• 제목/요약/키워드: Non-vacuum

검색결과 630건 처리시간 0.029초

Ni-MH 2차전지용 AB5계 수소저장합금의 소결에 따른 전극 특성 (The Electrode Characteristics of the Sintered AB5-type Metal Hydrogen Storage Alloy for Ni-MH Secondary Battery)

  • 장상민;박원;최승준;노학;최전;박충년
    • 한국수소및신에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.157-164
    • /
    • 1996
  • The AB5-type metal hydride electrodes using $(LM)Ni_{4.49}Co_{0.1}Mn_{0.205}Al_{0.205}$(LM : Lanthaniumrich Mischmetal) alloy powders(${\leq}200$mesh) which were coated with 25wt% copper in an acidic bath were prepared with or without addition of 10wt% PTFE as a binder. Prior to electrochemical measurements, the electrodes were sintered at $40^{\circ}C$ for 1 and 2hrs in vacuum with Mm(mischmetal) and sponge type Ti getters. The properties such as maximum capacity, cycle life and mechanical strength of the negative electrode have been investigated. The surface analysis of the electrode was also obtained before and after charge-discharge cycling using scanning electron microscope(SEM). From the observations of electrochemical behavior, it was found that the sintered electrode shows a lower maximum discharge capacity compared with non-sintered electrode but it shows a better cycle life. For the both electrodes with or without addition of PTFE binder, the values of mechanical strength were obtained, and their values increased with increasing sintering time. However, there is little difference of discharge capacity for both electrodes.

  • PDF

VARTM공정에서의 거시적 수지 유동의 Dual-Scale 분석 (A Dual-Scale Analysis of Macroscopic Resin Flow in Vacuum Assisted Resin Transfer Molding Process)

  • 박윤희;강문구;이우일
    • Composites Research
    • /
    • 제15권6호
    • /
    • pp.1-7
    • /
    • 2002
  • VARTM공정에서는 수지유동을 빠르게 하기 위해 투과촉진층이 사용되는데 투과촉진층과 섬유층 사이의 수지 속도차가 크다. VARTM제품은 길이에 비해서 두께가 얇으나 두 가지 다른 유통 매질 사이에 발생하는 lead-lag 유통을 관찰하기 위해서는 두께 방향을 고려한 3차원해석이 요구된다. 그런데 3차원 해석에 있어서 계산 시간이 문제가 된다. 일반 PC로 절점수가 많은 3차원 문제를 해석하려면 오랜 시간이 소요되므로 비실용적이다. 그래서 본 연구에서는 dual-scale 기법을 도입하여 전체 영역은 2.5차원으로 해석하고 주요한 관심 영역만을 3차원으로 해석하였다. 2.5차원 시뮬레이션만으로 예측하기 어려운 lead-lag 유동과 같은 특이한 유동 경향을 국부적인 3차인 해석을 통해서 발견학 수 있었다. 본 연구에서 개발된 global-local 해석기술은 일반 PC에서 적당한 계산 시간 내에 균일하지 않은 유동 매질 사이를 지나는 유동흐름의 특성 분석에 효과적으로 사용될 수 있다.

생녹혈의 건조 및 안정화 (Drying and Stabilization of Deer Blood)

  • 안용근
    • 한국식품영양학회지
    • /
    • 제22권1호
    • /
    • pp.20-28
    • /
    • 2009
  • According to traditional oriental medicine, only non-coagulated native deer blood is said to be effective, and coagulated deer blood is ineffective. Thus, a drying and tablet-producing method for deer blood was developed to maintain its physiological and therapeutic activity, and so that after drying, it can be redissolved and protected from coagulation. Proteases such as trypsin, pepsin, chymotrypsin, and aminopeptidase were added to the deer blood indicating that it coagulated in an hour, as shown by the reference. Wax gourd extract, which is high in protease, was added to the blood resulting in anticoagulation for 31 hours. Also, additions of 1% EDTA, 0.38% sodium citrate, 0.16% calcium oxalate, 1.2% ethanol, and 0.006% heparin to the deer blood resulted in anticoagulation for 1 hour, 4 hours, 2 hours, 1 hour, and 31 hours, respectively. In an experiment using 0.19% sodium citrate plus 1% wax gourd extract, and 0.006% heparin plus 1% wax gourd extract, anticoagulation was maintained for up to 72 hours. However, since heparin can not be used in food, the deer blood tablet was made with the addition of 0.19% sodium citrate and 1% wax gourd extract, followed by freeze drying. The dissolution rate for the tablet manufactured in this manner was 96.7%. And the dissolution rates for spray-dried deer blood, vacuum-dried deer blood, and marketed deer blood tablets were 85%, 81%, and 25.5%, respectively. The composition of the tablet produced from the freeze-dried deer blood was 56.4% protein, 18.7% lactose, 1.2% amino acids, 1.0% glucose, 0.7% lipids, 180 mg/100 g of iron, 13 mg/100 g of potassium, 39.1 mg/100 g of calcium, 480 mg/100 g of sodium, 368 mg/100 g of chloride, each.

Comparison of Quality of Bologna Sausage Manufactured by Electron Beam or X-Ray Irradiated Ground Pork

  • Shin, Mee-Hye;Lee, Ju-Woon;Yoon, Young-Min;Kim, Jong Heon;Moon, Byeong-Geum;Kim, Jae-Hun;Song, Beom-Suk
    • 한국축산식품학회지
    • /
    • 제34권4호
    • /
    • pp.464-471
    • /
    • 2014
  • Ground lean pork was irradiated by an electron beam or X-rays to compare the effects of two types of radiation generated by a linear accelerator on the quality of Bologna sausage as a model meat product. Raw ground lean pork was vacuum packaged at a thickness of 1.5 cm and irradiated at doses of 2, 4, 6, 8, or 10 kGy by an electron beam (2.5 MeV) or X-rays (5 MeV). Solubility of myofibrillar proteins, bacterial counts, and thiobarbituric acid reactive substance (TBARS) values were determined for raw meat samples. Bologna sausage was manufactured using the irradiated lean pork, and total bacterial counts, TBARS values, and quality properties (color differences, cooking yield, texture, and palatability) were determined. Irradiation increased the solubility of myofibrillar proteins in a dose-dependent manner (p<0.05). Bacterial contamination of the raw meat was reduced as the absorbed dose increased, and the reduction was the same for both radiation types. Differences were observed only between irradiated and non-irradiated samples (p<0.05). X-ray irradiation may serve as an alternative to gamma irradiation and electron beam irradiation.

질화탄소 표면층 및 열처리가 탄소 나노튜브 미세팁의 전계방출 및 장시간 안정성에 미치는 영향 (Effects of Carbon Nitride Surface Layers and Thermal Treatment on Field-Emission and Long-Term Stability of Carbon Nanotube Micro-Tips)

  • 노영록;김종필;박진석
    • 반도체디스플레이기술학회지
    • /
    • 제9권1호
    • /
    • pp.41-47
    • /
    • 2010
  • The effects of thermal treatment on CNTs, which were coated with a-$CN_x$ thin film, were investigated and related to variations of chemical bonding and morphologies of CNTs and also properties of field emission induced by thermal treatment. CNTs were directly grown on nano-sized conical-type tungsten tips via the inductively coupled plasma-chemical vapor deposition (ICP-CVD) system, and a-$CN_x$ films were coated on the CNTs using an RF magnetron sputtering system. Thermal treatment on a-$CN_x$ coated CNT-emitters was performed using a rapid thermal annealing (RTA) system by varying temperature ($300-700^{\circ}C$). Morphologies and microstructures of a-$CN_x$/CNTs hetero-structured emitters were analyzed by FESEM and HRTEM. Chemical composition and atomic bonding structures were analyzed by EDX, Raman spectroscopy, and XPS. The field emission properties of the a-$CN_x$/CNTs hetero-structured emitters were measured using a high vacuum (below $10^{-7}$ Torr) field-emission measurement system. For characterization of emission stability, the fluctuation and degradation of the emission current were monitored in terms of operation time. The results were compared with a-$CN_x$ coated CNT-emitters that were not thermally heated as well as with the conventional non-coated CNT-emitters.

$WS_2$고체윤활제의 합성 및 구름베어링 적용 (Synthesis of $WS_2$ Solid Lubricant and Its Application to Ball Bearing)

  • 신동우;윤대현;최인혁;김경도;정진수;정용선
    • Tribology and Lubricants
    • /
    • 제15권1호
    • /
    • pp.77-82
    • /
    • 1999
  • The processing conditions fur the synthesis of platelet W $S_2$ lubricant powder through a solid-gas reaction were optimized. The mixture of tungsten and sulfur powders were sealed in a vacuum of 10$^{-6}$ torr, prior to heat-treating at 85$0^{\circ}C$ fur 8 days. The reaction product showed a well-developed platelet W $S_2$ powder with an average size of 3.8 ${\mu}{\textrm}{m}$. The TGA/DTA analysis of the synthesized W $S_2$ powder was performed up to 120$0^{\circ}C$ at a rate of 1$0^{\circ}C$/min in flowing air (100 ${\mu}{\textrm}{m}$/min) atmosphere. The weight loss was about 6% up to 120$0^{\circ}C$ compared to the original weight. A rapid weight loss of about 5% occurred in the temperature range of 44$0^{\circ}C$ to 66$0^{\circ}C$ and an exothermic peak observed due to the transition of W $S_2$ to W $O_3$. The synthesized W $S_2$powder was coated on the commercial deep grooved ball bearing (No. 6203) to examine the effect of W $S_2$, coating layer on the noise and endurance of the ball bearing. The level of noise obtained from W $S_2$, coated-ball bearing (56 ㏈) was higher. than the value (32 ㏈) occurred in the case of greece lubrication. The endurance of the ball-bearing assembled after the coating of W $S_2$ powder onto each part increased 50 times compared to the non-coated ball-bearing..

고상확산접합된 Haynes230의 인장성질에 미치는 접합조건의 영향 (Effect of Bonding Condition on the Tensile Properties of Diffusion Bonded Haynes230)

  • 강길모;전애정;김홍규;홍성석;강정윤
    • Journal of Welding and Joining
    • /
    • 제31권3호
    • /
    • pp.76-83
    • /
    • 2013
  • This study investigated the effect of bonding temperature and holding time on microstructures and mechanical properties of diffusion bonded joint of Haynes230. The diffusion bonds were performed at the temperature of 950, 1050, and $1150^{\circ}C$ for holding times of 30, 60, 120 and 240 minutes at a pressure of 4MPa under high vacuum condition. The amount of non-bonded area and void observed in the bonded interface decreased with increasing bonding temperature and holding time. Cr-rich precipitates at the linear interface region restrained grain migration at $950^{\circ}C$ and $1050^{\circ}C$. However, the grain migration was observed in spite of short holding time due to the dissolution of precipitates to base metal in the interface region at $1150^{\circ}C$. Three types of the fracture surface were observed after tensile test. The region where the coalesce and migration of grain occurred much showed high fracture load because of base metal fracture whereas the region where those did less due to the precipitates demonstrated low fracture load because of interface fracture. The expected fracture load could be derived with the value of fracture area of base metal ($A_{BF}$) and interface ($A_{IF}$), $Load=201A_{BF}+153A_{IF}$. Based on this equation, strength of base metal and interface fracture were calculated as 201MPa and 153MPa, respectively.

LiCl-$Li_2O$ 용융염에서의 리튬의 반연속적 전기정련 (Semi-Continuous Electrowinning of LiCl-$Li_2O$ Molten Salt)

  • Jin-Mok, Hur;Chung-Seok, Seo;Sun-Seok, Hong;Dae-Seung, Kang;Seong-Won, Park
    • 방사성폐기물학회지
    • /
    • 제2권3호
    • /
    • pp.211-217
    • /
    • 2004
  • 한국원자력 연구소에서 추진하고 있는 사용후핵연료 관리 이용 기술개발의 경제성과 환경친화성을 증진시키기 위해서 리튬회수 기술을 개발하고 관련 검증실험을 수행하였다. 본 기술은 1) 환원전극과 결합된 비전도성 다공성 마그네시아 용기를 이용한 용융염상에서의 산화리튬 전해, 2) 마그네시아 용기를 용융염 액위 이상으로 상승시켜, 용기 내에 회수된 리튬의 용융염으로부터의 분리, 3) 회수된 리튬의 진공 사이펀을 사용한 별도 저장조로의 이송이라는 3단계의 결합으로 특징지어 진다. 개발된 기술에 의하여 염화리튬-산화리튬 용융염으로부터 95% 이상의 수율로 리튬을 반연속적으로 회수할 수 있었다.

  • PDF

소형 위성용 소형직류모터를 이용한 분리장치 (Release Mechanism for small satellite using micro DC motor)

  • 탁원준;조재욱;이민수;김병규
    • 한국항공우주학회지
    • /
    • 제38권8호
    • /
    • pp.767-773
    • /
    • 2010
  • 본 논문에서는 위성 본체에 장착된 탑제체를 위성으로부터 분리하기 위한 비폭발식 분리 메커니즘을 제안하였다. 작동기로서 경제적이고 신뢰성 있는 유성기어가 통합된 소형 직류모터를 채택하였다. 제안된 분리장치는 별도의 지그나 구조물 없이도 재장전이 용이 하도록 하였으며, 단순한 구조로 제작이 수월한 장점이 있다. 완성된 분리장치는 분리반응속도 측정시험, 최대분리가능하중 측정 시험, 최대발생충격 측정 시험을 통하여 그 성능을 입증하였고, 진동시험, 열진공 시험을 통하여 우주 환경에서 사용 가능함을 보여주었다. 개발된 인공위성용 비폭발식 분리장치를 통하여 그동안 사용되었던 폭발식 분리장치 등의 해외위성용 분리장치를 대체 할 수 있을 것으로 기대된다.

Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists

  • Porcel, Jose M.
    • Tuberculosis and Respiratory Diseases
    • /
    • 제81권2호
    • /
    • pp.106-115
    • /
    • 2018
  • Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (${\leq}14F$) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established.