• 제목/요약/키워드: Non steady state flow

검색결과 98건 처리시간 0.026초

디바이스 시뮬레이션 기술을 이용한 미세 n-MOSFET의 비등온 비형형장에 있어서의 특성해석 (Simulation of Miniaturized n-MOSFET based Non-Isothermal Non-Equilibrium Transport Model)

  • 최원철
    • 한국산업융합학회 논문집
    • /
    • 제4권3호
    • /
    • pp.329-337
    • /
    • 2001
  • This simulator is developed for the analysis of a MOSFET based on Thermally Coupled Energy Transport Model(TCETM). The simulator has the ability to calculate not only stationary characteristics but also non - stationary characteristics of a MOSFET. It solves basic semiconductor devices equations including Possion equation, current continuity equations for electrons and holes, energy balance equation for electrons and heat flow equation, using finite difference method. The conventional semiconductor device simulation technique, based on the Drift-Diffusion Model (DDM), neglects the thermal and other energy-related properties of a miniaturized device. I, therefore, developed a simulator based on the Thermally Coupled Energy Transport Model (TCETM) which treats not only steady-state but also transient phenomena of such a small-size MOSFET. In particular, the present paper investigates the breakdown characteristics in transient conditions. As a result, we found that the breakdown voltage has been largely underestimated by the DDM in transient conditions.

  • PDF

2-스풀 분리배기 방식 터보팬 엔진의 성능모사 및 진단에 관한 연구 (Steady-State Performance Simulation and Engine Condition Monitoring for 2-Spool Separate Flow Type Turbofan Engine)

  • 공창덕;강명철
    • 한국항공우주학회지
    • /
    • 제31권4호
    • /
    • pp.60-68
    • /
    • 2003
  • 본 연구에서는 터보팬 엔진의 정상상태 성능모사 프로그램을 개발하고 장착조건에서 성능해석이 수행되었다. 개발프로그램의 검증을 위해 엔진 제작사의 주어진 성능자료와 비교하였다. 비교 결과 3.5%내의 오차를 나타내어 프로그램의 신뢰성을 확인할 수 있었다. 성능진단을 위해 비선형 GPA프로그램을 개발하였으며, 최적계측변수의 선정을 위한 연구를 수행하였다. 계측변수의 종류와 수가 진단의 정확성에 미치는 영향을 알아보기 위하여 비선형 GPA 프로그램은 다양한 변수를 이용하여 해석되었다. 그 결과 적절하게 선택된 계측변수는 보다 적은 계측장비로도 신뢰성 있고 경제적인 손상 탐지가 가능함을 확인하였고, 선정된 계측변수를 이용하여 고장진단 해석을 수행하였다. 해석결과 엔진의 고장부분과 손상정도를 확인할 수 있었다.

열적, 화학적 비평형 유동해석에서 내재적 시간 적분법의 비교 (Comparison of Implicit Time Integration Schemes for the Analysis of Thermal and Chemical Non-equilibrium Flow)

  • 이창호;박승오
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 추계 학술대회논문집
    • /
    • pp.42-47
    • /
    • 1999
  • In this study, we adopt the point symmetric Gauss-Seidel relaxation algorithm to obtain the steady state solution of the Navier-Stokes equations for the thermal and chemical nonequilibrium flow of air. All of the inviscid, viscous flux Jacobians and thermochemical source Jacobians are included in the implicit part Numerical simulation is performed for the thermal and chemical nonequilibrium flow over blunt body and computational results are presented. The convergence history and CPU time of the present computation are compared with the LU-SGS scheme which employs the approximate Jacobians.

  • PDF

NON-GREY RADIATIVE TRANSFER IN THE PHOTOSPHERIC CONVECTION : VALIDITY OF THE EDDINGTON APPROXIMATION

  • BACH, KIEHUNN
    • 천문학회지
    • /
    • 제49권1호
    • /
    • pp.1-8
    • /
    • 2016
  • The aim of this study is to describe the physical processes taking place in the solar photosphere. Based on 3D hydrodynamic simulations including a detailed radiation transfer scheme, we investigate thermodynamic structures and radiation fields in solar surface convection. As a starting model, the initial stratification in the outer envelope calculated using the solar calibrations in the context of the standard stellar theory. When the numerical fluid becomes thermally relaxed, the thermodynamic structure of the steady-state turbulent flow was explicitly collected. Particularly, a non-grey radiative transfer incorporating the opacity distribution function was considered in our calculations. In addition, we evaluate the classical approximations that are usually adopted in the onedimensional stellar structure models. We numerically reconfirm that radiation fields are well represented by the asymptotic characteristics of the Eddington approximation (the diffusion limit and the streaming limit). However, this classical approximation underestimates radiation energy in the shallow layers near the surface, which implies that a reliable treatment of the non-grey line opacities is crucial for the accurate description of the photospheric convection phenomenon.

타워형 태양열 발전 흡수기의 열유속에 따른 수순환 특성 연구 (Water Circulation Characteristics of a Water/Steam Receiver for Solar Power Tower System at Various Heat Fluxes)

  • 서호영;김종규;강용혁;김용찬
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.1-9
    • /
    • 2008
  • This paper describes water circulation characteristics of a water/steam receiver at various heat fluxes. The water/steam receiver for a solar tower power system is a natural circulation type. Experimental conditions of water and steam were set at a pressure of 5 bar and temperature of $151.8^{\circ}C$. The experimental device for the water/steam receiver consisted of a steam drum, upper/lower header, riser tubes, and downcomer tube. The experiments were conducted by varying heat fluxes in terms of mass flow rate in each riser tube. However, the total mass flow rate on the riser tubes was fixed at 217.4 g/s. For the uniform heat flux, while the water temperature of the steam drum and upper header were kept at steady state, the temperature of the lower header was fluctuated. For the non-uniform heat flux, while the temperature of the steam drum was kept steady state, the temperature difference increased in the right and left side of the upper header, and the temperature of the lower header was fluctuated.

다품종 제품과 전용 대기공간을 고려한 다단계 베르누이 라인을 위한 성능 모델 (Performance Models of Multi-stage Bernoulli Lines with Multiple Product and Dedicated Buffers)

  • 박경수;한준희;김우성
    • 산업경영시스템학회지
    • /
    • 제44권3호
    • /
    • pp.22-32
    • /
    • 2021
  • To meet rapidly changing market demands, manufacturers strive to increase both of productivity and diversity at the same time. As a part of those effort, they are applying flexible manufacturing systems that produce multiple types and/or options of products at a single production line. This paper studies such flexible manufacturing system with multiple types of products, multiple Bernoulli reliability machines and dedicated buffers between them for each of product types. As one of the prevalent control policies, priority based policy is applied at each machines to select the product to be processed. To analyze such system and its performance measures exactly, Markov chain models are applied. Because it is too complex to define all relative transient and its probabilities for each state, an algorithm to update transient state probability are introduced. Based on the steady state probability, some performance measures such as production rate, WIP-based measures, blocking probability and starvation probability are derived. Some system properties are also addressed. There is a property of non-conservation of flow, which means the product ratio at the input flow is not conserved at the succeeding flows. In addition, it is also found that increased buffer capacity does not guarantee improved production rate in this system.

2차원 정방형 캐비티유동장의 비정상특성 (Unsteady Characteristics of a Two-Dimensional Square Cavity Flow)

  • 이영호;최장운;도덕희
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.622-632
    • /
    • 1995
  • The present numerical study is aimed to investigate time-dependent characteristics of a two-dimensional lid-driven square cavity flow of three high Reynolds numbers, $7.5{\times}10^3$, $10^4$ and $3{\times}10^4$. A conservative convection term on irregular grids was adopted by renewing the MAC type difference schemes on regular grids. Relaxation of velocity and pressure is implemented by SOLA algorithm. In case of $Re=7.5{\times}10^3$, flow behavior converges to steady state after a transient period. But for $Re=10^4$, periodic unsteady sinusoidal fluctuation of local velocity and kinetic energy is found and continuous movements of small eddies in the secondary flow regions are also discovered. Random generation of eddies and their active migrating behavior are detected for $Re=3{\times}10^4$, resulting in complete unsteady and non-linear flow characteristics. And, an organized structure similar to a Moffat vortex is also observed from the time-mean flow patterns. Furthermore, a typoon-like vortex(TLV) appears intemittently and rotates along the separation regions and boundary layers.

  • PDF

익산 지역의 지하수 유동 모델 (Groundwater Flow Model of Igsan Area)

  • 함세영;김연기
    • 자원환경지질
    • /
    • 제22권4호
    • /
    • pp.381-393
    • /
    • 1989
  • 익산지역의 지하수 유동계를 평가하기 위한 수리지질학적 모델링이 수행되었다. 연구지역의 범위는 $790km^2$이다. 본 지역의 지질은 쥬라기의 대보화강암과 편마상화강암 그리고 선캠브리아기의 변성암으로 구성되어 있다. 채수량은 편마상화강암지역에서 가장 높으며 이는 10km내지 25m두께의 비교적 두껍게 발달된 풍화대 때문이다. 본 모델 시뮬레이션에는 콜로라도 주립대학의 유한차분법모델이 사용되었다. 본 모델은 불균일한 격자간격을 가지며, 28행과 31열로 이루어져 있다. 본 모델은 정류상태와 부정류상태에서 보정되었다.. 정류상태 시뮬레이션의 결과를1985년 9월의 수위등고선과 비교하여 투수율과 우기의 순충전률을 결정하였다. 부정류상태 시뮬레이션은 지하수 채수에 따른 대수층의 반응을 알기 위한 것이다. 부정류상태를 보정에서는 1986년5월의 수위등고선과 맞춤으로서 비산출율의 크기와 분포 그리고 건기의 채수량과 충전량을 결정하였다. 보정된 모델을 이용하여 1985년 10월부터 1995년 9월까지의 지하수채수 및 자연적인 충전에 의한 지하수위변동을 예측하여 보았다. 보정된 모델은 광역적인 지하수개발계획에 이용될 수 있다. 그러나 국부적인 지하수위변동을 예측하는데는 이용될 수 없다.

  • PDF

Magnetic Czochralski 실리콘 단결정 성장에서 열 및 유체유동과 질량전달에 미치는 비균일 자장의 효과 (Effect of non-uniform magnetic field on the thermal behavior and mass transfer in magnetohydrodynamic Czochralski crystal growth of silicon)

  • 김창녕
    • 한국결정성장학회지
    • /
    • 제8권4호
    • /
    • pp.555-562
    • /
    • 1998
  • 비균일 자장이 도가니에 인가되어 있는 상황에서 정상상태의 Czochralski 유동장과 비정상상태의 산소농도장에 대한 연구가 수치해석적인 방법으로 연구되었다. 여기에서 기준 자장의 세기가 B=0.1T, 0.2T, 0.3T의 경우에 대한 연구가 수행되었다. 가열에 의한 부력의 효과와 자유표면의 표면장력에 의한 열모세관 효과에 의하여 유발되는 자오면 유동은 비균일 자장에 의하여 차등적으로 억제되고 있다. 자자의 세기가 증가하면 자오면 유동에서 발생하는 순환류의 중심은 결정으로 접근하며, 순환류의 크기도 작아진다. 결정으로 흡수되는 산소의 세기가 클수록 낮아지며 농도분포는 균일해지는 경향을 갖는다.

  • PDF

Development of a Subchannel Analysis Code MATRA Applicable to PWRs and ALWRs

  • Yoo, Yeon-Jong;Hwang, Dae-Hyun;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.314-327
    • /
    • 1999
  • A subchannel analysis code MATRA applicable to PWRs and ALWRs has been developed to be run on an IBM PC or HP WS based on the existing CDC CYBER mainframe version of COBRA-Rf-1. This MATRA code is a thermal-hydraulic analysis code based on the subchannel approach for calculating the enthalpy and How distribution in fuel assemblies and reactor cores for both steady-state and transient conditions. HATRA has been provided with an improved structure, various functions, and models to give more convenient user environment and to enhance the code accuracy. Among them, the pressure drop model has been improved to be applied to non-square-lattice rod arrays, and the models for the lateral transport between adjacent subchannels have been improved to enhance the accuracy in predicting two-phase flow phenomena. The predictions of MATRA were compared with the experimental data on the flow and enthalpy distribution in some sample rod-bundle cases to evaluate the performance of MATRA. All the results revealed that the predictions of MATRA were better than those of COBRA-IV-I.

  • PDF