• Title/Summary/Keyword: Non ROI

Search Result 89, Processing Time 0.025 seconds

Automatic Defect Detection using Fuzzy Binarization and Brightness Contrast Stretching from Ceramic Images for Non-Destructive Testing (비파괴 검사를 위한 개선된 퍼지 이진화와 명암 대비 스트레칭을 이용한 세라믹 영상에서의 결함 영역 자동 검출)

  • Kim, Kwang Baek;Song, Doo Heon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.11
    • /
    • pp.2121-2127
    • /
    • 2017
  • In this paper, we propose a computer vision based automatic defect detection method from ceramic image for non-destructive testing. From region of interest of the image, we apply brightness enhancing stretching algorithm first. One of the strength of our method is that it is designed to detect defects of images obtained from various thicknesses, that is, 8, 10, 11, 16, and 22 mm. In other cases we apply histogram based binarization algorithm. However, for 8 mm case, it may have false positive cases due to weak brightness contrast between defect and noise. Thus, we apply modified fuzzy binarization algorithm for 8 mm case. From the experiment, we verify that the proposed method shows stronger result than our previous study that used Blob labelling for all five thickness cases as expected.

Machine Vision Platform for High-Precision Detection of Disease VOC Biomarkers Using Colorimetric MOF-Based Gas Sensor Array (비색 MOF 가스센서 어레이 기반 고정밀 질환 VOCs 바이오마커 검출을 위한 머신비전 플랫폼)

  • Junyeong Lee;Seungyun Oh;Dongmin Kim;Young Wung Kim;Jungseok Heo;Dae-Sik Lee
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.112-116
    • /
    • 2024
  • Gas-sensor technology for volatile organic compounds (VOC) biomarker detection offers significant advantages for noninvasive diagnostics, including rapid response time and low operational costs, exhibiting promising potential for disease diagnosis. Colorimetric gas sensors, which enable intuitive analysis of gas concentrations through changes in color, present additional benefits for the development of personal diagnostic kits. However, the traditional method of visually monitoring these sensors can limit quantitative analysis and consistency in detection threshold evaluation, potentially affecting diagnostic accuracy. To address this, we developed a machine vision platform based on metal-organic framework (MOF) for colorimetric gas sensor arrays, designed to accurately detect disease-related VOC biomarkers. This platform integrates a CMOS camera module, gas chamber, and colorimetric MOF sensor jig to quantitatively assess color changes. A specialized machine vision algorithm accurately identifies the color-change Region of Interest (ROI) from the captured images and monitors the color trends. Performance evaluation was conducted through experiments using a platform with four types of low-concentration standard gases. A limit-of-detection (LoD) at 100 ppb level was observed. This approach significantly enhances the potential for non-invasive and accurate disease diagnosis by detecting low-concentration VOC biomarkers and offers a novel diagnostic tool.

Effects of Non-combustible moxibustion on Thermography of Healthy Human Beings (비연소식(非燃燒式) 구법(灸法) 재료(材料)를 이용한 온열자극(溫熱刺戟)이 체열방사(體熱放射)에 미치는 효과)

  • Choi, Won-Jong;Kim, Jae-Hyo;Kim, Kyung-Sik;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.21 no.3
    • /
    • pp.21-38
    • /
    • 2004
  • Objectives : Moxibustion has been become very useful tool to prevent and treat various diseases with acupuncture in oriental medicine. Expecially, moxibustion combining the heat stimulation and chemical stimulation of Artemisiae Argyi has a non-invasive characteristics comparing to the other therapeutic tools. However, because the moxibustion makes the patient's skin be burn by the combustible feature of moxibustion, most of people have been scared of being scald. Methods : In this study, we have developed new non-combustible moxibustion tools in collaboration with company (Hana Medical, co. and ICURE, co.) and tested the efficacy through effects of moxibustion of Cheon-chu $(ST_{25})$ on the abdominal thermography of health subject. The non-combustible moxibustion has main characteristics of controlled heating to inhibit being scald and heat stimulation lasting over 1 hrs. Also, to induce the chemical stimulation, the bottom contacting with skin was coated by the extract of artemisiae argyi. The volunteers who participating in this study had taken rest for 20 - 30 mins in room temperature $(23-25^{\circ}C)$ before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day The thermography of abdomen including a below part of the chest was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) by time interval of 15 minutes. Results : The results showed that moxibustion of Cheon-chu $(ST_{25})$ had more potencies of changes on all the ROIs of abdominal thermography than those of control group. Also, it was observed that the quantities of thermal changes following moxibustion of Cheon-chu $(ST_{25})$ been increased significantly comparing that of control group at all the ROIs (region of interest). Observed the thermography classified by ROI, however, moxibustion of Cheon-chu $(ST_{25})$ could modulate ipsilateral specific areas concerning to the abdominal pathway of Stomach Meridian. Conclusion : These results suggest that new non-combustible moxibusion has some similarity as like as the conventional moxibustion and moxibustion of Cheon-chu $(ST_{25})$ may modulate thermal changes of abdominal areas.

  • PDF

Development of an Image Processing Algorithm for Paprika Recognition and Coordinate Information Acquisition using Stereo Vision (스테레오 영상을 이용한 파프리카 인식 및 좌표 정보 획득 영상처리 알고리즘 개발)

  • Hwa, Ji-Ho;Song, Eui-Han;Lee, Min-Young;Lee, Bong-Ki;Lee, Dae-Weon
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.210-216
    • /
    • 2015
  • Purpose of this study was a development of an image processing algorithm to recognize paprika and acquire it's 3D coordinates from stereo images to precisely control an end-effector of a paprika auto harvester. First, H and S threshold was set using HSI histogram analyze for extracting ROI(region of interest) from raw paprika cultivation images. Next, fundamental matrix of a stereo camera system was calculated to process matching between extracted ROI of corresponding images. Epipolar lines were acquired using F matrix, and $11{\times}11$ mask was used to compare pixels on the line. Distance between extracted corresponding points were calibrated using 3D coordinates of a calibration board. Non linear regression analyze was used to prove relation between each pixel disparity of corresponding points and depth(Z). Finally, the program could calculate horizontal(X), vertical(Y) directional coordinates using stereo camera's geometry. Horizontal directional coordinate's average error was 5.3mm, vertical was 18.8mm, depth was 5.4mm. Most of the error was occurred at 400~450mm of depth and distorted regions of image.

CT Based Hemoperitoneum Scoring for Clinicians: Objectifying the Severity of Splenic Injury and Recovery (CT를 이용한 혈복강의 등급: 비장 손상의 정도 및 회복의 객관화)

  • Shin, Hong Kyung;Song, Ra-Yeong;Han, Ho-Seong;Yoon, Yoo-Seok;Cho, Jai Young;Hwang, Dae Wook;Jung, Kyuwhan;Kim, Young Ki;Lee, Woo Hyung
    • Journal of Trauma and Injury
    • /
    • v.26 no.4
    • /
    • pp.273-279
    • /
    • 2013
  • Purpose: In patients with splenic trauma, Computed Tomography (CT) scan is helpful in selecting treatment options and evaluating resolution after NOM (Non-Operative Management). The purpose of this study was to suggest a CT based hemoperitoneum (HP) scoring system that can easily be used by clinicians to evaluate the severity of injury and recovery. Methods: A retrospective review of patients with splenic trauma admitted to our hospital between May 2003 and January 2013 was conducted. Patients diagnosed with isolated spleen injury who had a CT scan on admission were included. 1 or 2 points were given according to location and amount of hematoma in the CT image. Using the existing ultrasonography (US) based HP scoring system, the same method was applied to obtain our CT based HP scoring (CBHS) system, which ranges from 0 to 8 points. The CBHS system can be easily used by clinicians for a quick assessment of splenic injury. Results: Of the 39 patients meeting the inclusion criteria, 6 patients were managed operatively and 33 nonoperatively. There was a significant difference in CBHS between the OM (operative management) group and the NOM group.(p=0.03) CBHS showed correlation with Hb (hemoglobin), Hct (hematocrit), spleen injury grade(AAST), and Hounsfield unit of ROI (Region of interest). (p=0.17, p=0.18, p<0.000, p=0.02, respectively) After successful NOM with stabilized Hb level, the amount of hemoperitoneum was scored in the follow-up CT. CBHS demonstrated correlation with decreased spleen injury grade, decreased Hounsfield unit of ROI (Region of interest) (p=0.039, p=0.049, respectively), and also objectively reflected patient recovery. Conclusion: CBHS can be used as an objective and intuitive tool for clinicians in grading the severity of splenic injury by scoring the amount of hemoperitoneum, and in assessing recovery.

Korean Mistletoe Viscum album coloratum Induces Specific and Non-Specific Immune Responses in Japanese Eel Anguilla japonica

  • Choi, Sang-Hoon;Rhow, Jin-Goo;Choi, Min-Soon;Park, Sung-Woo;Park, Kwan-Ha;Yoon, Jong-Man;Park, Gyung-Il
    • Journal of Aquaculture
    • /
    • v.22 no.1
    • /
    • pp.56-62
    • /
    • 2009
  • Effects of Korean mistletoe extracts (KM-110), Viscum album coloratum on the specific and non-specific immune responses of Japanese eel Anguilla japonica were examined. The optimal concentration not showing toxicity of KM-110 was determined to $30-40{\mu}g/ml$ in vitro and $100{\mu}g$/100 g of fish in vivo. Even $1000{\mu}g$ of KM-110/100 g of fish did not show any clinical problem in fish though the levels of toxic parameters were slightly increased. In terms of antibody production, KM-110 significantly elicited more antibody production than FCA or $\beta$-glucan. $\beta$-glucan plus KM-110 group synergistically enhanced antibody production. There was no significant difference between KM-110 and KM-110 plus $\beta$-glucan group. The ROI production by head kidney (HK) leucocytes of eel injected with 500 or $1000{\mu}g$ KM-110 was significantly (P<0.05) enhanced than the control and FCA-treated group. Maximum increase in the NBT reduction value was observed in $1000{\mu}g$ KM-110 group but no significant difference was found between 500 and $1000{\mu}g$ KM group. The level of serum lysozyme activity was significantly (P<0.05) higher in the 500 and $1000{\mu}g$ KM-110- or FCA-treated group than in the control and $200{\mu}g$ KM-110 group. The phagocytic activities of HK leucocytes isolated from eel injected with 500 and $1000{\mu}g$ KM-110 were significantly (P<0.05) higher than $200{\mu}g$ KM-110 and PBS-injected control group. Korean mistletoe appeared to be a good activator of the specific and non-specific immune responses of Japanese eel.

Review of Non-invasive Interventions for Drooling Problems in Children With Cerebral Palsy: Trends and Analysis of Interventions for Drooling (신경발달장애 아동의 침흘림치료를 위한 비침습적 중재방법에 관한 고찰: 경향 및 중재방법 분석)

  • Jeon, Joo young;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.2
    • /
    • pp.37-51
    • /
    • 2021
  • Objective : The purpose of this study was to analyze non-invasive treatments and drooling assessment methods in children with cerebral palsy and developmental disabilities, who drool. Methods : This study searched two hundred papers published in 2005-2019. Forty-four papers were selected based on their abstract and title, and ten papers were finally selected following a secondary search. Results : The PEDro Scale of the selected papers was high with an average of seven points. As a result of analyzing the overall trends, the study participants were primarily patients with cerebral palsy, and recently, the therapeutic intervention of oral sensory exercise was more actively studied than behavioral modification. Studies of behavioral modification and oral sensory exercise intervention methods were found to have differences in participant age and, cognitive level, number of participants, research design, treatment time, and duration. Studies to confirming the frequency and severity of the drooling measurement method were found to be the main factor. Conclusion : This study analyzed typical behavioral modification and oral sensory exercise interventions as examples of non-invasive therapeutic interventions for children with cerebral palsy and developmental disabilities and provided information to help select appropriate therapeutic intervention methods when planning non-invasive therapy using behavioral modification and oral sensory exercise therapy.

Evaluation on the Usefulness of Filter in Sentinel Lymphoscintigraphy Using $^{99m}Tc$-Phytate (Phytate를 이용한 감시림프절 검사 시 Filter의 유용성 평가)

  • Jeong, Yeong-Hwan;Seo, Han-Kyung;Shim, Cheol-Min;Lim, Seong-Dong;Han, Dong-Hyeon;Park, Yung-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.35-39
    • /
    • 2010
  • Purpose: The aim of this study was to investigate distribution of particle size in phytate kit and compare filtered method with non-filtered method using 200 nm filter for sentinel lymphoscintigraphy (SLS). Materials and Methods: Five phytate kit of having the same available period was measured by particle size analyzer. For in-vivo experiment, $^{99m}Tc$-phytate was injected intradermally at both foot to perform lymphoscintigraphy. Imaging was acquired at 1hour after injection. Region of interest (ROI) was drawn in inguinal and background area for analysis. RAW 264.7 cells (Murine macrophage cell) were prepared for measurement of celluar uptake as a representative of macrophages. Paired t-test was performed using SPSS (SPSS Inc, USA) for statistical analysis. Results: The size of most particle in Techne phytate kit was distributed in 130~650 nm(90.5 %). In-vivo study, the ROI analysis showed similar result between filtered and non-filtered sample, and the numerical value of count/pixel were $58.3{\pm}5.97$ and $60.2{\pm}4.88$. In-vitro study, cellular uptake study also showed no difference between filtered and non-filtered sample by gamma counting. Conclusion: The present study demonstrates that there was no meaning of 200 nm filtered method for SLS using $^{99m}Tc$-phytate.

  • PDF

Comparison of Blood Glucose Level in Pancreatic Cancer on $^{18}F$-FDG PET (췌장암 환자의 양전자방출단층촬영(PET) 검사 시 혈당치와 영상에 관한 분석)

  • Oh, Shin-Hyun;Lee, Seung-Jae;Park, Hoon-Hee;Park, Yong-Sung;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.65-69
    • /
    • 2011
  • Purpose: Normal pancreas has low uptake rate in $^{18}F$-FDG PET scan. However, it is possible to diagnose malignancy of pancreatic cancer which has high uptake rate. Many studies approve a high prevalence of diabetes in pancreatic cancer and if the blood glucose level (BGL) is over the normal range, FDG uptake will be decreased and there will be inconvenience for patients from the delay time to reduce the high BGL or could cause difficulty to arrange the schedule. Therefore, we studied the relation of BGL and image quality in pancreatic cancer on PET. Materials and Methods: A hundred patients had PET scan. The prevalence of pancreatic cancer and diabetes were evaluated using SPSS ver. 17. The fasting BGL of patients were examined and sorted as diabetes mellitus (DM) group and Non-DM group. For the evaluation, patients were divided into 3 groups (Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L). The ROI was drown on Liver and Lung for the PET imaging analysis. Results: Fifty three male and forty seven female were in the patients. The average age was $60.1{\pm}13.5$. There were 36 patients (male: 22, female: 14, 36%) who had pancreatic cancer with DM. There were 15 patients who showed over 7.0 mmol/L in their fasting BGL and 85 patients who showed under 7.0 mmol/L in their fasting BGL. Among the Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L, there was not a statistical significance (p>0.05). Conclusion: The prevalence of pancreatic cancer was comparatively high in this study. If the fasting BGL was slightly over the normal BGL, we believe it will not give a severe disturbance when the patients have PET scan. Furthermore, the examination schedule doesn't need to change and the inconvenience from the delay of patients preparation will be reduced.

  • PDF

A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy (방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가)

  • Park, Ja Ram;Kim, Min Su;Kim, Jeong Mi;Chung, Hyeon Suk;Lee, Chung Hwan;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The tissue description and electron density indicated by the Computed Tomography(CT) number (also known as Hounsfield Unit) in radiotherapy are important in ensuring the accuracy of CT-based computerized radiotherapy planning. The internal metal implants, however, not only reduce the accuracy of CT number but also introduce uncertainty into tissue description, leading to development of many clinical algorithms for reducing metal artifacts. The purpose of this study was, therefore, to investigate the accuracy and the clinical applicability by analyzing date from SMART MAR (GE) used in our institution. Methode: and material: For assessment of images, the original images were obtained after forming ROIs with identical volumes by using CIRS ED phantom and inserting rods of six tissues and then non-SMART MAR and SMART MAR images were obtained and compared in terms of CT number and SD value. For determination of the difference in dose by the changes in CT number due to metal artifacts, the original images were obtained by forming PTV at two sites of CIRS ED phantom CT images with Computerized Treatment Planning (CTP system), the identical treatment plans were established for non-SMART MAR and SMART MAR images by obtaining unilateral and bilateral titanium insertion images, and mean doses, Homogeneity Index(HI), and Conformity Index(CI) for both PTVs were compared. The absorbed doses at both sites were measured by calculating the dose conversion constant (cCy/nC) from ylinder acrylic phantom, 0.125cc ionchamber, and electrometer and obtaining non-SMART MAR and SMART MAR images from images resulting from insertions of unilateral and bilateral titanium rods, and compared with point doses from CTP. Result: The results of image assessment showed that the CT number of SMART MAR images compared to those of non-SMART MAR images were more close to those of original images, and the SD decreased more in SMART compared to non-SMART ones. The results of dose determinations showed that the mean doses, HI and CI of non-SMART MAR images compared to those of SMART MAR images were more close to those of original images, however the differences did not reach statistical significance. The results of absorbed dose measurement showed that the difference between actual absorbed dose and point dose on CTP in absorbed dose were 2.69 and 3.63 % in non-SMRT MAR images, however decreased to 0.56 and 0.68 %, respectively in SMART MAR images. Conclusion: The application of SMART MAR in CT images from patients with metal implants improved quality of images, being demonstrated by improvement in accuracy of CT number and decrease in SD, therefore it is considered that this method is useful in dose calculation and forming contour between tumor and normal tissues.

  • PDF