• Title/Summary/Keyword: Non-invasive measurement

Search Result 185, Processing Time 0.025 seconds

Non-invasive quantification methods for glucose monitoring (포도당 모니터링을 위한 비침습적 정량화 방법)

  • Young Ho, Kim;Yeong-Seo, Park;Byeong Uk, Park;inkwon, Yoon;Hee-Jae, Jeon
    • Journal of Industrial Technology
    • /
    • v.42 no.1
    • /
    • pp.13-18
    • /
    • 2022
  • Diabetes mellitus is an abnormally high glucose level in the bloodstream. Several pharmaceuticals are administered to diabetic patients to control their glucose levels. Early diagnosis and proper glycemic management are essential in this situation to prevent further progression and complications. Biosensor-based detection has progressed and shown potential in portable and inexpensive daily assessment of glucose levels because of its simplicity, low cost, and convenient operation without sophisticated instrumentation. This review discusses various systemic aspects of non-invasive glucose monitoring, including materials for monitoring and managing diabetes.

Assessment methods for evaluating the whitening effect of cosmetics on human skin

  • Kim, Youn-Soo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.28 no.3
    • /
    • pp.63-90
    • /
    • 2002
  • Quantitative measurement of melanin is the best method to evaluate whitening effect of cosmetics on human skin. However, non-invasive method to quantify human skin melanin with high precision has not been established. Whitening effect of cosmetics on the skin results in lightening of skin color. Therefore, it is reasonable to measure skin color in a reproducible manner for the assessment of whitening effect. Several Instruments or methods, such as colorimeter, mexameter, and visual assessments by experts , have been used for this purpose. In this lecture I will review the details of various assessment methods for the evaluation of whitening effect and discuss the pros and cons of each method. Then I will present briefly the results of clinical trial. Finally I will introduce new non-invasive modalities to quantify melanocytes.

Blood Pressure Measurement using the Modified Step-wise Deflation Method (개선된 계단 배기 방법을 이용한 혈압 측정)

  • Oh, Hong-Sic;Lee, Jong-Shill;Chee, Young-Joon;Kim, In-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.351-358
    • /
    • 2010
  • In the automatic non-invasive blood pressure measurement device, the oscillometric method iswidely used. In the oscillometric method, the step-wise deflation has the advantage of the robustness for the motion artifacts than the linear deflation method. But it has the disadvantage of its longer measurement time because we need to detect two or more pulses in a certain cuff pressure step. In this study, we suggest the modified step-wise deflation method to overcome this limitation while maintaining the general concept of step-wise deflation. Using one valid pulse in each step and the deflating valve control during the diastolic period, the measurement time could be reduced. In order to verify the accuracy of the proposed algorithm, we compared the blood pressure values from the suggested method and the blood pressure values from the conventional auscultation method. The mean and standard deviation were -0.50${\pm}$5.3mmHg and 2.08${\pm}$4.75mmHg, for systolic and diastolic blood pressure respectively. The measurement time can be reduced up to the half of conventional step-wise deflation method.

Research on Subcutaneous Pulse Shape Measurement by Near-infrared Moiré Technique

  • Chen, Ying-Yun;Liu, Zhizhen;Du, Jian;Chang, Rong-Seng
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • A pulse is generated when the heart pumps blood into the arterial system. The heart pumps blood only when it contracts, not when it relaxes; therefore, blood enters the arterial system in a cyclical form. Artery beating is visible in some parts of the body surface, such as the radial artery of the wrist. This paper mainly uses the feature in which near-infrared spectroscopy penetrates skin to construct a non-invasive measurement system that can measure small vibration in the subcutaneous tissue of the human body, and then uses it for the pulse measurement. This measurement system uses the optical moir$\acute{e}$ principle, together with the fringe displacement made by small vibration in the subcutaneous tissue, and an image analysis program to calculate the height variation from small vibrations in the subcutaneous tissue. It completes a measurement system that records height variation with time, and that together with a fast Fourier transform (FFT) program, they can convert the pulse waveform generated by vibration (time-amplitude) to heartbeat frequency (frequency-amplitude). This is a new and non-invasive medical assistance system for measuring the pulse of the human body, with the advantages of being simple, fast, safe and objective.

1/f-LIKE FREQUENCY FLUCTUATION IN FRONTAL ALPHA WAVE AS AN INDICATOR OF EMOTION

  • Yoshida, Tomoyuki
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.99-103
    • /
    • 2000
  • There are two approaches in the study of emotion in the physiological psychology. The first is to clarify the brain mechanism of emotion, and the second is to evaluate objectively emotions using physiological responses along with our feeling experience. The method presented here belongs to the second one. Our method is based on the "level-crossing point detection" method. which involves the analysis of frequency fluctuations of EEG and is characterized by estimation of emotionality using coefficients of slopes in the log-power spectra of frequency fluctuation in alpha waves on both the left and right frontal lobe. In this paper we introduce a new theory of estimation on an individual's emotional state by using our non-invasive and easy measurement apparatus.

  • PDF

Blood Glucose Measurement Principles of Non-invasive Blood Glucose Meter: Focused on the Detection Methods of Blood Glucose (무채혈 혈당 측정기의 혈당 측정 원리: 혈당 검출방법 중심으로)

  • Ahn, Wonsik;Kim, Jin-Tae
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.114-127
    • /
    • 2012
  • Recent technical advancement allows noninvasive measurement of blood glucose. In this literature, we reviewed various noninvasive techniques for measuring glucose concentration. Optical or electrical methods have been investigated. Optical techniques include near-infrared spectroscopy, Raman spectroscopy, optical coherence technique, polarization, fluorescence, occlusion spectroscopy, and photoacoustic spectroscopy. Electrical methods include reverse iontophoresis, impedance spectroscopy, and electromagnetic sensing. Ultrasound, detection from breath, or fluid harvesting technique can be used to measure blood glucose level. Combination of various methods is also promising. Although there are many interesting and promising technologies and devices, there need further researches until a commercially available non-invasive glucometer is popular.

In Vivo Doppler-Based Measurement of Bending Vibration Velocity in Liver Vibrated by Lo7v Frequency Signal (초음파 Doppler법에 의한 비침투적인 생체조직의 진동속도 계측)

  • 박무훈;장윤석
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.407-412
    • /
    • 1997
  • In this paper, we present a new method to diagnose the characteristics of the soft tissue, especially a liver. In order to diagnose the characteristics of a liver, it is necessary to evaluate the propagation delay time and propagation velocity of bending vibration In a liver. For this purpose, we measure the propagation velocity of bending vibration in a liver for low frequency forced vibration using a standard ultrasonic Doppler diagnosis equipment. We have carried out preliminary experiments by using an ultrasonic probe of 3.5MHz and obtained some results. This new measurement method developed here can be applied to new research and medical fields for acoustic non-invasive diagnosis of soft tissue.

  • PDF

A Study on Cerebral Blood Flow Enhancement Device Using Blood Oxygen Level Sensor (Blood Oxygen Level Sensor를 이용한 대뇌혈류증가 장치에 관한 연구)

  • Lim, Jung-Hyun;Joh, In-Hee;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.188-192
    • /
    • 2018
  • Surgery to increase cerebral blood flow is one of the treatment methods of cerebral infarction. However, invasive methods, such as surgery, may result in postoperative complications or side effects. In order to supplement this invasive method, non-invasive devices have been introduced that use human blood pressure to pressurize the extremities to increase cerebral blood flow. However, the problem of poor speed and accuracy was raised. In this paper, the perfusion index of each arm was measured by applying pressure to both arms using Blood Oxygen Level Sensor to improve the accuracy of measurement and measurement time. The pressure applied to the arm by 75% of the moment when it falls to the leg and the pressure calculated by using the pressure value obtained from the arm. Like the existing blood pressure measuring cerebral blood flow increasing device, the blood flow can be increased by more than 20% and the measurement time can be shortened, so that it can be selectively used for the patient with cerebral infarction.

  • PDF

Measurement of the Metabolism of Energy Substrates in Single IVF-derived Bovine Embryos (소 체외수정란에 있어서 Non-invasive 방법에 의한 기질 대사량의 측정)

  • ;;S. Sugawara
    • Korean Journal of Animal Reproduction
    • /
    • v.19 no.3
    • /
    • pp.161-169
    • /
    • 1995
  • To investigate the metabolism of various substrates in preimplantation bovine embryos, uptake of glucose and pyruvate, and lactate production were measured in single IVF-derived bovine embryos by a non-invasive method. When the embryos were incubated for 5 h in culture medium supplemented with 1 mM glucose and 0.4mM pyruvate as substrates at each developmental stage, glucose uptake was increased with more advanced developmental stages while pyruvate uptake was decreased. Total lactate producton of 2-cell embryos was significantly higher than that of blastocysts (p<0.05). Both of glucose uptake and lactate production in normal morulae produced in vitro was significantly high compared to the degenerated embryos(p<0.05). The results obtained in the study suggest that pyruvate as an exogenous substrate may be support in bovine embryos until 8-cell stage, whereas glucose may be effective as an energy source after morula stage. In addition, it was proven thatlactate was not effective as an energy source in preimplantation development of IVF-derived bovine embryos.

  • PDF