• Title/Summary/Keyword: Non-penetrating

Search Result 125, Processing Time 0.025 seconds

Electromagnetic Survey in Korea (한국의 전자탐사 현황)

  • Cho, Dong-Heng
    • Economic and Environmental Geology
    • /
    • v.39 no.4 s.179
    • /
    • pp.427-440
    • /
    • 2006
  • Electromagnetic(EM) survey has been in use for over a half century as a standard routine for, mineral exploration in many parts of the world. But EM survey work and serious research effort were initiated in Korea only as late as in early 1980s, largely inspired by four pioneers who did their graduate studies in the U.S.A. in 1970s. Nevertheless domestic achievements in the field of EM survey are remarkable in the last two decades: the field operations and related interpretational skills appear to have reached a global standard, even compared with the most advanced in other countries, virtually in a whole spectrum of the method which includes magneto-tellurics(MT), Controlled Source Audio-frequency Magneto-tellurics(CSAMT), geomagnetic sounding, small loop survey systems, Very Low Frequency(VLF), Ground Penetrating Radar(GPR), time domain surveys, and noise analysis. Besides mineral exploration, EM survey has been applied in Korea to hydrogeology, geotechnical engineering, non-destructive investigation of structures, unexplored ordnance(UXO) investigation, environmental monitoring, and archaeological investigation as well. Now that original contributions of several Korean geophysicists are found even in new frontiers such as high-frequency EM survey, investigation in time-domain EM field for buried metal objects and structures, and also modem data inversion scheme, it is duly hoped that they make some technical breakthrough to unravel still entangled knots of EM survey method in a forseeable future.

Application of Computed Radiography for Nondestructive Testing of Boiler Tube Weldments (보일러튜브 용접부 비파괴검사를 위한 컴퓨터화 방사선투과시험 적용 연구)

  • Park, S.K.;Ahn, Y.S.;Gil, D.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.95-102
    • /
    • 2009
  • A steam generator (boiler) in thermal power plants, consisting of more than 30,000 parts and components, can lead to the plant shutdown with damage to even the small part of the components; esp., like weld failures on boiler tubes. Consequently it is greatly demanded to improve the quality of the weld on the boiler tube for the stable operation of the power plants. Because of the feature of the welding, which is done past by melting the work pieces and adding a filler material that cools to become a strong coalescence, there is a great possibility that weld failures take place. As a result, it is regulated to make a non-destructive testing, like radiography test, to detect defects and flaws in the weld. The current film radiography test provides a lower image quality exceeding 2.0% of a basic quality level for a penetrameter, it is very likely to fail to detect micro defect. As a result, the prevention for the boiler tube failure has not been made effectively. In this study, computed radiography technology has been applied as a digital radiography test to the boiler tube weld, and Se-75 radiation source was used to improve the image quality, instead of Ir-192 source. As a result of this study, it is proven to save the time and cost for test and to enhance the quality level of penetrameter penetrating image, which enables to upgrade the quality of radiography test to the boiler tube weld.

  • PDF

Evaluation of Applicability of penetrating-type Nano-Coat for Preventing Deterioration of Concrete (침투형 Nano-Coat를 이용한 콘크리트 열화 방지 적용성 평가)

  • Lee, Jun Hee;Kim, Jo Soon;Sim, Yang Mo;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.7-15
    • /
    • 2017
  • PURPOSES : Infiltration of moisture, polluted material, and deicer into concrete, accompanied by freeze and thaw can cause significant deterioration of concrete pavement. In order to protect concrete from deterioration, it is necessary to prevent the infiltration of these concrete external materials. The moisture-repellent agent, which is a surface treatment and maintenance material added to concrete structures to render them water resistant, has advantages such as prevention of water infiltration and security against air permeation. Nano-coat, which is referred to as silicon hydride, is typically used as a moisture-repellent agent. Therefore, in this study, an attempt is made to use penetration-type Nano-coat as an alternative in order to evaluate its applicability through environmental resistance tests. METHODS : This study aimed to evaluate the applicability of penetration-type Nano-coat, which can provide water repellency to concrete, in concrete pavements, through various environmental resistance tests such as freezing and thawing resistance, chloride ion penetration resistance, and surface scaling resistance tests. The applicability of penetration-type Nano-coat was demonstrated based on the specification of KS F 2711, KS F 2456, and ASTM C 672. RESULTS :In the case of penetration-type Nano-coat applied on sound concrete, an increase in concrete durability was demonstrated by the negligible chloride ion penetrability and the absence of scaling, as revealed by visual observation of the surface, after 50 cycles of scaling resistance test. In addition, test result of the application of penetration-type Nano-coat on deteriorated concrete established that concrete surface pretreated by grinding provided improved durability than non-treated concrete. CONCLUSIONS :This study indicates that penetration-type Nano-coat is applicable as an effective alternative, to increase the durability of concrete structures. In addition, it was known that pretreatment of deteriorated concrete surface, such as grinding, is required to improve the long-term performance of concrete pavement.

five year experience of thoracic civilian injuries -481 cases- (최근 5년간의 흉부손상 경험 -481 예-)

  • Son, Gwang-Hyeon;Gu, Bon-Il;Kim, Tae-Yeong
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.421-428
    • /
    • 1986
  • From January 1981 through December 1985, 481 thoracic civilian injuries were reviewed in the Department of Thoracic Surgery, Paik Hospital in Seoul. Sixty two percent of the injuries were caused by traffic accident, 18% fall down, 15% blunt trauma, 2% crushing injury, 2% stab wound, and 0.4% gunshot wound. Peak incidence of the trauma victim was fourth and fifth decades revealing 22% and 27% respectively. Sex ratio was 3.5:1 with male predominance. Elapsed time before admission was less than one hour in 36% and one to six hour in 30%. The types of the injuries were as follows: Non-penetrating injuries were the most part of the wounded, 97.6%. Rib fracture was the most common lesion occupying 292 patient out of 481 [61%]. Of these 292 patients, 72% was multiple rib fracture. The incidence of hemothorax or hemopneumothorax was 19% [102 patients] [Table 4]. Most common associated condition was head injuries, 98 patients [14%]. Thoracoabdominal injuries were seen in 31 patients [0.6%]. Tube thoracostomy was the definitive measures in the 20% of the wounded. Open thoractomy was performed in 5%. Additional procedures for the associated condition were done in the 16% of the cases, for example, reduction of long bone fracture and trephination for the head injury. Among 481 wounded, fatal complication occurred in 13 patients [2.7%]. This paper has also compared two series of patients according to period; one from 1970 to 1980 and the present series [Table 8]. Conclusively, the fatal complications or trauma death may be reduced by the effort 1] rapid transport of the victim, 2] initial correction or resuscitative measures of the circulatory and ventilatory deficit 3] early decision of definitive thoracostomy or thoracotomy and 4] proper prioritizing for the care of the multiple critically injured patient.

  • PDF

GEOTECHNICAL ENVIRONMENT SURVEY (2) (고심도 지반환경 조사 - 비파괴 물리탐사의 적용 (2))

  • HoWoongShon;SeungHeeLee;HyungSooKim
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.4
    • /
    • pp.261-268
    • /
    • 2003
  • Lots of various utilities are buried under the surface. The effective management of underground utilities is becoming the very important subject for the harmonious administration of the city. Ground Penetrating Radar(GPR) survey including other various underground survey methods, is mainly used to detect the position and depth of buried underground utilities. However, GPR is not applicable, under the circumstances of shallow depth and places, where subsurface materials are inhomogeneous and are composed of clay, salt and gravels. The aim of this study is to overcome these limitations of GPR and other underground surveys. High-frequency electromagnetic (HFEM) method is developed for the non-destructive precise deep surveying of underground utilities. The method is applied in the site where current underground surveys are useless to detect the underground big pipes, because of poor geotechnical environment. As a result, HFEM survey was very successful in detecting the buried shallow and deep underground pipes and in obtaining the geotechnical information, although other underground surveys including GPR were not applicable. Therefore this method is a promising new technique in the lots of fields, such as underground surveying and archaeology.

  • PDF

Traumatic Pseudoaneurysm of the Superficial Temporal Artery: Two Cases Report (수상 후 천측두동맥에 발생한 가성동맥류의 치료 2례)

  • Kim, Youn Hwan;Hwang, Won Jung;Song, Soon-Young
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.115-118
    • /
    • 2007
  • Purpose: It is even less common traumatic pseudoaneurysm of the superficial temporal artery and rare with fewer than 200 cases reported in the recent literature. Most common causes of traumatic pseudoaneurysm is sequelae of blunt, penetrating, or iatrogenic surgical trauma. The diagnosis is based on physical findings and can be confirmed by duplex ultrasonogram, computed tomography, and angiography. Surgical resection, percutaneous embolization and conservative treatment have all been used to treat pseudoaneurysm. However recently, non invasive technique like percutaneous thrombin injection under ultrasonographic guidance has been done rather than surgical ligation. In this report, we proposed the several treatment options such as conservative treatment, thrombin injection, and surgical ligation according to the multifarous conditions of pseudoaneurysm, patient, and causes. Methods: We describe two cases of traumatic pseudoaneurysm of superficial temporal artery in which CT angiography was effective in diagnosis and characterization. One is chronic pseudoaneurysm after traffic accident, which is fusiform shape and small size. Since the patient prefered it, we proposed percutaneous thrombin injection first. But we recognize that this method failed, we used surgical ligation according to information of CT angiographic findings. The other is acute pseudoaneurysm after blunt trauma, which is large size accompanying large hematoma. So we proposed compressive dressing and aspiration of hematoma. Results: Two cases were well treated with no recurrence or complication. Conclusion: In conclusion, when selecting a treatment options, followings should be considered: pseudoaneurysm in CT angiography, chronicity, cause, and patient's preference.

A Study on Numerical Analysis for GPR Signal Characterization of Tunnel Lining Cavities (터널 라이닝 공동에 대한 GPR 신호 특성 분석을 위한 수치해석 연구)

  • Go, Gyu-Hyun;Lee, Sung Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.10
    • /
    • pp.65-76
    • /
    • 2021
  • There is a possibility of cavities occurring inside and behind the lining of an aged tunnel structure. In most cases, it is not easy to check the cavity because it exists in a place where visual inspection is impossible. Recently, attempts have been made to evaluate the condition of the tunnel lining and the backfill materials using non-destructive tests such as Ground Penetrating Radar, and various related model tests and numerical analysis studies have been conducted. In this study, the GPR signal characteristics for tunnel lining model testing were analyzed using gprMax software, which was compared with model test results. The numerical model applied to the model test reasonably simulated the electromagnetic wave signal according to the change of the material such as tunnel lining and internal cavity. Using the verified GPR model, B-scan data for the development of the GPR signal analysis technique were obtained, which can evaluate the thickness of the tunnel lining, the presence of the cavity, the effect of the waterproof membrane, and the frequency band.

Clinical Characteristics of Trauma-Related Chronic Osteomyelitis in 3 Wild Raccoon Dogs (Nyctereutes procyonoides)

  • Ha, Minjong;Ahmed, Sohail;Lee, Do Na;Han, Janghee;Yoon, Junghee;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.131-137
    • /
    • 2022
  • Osteomyelitis typically occurs because of the direct inoculation of bacteria or fungi after penetrating trauma or surgical contamination or, by extension, from soft tissue infection. Osteomyelitis is rarely reported in wildlife animals, though severe chronic osteomyelitis cases do exist in wildlife owing to the scarcity of medical support in the wild environment. This report describes three cases of chronic osteomyelitis in wild raccoon dogs related to trauma. The typical symptoms of three reported cases were ataxia, stiffness, muscle atrophy, and lethargy. All three cases were relevant to traumatic or severe external injury, and skin infestation caused by ectoparasites was apparent on an ocular inspection. In the radiographic examination, diffuse sites of osteolytic lesions and remarkable periosteal responses were demonstrated around the injured limb in all three cases. Apparent neutrophilia with a left shift, lymphocytosis, and monocytosis in hematological examinations generally indicated chronic infection as shown in case 1 and 3. Treatment was attempted with broad-spectrum antibiotics and non-steroidal anti-inflammatory drugs, such as amoxicillin/clavulanic acid, enrofloxacin, clindamycin, and meloxicam. These treatment options helped improve the overall prognosis of chronic osteomyelitis, but the outcomes did not meet the treatment goal entirely. Osteomyelitis can be extremely challenging to treat, particularly in wild animals, because of their distinctive traits, such as masking phenomenon and uncontrolled exposure to ectoparasites. Earlier diagnosis with a radiographic examination, hematological examinations, and careful patient monitoring, followed by prolonged antibiotic therapy and restricted exercise, are the key factors leading to a better prognosis.

Comparative Compressional Behavior of Zeolite-W in Different Pressure-transmitting Media (제올라이트-W의 압력전달매개체에 따른 체적탄성률 비교 연구)

  • Seoung, Donghoon;Kim, Hyeonsu;Kim, Pyosang;Lee, Yongmoon
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.3
    • /
    • pp.169-176
    • /
    • 2021
  • This study aimed to fundamentally understand structural changes of zeolite under pressure and in the presence of different pressure-transmitting media (PTM) for application studies such as immobilization of heavy metal cation or CO2 storage using pressure. High-pressure X-ray powder diffraction study was conducted on the zeolite-W (K6.4Al6.5Si25.8O64× 15.3H2O, K-MER) to understand linear compressibility and the bulk moduli in different PTM conditions. Zeolite-w is a synthetic material having the same framework as natural zeolite merlinoite ((K, Ca0.5, Ba0.5, Na)10 Al10Si22O64× 22H2O). The space group of the sample was identified as I4/mmm belonging to the tetragonal crystal system. Water, carbon dioxide, and silicone-oil were used as pressure-transmitting media. The mixture of sample and each PTM was mounted in a diamond anvil cell (DAC) and then pressurized up to 3 GPa with an increment of ca. 0.5 GPa. Pressure-induced changes of powder diffraction patterns were measured using a synchrotron X-ray light source. Lattice constants, and bulk moduli were calculated using the Le-Bail method and the Birch-Murnaghan equation. In all PTM conditions, linear compressibility of c-axis (𝛽c) was 0.006(1) GPa-1 or 0.007(1) GPa-1. On the other hand, the linear compressibility of a(b)-axis (𝛽a) was 0.013(1) GPa-1 in silicone-oil run, which is twice more compressible than the a(b)-axis in water and carbon dioxide runs, 𝛽a = 0.006(1) GPa-1. The bulk moduli were measured as 50(3) GPa, 52(3) GPa, and 29(2) GPa in water, carbon dioxide, and silicone-oil run, respectively. The orthorhombicities of ac-plane in the water, and carbon dioxide runs were comparatively constant, near 0.350~0.353, whereas the value decreased abruptly in the silicone-oil run following formula, y = -0.005(1)x + 0.351(1) by non-penetrating pressure fluid condition.

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.