• Title/Summary/Keyword: Non-destructive Analysis

Search Result 561, Processing Time 0.037 seconds

A Study on Non Destructive Evaluation of the Steam Turbine L-0 Blades

  • Mizanur, Rahman Md.;Rezk, Osama;Ouma, Victor Otieno;Vaysidin, Saidov;Gomaa, M. Abdullatif;Jung, JaeCheon;Lee, YongKwan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.12 no.1
    • /
    • pp.59-71
    • /
    • 2016
  • The Nuclear and Fossil Steam Turbines record a considerable number of failures annually. Some of these failures reported are as result of blade failure. The failure of the L-0 blade in a Steam Turbine is one of the most reported blade failure in Nuclear and Fossil steam turbines. This paper seeks to identify the best Non Destructive Evaluation (NDE) method or methods to be used in the steam turbine L-0 blades inspection process. The development of systems engineering processes presents an opportunity to apply NDE inspection to the L-0 blades. This process apply computer modelling of the L-0 using ANSYS and by simulating the stresses experienced by the L-0 blade during operation it is possible to identify the most susceptible areas for crack formation and growth. The results from these models compared to industry data for validation. The analysis of these results used to predict the most probable failure location and failure modes. Therefore NDE inspection can be applied to these areas with greater degree of accuracy. This would be beneficial in the increasing the accuracy in the detection of cracks and hence save inspection time and the overall inspection cost. Furthermore, not only the location for crack formation and NDE inspection determined but also best the NDE inspection technique/techniques to be applied appropriately on the L-0 blade are prescribed.

Corrosion Level Measurement Technique for RC Reinforcement Using Non-Destructive Test Methods (비파괴기법을 이용한 철근 콘크리트 벽체 철근의 부식률 예측기법)

  • Roh, Young-Sook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.24-31
    • /
    • 2011
  • In order to measure corrosion level of reinforcement rebar in RC structures, non-destructive test methods which are concrete surface current density method and infrared thermographic technique were employed to measure corrosion levels. Experimental test parameters were various levels of corrosion states(0, 1, 3, 5, 7% of weight loss) and concrete cover depth(30 mm, 40 mm) and two different reinforcing rebar arrangements. The larger amount of concrete surface current density, the higher corrosion level in reinforcement rebar. The laboratory conditions which are ambient temperature and humidity have negligible effect on the infrared thermographical data. After analysis of current density and temperature distribution from concrete surface, corrosion level of reinforcement rebar embedded in concrete can be measured qualitatively based on the amount of electric current and heat flux.

Piezoelectric Transducer for Ultrasonic Flaw Detector with High Performance (고성능 초음파 결함탐상기를 위한 압전변환기)

  • Jung, Jun Hwan;Jun, Ho Ik;Kim, Hyun-Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1645-1652
    • /
    • 2013
  • In this paper, a new piezoelectric transducer for high performance ultrasonic flaw detector used in non-destructive test (NDT) is implemented. Here, the goals for some major characteristics such as piezoelectric strain constant and electro-mechanical coupling factor are fixed in advanced. Then, the parameters obtained by finite element analysis (FEA) are exploited to design and implement the piezoelectric transducer. As a result of experiments using manufactured samples, it is proved that the new PZT ceramics satisfy the goals very well. It has much improved impedance characteristic at the resonant frequency and generation of ultrasonic signals. In addition, ultrasonic flaw detector with the new transducer provides increased flaw detecting gain than the conventional one. Thus, it is considered that the new flaw detector contributes significantly to improve reliability of the NDT.

The Evaluation and Fabrication of Radiation Phosphor Screen for Non-destructive Testing using the Special Room Temperature Gel-printing Method (상온 겔프린팅 기법을 이용한 비파괴 검사용 방사선 증감지 제작 및 평가)

  • Lee, Jun Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.391-396
    • /
    • 2020
  • In this study, we developed a phosphor film screen that can be applied to radiographs during non-destructive testing using Gd2O2S:Tb phosphor compounds. The image uniformity of the fabricated phosphor screen film was analyzed by FE-SEM, RMS and RDS analysis. In addition, the tensile strength, elongation, and modulus of elasticity of the Gd2O2S:Tb phosphor screen were evaluated by measuring the stress-strain characteristic curve. As a result, it was evaluated that the RSD value had an excellent image uniformity within 10% of the evaluation criteria. In addition, as a result of evaluation of physical properties, the tensile strength was 1.1760 N/㎟, the tensile strength at break was 1.1515 N/㎟. These results suggest that the Gd2O2S:Tb phosphor screen fabricated using the room temperature gel-printing method could be applied to digital radiography detectors for radiography.

Study of Material Features of Baekje Gilt-bronze Crowns (비파괴 분석법에 의한 백제 금동관 재질 특성 연구)

  • Kim, Seonggon
    • Conservation Science in Museum
    • /
    • v.23
    • /
    • pp.91-108
    • /
    • 2020
  • This study conducted non-destructive analyses of the material features of seven gilt-bronze crowns of Baekje Kingdom that were excavated in the Cheonan, Gongju, Seosan, Iksan, Naju, and Hapcheon areas. A typical Baekje gilt-bronze crown has a conical inner crown and an outer crown embellished with vertical ornaments on the front and the back, a tube topped with a hemispherical ornament, and other ornamentation. Diverse designs (e.g., dragon, bonghwang, flowers, and plants) were applied using a range of techniques, including repoussé, chasing, openwork, and engraving. Formal features differ among the crowns according to their period of production and site of excavation. The substrate metal of the crowns is either pure copper or mixed copper with a small amount of lead. The crowns were amalgam-plated on the surface with pure gold or gold with a small amount of silver. The crown from Okjeon Tomb No. 23 in Hapcheon in the ancient Gaya region has a high silver content, which appears to be a regional feature. In addition, this crown from Okjeon Tomb No. 23, which can be categorized as Baekje-style gilt-bronze crown, seems to be plated at most three times, while the gilt-bronze crowns found within Baekje Kingdom territory were plated once or twice.

Application of Chlorophyll Fluorescence Imaging Technique to Estimate Fresh Weight in Kiwifruit (엽록소 형광이미징 기술을 이용한 키위과일의 생체중 예측)

  • Lee, Mi Kyung;Yoo, Sung Yung;Kim, Tae Wan;Ku, Hyun-Hwoi
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.2
    • /
    • pp.138-141
    • /
    • 2020
  • BACKGROUND: Fresh weight is one of the major quality measurement factors in determining the quality of fresh fruits. A practical method has been developed for rapid and non-destructive measurement using the Chlorophyll Fluorescence Image (CFI) technique to estimate changes in fresh weight of post-harvest products. METHODS AND RESULTS: Kiwifruit (Actinidia deliciosa) was used and measured for the fresh weight and CFI under different temperature conditions at 0, 10, and 20℃, from 0 to 21 days after storage (DAS). We observed the fresh weight of kiwifruit and measured the surface image for determining Fv/Fm value in terms of maximum quantum yield on each day. To estimate freshness of kiwifruit we applied linear regression between the measured fruit weights and Fv/Fm values. Results showed that fruit weights were reduced by 4% at 0℃, 6% at 10℃, and 14% at 20℃ for 21 days, respectively. And also, the value of Fv/Fm was shown as decreasing trend at all temperature conditions, especially at 20 ℃. Fv/Fm values showed highly significant correlation (R2>0.9) with fresh weight of kiwifruit at all different storage temperatures. CONCLUSION: Thus, CFI technique can be useful to estimate the fresh weight of kiwifruit.

Rapid Quality Evaluation of Dried Red Pepper by Near-infrared Spectroscopy (근적외 분광분석법에 의한 건조고추의 품질측정)

  • Cho, Rae-Kwang;Hong, Jin-Hwan;Kim, Hyun-Koo;Park, Moo-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.675-680
    • /
    • 1990
  • A near-infrared reflectance spectroscopic(NIRS) method which has been recently developed for a non-destructive method for measuring ingredients in foods and agricultural products especially was evaluated for the determination of capsanthin, total sugar, capsaicin and moisture contents in Korean domestic red peppers. A multiple linear regression analysis with the data obtained by standard-laboratory methods(capsaicin by GC, capsanthin by Colorimetry, total sugar by HPLC and moisture by Vacuum drying method) and NIRS method was carried out to make a calibration. The accuracy of the NIRS method was found to be adequate when the standard-laboratory values for a set of sample that were not included in the calibration, were compared. It is concluded that the NIRS method is suitable for the determination of total sugar and capsanthin.

  • PDF

Development of the Impulse Response Measurement System for Non-destructive Test of Slab Structure (판상 구조물 비파괴검사를 위한 충격응답시험기의 개발)

  • Chung, Hojoon;Lee, Heuisoon;Oh, Seokhoon;Song, Sung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.1
    • /
    • pp.45-52
    • /
    • 2013
  • We developed a Impulse Response Measurement System, including hardware system and data analysis software, for non-destructive test of slab structure. And, we carried out impulse response measurements on the pavement to test performance of the system. In the field test, the developed system measured impulse response stably and showed parameters immediately. Test results showed that dynamic stiffness and average mobility varies significantly depending on the characteristics of the pavement materials. Some data showed anomalous values those reflect variations in pavement itself or subsurface ground. Developed system gives informations of conditions of slab structure easily and quickly. So, 2-D monitoring with the system will be helpful in maintaining various slab structures.

Non-destructive Analysis of Compost by Near Infrared Spectroscopy (근적외선 분광법을 이용한 퇴비의 비파괴 분석)

  • Nam, Jae Jak;Lee, Sang Hak
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.5
    • /
    • pp.410-414
    • /
    • 2000
  • The feasibility of near infrared spectroscopy (NIRS) for the evaluation of the compost pro-duced by composting swine excreta has been investigated. The analytes determined were total nitrogen, total phosphorus, organic matter,total carbon,moisture, Cu, $K_2O$ and $Na_2O$. The ranges of concentration of the cal-ibration samples obtained by the conventional chemical method for each component were 1.30-2.75%, 1.45-4.86%, 7.36-81.5%, 23.0-41.1%, 4.2 the coefficient of variation was 4.38, 5.5, 3.2, 1.5, 10.9, 10.6 and 11.9% for total nitrogen, total phosphorus, organic matter, total carbon, moisture, Cu, $K_2O$ and $Na_2O$,respectively. The overall results showed that NlRS can be used for a non-destructive and rapid determination of the analytes to evaluate the quality of compost samples.

  • PDF

Estimation of Shape of Voids behind Concrete Tunnel Linings Using Radar of Three Dipole Antenna Type (3 다이폴 안테나 방식 레이더에 의한 콘크리트 터널 라이닝 배면 공동의 형상 추정)

  • Park Seok-Kyun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.2 s.86
    • /
    • pp.221-227
    • /
    • 2005
  • The presence of voids behind tunnel linings is very likely to result in settlement or structural collapse. One proposed method of detecting such voids by non-destructive method is radar. More than effectively judging the existence of voids behind tunnel linings, this study aims to develop the analysis algorithm of radar capable of estimation of the shape of specific voids. To acquire directional information and estimate the shape of three-dimensional voids, the radar of three-dipole antenna type is used. As a foundation to this ongoing research, an investigation of microwave polarization methods using three-dipole antenna carried out with various void orientations and void geometries. As a result, it is clarified that the response of four microwave polarization modes depends on void geometry and thus there is a possibility of identifying the geometry and orientation (the shape) of specific voids using radar of three-dipole antenna type.