• Title/Summary/Keyword: Non-destructive X-ray analysis

Search Result 54, Processing Time 0.02 seconds

Non-destructive Analysis of Material Characteristics and Provenance of Granite Monuments: The Cases of Stupa for National Preceptor Wongong at Geodonsa Temple and Five-story Pagoda at Cheonsusa Temple (비파괴 분석을 이용한 화강암류 석조 문화재의 부재특성과 산지추정: 거돈사 원공국사 승묘탑과 천수사 오층석탑을 중심으로)

  • Kim, Yonghwi;Choi, Seongyu;Seo, Jieun;Kang, Jeonggeuk;Lee, Jonghyun;Jo, Yeontae
    • Conservation Science in Museum
    • /
    • v.19
    • /
    • pp.19-40
    • /
    • 2018
  • Most stone monuments in Korea are made from the granitoids found extensively throughout the nation. To identify the provenance of the stone materials, this study carried out comprehensive analyses of the occurrence, physical properties, mineralogy, and chemical composition of Stupa for National Preceptor Wongong at Geodonsa Temple and Five-story Pagoda at Cheonsusa Temple, both located in the Gangwon region. Their features were compared with those of granite from Wonju City near the sites of the two monuments. Stupa for National Preceptor Wongong is composed purely of two-mica granite, whereas Five-story Pagoda was made from both two-mica and biotite granites. The occurrence and magnetic susceptibility of the two granite monuments generally coincide with those of granite from Wonju. When selecting materials for the restoration of stone monuments, it is deemed necessary to carry out a field survey on granite in areas adjacent to the locations of the stone monuments subject to restoration.

Evaluation of Bone Change by Digital Subtraction Radiography after Implantation of Tooth Ash-plaster Mixture (치아회분과 석고혼합제제 매식후 Digital Subtraction Radiography에 의한 골량 변화의 평가)

  • Kim Jae-Duk;Kim Kwang-Won;Cho Yaung-Gon;Kim Dong-Kie;Choi Eui-Hwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.423-433
    • /
    • 1999
  • Purpose : To assess the methods for the clinical evaluation of the longitudinal bone changes after implantation of tooth ash-plaster mixture into the defect area of human jaws. Materials and methods : Tooth ash-plaster mixtures were implanted into the defects of 8 human jaws. 48 intraoral radiograms taken with copper step wedge as reference at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture were used. X-ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner were digitized and analyzed by NIH image program. Cu­equivalent values were measured at the implanted sites from the periodic digital images. Analysis was performed by the bidirectional subtraction with color enhancement and the surface plot of resliced contiguous image. The obtained results by the two methods were compared with Cu­equivalent value changes. Results : The average determination coefficient of Cu-equivalent equations was 0.9988 and the coefficient of variation of measured Cu values ranged from 0.08~0.10. The coefficient of variation of Cu-equivalent values measured at the areas of the mixture and the bone by the conversion equation ranged from 0.06 ~0.09. The analyzed results by the bidirectional subtraction with color enhancement were coincident with the changes of Cu-equivalent values. The surface plot of the resliced contiguous image showed the three dimensional view of the longitudinal bone changes on one image and also coincident with Cu-equivalent value changes after implantation. Conclusion : The bidirectional subtraction with color enhancement and the surface plot of the resliced contiguous image was very effective and reasonable to analyze clinically and qualitatively the longitudinal bone change. These methods are expected to be applicable to the non-destructive test in other fields.

  • PDF

Rapid Screening of Naturally Occurring Radioactive Nuclides (238U, 232Th) in Raw Materials and By-Products Samples Using XRF

  • Park, Ji-Young;Lim, Jong-Myoung;Ji, Young-Yong;Lim, Chung-Sup;Jang, Byung-Uck;Chung, Kun Ho;Lee, Wanno;Kang, Mun-Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.359-367
    • /
    • 2016
  • Background: As new legislation has come into force implementing radiation safety management for the use of naturally occurring radioactive materials (NORM), it is necessary to establish a rapid and accurate measurement technique. Measurement of $^{238}U$ and $^{232}Th$ using conventional methods encounter the most significant difficulties for pretreatment (e.g., purification, speciation, and dilution/enrichment) or require time-consuming processes. Therefore, in this study, the applicability of ED-XRF as a non-destructive and rapid screening method was validated for raw materials and by-product samples. Materials and Methods: A series of experiments was conducted to test the applicability for rapid screening of XRF measurement to determine activity of $^{238}U$ and $^{232}Th$ based on certified reference materials (e.g., soil, rock, phosphorus rock, bauxite, zircon, and coal ash) and NORM samples commercially used in Korea. Statistical methods were used to compare the analytical results of ED-XRF to those of certified values of certified reference materials (CRM) and inductively coupled plasma mass spectrometry (ICP-MS). Results and Discussion: Results of the XRF measurement for $^{238}U$ and $^{232}Th$ showed under 20% relative error and standard deviation. The results of the U-test were statistically significant except for the case of U in coal fly ash samples. In addition, analytical results of $^{238}U$ and $^{232}Th$ in the raw material and by-product samples using XRF and the analytical results of those using ICP-MS ($R^2{\geq}0.95$) were consistent with each other. Thus, the analytical results rapidly derived using ED-XRF were fairly reliable. Conclusion: Based on the validation results, it can be concluded that the ED-XRF analysis may be applied to rapid screening of radioactivities ($^{238}U$ and $^{232}Th$) in NORM samples.

Non-Destructive Material Analysis of Whetstones Discovered in Grain Transport Ship of the Early Joseon Period (조선 초기 조운선(마도4호선)에서 출수된 숫돌의 비파괴 재질 분석 연구)

  • Dal-Yong Kong;Jae Hwan Kim;Eun Young Park;Yong Cheol Cho;Ki Hong Yang
    • Economic and Environmental Geology
    • /
    • v.56 no.6
    • /
    • pp.661-674
    • /
    • 2023
  • From the seafloor of Taean, Chungcheongnamdo Province, a ship of the Joseon Dynasty was discovered for the first time in the history of underwater excavations in Korea in 2014 and was named Mado Shipwreck No. 4. A total of 27 unused whetstones loaded as tribute were discovered on the hull of Mado No. 4, which revealed that Mado Shipwreck No. 4 was a Grain transport ship that sank while carrying tribute from Naju to Hanyang between 1417 and 1425 (King Taejong to King Sejong). All of the 27 whetstones are in the shape of narrow and long sticks. The average values of length, width, thickness, and weight are 161.5 mm, 36.1 mm, 22.7 mm, and 253.2 g, respectively. The result of X-ray diffraction analysis shows that the constituent minerals are quartz, alkali feldspar, and plagioclase, which is similar to that of the high-resolution digital stereomicroscope analysis. The average porosity of Mado-2672 and 2673 is 2.69% and 1.78%, respectively, and the average surface hardness is 807.2HLD and 834.5HLD, respectively. It is interpreted that if the porosity increases beyond a certain level, it affects the decrease in surface hardness. All of these are made of feldspathic sandstones with an average SiO2 content of 74.51% and were confirmed to be suitable as grindstones. They are all medium whetstones when classified based on the SiO2 content. These whetstones are small in size and weight and are convenient to carry, so they are presumed to be a type of non-stationary whetstone, and are estimated to have been mainly used in the fields such as weapon polishing and craft production during the Joseon Dynasty.