• 제목/요약/키워드: Non-Contact Test

검색결과 354건 처리시간 0.029초

구조물의 비접촉 비파괴 검사를 위한 레이저 초음파법 적용 (Laser-Ultrasonics Application for Non-Contact and Non-destructive Evaluation of Structure)

  • 김재열;송경석;양동조
    • 한국공작기계학회논문집
    • /
    • 제14권4호
    • /
    • pp.49-54
    • /
    • 2005
  • Measuring defects on the inside and on the surface of a steel structure is very important technology in order to predict the life span of the structure. In particular, a place with a high probability that it may contain defects is a welded part and it is very important to check defects in the part, absence/presence of non-uniform substances, its shape, and the location. Many non-destructive tests can be applied, but the ultrasonic flow detection test is widely used with some advantages. The ultrasonic flow detection test, however, cannot be applied when there is a problem by a contact medium between PZT and a specimen, in case of a small and complicated shape or a moving object or when the specimen is hot. In this study, to solve the problems of the contact ultrasonic flow detection test, the non-contact ultrasonic flow detection test for sending/receiving ultrasonic waves using lasers was described. I intended to develop a non-destructive detection system applying the laser application ultrasonic test to a steel structure by detecting the defects inside of and on the surface of the specimen.

Eye 패턴을 사용한 비접촉 형태의 TSV 고장 검출 기법 (TSV Fault Detection Technique using Eye Pattern Measurements Based on a Non-Contact Probing Method)

  • 김영규;한상민;안진호
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.592-597
    • /
    • 2015
  • 3D-IC is a novel semiconductor packaging technique stacking dies to improve the performance as well as the overall size. TSV is ideal for 3D-IC because it is convenient for stacking and excellent in electrical characteristics. However, due to high-density and micro-size of TSVs, they should be tested with a non-invasive manner. Thus, we introduce a TSV test method on test prober without a direct contact in this paper. A capacitive coupling effect between a probe tip and TSV is used to discriminate small TSV faults like voids and pin-holes. Through EM simulation, we can verify the size of eye-patterns with various frequencies is good for TSV test tools and non-contact test will be promising.

비접촉 전압위상 검출 기술을 이용한 무정전 절연저항 측정 방법에 관한 연구 (A Study on Measurement Technique of Insulation Resistance for Non-interrupting Inspection Using Non-contact Voltage Phase Detection Technology)

  • 이기연;문현욱;김동우;임용배;최동환;김용혁
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1106-1112
    • /
    • 2018
  • In this paper, measurement techniques are presented to test the performance of insulation without interruption if it is difficult to measure insulation resistance. Especially, non-contact voltage phase detection techniques have been developed that can be applied in environments where it is difficult to find voltage measurement locations such as component receptors. The performance verification of the non-interrupting insulation resistance measuring devices has been tested against existing products using standard calibration equipment and test jigs. The validation confirmed performance within 2 % for direct contact type and within 10 % for non-contact type. In addition, the procedure to make continuous insulation test using the equipment was proposed.

비접촉 초음파 방식의 철도레일 내부결함 검출에 관한 연구 (Research on the Non-Contact Detection of Internal Defects in a Rail using Ultrasonic Waves)

  • 한순우;조승현;김준우;허태훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.617-625
    • /
    • 2012
  • Non-contact detection of internal defects in a rail using ultrasonic waves is discussed in this paper. Cracks in a rail may be a cause of a serious railway accident such as derailment if left undetected. Concurrent rail inspection method based on ultrasonic testing using piezoelectric transducers has several limitations as it should keep physical contact with the rail. This work suggests a non-contact detection of internal defects in a rail using ElectroMagnetic Acoustic Transducers (EMAT) which can produce and measure ultrasonic waves in a rail without any couplant. The EMATs for rail inspection are designed and fabricated and their working performance is verified through a series of experiments on various types of internal defects in test rails. The effect of lift-off between the transducers and the rail on the generated signals is also discussed.

  • PDF

비접촉 ID카드 계수를 위한 자동화 시스템 개발 (Study on Development of Automation System for Non-Contact Counting of ID Card)

  • 강대화;홍준희;곽양양;이혁원
    • 한국생산제조학회지
    • /
    • 제22권4호
    • /
    • pp.652-657
    • /
    • 2013
  • In this study, we developed a counting method for non-contact ID cards using an optical fiber displacement sensor instead of the traditionally used friction counting method. The proposed method has the advantage of high speed and automated measurement. For counting non-contact ID cards, an H-type optical fiber sensor, jig part, and counting program are developed separately to build the system and adjust it. Through the experimental test results, it was confirmed that counting is possible with one type of international ID card and one type of financial security card based on ISO7810. Furthermore, by applying the proposed method to 100 ID cards 100 times repeatedly, it was confirmed that it has high accuracy and an error ratio of 0%. We experimentally demonstrated that the proposed counting method for non-contact ID cards using an optical fiber displacement sensor can perform measurements with high accuracy and high speed.

비접촉형 마그넷기어를 적용한 클린 반송장치의 개발 (Development of Non-Contact Conveyor for Clean Process by Applying Magnet Gears)

  • 오영진;노태정
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.3633-3640
    • /
    • 2010
  • 헬리컬형으로 자화된 영구자석을 이용한 비접촉 마그넷 기어를 개발하기 위하여 3차원 FEM 해석 기법을 활용하였고 마그넷 기어의 자기적 특성 해석 및 설계 요소기술을 확보하였다. 마그넷 기어를 이용한 클린 반송 컨베이어 및 회전장치의 성능평가를 위하여 class 10의 클린부스 환경에서 시험운전을 거쳐, 이송 속도, 최대 허용 토크, 클린도, 최대 이송 중량, 헌팅 유무, 소음도 등을 측정한 결과 클린도 class 10의 공정까지도 대응이 가능한 것으로 확인되었다.

적외선 열화상에 의한 숏크리트 보강사면의 비접촉 비파괴 시험 (The Non-Destructive and Non-Contact Test Using Infrared Thermal Technique on Reinforced Slopes by Shotcrete)

  • 이종영;신창건;장범수;손종철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.622-628
    • /
    • 2004
  • In general, Reinforced Slopes by Shotcrete are difficult to inspect because of stiff Slope and highly Working Area. So the Inspection Techniques are needed by the Non-contact and Non-destructive. On this Study, Appling the safety method to finding the weak zones(cavity area, dampness area, etc.) by using the Infrared Thermal Technique That is detecting the Detail Thermal Difference on the Surface of Reinforced Slopes by Shotcrete.

  • PDF

비접촉 초음파 방식의 철도레일 내부결함 검출에 관한 연구 (Research on the Non-Contact Detection of Internal Defects in a Rail Using Ultrasonic Waves)

  • 한순우;조승현;김준우;허태훈
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.1010-1019
    • /
    • 2012
  • Non-contact detection of internal defects in a rail using ultrasonic waves is discussed in this paper. Cracks in a rail may be the cause of a serious railway accident such as derailment if left undetected. Concurrent rail inspection method based on ultrasonic testing using piezoelectric transducers has several limitations as it should keep physical contact with the rail. This work suggests a non-contact detection of internal defects in a rail using ElectroMagnetic Acoustic Transducers (EMAT) which can produce and measure ultrasonic waves in a rail without any couplant. The EMATs for rail inspection are designed and fabricated and their working performance is verified through a series of experiments on various types of internal defects in test rails. The effect of lift-off between the transducers and the rail on the generated signals is also discussed.

비접촉식 설면 습윤도 측정 기구의 개발 (Development of the non contact tongue moisture measuring device)

  • 김대복;박유경;김기왕
    • 대한한의진단학회지
    • /
    • 제14권2호
    • /
    • pp.67-74
    • /
    • 2010
  • Objectives: Tongue moisture is one of major features in tongue diagnosis of Oriental Medicine. But with regard to the methods to qualify the tongue moisture level, there have been no adequate modalities to satisfy clinicians' needs. So we developed an novel device and method to quantify the tongue moisture level without contact. Methods and Materials: Ratio of saturated area to total tongue area in the image captured with a spot light at various angles was calculated. We regarded that ratio represented the moisture of tongue surface. To evaluate the performance of suggested method, we observed the correlation between conventional contact method and our method with 19 healthy subjects. Results: With comparison to conventional contact method (Schirmer test), the suggested method showed good correlation (R = 0.8602, R2 = 0.7399). Conclusion: This Method could be a convenient and robust method to evaluate tongue moisture.

CMP 후 세정용 PVA 브러쉬의 접촉압력 분포 측정 (Contact Pressure Distribution Measurement of PVA Brush for Post CMP Cleaning)

  • 유선중;김덕중
    • 반도체디스플레이기술학회지
    • /
    • 제15권4호
    • /
    • pp.73-78
    • /
    • 2016
  • Contact pressure distribution between PVA brush and semiconductor wafer was measured by developing a test setup which could simulates the post CMP cleaning process. The test set-up used thin film type pressure sensor which could measure the pressure distribution of contact area with the resolution of $15.5ea/cm^2$. As the experimental results, it was verified that there had been severe contact pressure non-uniformity along the axis of the brush and between the adjacent projections on the brush's surface. These results should be considered when developing post CMP cleaning stage or designing the PVA brush.