• Title/Summary/Keyword: Non Condensing Gas

Search Result 11, Processing Time 0.027 seconds

Thermodynamic analysis and economical optimization on various configuration of Gas Turbine Combined Cycle Power Plants (다양한 구성의 가스터빈 복합화력발전소에 대한 열역학적 해석과 경제적 최적화 연구)

  • Kim, Seungjin;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.225-228
    • /
    • 2012
  • Thermodynamic and economic analysis on various type of gas turbine combined cycle power plants was presented to build up the criteria for optimization of power plants. The efficiency considered about energy level difference between electricity and heat was introduced. The efficiency on power and heat generation of power plants whose have different purpose was estimated and power generation costs on various type of combined heat and power plants : fired/unfired, condensing/non-condensing mode, single/double pressure HRSG.

  • PDF

Characterization of Carbon Black and Oil from Positive Process of movable disc type for Waste Tires Pyrolysis (디스크 이동식 폐타이어 열분해 실증 설비로부터 생성된 Carbon Black, Oil의 특성 분석)

  • Ha, Hyun-Jung;Kim, Seong-Yeon;Kim, Ki-Kyeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.483-486
    • /
    • 2008
  • 본 연구에서는 디스크 이동식 열분해 실증 설비를 이용하여 폐타이어 열분해 반응을 수행하였고, 생성된 열분해 생성물들의 특성을 분석하였다. 폐타이어 열분해 반응은 약 $550^{\circ}C$에서 90분간 진행되었고, 반응 결과 Recovered Oil, Carbon Black, Non Condensing Gas(NC Gas)가 생성되었다. 폐타이어 열분해 생성물의 수율은 Recovered Oil $40{\sim}50%$, Carbon Black 30$\sim$35%, NC Gas 10$\sim$15%, Steel 10$\sim$15%로 나타났다. 폐타이어 열분해 반응 후 생성된 Recovered Oil은 비점 및 특성 분석 결과 상업용 중유와 비슷한 성질을 나타냈고, 폐타이어 열분해 반응의 또 다른 생성물인 Carbon Black은 특성 분석 결과 고정 탄소 비율이 낮은 반면 회분과 휘발분의 비율이 높아 상업용으로 사용하기 위해서는 적절한 정제 과정이 필요함을 알 수 있었다.열분해 과정 중에 생성된NC Gas는 GC/MS를 이용하여 성분 분석을 수행한 결과, $CO_2$, $CH_4$를 비롯하여 주로 탄화수소류로 이루어졌으며, 대부분이 연료 가스로 구성되어 있어 열분해 반응의 열원으로서 사용이 가능하였다.

  • PDF

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

Performance Evaluation of Combined Heat and Power Plant Configurations -Thermodynamic Performance and Simplified Cost Analysis (열병합 발전소의 구성안별 성능 평가 방안 - 플랜트 열성능 및 단순화 발전단가 분석)

  • Kim, Seungjin;Choi, Sangmin
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2013
  • Thermodynamic and economic analyses of various types of gas turbine combined cycle power plants have been performed to establish criteria for optimization of power plants. The concept of efficiency, in terms of the difference in energy levels of electricity and heat, was introduced. The efficiency of power and heat generation by power plants with other purposes was estimated, and power generation costs were figured out for various types of combined heat and power plants(i.e., fired and unfired, condensing and non-condensing modes, single or double pressure HRSG).

Analyses of International Standard Problem ISP-47 TOSQAN experiment with containmentFOAM

  • Myeong-Seon Chae;Stephan Kelm;Domenico Paladino
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.611-623
    • /
    • 2024
  • The ISP-47 TOSQAN experiment was analyzed with containmentFOAM which is an open-source CFD code based on OpenFOAM. The containment phenomena taking place during the experiment are gas mixing, stratification and wall condensation in a mixture composed of steam and non-condensable gas. The k-ω SST turbulence model was adopted with buoyancy turbulence models. The wall condensation model used is based on the diffusion layer approach. We have simulated the full TOSQAN experiment which had a duration 20000 s. Sensitivity studies were conducted for the buoyancy turbulence models with SGDH and GGDH and there were not significant differences. All the main features of the experiments namely pressure history, temperature, velocity and gas species evolution were well predicted by containemntFOAM. The simulation results confirmed the formation of two large flow stream circulations and a mixing zone resulting by the combined effects of the condensation flow and natural convection flow. It was found that the natural convection in lower region of the vessel devotes to maintain two large circulations and to be varied the height of the mixing zone as result of sensitivity analysis of non-condensing wall temperature. The computational results obtained with the 2D mesh grid approach were comparable to the experimental results.

Influence of Operating Conditions on the Performance of a Oxy-fuel Combustion Reference Cycle (순산소 연소 기본 사이클의 작동조건 변화에 따른 성능해석)

  • Park, Byung-Chul;Sohn, Jeong-Lak;Kim, Tong-Seop;Ahn, Kook-Young;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.4
    • /
    • pp.30-36
    • /
    • 2009
  • Recently, there has been growing interest in the oxyfuel combustion cycle since it enables high-purity $CO_2 capture with high$ efficiency. However, the oxyfuel combustion cycle has some important issues regarding to its performance such as the requirement of water recirculation to decrease a turbine inlet temperature and proper combustion to enhance cycle efficiency. Also, Some of water vapour remain not condensed at condenser outlet because cycle working fluid contains non-condensable gas, i.e., $CO_2$. The purpose of the present study is to analyze performance characteristics of the oxyfuel combustion cycle with different turbine inlet temperatures, combustion pressures and condenser pressure. It is expected that increasing the turbine inlet temperature improves cycle efficiency, on the other hand, the combustion pressure has specific value to display highest cycle efficiency. And increasing condensing pressure improves water vapour condensing rate.

Study on Operation Characteristics of Waste Tire Pyrolysis Demonstration Plant with Moving Disk Tube Reactor System (디스크 이동식 폐타이어 열분해 실증 설비의 운전 특성 고찰)

  • Ha, Hyun-Jung;Kim, Seong-Yeon;Kim, Ki-Kyeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.157-160
    • /
    • 2008
  • 본 연구에서는 디스크 이동식 폐타이어 열분해 실증 설비(10톤/일)를 설계, 제작 그리고 시운전을 통하여 열분해 설비의 안정적인 연속 운전이 가능함을 확인하였다. 시운전 결과 반응기 내부 온도는 $500{\sim}600^{\circ}C$, 내부 압력은 $-80{\sim}-100mmHg$, 체류시간은 $60{\sim}90min$ 범위에서 안정적인 열분해가 일어났다. 또한 이번 과제 수행을 통해NC 가스의 연소기를 개발 적용하여 NC 가스의 열분해 열원으로 사용 가능성을 확인하였으며, NC 가스 연소 시 대기 측정을 통하여 규제치도 만족함을 확인할 수 있었다. 지금까지 나온 결과는 장기 연속 운전과 scale-up을 위한 기초 자료가 될 것이다.

  • PDF

Convection and Non-Gray Radiation in a Tube with Circumferential Fins and Circular Disks (배플이 있는 튜브 내에서의 대류와 비회복사)

  • Lee, Jae-Yong;Seo, Tae-Beom;Kim, Chong-Bo
    • Solar Energy
    • /
    • v.19 no.1
    • /
    • pp.67-75
    • /
    • 1999
  • The effect of radiation heat transfer was investigated under various operating conditions in a circular tube with circumferential fins and circular disks. Using a finite volume technique(FVM) for steady laminar flow, the governing equations were derived in order to simulate the flow and temperature fields. In addition, the P-1 approximation and the Weighted Sum of Gray Gas Model(WSGGM) were used for the radiation transport equation(RTE). From the results, radiation heat transfer was significant compared to convection heat transfer. These results will be applied to the design of the heat exchanger for a condensing bolier, which were developed for domestic heating.

  • PDF

Development of Heat-treatment Furnace with Maximum Uniform Zone using Gas-phase Condensing Heat Exchange (기상응축 열교환을 이용한 고정밀 등온 가열로 개발)

  • Hong, Hyun-Seon;Kong, Man-Seek;Kang, Hwan-Kook
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.3
    • /
    • pp.162-168
    • /
    • 2009
  • A horizontal tube furnace with a wide uniform-temperature zone was developed using isothermal characteristics of a heat pipe. The heat pipe heating system consists of a concentric annular shaped stainless-steel container, sodium as a working fluid and a screen mesh wick structure. The performance test of the heat pipe revealed that temperature changes along seven consecutive positions of the heat pipe outer wall were less than${\pm}0.1^{\circ}C$, thereby ensuring the high isothermal property. The isothermal property of the heat pipe-adapted tube fumace was investigated and compared to a conventional non-heat pipe type tube furnace. The temperature distribution measurement showed that the uniform temperature zone, in which temperature change is less than${\pm}$1$^{\circ}$C, of the heat pipe employed tube furnace system was about three times longer compared to the conventional tube furnace system.

Performance Analysis of CHP(Combined Heat and Power) for Various Ambient Conditions (외기조건변화에 따른 CHP 성능 해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon;Kim, Nam-Jin;Lim, Kyung-Bum;Seo, Young-Ho;Kim, Ki-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3353-3359
    • /
    • 2011
  • The co-generation system consisted of gas a turbine, a steam turbine, heat recovery steam generator and a heat exchangers for district heating was investigated in the present study. A back-pressure steam turbine (non-condensing type) was used. A partial load analysis according to the outdoor temperature in winter was conducted and optimal thermal load and power conditions was examined using the commercial computing software Thermoflex. As a result, under a constant thermal load, the power outputs of gas turbine and overall system increased as an outdoor temperature decreased. On the other hand, the reduction in exhaust gas temperature led to the decrease in output of steam turbine. Considering the portion of gas turbine in overall system in terms of the power output, it can be known that the tendency in power output of overall system was similar to that of the gas turbine.