• Title/Summary/Keyword: Noise-reduced

Search Result 1,751, Processing Time 0.032 seconds

Vibro-acoustic Design and Development of a Low-noise Hydraulic Breaker (저소음형 유압 브레이커의 음향-진동 설계 및 개발)

  • 이종화;이정권;박성하;하태광;임종혁
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.5
    • /
    • pp.148-155
    • /
    • 2001
  • Hydraulic breaker is currently used for many civil engineering areas owing to the ease of changing the tooling mechanism. However, due to a high noise level, it has been one of notorious sources of environmental noise and the prevailing environmental concerns force the manufacturers to reduce the radiated noise levee during operations. To comply with such concerns, the present study is focused on designing and developing a low-noise hydraulic breaker For this purpose, sound sources are identified and relative contributions are rated. Acoustic enclosure. sealing systems, and low-nolle type chisel have been developed and applied to the actual machine. As a result, the radiated noise from the developed low-noose hydraulic breaker is reduced more than 13 dB(A) In comparison with the conventional hydraulic bleaker.

  • PDF

An Experimental Study on the Impedance of the Machinery Foundation and the Cabin Noise in Cruise Ship (여객선 객실소음과 장비 받침대 임피던스에 관한 실험적 연구)

  • Kim, Kuk-Su;Kim, Nho-Seong;Rhee, Wook;Kwak, Dong-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.513-518
    • /
    • 2011
  • In cruise ships, it is inevitable to arrange the cabins near by the noisy areas, such as ventilation fan, HVAC machinery and funnel casing etc. The noise is propagated to the cabins by way of mount, foundation and deck. The transmitted noise to cabin is affected by mount and foundation structure. It is well-known that most of the structure-borne noise can be reduced by the flexible mount. However, when the foundation of machinery is designed inappropriately, it can make noise problems in cabins. In this paper, the effect of foundation on noise reduction is studied through the numerical analysis and mock up test. The dynamic performance of foundation is investigated from the viewpoint of the impedance and noise reduction in cabin.

  • PDF

A Study on the Prediction of the Radial Noise Generated by Structural Vibration of the Fuel Tank in LPG Vehicle (LPG차량에 장착된 연료탱크의 구조 진동으로 인한 방사소음 예측에 관한 연구)

  • Kim, Tae-Yong;Kim, Sung-Jong;Lee, Dae-Yup;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.2 s.119
    • /
    • pp.136-142
    • /
    • 2007
  • Fuel tank noise of the LPG vehicle is getting more important for reduction of vehicle noise, because major noise of the vehicle was reduced. Therefore, in this paper, Fuel tank noise and vibration are measured, then the modal analysis is applied for prediction of fuel tank noise. To predict fuel tank noise, various methods are applied by using FEM and BEM techniques.

Evaluation of indoor refrigerator noise in steady-state condition (주거 공간내 냉장고 소음의 정상상태 평가)

  • Lee, Chung-Hwa;Jeong, Jeong-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.790-795
    • /
    • 2004
  • The characteristics of refrigerator noise recorded in anechoic chamber was investigated in condition of a the real living room and a kitchen. To predict the noise propagation in an apartment unit, room acoustic simulation software was used. It was found that the noise level in the real living room was $4\sim8dB$ higher than in the anechoic chamber. When a noise barrier and absorption materials were used on the rear wall and floor, the noise level reduced up to $3\sim4dB$. In addition, when the subjective evaluation of auralized refrigerator noise was undertaken using headphone, it was revealed that 21dB (A) is the allowable sound pressure level of 95% satisfaction.

  • PDF

A Study on the Method for Reducing the Noise of the Progressive Multi-Leaf Spring (Progressive Multi-Leaf Spring의 소음저감 방안에 관한 연구)

  • Kim, Sung-Soo;Moon, Won-Kyu;Yoo, Young-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.636-642
    • /
    • 2000
  • A method for reducing the contact noise of the Progressive Multi-Leaf Spring was investigated. It was found that the contact noise between the main and the help springs is the main source of the noise through our experiments. The conclusions from our experiments were compared with those from our numerical analysis by use of ABAQUS. The main parameters for the unexpected noise in the leaf spring were investigated through structural analysis to make describing noise generation. The contact process between the two leaves is examined by numerical calculations by ABAQUS. The noise produced by the leaf spring could be dramatically reduced by changing the shape of help spring so as to remove a translational jump of the contact point between the main and the help springs. Even with the help spring of the new proposed shape the stiffness of the whole spring did not change much.

  • PDF

A design of Audio SMPS Using Noise Reduction Techniques (노이즈 감쇠 기법을 적용한 오디오 전원용 SMPS 설계)

  • Lee, Dong-Geun;Jo, Jung-Yol
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1175-1176
    • /
    • 2008
  • This paper deals with the study on the development of Audio SMPS with reduced noise. The noise defined here is in the range between 20 - 20 kHz frequency that a human can listen. We proposed a design method for Audio SMPS, which reduce noise and raise audio performances. This was achieved by new electronic elements, grounding, pattern, and shielding methods.

  • PDF

An Implementation of Noise Canceler by using FIR Filter on DSP (DSP에서 FIR 필터를 이용한 잡음 제거기 구현)

  • 김정국;이충근
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.357-360
    • /
    • 2000
  • In this paper, we want to implement a noise canceller by using FIR filter on DSP(Digital Signal Processor). The FIR filter was designed by Blackman window together with desired band width and center frequency. We adopt Motorola DSP56002 and Crystal CS4215 (A/D and D/A converter) for our purpose. we generate input sinusoidal signals and noises by differential equations and pseudo random sequences on DSP also. The input signal including sinusoidal and noise passes through the FIR filter. The FIR filer output is a sinusoidal signal with noise reduced.

  • PDF

Experimental Study of Vibration and Noise Reduction Effect of Railroad Vibration Isolator (철도레일 방진 체결장치의 진동 및 소음 저감 효과에 관한 실험적 연구)

  • Lee, Jang-Hyun;Kim, Tae-Eon;Lee, Seong-Choon;Chon, Ik-Pom
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1373-1378
    • /
    • 2000
  • Vibration caused by railroad vehicle including subway train running raises a lot of problems to the neighboring buildings. Therefore lots of methods to isolate the railway vibration have been studied and practically applied to sites. As one of them, specially designed vibration isolation device was installed in the some section of Seoul subway. This device is installed between the rail and track slab. Because the process of installation is relatively simple, this method can be applied to the existing railways in servicing. We measured the vibration and noise to check the effectiveness of this device before and after the installation. The result showed that the vibration level of the slab and platform was reduced to 7 - 10 dB. Expecially high frequency component was reduced to a large amount. From this result, we can conclude that these kind of devices are useful to the reduction of the railroad vibration, expecially the high frequency vibration which can cause structure born noise.

  • PDF

Acoustic Noise Characteristics Improvement of Solenoid Valve by the Shading Coil Application (쉐이딩 코일의 추가에 의한 솔레노이드 밸브의 소음 특성 개선)

  • Jung, Tae-Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1175-1180
    • /
    • 2008
  • Recently agriculture has been intelligenced and automatized because the number of agricultural population is reduced, and the various agricultural machine is developed and utilized actively, In these agricultural automation system, the solenoid valve is widely used for the supply of water and fertilizer to the plant and soil. In this solenoid valve system, AC excitation solenoid valve is widely used because of economic merit and simple system scheme. However, the instantaneous chattering vibration and noise of plunger caused by the alternative MMF variation is very important performance characteristics. In order to reduce vibration the DC excitation solenoid valve is sometimes applied for the high-end applications. In this case, the control circuit is essential to control DC excitation current. It may causes the cost increase and system complexity and it is not suitable for the outdoor agricultural machine. In this paper, the electromagnetic structural improvement of AC solenoid valve is studied to reduce the dynamic vibration and noise. As an economical solution, the shading coil is additionally implemented to the conventional solenoid valve. As a result of this study, the vibration and acoustic noise is largely reduced by the compensating MMF of shading coil and it is verified by the test of prototype.

Low Noise Vacuum Cleaner Design (저소음 청소기 개발)

  • Joo, Jae-Man;Lee, Jun-Hwa;Hong, Seun-Gee;Oh, Jang-Keun;Song, Hwa-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.939-942
    • /
    • 2007
  • Vacuum cleaner is a close life product that can remove various dusts from our surroundings. However well vacuum cleaner clean our environments, many people are looking away from it, due to its loud noise. Its noise causes a big trouble in the usual life, for example, catch calls, TV watching and discussing etc. To reduce these inconveniences, noise reduction methods and systematic design of low noise vacuum cleaner are studied in this paper. At first, sound quality investigation is performed to get the noise level and quality that make people TV watching and catch calls available. Based on the European and domestic customer SQ survey result, sound power, peak noise level and target sound spectrum guideline are studied and introduced. As a second, precise product sound spectrums are designed into each part based on the sound quality result. Fan-motor, brush, mainbody, cyclone spectrums are decided to get the final target sound based on the contribution level. Fan-motor is the major noise source of vacuum cleaner. Specially, its peak sound, RPM peak and BPF Peak, cause the people nervous. To reduce these peak sounds, high rotating impeller and diffuser are focused due to its interaction. A lot of experimental and numerical tests, operation points are investigated and optimization of flow path area between diffusers is performed. As a bagless device, cyclones are one of the major noise sources of vacuum cleaner. To reduce its noise, previous research is used and adopted well. Brush is the most difficult part to reduce noise. Its noise sources are all comes from aero-acoustic phenomena. Numerical analysis helps the understanding of flow structure and pattern, and a lot of experimental test are performed to reduce the noise. Gaps between the carpet and brush are optimized and flow paths are re-designed to lower the noise. Reduction is performed with keeping the cleaning efficiency and handling power together and much reduction of noise is acquired. With all above parts, main-body design is studied. To do a systematic design, configuration design developments technique is introduced from airplane design and evolved with each component design. As a first configuration, fan-motor installation position is investigated and 10 configuration ideas are developed and tested. As a second step, reduced size and compressed configuration candidates are tested and evaluated by a lot of major factor. Noise, power, mass production availability, size, flow path are evaluated together. If noise reduction configuration results in other performance degrade, the noise reduction configuration is ineffective. As a third configuration, cyclones are introduced and the size is reduced one more time and fourth, fifth, sixth, seventh configuration are evolved with size and design image with noise and other performance indexes. Finally we can get a overall much noise level reduction configuration. All above investigations are adopted into vacuum cleaner design and final customer satisfaction tests in Europe are performed. 1st grade sound quality and lowest noise level of bagless vacuum cleaner are achieved.

  • PDF