• Title/Summary/Keyword: Non-Polar Solvent

Search Result 73, Processing Time 0.019 seconds

A comparison of desorption efficiency by types of solvent for polar and non-polar organic compounds collected on activated charcoal tube (활성탄관에 포집된 극성 및 비극성 유기용제 분석시 탈착용매 종류에 따른 탈착효율 비교)

  • Son, Yonjoo;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.3-18
    • /
    • 1997
  • This study was conducted to evaluate desorption efficiencies by types of desorption solvent for polar and non-polar organic compounds collected on activated charcoal tubes. Analytes tested were toluene, m-xylene, isobutyl alcohol, n-butyl alcohol, cellosolve acetate, and butyl cellosolve. Three different concentration levels of spiked sample were made. Types of cosolvent mixed with the main solvent, $CS_2$, were methanol, pentanol, and dimethylformamide (DMF) and the cosolvent for methylenechloride was methanol. The amounts of cosolvent added to the main solvent were 1, 5, and 10% by volume (v/v%), respectively. The results were as follows: 1. For all mixed solvents except 1% methanol and 1% pentanol with $CS_2$, desorption efficiency significantly increased, compared with that of $CS_2$ alone. 2. Desorption efficiency increased by increasing analyte loading on charcoal tube regardless of mixed solvents used and the material polarity. 3. For all cosolvents mixed with $CS_2$ by 1% and 5% volume, desorption efficiency for non-polar compound was significantly higher than that of polar compound. For the 10% mixed solvents and the methylenechloride mixed with methanol, the results were opposite. 4. The lowest mean percent bias of 4.79% was obtained from the 5% DMF-$CS_2$ mixed solvent, followed by 4.82% from the 10% DMF-$CS_2$ solvent while the highest bias of 23.26% was from the solvent of $CS_2$ alone. Based on the results of this study, in order to increase desorption efficiency, it is recommended to add such cosolvents as methanol, pentanol, and DMF to $CS_2$, preferably 5% by volume for analyzing polar compounds collected in charcoal tubes.

  • PDF

Desorption Efficiency of Various Cosolvents for Organic Solvent Mixtures Collected on Activated Charcoal Tube (활성탄관에 포집된 혼합 유기용제의 보조탈착용매 변화에 따른 탈착률 비교)

  • Kim, Kang Yoon;Ro, In Bong;Kim, Hyun Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.209-221
    • /
    • 1996
  • The purpose of this study was to find a suitable cosolvent to $CS_2$ so that desorption efficiency can be improved for both polar and non-polar organic solvent mixtures collected on an activated charcoal tube. Cosolvents added to $CS_2$ include: DMF(N,N-dimethylformamide): $CS_2$ (v/v 1:99), DMF:$CS_2$(v/v 3:97), BC (butyl carbitol, 2-(2-butoxy ethoxy) ethanol):$CS_2$(v/v 1:99), and BC:$CS_2$(v/v 3:97)). The results obtained were as follows : 1. Comparing the desorption efficiency of $CS_2$ with those of $CS_2$ with 1, 3, 5 % DMF and 1, 3 % BC cosolvents for two different groups of charcoal tubes each containing 8 different polar and non-polar organic solvents with 3 different concentration levels, the desorption efficiencies of the cosolvent-added $CS_2$ increased significantly for all polar organic solvents regardless of concentration levels tested. For non-polar organic solvents, no noticeable improvement was detected except xylene and trichloroethylene. The desorption efficiency of xylene increased significantly while that of trichloroethylene increased significantly at the lowest concentration level tested. 2. Either 5 % DMF or 3 % BC was the most suitable cosolvent because the desorption efficiency for non-polar organic solvent mixtures was similar or slightly improved compared with that of $CS_2$, while those of for polar organic solvent mixtures were above 75 % except for cyclohexanone. 3. The smallest variations in desorption efficiency represented by the ratio calculated from the maximum to minimum desorption efficiency for all concentration levels tested were found when 3 % BC was used as a cosolvent. The above results indicate that the desorption efficiency of $CS_2$ particularly for polar organic solvent mixtures collected on a charcoal tube can be significantly improved by the use of cosolvents such as 5 % DMF or 3 % BC. A caution, however, is in order for selecting a cosolvent whenever the cosolvent itself is being used in the workplace or the impurities contained in the cosolvent may interfere with the analytical results. In addition, to improve desorption efficiencies for such organic solvents as cyclohexanone or ketones, it is recommended to use suitable collection and desorption media other than the traditional method of charcoal tube collection/$CS_2$ desorption.

  • PDF

The Rheology of the Silica Dispersion System with Single and Mixed Solvent (단일 및 혼합 용매계 실리카 분산체의 점도 특성 및 유변학적 거동)

  • Ahn, Jae-Beom;Noh, Si-Tae
    • Applied Chemistry for Engineering
    • /
    • v.20 no.6
    • /
    • pp.685-691
    • /
    • 2009
  • Dispersions of fumed silica are made in 6 kinds of mono-solvents and mixed solvents which have hydroxyl group, non hydroxyl group, different polarity, and different molecular size. The viscosity and rheology behaviors of the each dispersion are investigated according to the viewpoint of solvent characteristic. The silica dispersion in polar solvent with hydroxyl group is stable and low viscous sol. The silica dispersion in non-polar solvent with non-hydroxyl group is high viscous gel. When the solvent with hydroxyl group is added to the silica dispersions with non-polar solvents, they show the reduction of viscosity with solvent content. They have minimum critical content which shows no viscosity change. The minimum critical solvent content is decreased according to the polarity of solvents with no hydroxyl group. The solvation layer which is formed on the silica surface through hydrogen bonding between hydroxyl-containing solvent and the silanol group of silica surface is the reason of stable and low viscous sol. In case of non-polar solvent, silanol on adjacent silica particles interacted directly by hydrogen bonding show high viscous and flocculated gel.

Characterization of Heterogeneous Interaction Behaviour in Ternary Mixtures by Dielectric Analysis: The H-Bonded Binary Polar Mixture in Non-Polar Solvent

  • Sengwa, R.J.;Madhvi;Sankhla, Sonu;Sharma, Shobha
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.718-724
    • /
    • 2006
  • The heterogeneous association behaviour of various concentration binary mixtures of mono alkyl ethers of ethylene glycol with ethyl alcohol were investigated by dielectric measurement in benzene solutions over the entire concentration range at 25 ${^{\circ}C}$. The values of static dielectric constant $\epsilon_0$ of the mixtures were measured at 1 MHz using a four terminal dielectric liquid test fixture and precision LCR meter. The high frequency limiting dielectric constant $\epsilon_\infty$ values were determined by measurement of refractive index $n_D$ ($\epsilon_\infty\;=\;n_D\;^2$). The measured values of $\epsilon_0$ and $\epsilon_\infty$ were used to evaluate the values of excess dielectric constant $\epsilon^E$, effective Kirkwood correlation factor $g^{eff}$ and corrective correlation factor $g_f$ of the binary polar mixtures to obtain qualitative and quantitative information about the H-bond complex formation. The non-linear behaviour of the observed $\epsilon_0$ values of the polar molecules and their mixtures in benzene solvent confirms the variation in the associated structures with change in polar mixture constituents concentration and also by dilution in non-polar solvents. Appearance of the maximum in $\epsilon^E$ values at different concentration of the polar mixtures suggest the formation of stable adduct complex, which depends on the molecular size of the mono alkyl ethers of ethylene glycol. Further, the observed $\epsilon^E$ < 0 also confirms the heterogeneous H-bond complex formation reduces the effective number of dipoles in these polar binary mixtures. In benzene solutions these polar molecules shows the maximum reduce in effective number of dipoles at 50 percent dilutions. But ethyl alcohol rich binary polar mixtures in benzene solvent show the maximum reduce in effective number of dipoles in benzene rich solutions.

Simultaneous Extraction and Separation of Oil and Azadirachtin from Seeds and Leaves of Azadirachta indica using Binary Solvent Extraction

  • Subramanian, Sheela;Salleh, Aiza Syuhaniz;Bachmann, Robert Thomas;Hossain, Md. Sohrab
    • Natural Product Sciences
    • /
    • v.25 no.2
    • /
    • pp.150-156
    • /
    • 2019
  • Conventional extraction of oil and azadirachtin, a botanical insecticide, from Azadirachta indica involves defatting the seeds and leaves using hexane followed by azadirachtin extraction with a polar solvent. In order to simplify the process while maintaining the yield we explored a binary extraction approach using Soxhlet extraction device and hexane and ethanol as non-polar and polar solvents at various ratios and extraction times. The highest oil and azadirachtin yields were obtained at 6 h extraction time using a 50:50 solvent mixture for both neem leaves (44.7 wt%, $720mg_{Aza}/kg_{leaves}$) and seeds (53.5 wt%, $1045mg_{Aza}/kg_{leaves}$), respectively.

Development of Cellulosic Fiber Filter Using Replacement Liquid in Water-Swollen Fiber with Non-Polar Solvent (Non-Polar 물질 수분치환에 의한 종이필터 개발)

  • Kim, Kwang Soo;Ahn, Kwang Ho;Park, Jae Ro;Kim, Hyun Jung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.10
    • /
    • pp.743-748
    • /
    • 2013
  • The purposes of this study are to prepare Hanji fiber-filter sheets using replacement liquid in water-swollen fiber with non-polar solvent such as ethanol, methanol and pentane. The experiments were studied on the selection of optimal non-polar solvent and the optimal drying method for wetted fiber and then were to know physicochemical characteristics of prepared Hanji fiber-filter sheet. The Ethanol as liquid changer in water-swollen fiber was excellent solvent and the optimal drying method for them was freeze drying served with vacuum pump. The bulk density and porosity of prepared fiber sheet from freeze dryer were 0.11-0.13 g/mL, half of natural dried fiber sheet, and 90%, respectively. The results of SEM observation for the fiber sheet prepared with natural drying or heating drying were shown very close structure of fiber wall in dry state. However, the freeze drying sheet were shown the open structure. So, the head loss of freeze drying sheet was very lower than natural drying and heating drying sheets. From the results of BTEX removal experiments, the sheets dried at water wetted condition was shown more higher efficiency than the fiber sheets dried at solvent wetted condition.

The Solubility Characteristics of Organic Compounds in Urban Aerosol Samples

  • Kim, Young-Min;Peter Brimblecombe;Tim Jickells;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.E
    • /
    • pp.27-40
    • /
    • 1998
  • The solubility characteristics of organic compounds were studied in terms of the extraction efficiency as a function of the polarity of the organic solvent, and the acidity of water in urban aerosol samples collected in University of East Anglia (UEA), Norwich, England. The extraction efficiency of organic compounds were evaluated with respect to the organic carbon, -nitrogen and -hydrogen by means of a wide range of solvent which include polar and nonpolar organic solvents as well as acids and alkaline water. In addition, after being dissolved in aqueous solution, the aqueous chemistry of organic compounds were studied in terms of the organic metal complexes in aerosol, which were studied with oxalic acid, copper, and zinc. The results of this study indicate that solubility characteristics of organic compounds depend on the polarity of the solvents and the acidity of the solvents. In particular, some organic compounds are water soluble, even though they are much smaller than acetone soluble fractions. In the comparison between polar organic solvent extraction and non- polar organic solvent extraction, it can be thought that significant fraction of organic compounds analysed in the aerosol samples, are polar organic compounds because of the higher extraction efficiencies of organic compounds in polar organic solvent extraction than in nonpolar organic solvent extraction. Regarding the study of the oxalic -metal complexes, it can be thought that most oxalic acids are present in the form of oxalic -copper complexes in the aerosols collected at UEA.

  • PDF

Acoustic Studies on Different Binary Liquid Mixtures of LIX Reagents with Different Diluents

  • Kamila, Susmita
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.5
    • /
    • pp.548-555
    • /
    • 2012
  • Ultrasonic velocity and density measurements have been undertaken for a number of binary liquid mixtures involving different commercial solvent extractants, LIX reagents. The binary mixtures under investigation have been classified under two categories such as polar-polar, and polar-non-polar types. Different theories and relations such as Schaaff's Collision Factor Theory (CFT), Nomoto's relation (NOM), and Van Dael & Vangeel ideal mixing relation (IMR) have been used to evaluate the velocity theoretically for all these binary systems. The relative merits of afore-mentioned theories and relations compared to experimental values of velocity have been discussed in terms of percentage variations. However, the CFT and Nomoto's relation show better agreement with the experimental findings than the ideal mixing relation for all the systems under investigation.

Monte Carlo Simulation Study of Solvent Effect on Selectivity of 18-Crown-6 to between La3+ and Nd3+ Ion

  • Kim, Hag-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.6
    • /
    • pp.751-756
    • /
    • 2003
  • We have investigated the solvent effects on Δlog $K_s$ (the difference of stability constant of binding) and the relative free energies of binding of $La^{3+} and Nd^{3+}$ ions to 18-crown-6 by a Monte Carlo simulation of statistical perturbation theory (SPT) in diverse solvents. We compared relative binding Gibbs free energies and the differences in stability constant (Δlog $K_s$) of binding of $La^{3+} and Nd^{3+}$ ions to 18-crown-6 in $CH_3OH$ in this study with the experimental. There is a good agreement between our study and the experimental. We noted that Borns function of the solvents, the electron pair donor properties of the solvent, the radii of host and guest and the differences in solvation dominate the differences in the stability constant (Δlog $K_s$) as well as the relative free energies of binding of TEX>$La^{3+} to Nd^{3+}$ ions to 18-crown-6. The results of this study appear promising for providing the association properties of crown ethers with alkaline earth metals among polar solvents and the less polar or non-polar solvents.

Electron Spin Resonance (ESR) and Microwave Absorption Studies of Superparamagnetic Iron Oxide Nanoparticles (SPIONs) for Hyperthermia Applications

  • Choi, Yong-Ho;Yi, Terry;Kim, Do-Kyung
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.6
    • /
    • pp.577-583
    • /
    • 2011
  • Stabilized biocompatible superparamagnetic iron oxide nanoparticles (SPIONs) were prepared by controlled coprecipitation method for hyperthermia application. ESR measurements determined that all of the interactions in the individual SPIONs (1 nm and 11 nm) were antiferromagnetic in nature because the ions contributed to the magnetization with a range of magnetic moments. In-situ monitoring of the temperature increment was performed, showing that the microwave absorption rate of the SPIONs was dispersed in an appropriate host media (polar or non-polar solvents) during microwave irradiation. Microwave absorption energy rates and heat loss of SPIONs in solvent were calculated by non-linear data fitting with an energy balance equation. The microwave absorption rates of SPIONs dispersed in solvent linearly increases when the concentration of SPIONs increases, implying that the microwave absorption rate can be tunable by changing the concentration of SPIONs.