• Title/Summary/Keyword: Non Point Source

Search Result 722, Processing Time 0.031 seconds

Scenario-Based Exposure Risk Assessment of Molinate in a Paddy Plot ; (2) Exposure Risk Assessment (시나리오별 논에서의 molinate 노출위험도 분석: (2) 노출위험도 평가)

  • Park, Ki-Jung;Chung, Sang-Ok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.4
    • /
    • pp.17-24
    • /
    • 2008
  • Exposure risk assessment of pesticide molinate using the RICEWQ model in a rice paddy plot was performed to observe the effects of various water and pesticide management scenarios. Several scenarios were developed to represent the specific water and pesticide management practices of rice cultivation in Korea. The results of the scenario analysis using the RICEWQ model simulation from the previous studies were analysed. The molinate risk for aquatic organisms is evaluated by the ratio of the predicted environmental concentration(PEC) and the predicted no-effect concentration(PNEC). The results showed that the no-effect periods for aquatic organisms for the deep, shallow and very shallow irrigation conditions were 33.3, 28.9 and 25.6 DATs for the lable rate application and 36.4, 33.7 and 30.8 DATs for the double lable rate application, respectively. The higher application rate showed greater exposure risk to the aquatic organisms. Based on this study, the withholding period of molinate practiced in Korea, that is 3 to 4 DATs, must be much longer. The results of this study can be used for the non-point source pollution control and environmental policy making regarding pesticides.

An Algorithm for Leak Locating using Coupled Vibration of Pipe-Fluid (배관-유체 연성진동을 이용한 누수지점 탐지 알고리듬 개발 연구)

  • Lee, Young-Sup;Yoon, Dong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.798-803
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband sound from a leak location and this sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than 300m.

  • PDF

Landscape Structure and Relationship between Water Quality and Land Use Pattern in the Watershed of the Wangsuk River in Gyunggi-do Korea

  • Lee, Chang-Seok;Lee, An-Na;You, Young-Han
    • The Korean Journal of Ecology
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2001
  • Land use pattern in the Wangsuk river watershed was investigated on the bases of physiognomic vegetation maps made from the aerial photograph interpretation and field check. Landscape structure was analyzed using a GIS program supported by ArcView. Landscape structure depended on the geographical position of the river, such as the upper, middle and lower river. Watersheds of the upper and middle rivers were dominated by forests composed of secondary forest and plantation. But agricultural fields dominated that of the middle and lower river. Urban area and agricultural fields increased in from the upper toward the lower river watersheds. In addition to, a transformation of agricultural pattern into an institutional agriculture was characteristic in the middle and lower river basins. Water qualities of the Wangsuk river were usually better in the order of the upper, middle, and lower river, but they were fluctuated according to the site. Such fluctuation would due to self-purification of the river and land use pattern of the watershed as the non-point source. In this viewpoint, a strategy to manage the water quality in the level of watershed is urgently required.

  • PDF

Design and Implementation of a Current-balancing Circuit for LED Security Lights

  • Jung, Kwang-Hyun;Yoo, Jin-Wan;Park, Chong-Yeun
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.869-877
    • /
    • 2012
  • This paper presents a current-balancing circuit for security lights that uses parallel-connected LEDs. The parallel connection of LEDs causes current differences between the LED strings because of characteristic deviations. These differences can reduce the lifespan of a particular point of LEDs by thermal spotting. They can also cause non-uniform luminance of the lighting device. Among the different methods for solving these problems, the method using current-balancing transformers makes it easy to compensate for current differences and it has a simple circuitry. However, while the balancing transformer has been applied to AC light sources, LEDs operate on a DC source, so the driving circuitry and the design method have to be changed and their performances must be verified. Thus in this paper, a design method of the balancing transformer network and the driving circuitry for LEDs is proposed. The proposed design method could have a smaller size than the conventional design method. The proposed circuitry is applied to three types of 100-watt LED security lights, which use different LEDs. Experimental results are presented to verify the performance of the designed driving circuits.

A Study of Computer Models Used in Environmental Impact Assessment II : Hydrologic and Hydraulic Models (환경영향평가에 사용되는 컴퓨터 모델에 관한 연구 II : 수리수문 모델)

  • Park, Seok-Soon;Na, Eun-Hye
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.25-37
    • /
    • 2000
  • This paper presents a study of hydrological and hydraulic model applications in environmental impact statements which were submitted during recent years in Korea. In many cases (almost 70 %), the hydrological and hydraulic changes were neglected from the impact identification processes, even if the proposed actions would cause significant impacts on those environmental items. In most cases where the hydrological and hydraulic impacts were predicted, simple equations were used as an impact prediction tool. Computer models were used in very few cases(5%). Even in these few cases, models were improperly applied and thus the predicted impacts would not be reliable. The improper applications and the impact neglections are attributed to the fact that there are no available model application guidelines as well as no requirements by the review agency. The effects of mitigation measures were not analyzed in most cases. Again, these can be attributed to no formal guidelines available for impact predictions until now. A brief guideline is presented in this paper. This study suggested that the model application should be required and guided in detail by the review agency. It is also suggested that the hydrological and hydraulic items shoud be integrated with the water quality predictions in future, since the non-point source pollution runoff is based on the hydrologic phenomena and the water quality reactions on the hydraulic nature.

  • PDF

A Study of Non-point Source Reduction Efficiency by Constructed Wetland installed in Flood Pumping Station (빗물펌프장에 설치된 인공습지의 비점오염원 저감효율 연구)

  • Chun, Suk-Young;Kim, Ji-Tae;Lee, Il-Kook;Chang, Soon-Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.1
    • /
    • pp.67-74
    • /
    • 2014
  • The aim of this study was evaluated the effects of total rainfall, rainfall intensity and antecedent dry days and identify the correlation analysis with the EMC removal efficiency, in order to provide an understanding of the operation and maintenance factors of constructed wetland in flood pumping station. This study was conducted total of 20 monitoring in a catchment(326.2 ha) of constructed wetland in Ga-un flood pumping station located at the downstream of the Wang-suk stream. The determined EMC removal efficiencies were $36.04{\pm}9.45%$ for BOD, $38.50{\pm}13.50%$ for $COD_{Mn}$, $34.34{\pm}13.05%$ for TN and $34.22{\pm}14.27%$ for TP, respectively. These results showed that the pollutants concentration and EMC were reduced while passing through the constructed wetland. In the correlation analysis, the highly correlations with EMC removal efficiency of BOD and $COD_{Mn}$ were observed for total rainfall and rainfall intensity (P<0.05). However, the correlations were not found with TN and TP for rainfall variables.

Assessment of Water Quality using Multivariate Statistical Techniques: A Case Study of the Nakdong River Basin, Korea

  • Park, Seongmook;Kazama, Futaba;Lee, Shunhwa
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.197-203
    • /
    • 2014
  • This study estimated spatial and seasonal variation of water quality to understand characteristics of Nakdong river basin, Korea. All together 11 parameters (discharge, water temperature, dissolved oxygen, 5-day biochemical oxygen demand, chemical oxygen demand, pH, suspended solids, electrical conductivity, total nitrogen, total phosphorus, and total organic carbon) at 22 different sites for the period of 2003-2011 were analyzed using multivariate statistical techniques (cluster analysis, principal component analysis and factor analysis). Hierarchical cluster analysis grouped whole river basin into three zones, i.e., relatively less polluted (LP), medium polluted (MP) and highly polluted (HP) based on similarity of water quality characteristics. The results of factor analysis/principal component analysis explained up to 83.0%, 81.7% and 82.7% of total variance in water quality data of LP, MP, and HP zones, respectively. The rotated components of PCA obtained from factor analysis indicate that the parameters responsible for water quality variations were mainly related to discharge and total pollution loads (non-point pollution source) in LP, MP and HP areas; organic and nutrient pollution in LP and HP zones; and temperature, DO and TN in LP zone. This study demonstrates the usefulness of multivariate statistical techniques for analysis and interpretation of multi-parameter, multi-location and multi-year data sets.

An Estimation of NPS Pollutant Loads using the Correlation between Storm Water Runoff and Pollutant Discharge in a Small Urban Drainage Basin

  • Shin, Hyun-Suk;Yoon, Yong-Nam
    • Korean Journal of Hydrosciences
    • /
    • v.5
    • /
    • pp.99-114
    • /
    • 1994
  • Three purposes of this study are as follows : The first was the development of the extension method for the limited data observed in an urban drainage basin. The second was the analysis of the correlation between storm water runoff and NPS(non-point source) Pollutant discharge. The last was the calculation of the monthly and annual specific NPS loads using the established correlation. The selected model was the SWMM(Storm Water Management Model) developed by the US EPA(Environmental Protection Agency). As a result of this study, the best correlation between storm water runoff and NPS pollutants discharge was produced by the nonlinear correlation between runoff rate(mm/hr) and specific loads rate(kg/ha) for all pollutants studied : SS, COD, BOD, and TN. The best correlation through the analysis based on evently total mass was made by the linear correlation between the by the nonlinear correlation for CASE2. The NPS annual specific loads for the urban basin studed were 4,993 kg/ha/year for SS, 775 kg/ha/year for BOD, 3,094 kg/ha/year for COD, 257 kg/ha/year for TN, respectively. And the proportion of the NPS annual specific loads to the total annual specific loads were 41 % for SS, 13 % for BOD, 29 % for COD, and 21 % for TN.

  • PDF

GIS AND WEB-BASED DSS FOR PRELIMINARY TMDL DEVELOPMENT

  • Choi, Jin-Yong;Bernard A. Engel;Yoon, Kwang-Sik
    • Water Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.19-30
    • /
    • 2003
  • TMDL development and implementation have great potential fur use in efforts to improve water quality management, but the TMDL approach still has several difficulties to overcome in terms of cost, time requirements, and suitable methodologies. A well-defined prioritization approach for identifying watersheds of concern among several tar-get locations that would benefit from TMDL development and implementation, based on a simple screening approach, could be a major step in solving some of these difficulties. Therefore, a web-based decision support system (DSS) was developed to help identify areas within watersheds that might be priority areas for TMDL development. The DSS includes a graphical user interface based on the HTML protocol, hydrological models, databases, and geographic information system (GIS) capabilities. The DSS has a hydrological model that can estimate non-point source pollution loading based on over 30 years of daily direct runoff using the curve number method and pollutant event mean concentration data. The DSS provides comprehensive output analysis tools using charts and tables, and also provides probability analysis and best management practice cost estimation. In conclusion, the DSS is a simple, affordable tool for the preliminary study of TMDL development via the Internet, and the DSS web site can also be used as an information web server for education related to TMDL.

  • PDF

Status of the Copper as a Priority Water Pollutant and Management in Korea (특정수질유해물질 구리(Cu)의 수계에서의 현황 및 관리방향)

  • Kim, Youngchul
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.440-447
    • /
    • 2007
  • This paper is dealing with recent hot issues related with copper toxicity and its criteria, which was caused by a new government policy relocating some industries discharging priority-water quality pollutants from the watershed of Han River to other regions. Author is not interested in arguments between two sides of anti- and pro-policy but would like to go over status of copper pollution and its management and regulatory policy in Korea. From the data of published Research Journals and Reports, it can be concluded that copper is very common metal not only in the effluent from publically owned wastewater treatment plants, but also as a non-point source pollutant in the rainfall runoff. In addition, there have been very few studies personal interests, not by National Fund Basis. In order to enforce a new regulation, national-wide macro and micro-mass balance work of heavy metals should be performed in advance. In particular, background concentration and measurement errors have to be clearly defined before a new standard or criteria is established. The new standard has to be acceptable in terms of the best available technology and cost.