• 제목/요약/키워드: Non-Normal Distribution

검색결과 378건 처리시간 0.032초

누드마우스에 이식된 인체대장암에서 I-131표지 항태아성암항원 단일클론항체를 이용한 방사면역치료법 : 치료성적에 관계되는 인자분석 (Radioimmunotherapy of Nude Mice Bearing Human Colon Carcinoma with I-131 Labeled Anti-carcinoembryonic Antigen Monoclonal Antibody)

  • 김병태;이경한;김상은;최용;지대윤;정준기;이명철;고창순;정홍근
    • 대한핵의학회지
    • /
    • 제29권3호
    • /
    • pp.332-342
    • /
    • 1995
  • This study was designed to evaluate the effects of various factors on the therapeutic effect of the I-131 labeled anti-carcinoembryonic antigen monoclonal antibody(anti-CEA antibody). Tetrazolium-based colorimetric assay (MTT) was used to compare in vitro cytotoxicity of 3 Korean colon cancer cell lines (SNU-C2A, SNU-C4, SNU-C5) for selection of proper 2 cell lines in this study. The changes of the size of tumor which was xenografted to nude mice (balb/c nu/nu) were compared in 4 groups (group treated I-131 labeled anti-CEA antibody, group treated with non-radiolabeled anti-CEA antibody, group treated with I-131 labeled anti-human chorionic gonadotropin monoclonal antibody (anti-hCG antibody) as nonspecific antibody, and group injected with normal saline as a control). Immunohistochemical staining and in vivo autoradiography were performed after excision of the xenografted tumor. The results were as below mentioned. The in vitro cytotoxic effect of I-131 labeled anti-CEA antibody is most prominent in SNU-C5 cell line between 3 cancer cell lines. The changes of xenografted tumor size in both SNU-C4 and SNU-5S cell tumors at the thirteenth day after injection of the antibodies were smallest in the group treated with I-131 labeled anti-CEA antibody (SNU-C4/SNU-C5; 324/342%) comparing with other groups, group treated with anti-CEA antibody (622/660%), group treated with I-131 anti-hCG antibody (538/546%), and control group(1030/724%)(P<0.02 in SNU-C4 and P<0.1 in SNU-C5 at the 13th day after injection of antibodies). On the thirteenth day after injection of the antibodies nude mice were sacreficed to count the radiouptake of tumor and to check the changes of tumor size. Correlations between radiouptake and change of tumor size were calculated in each groups and significant negative correlation was only obtained in the group treated with I-131 anti-CEA antibody (p<0.05). There were no correlations between antigenic expression of carcinoembryonic antigen and distribution of anti-CEA antibody in both SNU-C4 and SNU-C5 cell tumors on immunoperoxidase staining. On in vivo autoradiography the distributions of anti-CEA antibody were heterogeneous and the intensities of binding were various in SNU-C4 and SNU-C5 cell tumors. It is concluded that I-131 labeled tumor-specific monoclonal antibody, anti-CEA antibody is effective in suppressing the xenografted tumor growth and the effect is influenced by sensitivity of tumor cell itself to the radiolabeled antibody and other local factors instead of specificity of antibody.

  • PDF

국내 10개 댐저수지 인공습지의 운영현황 및 개선방안 (Operating Status and Improvement Plans of Ten Wetlands Constructed in Dam Reservoirs in Korea)

  • 최광순;김세원;김동섭;이요상
    • 한국습지학회지
    • /
    • 제16권3호
    • /
    • pp.431-440
    • /
    • 2014
  • 국내 10개 댐저수지 인공습지를 대상으로 수심분포, 유입량 및 유출량, 물흐름분포, 체류시간, 수처리효율, 종횡비, 개방수역/폐쇄수역 구성비 등 습지의 운영현황 및 구조적 형상에 대한 분석을 통해 인공습지의 수질정화기능을 회복시킬 수 있는 개선대책 및 운영방안을 제시하였다. 조사대상 인공습지의 처리수는 하수처리장 방류수 또는 하천수였으며, 처리수의 수질은 외국의 인공습지에 비해 전반적으로 낮은 것으로 나타났다. 특히 처리수의 BOD는 모든 습지에서 3 mg/L 이하로 매우 낮았는데, 이는 하수처리장의 고도처리 및 평수기 저농도 하천수 취입에 기인된 것으로 판단된다. 수처리효율은 TN이 7.6~67.6%(평균 24.9%), TP가 -4.9~74.5%(평균 23.7%)의 범위로 하수처리장 방류수를 처리수로 하는 인공습지에서 높은 값을 보였다. BOD는 -133.3~41.7% 범위로 습지에 따라 큰 차이를 보였으며, 대부분 습지에서 처리효율이 없거나 낮은 것으로 나타났다. 인공습지의 낮은 처리효율은 습지의 부적합한 종행비, 과도한 개방수역 면적 등의 구조적인 문제와 수위관리 미흡, 초기우수 취입시스템 및 운영관리 미흡, 강우시 모니터링 부재 등의 운영적인 문제에 의한 것으로 나타났다. 그러므로 댐저수지 인공습지가 비점오염 저감시설로서의 역할을 할 수 있기 위해서는 댐저수지 인공습지에 적합한 습지설계 및 운영방안이 필요하다. 또한 습지 운영매뉴얼에 비점오염물질이 유출되는 강우시 모니터링이 반드시 포함되어야 하며, 댐저수지 인공습지의 수처리효율도 강우시 모니터링 자료를 토대로 평가되어야 할 것이다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Support Vector Regression을 이용한 GARCH 모형의 추정과 투자전략의 성과분석 (Estimation of GARCH Models and Performance Analysis of Volatility Trading System using Support Vector Regression)

  • 김선웅;최흥식
    • 지능정보연구
    • /
    • 제23권2호
    • /
    • pp.107-122
    • /
    • 2017
  • 주식시장의 주가 수익률에 나타나는 변동성은 투자 위험의 척도로서 재무관리의 이론적 모형에서뿐만 아니라 포트폴리오 최적화, 증권의 가격 평가 및 위험관리 등 투자 실무 영역에서도 매우 중요한 역할을 하고 있다. 변동성은 주가 수익률이 평균을 중심으로 얼마나 큰 폭의 움직임을 보이는가를 판단하는 지표로서 보통 수익률의 표준편차로 측정한다. 관찰 가능한 표준편차는 과거의 주가 움직임에서 측정되는 역사적 변동성(historical volatility)이다. 역사적 변동성이 미래의 주가 수익률의 변동성을 예측하려면 변동성이 시간 불변적(time-invariant)이어야 한다. 그러나 대부분의 변동성 연구들은 변동성이 시간 가변적(time-variant)임을 보여주고 있다. 이에 따라 시간 가변적 변동성을 예측하기 위한 여러 계량 모형들이 제안되었다. Engle(1982)은 변동성의 시간 가변적 특성을 잘 반영하는 변동성 모형인 Autoregressive Conditional Heteroscedasticity(ARCH)를 제안하였으며, Bollerslev(1986) 등은 일반화된 ARCH(GARCH) 모형으로 발전시켰다. GARCH 모형의 실증 분석 연구들은 실제 증권 수익률에 나타나는 두터운 꼬리 분포 특성과 변동성의 군집현상(clustering)을 잘 설명하고 있다. 일반적으로 GARCH 모형의 모수는 가우스분포로부터 추출된 자료에서 최적의 성과를 보이는 로그우도함수에 대한 최우도추정법에 의하여 추정되고 있다. 그러나 1987년 소위 블랙먼데이 이후 주식 시장은 점점 더 복잡해지고 시장 변수들이 많은 잡음(noise)을 띠게 됨에 따라 변수의 분포에 대한 엄격한 가정을 요구하는 최우도추정법의 대안으로 인공지능모형에 대한 관심이 커지고 있다. 본 연구에서는 주식 시장의 주가 수익률에 나타나는 변동성의 예측 모형인 GARCH 모형의 모수추정방법으로 지능형 시스템인 Support Vector Regression 방법을 제안한다. SVR은 Vapnik에 의해 제안된 Support Vector Machines와 같은 원리를 회귀분석으로 확장한 모형으로서 Vapnik의 e-insensitive loss function을 이용하여 비선형 회귀식의 추정이 가능해졌다. SVM을 이용한 회귀식 SVR은 두터운 꼬리 분포를 보이는 주식시장의 변동성과 같은 관찰치에서도 우수한 추정 성능을 보인다. 2차 손실함수를 사용하는 기존의 최소자승법은 부최적해로서 추정 오차가 확대될 수 있다. Vapnik의 손실함수에서는 입실론 범위내의 예측 오차는 무시하고 큰 예측 오차만 손실로 처리하기 때문에 구조적 위험의 최소화를 추구하게 된다. 금융 시계열 자료를 분석한 많은 연구들은 SVR의 우수성을 보여주고 있다. 본 연구에서는 주가 변동성의 분석 대상으로서 KOSPI 200 주가지수를 사용한다. KOSPI 200 주가지수는 한국거래소에 상장된 우량주 중 거래가 활발하고 업종을 대표하는 200 종목으로 구성된 업종 대표주들의 포트폴리오이다. 분석 기간은 2010년부터 2015년까지의 6년 동안이며, 거래일의 일별 주가지수 종가 자료를 사용하였고 수익률 계산은 주가지수의 로그 차분값으로 정의하였다. KOSPI 200 주가지수의 일별 수익률 자료의 실증분석을 통해 기존의 Maximum Likelihood Estimation 방법과 본 논문이 제안하는 지능형 변동성 예측 모형의 예측성과를 비교하였다. 주가지수 수익률의 일별 자료 중 학습구간에서 대칭 GARCH 모형과 E-GARCH, GJR-GARCH와 같은 비대칭 GARCH 모형에 대하여 모수를 추정하고, 검증 구간 데이터에서 변동성 예측의 성과를 비교하였다. 전체 분석기간 1,487일 중 학습 기간은 1,187일, 검증 기간은 300일 이다. MLE 추정 방법의 실증분석 결과는 기존의 많은 연구들과 비슷한 결과를 보여주고 있다. 잔차의 분포는 정규분포보다는 Student t분포의 경우 더 우수한 모형 추정 성과를 보여주고 있어, 주가 수익률의 비정규성이 잘 반영되고 있다고 할 수 있다. MSE 기준으로, SVR 추정의 변동성 예측에서는 polynomial 커널함수를 제외하고 linear, radial 커널함수에서 MLE 보다 우수한 예측 성과를 보여주었다. DA 지표에서는 radial 커널함수를 사용한 SVR 기반의 지능형 GARCH 모형이 가장 우수한 변동성의 변화 방향에 대한 방향성 예측력을 보여주었다. 추정된 지능형 변동성 모형을 이용하여 예측된 주식 시장의 변동성 정보가 경제적 의미를 갖는지를 검토하기 위하여 지능형 변동성 거래 전략을 도출하였다. 지능형 변동성 거래 전략 IVTS의 진입규칙은 내일의 변동성이 증가할 것으로 예측되면 변동성을 매수하고 반대로 변동성의 감소가 예상되면 변동성을 매도하는 전략이다. 만약 변동성의 변화 방향이 전일과 동일하다면 기존의 변동성 매수/매도 포지션을 유지한다. 전체적으로 SVR 기반의 GARCH 모형의 투자 성과가 MLE 기반의 GARCH 모형의 투자 성과보다 높게 나타나고 있다. E-GARCH, GJR-GARCH 모형의 경우는 MLE 기반의 GARCH 모형을 이용한 IVTS 전략은 손실이 나지만 SVR 기반의 GARCH 모형을 이용한 IVTS 전략은 수익으로 나타나고 있다. SVR 커널함수에서는 선형 커널함수가 더 좋은 투자 성과를 보여주고 있다. 선형 커널함수의 경우 투자 수익률이 +526.4%를 기록하고 있다. SVR 기반의 GARCH 모형을 이용하는 IVTS 전략의 경우 승률도 51.88%부터 59.7% 사이로 높게 나타나고 있다. 옵션을 이용하는 변동성 매도전략은 방향성 거래전략과 달리 하락할 것으로 예측된 변동성의 예측 방향이 틀려 변동성이 소폭 상승하거나 변동성이 하락하지 않고 제자리에 있더라도 옵션의 시간가치 요인 때문에 전체적으로 수익이 실현될 수도 있다. 정확한 변동성의 예측은 자산의 가격 결정뿐만 아니라 실제 투자에서도 높은 수익률을 얻을 수 있기 때문에 다양한 형태의 인공신경망을 활용하여 더 나은 예측성과를 보이는 변동성 예측 모형을 개발한다면 주식시장의 투자자들에게 좋은 투자 정보를 제공하게 될 것이다.

기관지결핵의 임상상-201예에 대한 후향적 고찰 (The Clinical Features of Endobronchial Tuberculosis - A Retrospective Study on 201 Patients for 6 years)

  • 이재영;김정미;문두섭;이창화;이경상;양석철;윤호주;신동호;박성수;이정희
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권5호
    • /
    • pp.671-682
    • /
    • 1996
  • 연구배경: 결핵은 아직 우리나라에서 중요한 질병중 하나이고, 기관지결핵은 진단이 용이하지 않고, 기도협착등 합병증을 초래하여 임상적으로 중요성이 인식되어 왔으나 적절한 치료법이 확립되어 있지 않고, 각 보고자마다 내시경적 분류를 다르게 하고 있다. 이에 저자들은 1991년1월 부터 1996년 4월간 한양대학교 부속병원에서 기관지결핵으로 진단된 201예를 대상으로 기관지결핵의 임상상을 알아보고자 하였다. 방법: 1991년 1월 부터 1996년 4월 까지 한양대학교 부속병원에서 기관지내시경으로 기관지결핵으로 진단된 201예를 대상으로 임상상에 대한 후향적 분석을 하여 다음의 결과를 얻었다. 결과: 1) 총 기관지내시경을 실시한 1031예 중 기관지결핵으로 진단된 환자는 201예 (19.5%)였고, 이중 남자 55예, 여자 146예로 여자가 남자에 비해 2.7배 많았다. 연령분포는 20-29세가 61예(30.3%)로 가장 많았으며, 30-39세가 40예(19.9%), 50-59세가 27예(13.4%), 40-49세가 21예(10.4%), 15-19세가 19예(9.5%), 60-69세가 19예(9.5%), 70세 이상이 14예(7.0 %) 순이었다. 2) 증상 및 증후로는 기침 74.5%과 객담 55.2%이 가장 많았으며, 호흡곤란 28.6%, 흉통 19.8%, 발열감 17.2%, 천명음 15.6% 객혈 11.5%순이었다. 3) 방사선 소견으로는 침윤 67.7%, 허탈 43.9%, 동공형성 11.6%, 흉막삼출 7.4% 순이었고, 정상인 예도 6예(3.2%)이었다. 침범부위는 좌상폐야 39.7%, 우상폐야 36.0%, 우중폐야 24.3%, 좌하폐야 21.2%, 좌중폐야 18.5%, 우하폐야 14.8% 순이었다. 4) 폐기능 검사를 실시한 76예의 결과는 정상소견이 44.7%, 제한성 양상이 39.5%, 폐쇄성 양상이 11.8%, 혼합형 양상이 3.9% 순이었다. 5) 기관지내시경 소견으로는 건락성 물질인 백색의 가막형성의 건락성 가막형이 70예 (34.8%)로 가장 많았으며, 점막의 발적 및 부종의 점막형이 54예(26.9%), 과형성성 소견의 파형성형이 52예(25.9%), 섬유화에 의한 협착소견의 섭유화 협착형이 22예(10.9%), 그리고 미란이나 궤양의 궤양형이 3예(1.5%) 순이었다. 6) 각 검사별 양성률은 기관지세척액에서 도말항산균 양성률이 51.2%, 배양양성이 27.4%, 기관지정 조직검사에서 항산균 양성률이 36.4% 항산균이 없는 육아종소견이 13.1%, 만성 염증소견이 36.4%, 확진을 못한 경우가 14.1%였다. 건락성 가막형의 조직검사 검체에서 항산균의 발현과 기관지 세척액에서 결핵군 배양양성률이 각각 44예 중 24예(54.5%; P=0.013), 70예 중 29예(41.4 %; P=0.009)로 높게 나타났다. 결론: 젊은 여성에 있어서 일반 진해제에 잘 반응하지 않는 기침이 오랫동안 지속될시 흉부 액스선 검사가 정상이고, 객담 도말항산균 검사가 음성이더라도 기관지결핵을 의심해야 하고, 확진을 위한 기관지내시경을 실시하여야 한다. 그리고 치료에 반응이 좋지 않은 천식이나, 폐암의 발생이 높은 노년층에 있어서도 감별진단을 위하여 또한 기관지내시경을 실시하여야 한다. 향후 기관지내시경에 의한 기관지결핵의 통일된 분류 및 스테로이드의 항결핵제와의 병용이 기도협착에 미치는 효과에 대한 잘 설계된 대조군 설정의 전향적 연구가 필요하리라 생각된다.

  • PDF

시스템분석(分析)에 의(依)한 삼림수확조절(森林收穫調節)에 관(關)한 연구(硏究) (A Study on the Forest Yield Regulation by Systems Analysis)

  • 조응혁
    • 농업과학연구
    • /
    • 제4권2호
    • /
    • pp.344-390
    • /
    • 1977
  • 본(本) 연구(硏究)는 계획기간내(計劃期間內)의 재적수확량(材積收穫量)을 최대화(最大化)하고 각분기(各分期)의 수확량(收穫量)과 수확면적(收穫面積)을 일정(一定) 범위(範圍)로 제약(制約)하여 계획기간내(計劃期間內)의 보속수확(保續收穫)을 도모(圖謀)하는 동시(同時)에 후계림(後繼林)의 법정영급배치(法正令級配置)가 유도(誘導)될 수 있는 적정수확안(適正收穫案)을 선형계획법(線型計劃法)에 의하여 선정(選定)하고, 제약량(制約量)의 변화(變化)가 총수확량(總收穫量) 및 분기별(分期別) 수확량(收穫量)과 수확면적(收穫面積)에 미치는 영향(影響)을 구명(究明)하는데 목적(目的)이 있다. 서울 대학교(大學校) 농과대학(農科大學) 부속연습림중(附屬演習林中) 개벌작업급(皆伐作業級)에 속하는 219개(個) 소반(小班)을 대상(對象)으로 하였으며, 이 삼림(森林)은 영급구성면(令級構成面)에서 볼 때 유영급(幼令級) 임분(林分)이 많다는 점(點)에서 전국(全國) 삼림(森林)을 대표(代表)한다고 할 수 있다. 본(本) 연구(硏究)에서는 한 분기년수(分期年數)를 5년(年), 계획기간(計劃期間)을 10분기(分期), 1영급(令級)을 5영개(令皆)로 하였으며, 벌채영급(伐採令級)의 범위(範圍)는 5~9영급(令級)이다. 한편, 후계림(後繼林)은 현실림(現實林)이 수확(收穫)되는 즉시 조림(造林)되고, 미립목지(未立木地)는 1분기내(分期內)에 조림(造林)되며 다음 벌기(伐期)까지 충분(充分)한 입목도(立木度)가 이루어지는 것으로 전제(前提)하였다. 소반(小班)을 벌구(伐區)로 하여, 각벌구(各伐區)가 계획기간내(計劃期間內)에 벌채(伐採)될 수 있는 모든 가능(可能)한 대체수확안(代替收穫案)을 그의 영급(令級)에 따라 작성(作成)하고, 여기에 현실림(現實林)과 후계림(後繼林)의 벌기예상수확량(伐期豫想收穫量)을 대입(代入)하여 각대체안(各代替案)의 계획(計劃) 기간내(期間內) 수확량(收穫量)($V_{i,\;k}$)을 산정(算定)하였다. 이때 각벌구(各伐區)의 벌기예상수확량(伐期豫想收穫量)은 기존(旣存) 임분수확표(林分收穫表)와 산림조사부(山林調査簿) 자료(資料)를 이용(利用)하는 범위내(範圍內)에서 추정(推定)하였으며, 각벌구(各伐區)에 소속(所屬)되는 대체수확안중(代替收穫案中)에서 $V_{i,\;k}$가 가장 큰 수확안(收穫案)을 적정수확안(適正收穫案)으로 선정(選定)하였다. 우선 제약조건(制約條件)이 없을 때의 적정수확안(適正收穫案)을 선정(選定)하여 분기별(分期別) 수확량(收穫量)과 수확면적(收穫面積), 총수확량(總收穫量)을 계산(計算)한 다음, 이를 기준(基準)으로 하여 분기별(分期別) 수확량(收穫量)의 상한(上限)($V_{j-max}$)과 하한(下限)($V_{j-min}$) 및 수확면적(收穫面積)의 상한(上限)($A_{j-max}$)과 하한(下限)($A_{j-min}$)을 결정(決定)하였다. 이러한 여러가지 제약조건하(制約條件下)의 적정수확안(適正收穫案)은 LP수확조절(收穫調節)모델을 유도(誘導)하여 선정(選定)하였으며, 제약조건(制約條件) 및 벌채영급범위(伐採令級範圍)의 변화(變化)가 총수확량(總收穫量)에 미치는 영향(影響)을 분석(分析)하고자 감응도분석(感應度分析)을 실시(實施)하였다. 본(本) 연구(硏究) 결과(結果)를 요약(要約)하면 다음과 같다. 1. 제약조건(制約條件) 없이 적정수확안(適正收穫案)을 선정(選定)한 결과(結果), 수확면적(收穫面積)이 분기별(分期別)로 큰 차이(差異)를 보였다. 즉, 총수확량(總收穫量)의 68.8%가 10분기(分期)에 편재(偏在)되어 있고 6~7분기(分期)에는 전(全)혀 수확량(收穫量)이 없으며, 분기별(分期別) 수확면적(收穫面積)도 이와 유사(類似)한 경향(傾向)을 보였다. 이와 같이 분기별(分期別) 수확량(收穫量) 및 수확면적(收穫面積)에 차이(差異)가 많은 것은 현실림(現實林)의 영급구성(令級構成)과 입목축적(立木蓄積)이 대단히 불규칙(不規則)하기 때문이다. 2. 수확량(收穫量)과 수확면적(收穫面積)의 분기별(分期別) 변동폭(變動幅)을 줄이면서 계획기간내(計劃期間內)의 재적수확량(材積收穫量)을 최대화(最大化)하고자, LP수확조절(收穫調節) 모델에 의하여 $A_{min}=150ha$ $A_{max}=400ha$, $V_{min}=5,000m^3$, $V_{max}=50,000m^3$일 때의 적정수확안(適正收穫案)을 선정(選定)한 결과(結果), 대체(大體)로 5분기(分期) 이후(以後)부터 보속수확(保續收穫)과 법정영급배치(法正令級配置)가 가능(可能)하게 되었다. 3. LP수확조절(收穫調節)모델에 간벌계획(間伐計劃)을 포함(包含)시켜 최적해(最適解)를 구(求)하면, 총수확량(總收穫量)이 증가(增加)함은 물론, 간벌계획(間伐計劃)을 포함(包含)시키지 않았을 경우(境遇)에 비하여 분기별(分期別) 보속수확(保續收穫)의 실현(實現)에 유리(有利)한 적정수확안(適正收穫案)을 선정(選定)해 주는 효과(效果)가 있다. 4. 보속수확(保續收穫)과 법정영급배치(法正令級配置)가 실현(實現)될 수 있는 시기(時期)는 제약량(制約量)의 강도(强度)가 높아짐에 따라서 빨라지며, 분기별(分期別) 수확량(收穫量)은 수확면적(收穫面積)에 비하여 제약량(制約量)의 변화(變化)에 따른 평준화(平準化) 경향(傾向)이 뚜렷하고, 분기별(分期別) 수확량(收穫量)의 평준화(平準化)가 이루어지면 분기별(分期別) 수확면적(收穫面積)은 이에 종속(從屬)되어 평준화(平準化)하는 경향(傾向)이 있다. 5. 제약조건(制約條件)의 강도(强度)가 높아짐에 따라 총수확량(總收穫量)은 점감적(漸減的)으로 감소(減少)하므로 빠른 시기(時期)에 엄정보속(嚴正保續)과 엄정영급배치(嚴正令級配置)를 의도(意圖)할 수록 총수확량(總收穫量)의 손실(損失)은 그만큼 더 증가(增加)한다. 6. 같은 계획기간(計劃期間) 및 제약조건하(制約條件下)에서의 총수확량(總收穫量)은 벌채영급(伐採令級)을 낮추고, 그 범위(範圍)를 넓힐수록 증가(增加)한다. 또한 벌채영급(伐採令級) 범위(範圍)의 상한(上限)을 고정(固定)하고, 그 하한(下限)을 1영급(令級)씩 높였을 때에 총수확량(總收穫量)이 감소(減少)되는 속도(速度)는, 그 범위(範圍)의 하한(下限)을 고정(固定)하고 상한(上限)을 1영급(令級)씩 낮추었을 때의 감소(減少) 속도(速度)보다 크다. 7. 본(本) 연구(硏究)에 제시(提示)된 LP수확조절(收穫調節)모델은 영급구성(令級構成)이 복잡(複雜)한 임분(林分)에 적용(適用) 가능(可能)하며, 간벌계획(間伐計劃)을 간단히 포함(包含)시킬 수 있고, 제약량(制約量)의 변화(變化)에 따른 총수확량(總收穫量)의 손실(損失)을 쉽게 계측(計測)할 수 있는 등 여러가지 장점(長點)이 있으므로, 우리나라의 현행(現行) 삼림수확조절법(森林收穫調節法)을 보완(補完)하기 위해서도 이 기법(技法)이 유효(有效)하게 이용(利用)될 수 있을 것으로 보인다.

  • PDF

저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰 (Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration)

  • 김일수;김호신;류형기;강영직;박수영;김승찬;이귀원
    • 핵의학기술
    • /
    • 제20권1호
    • /
    • pp.32-36
    • /
    • 2016
  • 핵의학검사에서 $^{131}I$은 갑상선암 및 질환의 진단, 치료등 핵의학 검사에서 많이 사용되고 있다. $^{131}I$${\gamma}$선과 ${\beta}^-$선을 방출하여 검사와 치료를 할 수 있고, 높은 집적율과 신장을 통한 빠른 배설이 용이 하지만, $^{131}I$(364 keV)은 $^{99m}Tc$(140 keV)보다 고에너지이기 때문에 작업을 수행 시 조작 및 투여 과정에서 $^{99m}Tc$보다 술자의 피폭을 줄이기 위해 외부피폭 방어의 3요소인 거리, 시간, 차폐 중에 차폐에 주안점을 두어 $^{131}I$ 조작 시 차 폐체 착용 전과 후의 피폭선량의 차이를 비교하고자 한다. Apron(보통 Pb 0.5 mm) 착용 시 $^{99m}Tc$은 90%이상이 차폐가 되지만, $^{131}I$은 고에너지이기 때문에 차폐효과가 비교적 낮고, 고용량의 경우 산란선(2차) 및 제동방사선의 영향으로 오히려 더 피폭을 받을 수 있다. 하지만 저용량(74 MBq) 고에너지의 경우 이에 대한 특별한 보고나 Guide Line이 마련되어 있지 않아, $^{131}I$ 조작 시 Apron 착용 유무에 따른 술자의 피폭선량을 정량적으로 분석하고자 한다. 본원 핵의학과에서 2014년 6월부터 2014년 12월까지 7개월 동안 갑상선암 치료 및 진단을 위한 저용량$^{131}I$을 투여하기 위해 방문한 갑상선암 환자를 대상으로 준비과정부터 투여 시까지 연구기간 동안 갑상선, 가슴, 고환 3곳에 Apron 안쪽과 바깥쪽 각각 1개씩 총 6개의 TLD를 부착한 뒤 $^{131}I$검사 과정부터 투여 시 까지의 방사선 피폭선량을 측정하였다. 총 작업시간은 설명시간 3분, 분배시간 1분, 투여시간 1분으로 각각 1인당 5분이내로 설정하였다. TLD 위치설정은 일반적으로 피폭선량을 측정하는 가슴과 방사선 감수성이 높은 갑상선 및 고환으로 설정하였다. 준비과정은 $^{131}I$$2m{\ell}$ 주사기를 이용해 74MBq을 분배한 뒤 생리식염수와 희석해 $2m{\ell}$의 용량을 만들어 분배한다. $^{131}I$을 분배 후 환자에게 투여 시 컵에 물을 $100m{\ell}$ 담고 분배한 $^{131}I$을 희석하여 환자 1 m 정도 거리를 두고, 경구투여 한다. 그리고 경구투여 한 $2m{\ell}$ 주사기와 컵을 폐기하는 과정을 Apron과 TLD를 착용한 상태에서 시행하였다. Apron과 TLD는 방사선 피폭이 미치지 않는 보관실에 따로 보관하였고, 서울방사선 서비스에 의뢰하여 피폭선량을 측정하였다. 연구기간 동안 저용량 $^{131}I$ 검사 시 갑상선, 가슴, 고환 부위에 Apron 안과 밖d[착용한 TLD의 매월 누적선량을 인원수로 나눈 결과를 가지고, SPSS Version. 12.0K를 이용해 Wilcoxon Signed Rank Test를 사용하여 통계를 시행하였다. 그 결과 갑상선(p = 0.345), 가슴(p = 0.686), 고환(p = 0.715)은 모두 p > 0.05으로 유의한 차이가 없음을 알 수 있었다. 그리고 연구기간 동안의 총 누적선량의 변화를 백분율로 환산하였을 때, 갑상선 -23.5%, 가슴 -8.3%, 고환 19.0%로 나타났다. Wilcoxon Signed Rank Test를 사용한 결과 통계적으로 유의한 차이가 없는 것으로 나타났다(p > 0.05). 또한 7개월간의 누적선량으로 차폐율을 계산 했을 때 에는 Apron 안쪽과 바깥쪽의 피폭선량의 변화가 불규칙적으로 나타나는 결과를 보였다. 이 결과는 백분율로 표현 시 변화폭이 커보이지만, 누적 피폭선량이 소수점 이하이므로 큰 변화라고 보기 어렵다. 그러므로 고에너지 저용량 $^{131}I$ 투여 시 Apron을 착용유무와 상관없이 일정한 거리를 두고 최대한 빠른 시간 내에 투여를 종료하는 것이 피폭선량을 줄이는 데 도움이 될 것이다. 본 연구는 $^{131}I$ 투여시간을 1인당 각 5분 이내로 투여 할 수 있도록 제한하고, 거리를 1 m로 일정하게 하여 작업 할 수 있도록 하였으나 통계 시 N수가 적어서 비모수적인 방법으로 통계를 시행함으로써 정확한 결과를 얻기에 부족한 부분이 있었다. 또한 저용량 $^{131}I$ 투여 시 각 1인당 피폭선량을 직독식 선량으로 측정하지 못하고, TLD를 이용한 누적선량으로 측정한 결과 값이므로 전자선량계 및 포켓선량계를 이용한 측정이 이루어진다면 더 효과적인 결과를 얻을 수 있을 것으로 사료된다.

  • PDF