• 제목/요약/키워드: Non-clinical fields

검색결과 61건 처리시간 0.026초

팬텀투과계수와 유효조사면 개념을 이용한 종양선량 확인에 관한 연구 (IN-VIVO DOSE RECONSTRUCT10N USING A TRANSMISION FACTOR AND AN EFFECTIVE FIELD CONCEPT)

  • 김유현;여인환;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권1호
    • /
    • pp.63-71
    • /
    • 2002
  • The aim of this study Is to develop a simple and fast method which computes in-vivo doses from transmission doses measured doting patient treatment using an ionization chamber. Energy fluence and the dose that reach the chamber positioned behind the patient is modified by three factors: patient attenuation, inverse square attenuation. and scattering. We adopted a straightforward empirical approach using a phantom transmission factor (PTF) which accounts for the contribution from all three factors. It was done as follows. First of all, the phantom transmission factor was measured as a simple ratio of the chamber reading measured with and without a homogeneous phantom in the radiation beam according to various field sizes($r_p$), phantom to chamber distance($d_g$) and phantom thickness($T_p$). Secondly, we used the concept of effective field to the cases with inhomogeneous phantom (patients) and irregular fields. The effective field size is calculated by finding the field size that produces the same value of PTF to that for the irregular field and/or inhomogeneous phantom. The hypothesis is that the presence of inhomogeneity and irregular field can be accommodated to a certain extent by altering the field size. Thirdly, the center dose at the prescription depth can be computed using the new TMR($r_{p,eff}$) and Sp($r_{p,eff}$) from the effective field size. After that, when TMR(d, $r_{p,eff}$) and SP($r_{p,eff}$) are acquired. the tumor dose is as follows. $$D_{center}=D_t/PTF(d_g,\;T_p){\times}(\frac{SCD}{SAD})^2{\times}BSF(r_o){\times}S_p(r_{p,eff}){\times}TMR(d,\;r_{p,eff})$$ To make certain the accuracy of this method, we checked the accuracy for the following four cases; in cases of regular or irregular field size, inhomogeneous material included, any errors made and clinical situation. The errors were within 2.3% for regular field size, 3.0% irregular field size, 2.4% when inhomogeneous material was included in the phantom, 3.8% for 6 MV when the error was made purposely, 4.7% for 10 MV and 1.8% for the measurement of a patient in clinic. It is considered that this methode can make the quality control for dose at the time of radiation therapy because it is non-invasive that makes possible to measure the doses whenever a patient is given a therapy as well as eliminates the problem for entrance or exit dose measurement.

  • PDF

광간섭단층촬영술을 이용한 치아우식증의 발견 (Early caries detection using optical coherence tomography: a review of the literature)

  • 박영석;조병훈;이승표;손원준
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.367-376
    • /
    • 2011
  • 치아우식증의 조기 발견은 외과적 삭제를 피하면서, 적절한 치료를 할 수 있는 좋은 기회를 제공한다. 광간섭단층촬영술은 최근 각광받기 시작한 3차원 이미지 기술로서, 안과에서 광학적 생검의 목적으로 빈번히 이용되는 것을 필두로 다양한 의학 분야에 적용되어 왔고, 최근 초기 우식증의 발견에 전도유망하여 다양한 연구가 진행 중이다. 이 기술은 저 상관도 간섭계의 원리에 근거하고 있으며, 장점으로는 비침습적이고, 방사선을 사용하지 않으며, 3차원 이미지 구축이 가능하다는 점이다. 본 연구에서는 광간섭단층촬영술의 원리와 개략적인 개발 과정에 대한 기술과 함께 치아우식증에 관한 연구들에 대하여 고찰해 보았고, 이를 통해 이 기술의 응용 가능성을 확인하였다. 그럼에도 불구하고, 임상적인 유용성을 입증하기 위해서는 몇 가지 기술적 문제를 해결해야 하고, 보다 많은 생체 내 실험이 뒷받침되어야 할 것이다.

별아교세포 선택적 유전자 치료전달을 위한 PLGA 나노입자 개발 (Development of PLGA Nanoparticles for Astrocyte-specific Delivery of Gene Therapy: A Review)

  • 신효정;이가영;권기상;권오유;김동운
    • 생명과학회지
    • /
    • 제31권9호
    • /
    • pp.849-855
    • /
    • 2021
  • 최근에는 나노기술이 다양한 분야에 도입되고 활용되면서 신약개발이 가속화되고 있다. 나노입자는 약물의 단일 투여로 장기간 동안 혈중 약물 농도를 유지하고, 병리학적 부위에만 선택적으로 방출되는 장점이 있어 비병리 주위에 대한 부작용을 줄일 수 있다. Poly (D,L-lactic-co-glycolic acid) (PLGA)는 가장 광범위하게 개발된 생분해성 고분자 중 하나이다. PLGA는 다양한 응용분야의 약물전달에 널리 사용된다. 또한 FAD에 의해 약물전달 시스템으로 승인되었으며, 유전자 치료제와 같은 제어방출제형에 널리 적용된다. PLGA 나노입자는 수동 및 능동 표적화 방법을 사용하여 특정 세포 유형에 고효율의 전달 시스템으로 개발되었다. 이러한 PLGA 나노입자를 이용한 약물전달체 개발 후 표적 부위에 선택적으로 약물을 전달하고 질병에 따라 장기간 유효 혈중 농도를 최적화한다. 이 리뷰논문에서 우리는 유전자 치료를 위한 PLGA 나노 물질을 기반으로 하는 성상 세포 선택적 나노입자의 개발을 조사하여 세포 특이적으로 치료결과를 향상시키는 방법에 중점을 두고자 한다.

골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용 (Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis)

  • 김보경;지의규;허순녕;이형구;하성환
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.37-49
    • /
    • 2002
  • 방사선치료 시 종양에 정확한 양의 방사선을 조사하는 것은 국소 재발을 방지하고 합병증의 빈도를 낮춰 효과적인 치료를 가능하게 하는 중요한 요소이다. 종양에 조사되는 방사선량의 측정을 통해 치료의 정확성을 확인하기 위한 여러 방법들이 시도되고 있으며, 투과선량을 이용한 측정법도 그 중 한 예로 비침습적이며 매 치료 시 측정이 가능한 장점을 가지고 있다. 본 교실에서는 투과선량을 이용한 in vivo 선량측정시스템과 임의의 치료 조건에서 투과선량을 계산하기 위한 알고리즘을 개발하였다. 본 교실에서 개발한 in vivo 선량측정시스템의 단기간 및 장기간의 재현성을 확인하고, 환자의 방사선치료에서의 이용 시 발생할 수 있는 문제점을 파악하고 알고리즘의 정확성을 확인하기 위하여 본 연구를 시행하였다. 2000년 7월 25일부터 8월 14일 사이에 방사선치료를 시행 받은 환자 66명을 대상으로 투과선량의 측정을 시행하였으며, 이 중 골반부위의 방사선 치료를 3회 이상 시행 받은 11명의 환자를 대상으로 측정선량과 예측선량의 비교 분석을 시행하였다. 측정시스템의 재현성의 확인을 위하여 환자의 치료 전 및 치료 중 매시간 기준 조사조건에서 측정치를 확인하였다. 일별 및 일 중 변동은 ${\pm}2%$ 이내로 재현성을 확인할 수 있었다. 본 시스템의 사용 시 별다른 문제점은 없었으나, 2명의 흉부 치료환자에서 투과선이 치료용테이블의 측면 금속을 관통하는 문제가 발생하였다. 골반부위 환자에서는 골반부위의 불균질조직에 의한 영향의 확인을 위하여, CT 및 simulation film을 이용하여 골 조직의 두께를 확인하여 보정 전 및 후의 값을 비교하였다. 전후방 및 후방조사야의 경우 골 조직의 보정을 시행하지 않은 경우 평균오차가 -5.20% 내지 +2.20%이었으며, 보정을 시행한 경우 -0.62%내지 +3.32%로 환자에 따라 정도의 차이는 있으나 골 보정이 필요함을 확인할 순 있었다. 측정치와 예측치 간 오차의 표준편차는 1.19%내지 2.46%로서 재현성이 높음을 확인할 수 있었다. 좌우 측방조사야에서 골 보정을 시행하지 않은 경우 평균오차는 -10.80%내지 +3.46%로서 골 조직의 보정이 필요하지 않은 1인의 환자를 제외하면 모두 음수 값을 지녔고, 보정을 시행한 경우 -0.55% 내지 +3.50%의 평균오차를 지녀 골 보정의 필요성을 확인할 수 있었다. 측정치와 예측치 간 오차의 표준편차는 1.09%내지 6.98%로 전후방조사야의 경우보다 재현성이 낮음을 알 수 있었다. 복와위로 방사선치료를 시행 받은 환자의 경우를 제외하면, 표준편차는 1.09%내지 3.12%로 1례 외에는 2.57% 이내로 재현성이 높음을 확인할 수 있었다. 본 실험을 통하여 in vivo 선량측정시스템의 안전성과 재현성을 확인할 수 있었다. 정확한 예측치를 얻기 위하여 불균질 조직이 조사야에 포함되는 경우 보정이 요구되며, 골반의 경우 골 조직의 보정이 중요한 요인임을 알 수 있었다. 이를 위하여 불균질 조직에 대한 정확한 정보가 요구되며, 이는 CT 영상을 이용하는 것이 크게 도움이 되리라 생각된다.

방사선사 업무의 발전에 관한 조사 연구 (Study on Development in Professional Work of Radiological Technologists)

  • 최종학;김창균;김원철;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.197-210
    • /
    • 2006
  • 방사선기술 분야는 비약적으로 확대되고 있고, 중앙화 집약화 표준화 전문화되고 있다. 이를 기반으로 하는 방사선사의 역할 및 업무영역은 해를 거듭할수록 더욱 고도화, 전문화되고 있음은 폭넓게 인정된 사실이다. 이 연구는 우리나라에서 방사선사와 관련한 면허제도, 교육, 전문적 업무, 법률의 변천과정과 실태 및 동향을 조사하고 분석하여, 향후 전문 직업으로서 방사선사의 발전 전략을 모색하고자 수행하였다. 조사한 자료를 분석 및 검토하여, 다음과 같은 결과를 얻었다. 방사선사의 국가면허 제도는 1965년부터 시작되었으며, $1965{\sim}1972$년에는 엑스선사(의료보조원), 1973년${\sim}$2006년 현재까지 방사선사(의료기사) 면허로 시행되었다. 방사선사 국가시험$(1965{\sim}2006년)$의 평균 합격률은 46.6%이었다. 앞으로 국가시험에서 시험방법, 시험과목, 문항 수준 등을 개선할 필요가 있다. 방사선사 양성 대학의 교육연한은 $1963{\sim}1990$학년도는 2년, $1991{\sim}1999$학년도는 3년, $2000{\sim}2006$학년도는 4년과 3년제로 운영되었다. 2006학년도 현재, 4년제 대학교 12개, 3년제 대학 18개이었고, 입학정원은 1,956명이었다. 의료와 과학의 발달에 따라, 방사선기술과학 교육의 발전적 패러다임을 구축해야 한다. 전문방사선사 제도는 2004년부터 민간자격(대한방사선사협회 주관)으로 운영하고 있으며, 앞으로 국가자격으로 발전시킬 필요가 있다. 방사선사와 의료인, 의료종사자 사이의 수직적, 수평적 관계를 법률 개정을 통해 재정립 하여야 한다. 특히, 의사 또는 치과의사의 의료기사에 대한 '지도' 권한은 '처방 또는 의뢰'로 개정하여야 한다. 의료현장에서 방사선사의 전문적 업무상황을 반영하여 '방사선사의 업무범위'를 확대하고, 업무범위를 규정한 의료기사 등에 관한 법률을 개정하여야 한다.

  • PDF

가정간호실무에 적용가능한 이론적틀 (Appling Nursing Theory to Clinical Practice of Home Health Care)

  • 우선혜
    • 가정∙방문간호학회지
    • /
    • 제11권1호
    • /
    • pp.5-13
    • /
    • 2004
  • The home health care industry has grown rapidly and can be expected to continue to grow in the foreseeable future. Home health care refers to the practice of nursing applied to clients with a health condition in the clients place of residence. clients and their designated care givers are the focus at home health nursing practice. The goal of care is to initiate. manage and evaluate the resources needed to promote the clients optimal level of well-being and function. Nursing activities necessary to achieve this goal may warrant preventive maintenance and restorative emphases to prevent potential problems from developing. Many project program were suggested home health care model for Korea's health care system and policy direction for expansion and establishment of home health care .But the aim of this paper is to provide on overview for theoretical frame work in home health care. Theories and conceptual frameworks or models are important nursing because they define and guide the boundaries of professional practice and identify key nurse-patient-caregiver relationships that emerge with caring. Following is the research with an investigation of the literature review in the University of Arizona international medline database, In conclusion, are as followers: First, many nursing theorists have had a tremendous impact on nursing practice. the following highlights those nursing theorists that are particularly helpful in understanding home health care. 1. Florence Nightingale : Our earliest theoretical legacy. Nightingale's believes are reflected in basic infection control practice such as hand washing and infectious waste disposal and are key nursing interventions in home care. 2. Martha Roger's :Science of unitary human beings theory. Rorger's believed that the focus of shared. non invasive healing modelities is the human environmental field rather than direct physical care. These modelities continue to evolve as our awareness (reflecting greater diversity, faster rhythms, motions, and ways of knowing) transcends time and space, allowing individuals to get in touch with their integral nature of unbroken wholeness. On people as ever changing energy fields have special relevance in home care especially with hospice and palliative care applications. 3. Madeline Leininger's; Transcultural nursing theory. Home care nurses move through a variety of communities and often care for patients from different cultural back grounds. Therefore Leininger's work has a good that with home care because home care nursing practice is very culturally focused. 4. Dorothea Orem's : Self care deficit theory. Orem's theory views care as something to be performed by both nurses and patients. The role of the nurse is to provide education and support that help patients acquire the necessary activities to perform self-care. Orem's theory is foundational to have care because it begins to truly acknowledge the role of the patient in managing his or her own health. which is referred to as self-care. 5. Margaret Neuman's; Health as expending consciousness theory. Neuman believes that health compasses disease and reflects an underlying pattern of person-environment interaction. A key application of 'Neuman's work to home care is for nurses to understand that health and illness do not necessarily exist at opposite ends of a continuum. 6. Jean Watson's: Theory of human caring. Watson's theory of human caring in nursing proposes human caring as the moral ideal of nursing. Nurses participate human caring to protect, enhance and preserve humanity by assisting individuals to fing meaning in illness. pain and existence and to help others gain self knowledge. self control. and self healing such thinking lends richness to theory development. as well as clinical practice in home care. Second, Robin Rice : Dynamic self determination for self care. (A theoretical framework for home care) Dynamical self determination for self care can be useful to home care nurses in a variety of ways. As research tool it can be reflected in the interview process when the home visit. The home care nurse's role is that of facilitator of patient self-determination for self care through numerous strategies. including patient education and case management.

  • PDF

실험 쥐 해마조직배양에서 전자기 자극이 신경조직발생 및 증식에 미치는 영향 (Effects of electromagnetic stimulation on neurogenesis and neuronal proliferation in rat hippocampal slice culture)

  • 김덕수;최응상;채수안
    • Clinical and Experimental Pediatrics
    • /
    • 제49권5호
    • /
    • pp.558-564
    • /
    • 2006
  • 목 적 : 경뇌 전자기 자극법은 변조 자기장을 이용하여 뇌세포에 대한 직접적인 영향을 주지 않으면서 중추 신경계를 자극할 수 있는 비침습적인 방법이다. 이전의 연구들은 대부분 생체 동물을 대상으로 수행되어져 왔으며 배양 조직에서의 연구는 별로 이루어진 바 없다. 이에 본 연구에서는 배양된 해마 절편에서 다른 주파수의 전자기 자극이 신경원에 미치는 영향과 약물에 의한 세포 손상 후 전자기 자극의 세포보호효과 여부에 대해 알아보고자 하였다. 방 법 : 생후 8일된 실험쥐의 대뇌를 적출하여 dissection microscope 하에서 양쪽 해마 부위를 분리하고 tissue chopper를 이용하여 $450{\mu}M$ 두께로 절편을 만든 후 Stoppini가 고안한 방법대로 배양을 시행하였다. 각각 5개의 건강한 해마 절편이 포함된 inserts를 선택하고, 전자기 자극군에 대해 0.67 Hz와 50 Hz의 주파수로 각각 배양 5일부터 3일 간격으로 6차례 전자기 자극을 가하였다. 또한, 배양 제 14일에 inserts 2개에 $100{\mu}M$ NMDA에 노출시키고 3일 후부터 3일 간격으로 insert 1개에 전자기 자극을 3차례 시행하였고 다른 1개의 insert와 대조군에는 자극을 가하지 않았다. 결 과 : 전자기 자극 후 신경원의 활성도를 알아보기 위해 NeuN 단백 발현을 western blotting을 이용하여 측정한 후 ${\beta}$-actin 단백 발현과의 비를 얻어 각 군에서 비교 분석하였다. 대조군($1.01{\pm}0.27$)에 비해 전자기 자극군에서 NeuN의 발현이 증가되어 있었으며, 특히 저주파 자극군($1.12{\pm}0.14$)에서보다 고주파 자극군($1.27{\pm}0.17$)에서 현저하였고 고주파 자극군에서는 대조군에 비해 통계적으로 유의한 증가를 보였다(P<0.05). 또한, NMDA 노출 후 실험군(전자기 자극군 : $1.15{\pm}0.27$, 전자기 비자극군 : $0.92{\pm}0.09$)에서 대조군($1.26{\pm}0.04$)에 비해 NeuN 발현이 감소되었으나 전자기 비자극군에서 더 많이 감소한 것을 알 수 있었다. 결 론 : 배양된 해마조직의 신경세포에 대한 전자기 자극은 저주파 자극군에 비해 고주파 자극군에서 대조군보다 통계적으로 유의한 수준의 NeuN 발현의 증가를 관찰할 수 있었고, NMDA 노출 후 전자기 자극을 가한 군에서 대조군보다 NeuN 발현 감소가 관찰되기는 하였으나 고주파 자극군에서는 통계적으로 유의하지 않은 정도였던 것으로 보아 전자기 자극이 신경원 활성을 증가시켜 신경세포의 발생 및 증식을 유도하며 세포 손상에 대한 신경보호효과도 보인다는 것을 알 수 있었다. 따라서 전자기 자극은 여러 신경 질환에 있어서 치료적 역할을 할 수 있는 가능성이 있다고 사료된다.

국소진행성 직장암에서 수술 전 방사선 및 항암화학 동시요법의 효과 (Efficacy of a Preoperative Concurrent Chemoradiotherapy for the Locally Advanced Unresectable Rectal Cancer)

  • 조재호;성진실;금기창;김귀언;서창옥;노재경;정현철;민진식;김남규
    • Radiation Oncology Journal
    • /
    • 제18권4호
    • /
    • pp.293-299
    • /
    • 2000
  • 목적 :직장암에서 완치를 기대할 수 있는 치료는 수술요법이다. 진행성 병변으로서 근치절제가 불가능한 경우에 있어서는 수술 전 보조요법을 통해 절제연이 음성인 근치절제율을 높이고자 하는 노력이 시도되고 있다. 이에 저자들은 수술 전 방사선 및 항암화학 동시요법으로 근치 절제율을 높여 치료성적을 향상시키기 위하여 전향적 임상 연구를 시행하였다. 대상 및 방법 : 1995년 1월부터 1998년 6월까지 국소적으로 진행된 직장암으로 내원하여 수술전 병기결정 검사를 통하여 근치적 절제가 불가능하다고 판단된 37명의 환자가 본 연구에 포함되었다. 수술전 병기결정은 직장수지검사, 경직장초음파, 컴퓨터단층촬영, 자기공명영상 등을 이용하였다. 방사선 치료는 3 문 내지 4 문 조사식으로 총 45$\~$50.4 Gy를 시행하였으며, 방사선 치료 첫째 주와 다섯째 주에 항암화학요법(5-Fluerouracil, 370$\~$450 mg/m$^{2}$, IV bolus, 5 days; Leucovorin 20 mg/m$^{2}$, IV bolus, 5 days)이 동시에 투여되었다. 방사선 치료 후 4$\~$6주 후에 근치적절제술을 시행하였다. 전체 37명의 환자 중 31명에서 계획된 방사선 및 항암화학 동시요법 후 근치적 수술이 시행되었고, 나머지 6명은 환자 이해부족으로 치료가 중단 된 경우 4예, 치료중 진행성 병변(Peforation)으로 응급수술을 시행한 후 방사선 단독치료를 한 경문 1예, 그리고 1예에서는 방사선 및 항암화학 동시요법을 시행 후 수술하기 전에 폐전이가 발견되어 전신항암화학 요법만을 시행하였다. 결과: 계획된 치료가 시행된 환자 중 94$\%$ (29/31)에서 절제연 음성인 완전근치절제가 가능하였으며, 병리적 완전관해율은 6$\%$ (29/31), 임상적 완전관해율은 23$\%$ (7/31)이었다. 수술 전 병기 감소율은 68$\%$에서 관찰되었다. 수술은 2예에서 국소 절제술, 14예에서 저위전방절제술, 8예에서 복회음부 절제술, 4예에서 하트만씨 절제술, 3예에서 부분 내용제거술을 시행되었다. 치료와 연관된 급성 독성으로는 Grade III & IV의 백혈구 감소증 각각 4예(13$\%$), 2예(6$\%$)를 제외하고는 대부분 경미하였다. 결론: 국소적으로 진행되어 근치적 절제가 어려운 직장암에서 계획된 수술 전 방사선 및 항암화학 동시요법을 통해서 수술 후 병기 감소(68$\%$)와 높은 완전근치절제율(94$\%$)을 얻을 수 있었다. 치료에 따른 독성도 대부분 경미하여 좋은 순응도를 보였다. 나아가 이러한 치료를 통해 얻어지는 국소 제어율과 전체 생존율에 대해서는 향후 추적 관찰을 통해 분석해 나갈 예정이다.

  • PDF

식도암 방사선 치료에 대한 Patterns of Care Study ($1998{\sim}1999$)의 예비적 결과 분석 (Preliminary Report of the $1998{\sim}1999$ Patterns of Care Study of Radiation Therapy for Esophageal Cancer in Korea)

  • 허원주;최영민;이형식;김정기;김일한;이호준;이규찬;김정수;전미선;김진희;안용찬;김상기;김보경
    • Radiation Oncology Journal
    • /
    • 제25권2호
    • /
    • pp.79-92
    • /
    • 2007
  • 목 적: 전국 병원의 방사선종양학과에서 식도암으로 방사선 치료를 받은 환자들을 각 병원으로부터 입력 받아 세부 항목별로 분석하여 식도암 환자들의 구성과 특징을 파악하여 범국가적인 자료로 활용하는 한편 치료방침을 분석하여 향후 적절한 치료를 위한 가이드라인으로 삼고자 하였다. 대상 및 방법: 전국 병원의 방사선종양학과에서 1998년과 1999년의 2년간에 걸쳐 식도암으로 확진된 246명을 대상으로 하였다. 연간 400명 미만의 방사선치료 신환자 발생병원들을 A군, 400명 이상 900명 미만의 병원들을 B군, 그리고 900명 이상 신환자가 발생하는 병원을 C군으로 분류하여 최종적으로 A군에서 12병원, B군에서 8개 병원, 그리고 C군에서 3개의 병원이 연구에 참여하였다. 이미 개발된 Web-based Korean PCS system을 통해 각 병원으로부터 직접 자료를 입력 받아 이를 세부 항목별로 분석하였고 통계적 처리는 SPSS version 12.0.1을 사용하고 범주형 자료는 Chi-squared test를 사용하였고 연속변수는 ANOVA, Kruskal-Wallis test를 적용하였다. 결 과: 입력된 환자들의 성별 분포는 남자 224명(91.1%), 여자 22명(8.9%)이었고 연령별 중앙값은 62세 전후였다. 진단 및 병기결정을 위한 검사로는 식도 촬영술(228명, 92.7%), 식도내시경(226명, 91.9%) 및 흉부 식도 CT 스캔(238명, 96.7%)을 주로 시행하였다. 편평상피암이 대종을 이루어 237명(96.3%)의 환자에서 관찰되었고 중흉부식도(mid-thoracic esophagus)에서 발생한 식도암이 가장 많았다(110명, 44.7%). 임상 병기는 III기가 과반수 이상을 차지하였다(135명, 54.9%). 방사선 치료만 받은 경우는 57명(23.2%), 방사선 치료와 수술을 병용한 경우는 전체의 15%인 37명, 항암약물 치료와 방사선 치료를 병용한 경우는 123명(50%)이었다. 수술과 방사선 치료를 병행한 경우 전례에서 수술을 먼저 시행한 후 방사선 치료를 하였다. 항암치료를 방사선치료와 병행한 경우 반수 이상에서(70명, 56.9%) 동시항암방사선 치료를 시행하였고 31명(25.2%)에서 항암치료 후 방사선치료를 또는 항암요법 단독치료 후 동시항암방사선치료를(13명, 10.6%) 시행하였다. 방사선 치료는 6 MV (116명, 47.2%)와 10 MV (87명, 35.4%)의 X-ray가 대종을 이루었다. 방사선 치료 시 조사야는 longitudinal margin의 경우 중앙값은 7.0 cm이었지만 각 군별로 현저한 차이가 있었다(A군; 5.5 cm, B군; 8.0 cm, C군; 14.0 cm). 계획용 CT를 사용하지 않고 고식적인 AP/PA 조사야를 사용하여 치료한 경우가 대부분이었는데(206명, 83.7%) 이 때 방사선 조사량의 중앙값은 3,600 cGy이었다. 이후 추가 방사선 치료 시 계획용 CT를 사용하지 않고 2-oblique fields 사용하여 치료한 경우가 87명(35.4%)이었는데 방사선 조사량의 중앙값은 1,800 cGy이었다. 전 환자에서 1일 1회 180 cGy로 치료하였다. 전 환자에서 조사된 총 방사선량의 중앙값은 5,580 cGy이었다. 수술 후 방사선 치료를 시행한 경우 중앙값은 5,040 cGy이었고 수술을 받지 않은 환자 중앙값은 5,940 cGy이었다. 근접조사 방사선 치료는 총 34명(13.8%)에서 시행되었고, 전 환자에서 high dose rate Iridium-192를 사용하였다. 조사범위는 종양에서 longitudinal margin의 중앙값은 1 cm, prescribed isodose curve에서 axial length의 평균값은 8.25 cm, 폭은 2 cm, 그리고 전후 폭의 중앙값도 2 cm이었다. Fraction size의 중앙값은 300 cGy이었는데 B군의 경우는 500 cGy이었다. 총 분할 횟수는 $3{\sim}4$회가 대부분이었다. 한편, 방사선 치료 중 발생한 급성 부작용은 식도염이 가장 많았는데 전체 246명 환자 중 155명(63.0%)에서 발생하였다. 결 론: 전국 23개 병원의 식도암 환자 치료 Data를 분석해 본 결과 대부분의 병원에서 환자의 특징과 진단 및 병기 결정 방법, 치료의 유형 등에서 유사한 결과를 보였으며 신환 발생 수에 따른 병원 규모의 차이는 조사 결과에 큰 영향을 미치지 못하였다. 하지만 병원 규모가 클수록 10 MV 이상의 고에너지로 치료하는 경향이 많았으며 3D CT Plan도 병원 규모가 클수록 활용도가 높았다. 조사 야의 면적도 병원 군별로 차이를 보였다. 향후 더 많은 환자를 입력하여 생존율 분석까지 이루어지면 이 연구는 식도암 치료방침의 결정에 중요한 guideline을 제시해 줄 것으로 사료된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF