the cell surface, complicate analysis, and limit spatial and temporal resolution. In this study, we developed a new system for non-contact measurement of nano-scale localized-cell surface dynamics using modified-scanning ion-conductance microscopy. With 2 nm resolution, we determined that endothelial cells have local membrane fluctuations of ~20 nm, actin depolymerization causes increase in fluctuation amplitude, and ATP depletion abolishes all membrane fluctuations.

초음파법에 의한 저탄소강의 페라이트 결정립 크기 측정 (Measurement of Ferrite Grain Size by Ultrasonic Method in Low Carbon Steel)

  • 홍순택;권숙인;주웅용
    • 열처리공학회지
    • /
    • 제12권2호
    • /
    • pp.157-165
    • /
    • 1999
  • Grain size of steels is one of the most important parameters which influence yield strength and fracture toughness. Ultrasonic wave propagating in polycrystalline materials is mostly attenuated by scattering at grain boundary. Effect of ultrasonic attenuation on average ferrite grain size of carbon steels with tensile strength $40{\sim}60kgf/mm^2$ consisting of multi phases such as ferrite + pearlite and ferrite + pearlite + bainite was evaluated. The attenuation of these steels rapidly increased with average ferrite grain diameter. Average ferrite grain diameter ($D_{av}$, ${\mu}m$) could be expressed as $1.79+22.97*a^{1/2.03}$, where a is attenuation with unit of nepers/cm. From this study, it was confirmed that nondestructive ultrasonic method could be used in measuring average ferrite grain size indirectly.

  • PDF

초음파의 가시화에 의한 진동자의 공진주파수 측정에 관한 연구 (The Measurement of the Resonance Frequency of Transducer by Ultrasonic Visualization)

  • 이범성;한응교;송창섭
    • 비파괴검사학회지
    • /
    • 제13권3호
    • /
    • pp.14-23
    • /
    • 1993
  • 가시화 시험을 통하여 시험편에 부착된 초음파 진동자의 공진주파수의 측정을 시도하였다. 그 결과 시험편에 부착되어 있는 진동자의 공진주파수는 진동자 자체만의 공칭 공진주파수 보다 훨씬 낮게 나타났고, 그 정도는 주파수가 높은 진동자일수록 심하게 나타나는 것을 볼 수 있었는데, 이론적인 해석에 의한 검증 결과 그 원인이 진동자 보호용 알루미늄 판재의 공진에 의한 것으로 판명되었다.

  • PDF

Study on Highly Accuracy Quality Evaluation of Spot Weld by use of Image Processing Technique

    • 한국생산제조학회지
    • /
    • 제5권4호
    • /
    • pp.38-46
    • /
    • 1996
  • This paper discusses the feasibility of Ultrasonic Nondestructive Evaluation (UNDE) technique for sport weld quality. Ultrasonic c-scan image assisted by image processing technique was used for Nondestructive Evaluation(NDE) of spot weld quality. Ultrasonic testing results obtained were confirmed and compared by Optical Microscope and SAM(Scanning Acoustic Mircroscope) observation of the spot-weld cross section, The results show that the nugget dinameter can be successfully measured with the accuracy of 0.5mm. It was ascertained that ultrasonic c-scan technique is very effective method for the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget. Additional support for the above conclusions is provided by the results for galvanized steel. The ultrasonic results for galvanized welds generally correspond to the results for uncoated steel. Finally, it was found that the above-mentioned technique can be sufficiently applied to NDE method for securing the Quality Assurance(QA) of spot welded products in production line.

  • PDF

레이저 스페클 간섭법을 이용한 면내 변형 측정 및 해석에 대한 연구 (I) (A Study on Measurement and Analysis of In-Plane Deformations by Using Laser Speckle Interferometry (I))

  • 강영준;노경완;강형수
    • 한국정밀공학회지
    • /
    • 제15권11호
    • /
    • pp.121-129
    • /
    • 1998
  • In-plane ESPI(Electronic Speckle Pattern Interferometry) was devised to measure in-plane deformations and rotation of a specimen with laser in this study. ESPI is a optical measuring method to be able to measure the deformations of engineering components and materials in industrial fields. The conventional measuring methods of surface deformations such as the strain gauge have many demerits because they are contact and point-to-point measuring ones. But that ESPI is noncontact, nondestructive and whole field measuring method can overcome previous disadvantages. We used ESPI which is sensitive to in-plane displacement for measuring in-plane deformations of a disk. And the 4-frame phase shifting method was used for the quantitative analysis. First of all, the system calibration was done due to an in-plane rotation before getting deformations of a disk. Finally we showed good agreement between the experiment results and those of the FEA(Finite Element Analysis).

  • PDF

Sensitive NDE of Small Fatigue Cracks

  • Saka, Masumi
    • 비파괴검사학회지
    • /
    • 제21권1호
    • /
    • pp.22-31
    • /
    • 2001
  • Some techniques developed recently for sizing smalt fatigue cracks are described. One is an ultrasonic technique which deals with a small closed crack, where both the stress closing the crack and the crack size are determined by analyzing inverse problem. Here, difficulties encountered in NDE of closed cracks by usual ultrasonic techniques are summarized in advance. Secondly, the closely coupled probes potential drop (CCPPD) technique, which is based on d-c potential drop measurement, is explained fur sizing small cracks. The CCPPD technique is not affected by crack closure. Finally, a discussion is given on NDE of materials degradation in conjunction with sensitive NDE of small cracks.

  • PDF

Characteristics on Temperature Evolution in the Metallic Specimen by Ultrasound-Excited Thermography

  • Choi, M.Y.;Park, J.H.;Kang, K.S.;Kim, W.T.
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.200-206
    • /
    • 2010
  • In ultrasound-excited thermography, the injected ultrasound to an object is transformed to heat and the appearance of defects can be visualized by thermography camera. The advantage of this technology is selectively sensitive to thermally active defects. Despite the apparent simplicity of the scheme, there are a number of experimental considerations that can complicate the implementation of ultrasound excitation thermography inspection. Factors including acoustic horn location, horn-crack proximity, horn-sample coupling, and effective detection range all significantly affect the detect ability of this technology. As conclusions, the influence of coupling pressures between ultrasound exciter and specimen was analyzed, which was dominant factor in frictional heating model.

Applicability of Coda Wave Interferometry Technique for Measurement of Acoustoelastic Effect of Concrete

  • Shin, Sung Woo
    • 비파괴검사학회지
    • /
    • 제34권6호
    • /
    • pp.428-434
    • /
    • 2014
  • In this study, we examined the applicability of coda wave interferometry (CWI) technique, which was developed to characterize seismic waves, to detect and evaluate change in the velocity of ultrasonic waves in concrete due to acoustoelastic effect. Ultrasonic wave measurements and compressive loading tests were conducted on a concrete specimen. The measured wave signals were processed with CWI to detect and evaluate the relative velocity change with respect to the stress state of the specimen. A phase change due to the acoustoelastic effect of concrete was clearly detected in the late-arriving coda wave. This shows that the relative velocity change of ultrasonic waves in concrete due to the acoustoelastic effect can be evaluated successfully and precisely using CWI.

Nondestructive Evaluation for Remanent Life of 1Cr-0.5Mo Steel by Reversible Permeability

  • Ryu, Kwon-Sang;Lee, Yun-Hee;Park, Jong-Seo;Baek, Un-Bong
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.206-209
    • /
    • 2012
  • Peak interval for reversible permeability is presented for nondestructively evaluating the remanent life of 1Cr-0.5Mo steel. The method to measure the peak interval of reversible permeability is based on the value of reversible permeability is the same as the differential value of the hysteresis loop. The measurement principle is based on the first harmonics voltage induced in a sensing coil using a lock-in amplifier tuned to a frequency of the exciting voltage. Results obtained for the peak interval of reversible permeability and Rockwell hardness on the aged samples decrease as aging time and the Larson-Miller parameter increase. We could estimate the remanent life of 1Cr-0.5Mo steel by using the relationship between the peak interval of reversible permeability and the Larson-Miller parameter, nondestructively.

비파괴적 방법에 의한 입자 강화 복합재료의 부피분율 평가: 와전류법 (Nondestructive Determination of Reinforcement Volume Fractions in Particulate Composites : Eddy Current Method)

  • 정현조
    • 비파괴검사학회지
    • /
    • 제18권2호
    • /
    • pp.112-120
    • /
    • 1998
  • 입자 보강 복합재료의 부피분율을 평가하기 위한 와전류 비파괴 방법을 제시하였다. 제안된 방법은 복합재의 미시구조를 설명할 수 있는 이론 모델과 와전류에 의한 전기전도도 측정을 필요로 한다. 측정한 전도도를 이론 예측값과 같게 두면 미지의 입자 부피분율이 계산된다. Mori-Tanaka 방법에 기초한 전도도 해석 모델이 소개되어 있다. 이러한 접근 방법을 SiC 입자 보강 Al 기지 ($SiC_p/Al$) 복합재에 적용하였다. 이방법으로 보강재의 부피분율을 비교적 정확하게 결정할 수 있었다. 금속간 화합물이 부피분율 평가에 미치는 영향을 논하였으며, 또한 금속간 화합물의 전도도와 기하학적 성질이 보강 입자와 같은 경우, 이 두 상의 총 부피분율을 결정할 수 있는 방법을 제시하였다.

  • PDF