• Title/Summary/Keyword: Non-invasive blood pressure(NIBP)

Search Result 3, Processing Time 0.016 seconds

A Simulator for the Validation of Non-invasive Blood Pressure (NIBP) Monitoring Devices (자동혈압계 성능평가를 위한 인체혈압 시뮬레이터 개발)

  • Doh, Il;Lim, Hyun Kyoon;Ahn, Bongyoung;Chee, Youngjoon;Lee, Jongshill;OH, Jae Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.111-115
    • /
    • 2017
  • Blood pressure is one of the important vital signs for monitoring the medical condition of a patient. Automated NIBP(non-invasive blood pressure) monitoring devices calculate systolic and diastolic blood pressures from the oscillation in cuff pressure caused by a pulsation of an artery. To validate the NIBP devices, we developed a simulator to supply the oscillometric waveforms obtained from human subjects. The simulator provided pressure pulses to device-under-test and device readings were compared to the auscultatory references. Fully automated simulation system including OCR(optical character recognition) were developed and used for NIBP monitoring devices. The validation results using the simulator agreed well with previous clinical validation. More validation studies using the standardized oscillometric waveforms would be required for the replacement of clinical trials to validate a new automated NIBP monitoring device.

Design of a Portable Patient Monitor (휴대용 환자 감시장치의 설계)

  • Kim, E.S.;Lee, E.P.;Gil, Mun-Jong;Lee, K.J.;Yoon, H.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.407-410
    • /
    • 1997
  • In this paper, we have designed a portable patient monitor that monitors both ECG and NIBP(Non-Invasive Blood Pressure) for a patient who is bring moved around inside a hospital. System hardware consists of the one-chip microcomputer(80c251), A/D converter, ROM, RAM, LCD diplsy, two channel ECG module and NIBP module. NIBP module was calibrated to the values found in NIBP analyzer. ECG module detects QRS complex and compute heart rate. NIBP module measures the blood pressure by oscilometric method.

  • PDF

Remote Patient Monitoring through the Internet (인터넷을 통한 원격환자 모니터링)

  • 박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.377-383
    • /
    • 2001
  • In this paper, we present an intensive patient monitoring service through the Internet, which enables medical doctors to watch their patients in a remote site, to monitor their vital signs and to give them some advices for first-aid treatment. The service consists of three service objects: Monitoring Information Service(MIS), Vital Sign Monitoring Service(VSMS) and Multimedia Consulting (MCS). Through the MIS, medical doctors can get information about the patients currently under monitoring, including their names, ages, genders, symptoms, current main complaints and current locations. The VSMS enables medical doctors to monitor in real-time patients' vital signs such as electrocardiogram (ECG), respiration, temperature, blood oxygen saturation (SpO$_{2}$), invasive blood pressure (IBP), and non-invasive blood pressure (NIBP). It also generates alarms when the patients are likely to be in a critical situation. The MCS provides a real-time multimedia desktop conferencing facility for watching patients and instructing attendants to administer some first-aid treatment. We carried out some experiments according to two different scenarios. The intensive patient monitoring service was functioning well in a 100Base-T Ethernet LAN environment.

  • PDF