• Title/Summary/Keyword: Non-point source water pollution

Search Result 326, Processing Time 0.033 seconds

A Study on the Analysis and Evaluation of Vulnerability Index for the Management of Nonpoint source in SoOak River Watershed (소옥천 유역 비점오염 관리를 위한 취약성 지수분석 및 평가에 관한 연구)

  • KAL, Byung-Seok;MUN, Hyun-Saing;HONG, Seon-Hwa;PARK, Chun-Dong;GIL, Han-nui;PARK, Jae-Beom
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.107-120
    • /
    • 2019
  • In this study, the characteristics of watershed and pollution source were investigated in SoOakcheon located in the upper stream of Daecheong Lake. The Dimension Index method was applied to index various watershed and pollution source data. The influence factors of each pollutant source were derived through correlation analysis between selected index and water quality monitoring data. BOD and COD were significantly influenced by population density and land area ratio, T-N by CN and rice area ratio, and T-P by population density and land area ratio, respectively. The discharge load is often used to establish non-point source countermeasures, but there is a difference between the water load and the water load in the lake or river. Therefore, in order to manage non-point pollution efficiently, it is necessary to analyze influential factors with high correlation with water quality and to manage the relevant factors with priority.

Permeable Coastal Pavement Structure for Shore Protection and Removal of Non-point Source Pollutants (연안재해 방지 및 비점오염원 유출저감을 위한 투수블록의 특성 연구)

  • Choi, Yun-Shik;Kim, Jong-Yeong;Han, Sangsoo;Kwon, Soonchul
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.597-606
    • /
    • 2019
  • Due to climate change, coastal areas are being flooded with torrential rain, typhoons, and tsunamis. In addition, non-point source pollutants (NPSs) that accumulated on the ground, streets, and buildings during the dry season are washed off by rain and stormwater runoff, which adds to the damage associated with environmental pollution, e.g., pollution that makes its way into the ocean. Recently, low impact development (LID) has been considered as a means of controlling water circulation and NPSs. In the coastal area, permeable blocks have been constructed mainly to reduce the flood damage caused by waves. Some important design factors that must be considered to ensure long-term performance are the permeability coefficient, clogging, and the efficiency of the removal of total suspended solids (TSS), but currently there are no standardized design criteria or testing techniques that are used worldwide. Herein, we analyzed the permeability coefficient and the TSS removal efficiency tendency according to the permeability area ratio with an easily-detachable, permeable block filled with calcinated yellow soils as the filter media. Our lab-scale tests indicated that, when the permeability area ratio was 25%, the reduction of the permeability coefficient after clogged was 11%, which was a significant decrease compared to other cases. Permeability persistence increased when the permeability area ratio increased from 50% to 75%. The TSS removal efficiency decreased as the permeability area ratio increased. Our pilot-scale test indicated that the TSS removal efficiency was more than 80% higher in all cases. We also found that the permeability persistence was excellent as the permeability area ratio increased, and, in actual construction, it is effective to set 5.3% of the total area as permeable area in terms of permeability and economic feasibility.

A Study on Water Quality Improvement of Hoeya Dam Reservoir Using Ecological Constructed Wetland (생태적 인공습지를 이용한 회야댐 수질개선에 관한 연구)

  • Lee, Sang-Hyeon;Cho, Yun-Chul
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.489-497
    • /
    • 2011
  • In this study the main purpose is to reduce non-point source pollution and improve water quality of Hoeya reservoir using constructed wetlands. As part of the efforts to improve water quality of the reservoir, cattail and reed-wetland cells were constructed in front of the reservoir to remove nitrogen(N) and phosphorus(P). Also, effects of hydraulic and seasonal variation on removal efficiencies of N and P were investigated. Total P and N removal efficiencies of the wetland system were approximately 20.7% and 42.7%, respectively. Removal efficiencies of N and P during the growth season (july to august) and blooming season of cattail and reed (september to october) were higher than other seasons. These results suggest that wetland system could be an effective alternative for control of non-point source pollutnat such as N and P of reservoir.

Study on the Characteristics and Non-point Source Pollution Loads in Stormwater Runoff of Shihwa Lake (시화호 유역 비점오염물질의 유출특성 및 부하량 연구)

  • Ra, Kong-Tae;Kim, Kyung-Tae;Kim, Joung-Keun;Bang, Jae-Hyun;Lee, Jung-Moo;Kim, Sung-Keun;Kim, Eun-Soo;Yun, Min-Sang;Cho, Sung-Rok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.1
    • /
    • pp.40-50
    • /
    • 2011
  • We study the characteristic and total flux of non-point pollutants such as total suspended solids (TSS), chemical oxygen demand (COD), dissolved nutrients, total phosphorus (TP) and total nitrogen (TN) in the storm water runoff from urban streams and sewer outlets of Banweol Industrial Complex around Shihwa Lake. The concentrations of non-point pollutants were generally increased with increasing of the duration and intensity of rainfall. Mean TSS concentration of Ansan stream was higher than that of sewer outlets but mean concentrations of COD, TP and TN were approximately 2~5 times higher of sewer outlet than of urban stream. TSS showed statistically positive relationships with COD and TP but it had negative correlation with dissolved nutrients. There was a significant correlation between total flux of non-point pollutants in the storm water runoff and total basin area of each sewer outlet, showing that the highest runoff flux was observed at 3rd sewer outlet which represents the largest basin area from Banweol industrial complex. Total runoff fluxes for TSS, COD, TP and TN in this study were 187,536 kg, 17,118 kg, 922 kg, 13,519 kg, respectively. Given the basin area of sewer outlet in Banweol industrial complex which corresponds only 3% from total catchment area around Shihwa Lake, enormous amount of non-point pollutants will be entered into Shihwa Lake without any treatment. It is necessary to manage and reduce of various non-point sources and pollutants because the runoff of nonpoint pollutants during storm events should be deteriorating the water quality of Shihwa Lake. Our results provides useful informations on the development of best managements practices (BMPs) for effective implementation of total pollution loads management system of Shihwa Lake.

Characteristics of Nutrient Uptake by Water Plants in Free Water Surface Constructed Wetlands for Treating Non-point Source Pollution (비점오염원 처리를 위한 자유수면형 인공습지에서 수생식물의 영양염류 흡수특성 평가)

  • Kang, Se-Won;Seo, Dong-Cheol;Choi, Ik-Won;Lee, Jun-Bae;Lim, Byung-Jin;Park, Jong-Hwan;Kim, Kap-Soon;Kim, Sang-Don;Heo, Jong-Soo;Cho, Ju-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.304-309
    • /
    • 2011
  • BACKGROUND: Generally, water plants may play an important role in nutrients(N, P) removal in constructed wetlands(CWs). Previous studies considered nutrients uptake by water plants in various CWs for treating point source pollution. On the other hand, few studies considered nutrients uptake by water plants in free water surface(FWS) CWs for treating non-point source pollution. METHODS AND RESULTS: To investigate characteristics of nutrient uptake by water plants in FWS CWs, dry weights, nutrients content and nutrients uptake by water plants were investigated from April, 2008 to October, 2008. Dominance plants were Phragmites japonica STEUD (PHRJA), Nymphaea tetragona ANGUSTA(NTMTE), Typha orientalis PRESL(TYHOR), Phragmites communis TRINIUS(PHRCO) and Zizanis latifolia TURCZ(ZIZLA) in FWS CWs. The dry weights of water plants in August were higher in the order of TYHOR(54.27 g/plant) > PHRJA(44.30 g/plant) ${\geqq}$ PHRCO(39.60 g/plant) ${\geqq}$ ZIZLA(37.80 g/plant) ${\fallingdotseq}$ NTMTE(36.75 g/plant). The T-N and T-P contents by water plants were not significantly differences regardless of cultivation period. The maximum amount of T-N uptake by water plants in August were 773 mg/plant for PHRJA, 625 mg/plant for NTMTE, 1206 mg/plant for TYHOR, 754 mg/plant for PHRCO and 768 mg/plant for ZIZLA. The maximum amounts of T-P uptake by PHRJA, NTMTE, TYHOR, PHRCO and ZIZLA were 397, 177, 411, 261 and 229 mg/plant in August, respectively. CONCLUSION(s): The results of this study suggest that optimum water plant was Typha orientalis PRESL in free water surface constructed wetlands.

The Runoff Characteristics of Non-point Pollution Sources in Industrial Complex(I): Focusing on the analysis of runoff water according to the initial rainfall of the C Industrial Complex (산업단지 비점오염원의 유출특성(I): C산업단지의 초기강우에 따른 유출수 분석을 중심으로)

  • Woo, Jae-Suk;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.1
    • /
    • pp.23-32
    • /
    • 2022
  • In this study, rainfall water outlet water quality monitoring was performed on the C industrial complex to evaluate the characteristics of non-point pollutant runoff from the industrial complex during rainfall and to use it as basic data for calculating the load and unit of non-point pollutant. As a result of the IETD analysis, it was selected as a representative rainfall event for simulating non-point pollutants when the rainfall duration was about 21 hours and the rainfall was 26.44mm. Also as a result of monitoring the flow and water quality survey, the first rainfall was 12.2 mm, the rainfall duration was 12 hr, the number of preceding dry days was 3 days, the second rainfall was 22.1 mm, the rainfall duration was 12 hr, and the number of preceding dry days was 7 days.

A study on the correlation between non-point source pollutants from the forest of Juam basin and algae bloom in the Juam lake. (주암호유역 산림기원 비점오염원물질과 주암호에 서식하는 조류번식간의 상관성 규명)

  • Kim, Nam-Jong;Shin, Dae-Yewn
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.39-48
    • /
    • 2006
  • In Juam basin, the ratio of non-point pollution source among pollutant loading of basin was significantly high, since the utilization level of land was high. In addition, the most pollutants were not treated and flowed out. In this study, the correlation between non-point source pollutants from the forest area and increasing algae was investigated. 1. Chl-a concentration flowed out to runoff from forest area and stream water was low as $0.1{\sim}20.3{\mu}g/{\ell}$ and $0.1{\sim}9.3{\mu}g/{\ell}$, respectively, and chl-a concentration ($0.1{\sim}28.5{\mu}g/{\ell}$) of branch stream was higher $5{\sim}7$ times than that of runoff from forest area. 2. In correlation between runoff from forest area and Juam lake water, annual chl-a concentration of area front Juam dam was higher twice than forest area. 3. In runoff from forest area within Juam basin, flagellate, green, diatom and blue algae occupied $33.0{\sim}41.7%$, $22.2{\sim}30.8%$, $17.3{\sim}22.5%$ and $13.7{\sim}17.6%$, respectively. 4. In runoff from forest area, both green and diatom algae were maintained constantly irrespectively of season, and flagellate algae dominated since August. 5. In characteristics by forest tree types, four types algae were inhabited in mixed forest, and flagellate algae were higher in conifer and broadleaf forest than in other area. And green algae in herbaceous forest were higher than other area.

Assessment of Water Quality using Multivariate Statistical Techniques: A Case Study of the Nakdong River Basin, Korea

  • Park, Seongmook;Kazama, Futaba;Lee, Shunhwa
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.197-203
    • /
    • 2014
  • This study estimated spatial and seasonal variation of water quality to understand characteristics of Nakdong river basin, Korea. All together 11 parameters (discharge, water temperature, dissolved oxygen, 5-day biochemical oxygen demand, chemical oxygen demand, pH, suspended solids, electrical conductivity, total nitrogen, total phosphorus, and total organic carbon) at 22 different sites for the period of 2003-2011 were analyzed using multivariate statistical techniques (cluster analysis, principal component analysis and factor analysis). Hierarchical cluster analysis grouped whole river basin into three zones, i.e., relatively less polluted (LP), medium polluted (MP) and highly polluted (HP) based on similarity of water quality characteristics. The results of factor analysis/principal component analysis explained up to 83.0%, 81.7% and 82.7% of total variance in water quality data of LP, MP, and HP zones, respectively. The rotated components of PCA obtained from factor analysis indicate that the parameters responsible for water quality variations were mainly related to discharge and total pollution loads (non-point pollution source) in LP, MP and HP areas; organic and nutrient pollution in LP and HP zones; and temperature, DO and TN in LP zone. This study demonstrates the usefulness of multivariate statistical techniques for analysis and interpretation of multi-parameter, multi-location and multi-year data sets.

Analysis of Characteristics of NPS Runoff and Pollution Contribution Rate in Songya-stream Watershed (송야천 유역의 비점오염물질 유출 특성 및 오염기여율 분석)

  • Kang Taeseong;Yu Nayeong;Shin Minhwan;Lim Kyoungjae;Park Minji;Park Baekyung;Kim Jonggun
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.4
    • /
    • pp.316-328
    • /
    • 2023
  • In this study, the characteristics of nonpoint pollutant outflow and contribution rate of pollution in Songya-stream mainstream and tributaries were analyzed. Further, water pollution management and improvement measures for pollution-oriented rivers were proposed. An on-site investigation was conducted to determine the inflow of major pollutants into the basin, and it was found that pollutants generated from agricultural land and livestock facilities flowed into the river, resulting in a high concentration of turbid water. Based on the analysis results of the pollution load data calculated through actual measurement monitoring (flow and water quality) and the occurrence and emission load data calculated using the national pollution source survey data, the S3 and S6 were selected as the concerned pollution tributaries in the Songya-stream basin. Results of cluster analysis using Pearson correlation coefficient evaluation and Density based spatial clustering of applications with noise (DBSCAN) technique showed that the S3 and S6 were most consistent with the C2 cluster (a cluster of Songya-stream mainstream owned area) corresponding to the mainstream of Songya-stream. The analysis results of the major pollutants in the concerned pollution tributaries showed that livestock and land pollutants were the major pollutants. Consequently, optimal management techniques such as fertilizer management, water gate management in paddy, vegetated filter strip and livestock manure public treatment were proposed to reduce livestock and land pollutants.

Evaluation on Pollution Load Characteristics and Influence of Tributaries in the Hwangguji Stream (황구지천 유역의 오염부하 특성 및 지류 영향 평가)

  • Lim, Su-Jin;Lim, Byung-Ran;Lee, Han-Saem;Kang, Joo-Hyoung;Ahn, Tae-Ung;Shin, Hyun-Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.4
    • /
    • pp.249-262
    • /
    • 2021
  • This study investigated the pollution characteristics of the main pollution zone in the Hwangguji watershed and the influence of the tributary on the main stream. The characteristics of the main pollution zone, including, the water quality index (WQI), stream rating, load duration curve (LDC), delivery load density (DLD), and contribution of the tributary to the mainstream, were evaluated by time-series visual heatmap. The WQI of the mainstream of Hwangguji was lowered to the poor (IV) level from the inflow point of Suwon stream (SW) and the LDC excess rate in the T-P was higher than that of BOD5, especially for the wet season, suggesting that management of non-point source with T-P is preferred. The contribution (%) of the tributaries in the upstream section of Hwangguji watershed were BOD5 14.54%, TOC 15.67%, T-N 5.43%, and T-P 6.97%. In particular, the Suwon sewage treatment plant located in the mainstream showed a high contribution of BOD5 (64.40%) and T-P (53.54%), respectively, due to the high discharge rate (6.019 m3/sec). Meanwhile, Sammi and Gal stream have a large impact on the mainstream with high DLD and poor WQI. Thus, both streams were considered as pollution hot spots. These results provide useful basic data for preparing more effective water quality improvement and management plans in the watershed.