• Title/Summary/Keyword: Non point pollution source

Search Result 381, Processing Time 0.024 seconds

Application Evaluation of Best Management Practices for Agricultural Non-Point Source Pollution using Delphi Survey Method (전문가 델파이 방법을 이용한 농업 비점오염 저감 기술의 현장 적용성 조사)

  • Kim, Min-Kyeong;Jung, Goo-Bok;Kim, Min-Young;Kim, Myung-Hyun;Cho, Kwang-Jin;Choi, Soon-Kun;Hong, Seong-Chang;So, Kyu-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.2
    • /
    • pp.144-147
    • /
    • 2014
  • BACKGROUND: It is essential to prioritize the exact and clear understanding of agricultural nonpoint source pollution (NPS) controls. The realistic policies and systems should also be developed based on this understanding. Therefore, this study aimed to present agricultural Best Management Practices (BMPs) applicable for the fields based on the Delphi survey result. METHODS AND RESULTS: This study deduced the evaluation items to assess each BMP for agricultural NPS control and conducted the surveying using the Delphi method based on agricultural BMP experts. In addition, its on-the-spot application were evaluated. Considering its importance, technical, social and economic proprieties showed that political support was ranked first and followed by cost investment, labor investment, reduction effect and resident participation. The survey findings by agricultural BMP experts showed the good performance of on-the-spot application can be achieved from fertilization by soil testing, residue and green manure application and contour plowing which are applicable within a field. Agricultural BMPs, highly applicable for the fields, were the countermeasures that farmers who are the principal bodies of agricultural NPS control could be participated directly. CONCLUSION: The active participation of farmers is essential for effective control of agricultural NPS. It is necessary to establish various incentive systems.

A Study on Selection Method of Management Watershed for Total Pollution Load Control at Tributary (지류총량관리를 위한 관리유역 선정 방법에 관한 연구)

  • Hwang, Ha Sun;Lee, Sung Jun;Ryu, Jichul;Park, Ji Hyung;Kim, Yong Seok;Ahn, Ki Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.528-536
    • /
    • 2016
  • The purpose of Total Pollution Load Control at Tributary is to obtain maximum improvement effect of water quality through finding the most impaired section of water-body and establishing the proper control measure of pollutant load. This study was implemented to determine the optimal management of reach, period, condition, watershed, and pollution source and propose appropriate reduction practices using the Load duration curve (LDC) and field monitoring data. With the data of measurement, LDC analysis shows that the most impaired condition is reach V (G4~G5), E group (flow exceedance percentile 90~100%) and winter season. For this reason, winter season and low flow condition should be preferentially considered to restore water quality. The result of pollution analysis for the priority reach and period shows that agricultural nonpoint source loads from onion and garlic culture are most polluting. Therefore, it is concluded that agricultural reuse of surface effluent (storm-water runoff with non-point sources) and low impact farming that includes reducing fertilization and controlling the height of drainage outlet are efficient water quality management for this study watershed.

Effect of Plant Coverage on the Treatment Efficiency of Nitrogen and Phosphorus in Vegetative Filter Strips (식생피도가 식생여과대의 질소 및 인 처리효율에 미치는 영향)

  • Lee, Byungsoo;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.499-503
    • /
    • 2008
  • In order to control the non-point source pollution, a vegetative filter strips (VFS) was set up and the site-monitoring was performed. The objective of this study is to investigate the influence of the plant coverage on treatment efficiency of total nitrogen (T-N) and total phosphorus (T-P) using vegetative filter strips. According to the results, it seemed that the treatment efficiencies of T-N and T-P were closely related with the plant coverage ratio. The results showed that treatment efficiency of T-P average 50% at higher than 50% of the plant coverage and 20~23% at lower than 50% of the plant coverage. Also, the treatment efficiency of T-N increased with the increase of the plant coverage ratio.

Variation of Non-Point Source Pollution according to AMC Condition Using Probable Rainfall (확률강우량을 이용한 AMC 조건에 따른 비점원 오염량의 변화)

  • 안승섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.3
    • /
    • pp.76-88
    • /
    • 2000
  • AGNPS model is applied in this study to analyze the changes of non-point source pollutant according to AMC condition using probable rainfall. Probable rainfall of H-dam area by Gumber's extreme value distribution is computed through frequency analysis for each return period. 35 coarse grids are subdivided into 134 find grids of finite differential network to analyze peak flow soil loss quantity and nutrients of study area and the modified CN estimation equation shows good result about rainfall events-peak flow relationship. And as the consequence of estimation of soil loss quantity for each rainfall event soil loss quantity shows 120%-170% of actual soil loss quantity Regression analysis for the observed and calculated values of flow T-P AMC has an important effect on nutrients concentration of outflow and it if found that the excessive fertilization under AMC III condition may cause eutrophication by nutrients because the range of increase of outflow concentration appears relatively high.

  • PDF

Best Buffer Width of Riparian Buffer Zone using a Pilot with Different Plant Species for Reduction of Non-point Pollutant Loading (비점오염저감을 위한 수변완충지대의 적정 설계)

  • Kim, Sung-Won;Choi, I-Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Non-point pollution is caused by many diffusive sources, unlike a point pollution derived from industrial wastewater treatment plants or sewage treatment plants. Runoff of non-point pollutants is originated from rainfall or thawing in short period of time moving over and through the a ground surface. They cause ill effect on the quality of neighboring aquatic environment. To prevent effectively the wash off from non-point pollutant, it should be immediately reduced at the source or be treated after gathering of runoff water. This study has been carried out for the best width of riparian buffer zone. So we implemented the experiment in terms of its depth, width and kind of vegetations and calculated the reduction of pollutants loading. The experimental zone encompasses the watershed of Namhan River (Kyunggido Yangpyunggun Byungsanri). The region was divided into 5 land cover sectors : grass, reed, pussy willow, mixed(grass+pussy willow) and natural zone to compare effectiveness of vegetation. Water samples from four points have been collected in different depths. And the pollutant removal efficiency by sectors with different plant species was yielded through influent with one of each sample. And we obtained the correlation between the width of riparian buffer zone and the removal efficiency of pollutants. Using correlation result, the width of riparian buffer zones which needs to improve the water quality of river could be derived.

Analysis of Seasonal Water Pollution According to the Reuse and Treatment of Wastewater from Anyang Stream (안양천 하수처리 재이용에 따른 계절별 수질오염 분석)

  • Lee, Yang-Kyu;Hong, Chang-Sun;Lim, Kwang-Su
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.2
    • /
    • pp.41-52
    • /
    • 2013
  • Anyang Stream Restoration Movement was started from 2001 for the construction of ecological city. The facilities for reuse of treated sewerage have been used since 2003 for improvement of water quality, maintenance of water quantity, river ecological restoration, and hydrophilic space. Thus, the Anyang city has been gradually transformed to eco-friendly city after the construction of Anyang stream and Hakui stream as natural rivers. In this study, biological and chemical methods as well as ecological indicators for Anyang mainstream and major tributaries were monitored for four years in between 2008 and 2012. The water quality and the diversity of species in most of the streams were found to be good except Anyang main stream. It appears that the influence of seasonal drying stream is almost disappeared except Sammak stream. Thus, the values for BOD (Biochemical Oxygen Demand) and BIP (Biological Index of Pollution) for Anyang main stream were found to be 5.27~3.42mg/l and 4.51~5.50, respectively. This is considered to be caused by the reused water quality of treated wastewater being exceeded the design criteria or by the non-point source of contaminants around the stream. However, entire section of tributaries shows I, II grade as a good water quality.

HSPF and SWAT Modelling for Identifying Runoff Reduction Effect of Nonpoint Source Pollution by Rice Straw Mulching on Upland Crops (볏짚 피복에 의한 밭 비점오염원 유출저감효과 분석을 위한 HSPF와 SWAT 모델링)

  • Jung, Chung Gil;Ahn, So Ra;Kim, Seong Joon;Yang, Hee Jeong;Lee, Hyung Jin;Park, Geun Ae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.2
    • /
    • pp.47-57
    • /
    • 2013
  • This study is to assess the reduction of non-point source pollution loads for rice straw mulching of upland crop cultivation at a watershed scale. For Byulmi-cheon watershed (1.21 $km^2$) located in the upstream of Gyeongan-cheon, the HSPF (Hydrological Simulation Program-Fortran) and SWAT (Soil and Water Assesment Tool), physically based distributed hydrological models were applied. Before evaluation, the model was calibrated and validated using 9 rainfall events. The Nash-Sutcliffe model efficiency (NSE) for streamflow using the HSPF was 0.62~0.76 and the determination coefficient ($R^2$) for water quality (sediment, total nitrogen T-N, and total phosphorus T-P) were 0.72, 0.62, and 0.63 respectively. The NSE for streamflow using the SWAT were 0.43~0.81 and the $R^2$ for water quality (sediment, T-N, and T-P) were 0.54, 0.87, and 0.64 respectively. From the field experiment of 16 rainfall events, the rice straw cover condition reduced surface runoff average 10.0 % compared to normal surface condition. By handling infiltration capacity (INFILT) in HSPF model, the value of 16.0 mm/hr was found to reduce about 10.0 % reduction of surface runoff. For this condition, the reduction effect of sediment, T-N, and T-P loads were 87.2, 28.5, and 85.1 % respectively. By handling soil hydraulic conductivity (SOL_K) in SWAT model, the value of 111.2 mm/hr was found to reduce about 10.0 point reduction of surface runoff. For this condition, the reduction effect of sediment, T-N, and T-P loads were 80.0, 83.2, and 78.7 % respectively. The rice straw surface covering was effective for removing surface runoff dependent loads such as sediment and T-P.

A Study on Development of Management Targets and Evaluation of Target Achievement for Non-point Source Pollution Management in Saemangeum Watershed (새만금 비점오염원 관리지역에서의 목표설정 및 달성도 평가방법론 연구)

  • Kim, Eun-Jung;Park, Bae-Kyung;Kim, Yong-Seok;Rhew, Doug-Hee;Jung, Kwang-Wook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.8
    • /
    • pp.480-491
    • /
    • 2015
  • In this study, methods using LDC (Load Duration Curve) and watershed model were suggested to develope management targets and evaluate target achievement for non-point source pollution management considering watershed and runoff characteristics and possibility for achievement of target. These methods were applied for Saemangeum watershed which was designated as nonpoint source pollution management area recently. Flow duration interval of 5 to 40% was selected as flow range for management considering runoff characteristics and TP was selected as indicator for management. Management targets were developed based on scenarios for non-point source pollutant reduction of management priority areas using LDC method and HSPF model which was calibrated using 4 years data (2009~2012). In the scenario of LID, road sweeping and 50% reduction in CSOs and untreated sewage at Jeonju A20 and 30% reduction in fertilizer and 50% in livestock NPS at Mankyung C03, Dongjin A14 and KobuA14, management targets for Mangyung bridge, Dongjin bridge, Jeonju stream and Gunpo bridge were developed as TP 0.38, 0.18, 0.64 and 0.16 mg/L respectively. When TP loads at the target stations were assumed to have been reduced by a certain percentage (10%), management targets for those target stations were developed as TP 0.35, 0.17, 0.60 and 0.15 mg/L respectively. The result of this study is expected to be used as reference material for management master plan, implementation plan and implementation assessment for non-point source management area.

Evaluation of Filtration and Backwash Efficiency of Non-point Source Pollution Reduction Facility (장치형 비점오염원 저감시설의 여과 및 역세 효율 평가)

  • Yun, Sangleen;Lee, Yong-Jae;Ahn, Jae-Hwan;Choi, Won-Suk;Lee, Jungwoo;Oh, Hye-Cheol;Kim, Seog-Ku
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.664-671
    • /
    • 2017
  • Non-point source pollution is the emission source that unspecifically releases pollutants to water system from unspecific places such as cities, agricultural lands, mountains, and construction sites and its discharge path is not easily identified. Also, it is difficult to design and manage the reduction facilities for the emission quantity is primarily affected from weather conditions like rainfall. Since 2006, the significance of non-point source pollution reduction has been grown in Republic of Korea and this reinforces needs for the installation of reduction facilities. However, because the standards for the installation details and reduction efficiency are not clarified by law, people are preferring technologies that do not require particular maintenance and high expenses. The purpose of this study is to examine and maintain the efficiency of non-point source pollutants reduction facility which uses expended polypropylene as a media. The higher the depth of the media, the less range of variations in the reduction efficiency was observed and the final efficiency was also increased. When the media depth was 60 cm, the average reduction efficiency was 94% and 90% where linear velocities were 10 m/hr and 20 m/hr respectively. The results from 180 minutes operation in 10 m/hr and 20 m/hr of linear velocities were slightly different in head loss changes which were caused by media depth variations. The backwash experiments which were conducted in triplicate showed the reduction efficiency decreased as the time went on because of the media clogging. However, it was found that after the backwashing the reduction efficiency was increased as effective as the efficiency of the initial filtration.

A Study on the Application of Agricultural Nonpoint Source Pollution(AGNPS) Model using GIS and RS (GIS와 RS를 이용한 비점원오염 모형의 적용에 관한 연구)

  • Kim, Seong-Joon;Lee, Yun-Ah;Lee, Nam-Ho;Yoon, Kwang-Sik;Hong, Seong-Gu
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.4
    • /
    • pp.63-72
    • /
    • 2000
  • The objective of this study was to identify the applicability of AGNPS(Agricultural Nonpoint Source Pollution) model using RS data; Landsat TM merged by KOMPSAT EOC and GIS data. AGNPS model which is well-known distributed nonpoint source pollution model was used as the assessment tool. This model has the capability to adjust the level of pollutant load from farmstead and the fertilization level of upland field. A small agricultural watershed($4.12km^2$) which has 20 livestock farmhouses located in Gosan-myun, Ansung-gun was selected. AGNPS data were prepared by using Arc/Info, GRASS, ER-Mapper and Idrisi. Four storm events in 1999 were used for runoff calibration, and 2 storm events which were measured in hourly-base at 4 locations along the stream were used for water quality(TN, TP) calibration.

  • PDF