• Title/Summary/Keyword: Noise-induced

Search Result 1,115, Processing Time 0.03 seconds

Ingestion of Korean Red Ginseng after Noise Exposure Can Potentiate Rapid Recovery of Hearing in Mice

  • Kang, Woo-Seok;Chung, Jong-Woo
    • Journal of Ginseng Research
    • /
    • v.34 no.4
    • /
    • pp.336-341
    • /
    • 2010
  • One mechanism of inner ear damage by noise-induced hearing loss (NIHL) is the production of reactive oxygen species (ROS). Because Korean red ginseng (KRG) has an anti-ROS effect in various tissues, KRG may have a role in preventing NIHL. A window period exists in which ROS formations continue after noise exposure, and further damage can be prevented by antioxidants. In this study, we aimed to investigate the effects of KRG after exposure to noise. KRG (200 mg/kg) was fed to mice for 3 days after noise exposure. The change in hearing level was analyzed by measuring the auditory brainstem response. To induce a temporary threshold shift (TTS) of hearing, mice were exposed to 110 dB white noise for 3 hours. Fast recovery of hearing was observed in mice fed KRG 1 hour and 1 day after noise exposure for 3 days. The expression of 8-oxoguanine was not observed in the inner ears of mice fed KRG 1 hour after noise exposure, but was evident in the stria vascularis of mice in the control group (noise exposure only). From this study, we conclude that KRG acted as an effective inhibitor of NIHL in TTS cases.

Erogonomic assessment of "Noraebang" noise and potential hearing-loss and hearing protection strategies (노래방 소음 및 난청가능성의 인간공학적 평가와 청각보호방안)

  • 박민용
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.79-90
    • /
    • 1996
  • A research project was conducted to assess the levels of noise exposed to "Noraebang" users and potential hazards to noise-induced hearing loss due to commercial Noraebang noise. A two-way, mixed-factors factorial design was employed for the experiment using independent variables of "noise source" (no- singer, 1-singer, and 2-singer conditions) and "music type" (Trot, Ballad, and Rock music) with 18 normal hearing subjects. Each singer group sang 5 popular songs of each music type in each signing condition, whereas background music was just played for the no-singer condition. For each music played/sung, equivalent continuous sound pressure levels and maximum sound pressure levels were measured for data analysis purposes. Pure-tone audiometry was applied for measuring subjects' hearing threshold levels before and after exposure to Noraebgang noise. The statistical analyses indicate that average continuous noise levels due to Noraebang leisure environment were very serious, especially when two people were singing (higher than 95 dBA). Furthermore, maximum noise levels often exceeded the OSHA's non-premissible 115 dBA level. Worse yet, hearing loss assessment implies that Noraebang facilities may pose a serious threat to noise-induced hearing loss, based on 6-8 dB loss at 125 Hz and 8 dB loss at 4000 Hz after about 1-hour Noraebang noise exposure.

  • PDF

Analysis and Suppression Plan for Structure and Flow induced Noise in a Small Refrigeration System (소형 냉동시스템 소음의 구조와 유동 연성 분석과 저감 방안)

  • Kim, Soo-Hyun;Lee, Dong-Yeon;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4129-4136
    • /
    • 2010
  • This paper addresses how to reduce or redesign uncomfortable sound from small refrigerator by modifying some structures in mechanical components or operating conditions. After performing vibration analysis on each component and then sound analysis are carried out. From stepped designed experiments, we could acquire some important results that structure and flow induced vibration assumed to be a major cause to noise level and frequencies. Modifying some mechanical structure and operating conditions, uncomfortable starting noise and beating sound are suppressed. Machinery room located in refrigerator's backside is investigated for vibration and noise suppression, and some ideas for more improvement are suggested.

TWO KINDS OF STATIC AND DYNAMIC STATE ESTIMATION METHODS BY USING WIND SPEED INFORMATION IN ENVIRONMENTAL LOW-FREQUENCY NOISE MEASUREMENT

  • Takakuwa, Y.;Ohta, M.;Nishimura, M.;Minamihara, H.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.806-811
    • /
    • 1994
  • Two kinds of static and dynamic state estimation methods are newly discussed for the problem of the measurement disturbance of environmental low-frequency noise in the presence of wind-induced noise. First, the probability characteristics of wind-induced noise are discussed in the form of probability distribution conditioned by wind speed, based on the simultaneous observation of the wind-induced noise and wind speed near a microphone. Next, especially form the viewpoint of simplicity for practical use, two kinds of static and dynamic state estimation methods are discussed. The static estimation method using the information on wind speed is fundamentally supported by the conservation principle of energy sum. The dynamic one is the method by using a recursive digital filter with the parameters successively renewed by the information on wind speed. This can be also simplified by using well-know Kalman filter under the assumption of the Gaussian distribution. The effectiveness of proposed two estimation methods are shown through experiments under a breezy condition in the open filed.

  • PDF

A 5-GHz Band CCNF VCO Having Phase Noise of -87 dBc/Hz at 10 kHz Offset

  • Lee, Ja-Yol;Lee, Sang-Heung;Kang, Jin-Young;Kim, Bo-Woo;Oh, Seung-Hyeub
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.3
    • /
    • pp.137-142
    • /
    • 2004
  • In this paper, we present a new current-current negative feedback(CCNF) differential voltage-controlled oscillator (VCO) with 1/f induced low-frequency noise suppressed. By means of the CCNF, the 1/f induced low-frequency noise is removed from the proposed CCNF VCO. Also, high-frequency noise is stopped from being down-converted into phase noise by means of the increased output impedance through the CCNF and the feedback capacitor $C_f. The proposed CCNF VCO represents 11-dB reduction in phase noise at 10 kHz offset, compared with the conventional differential VCO. The phase noise of the proposed CCNF VCO is measured as - 87 dBc/Hz at 10 kHz offset frequency from 5.5-GHz carrier. The proposed CCNF VCO consumes 14.0 mA at 2.0 V supply voltage, and shows single-ended output power of - 12 dBm.

RFID Noise Reduction Using a Multi-Coil Antenna (다중 코일 안테나를 이용한 RFID 유도 잡음의 감소)

  • Lee, Seong-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.6
    • /
    • pp.603-611
    • /
    • 2008
  • In this paper, we introduce a multi-coil antenna which is useful for reducing the effects of radio frequency noise in an inductively coupled RFID system. A multi-coil antenna is composed of a central coil and four subsidiary coils that are connected in series. A multi-coil antenna is designed so that the total noise disappear when the induced voltages of a central coil and subsidiary coils are added. The noise in a multi-coil antenna was about 30 dB lower than that in a single coil antenna. The multi-coil antenna is very effective in noise reduction even in an environment that the spatial distribution of RF noise is changed abruptly, and the induced noise was about 16 dB lower than that in a dual coil antenna.

Noise Reduction of Mono Type TV Sets Induced by Speaker (TV 세트의 스피커에 의한 소음 대책 설계)

  • 김종연;이중근;김재환;박상덕;최진성;박종성
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.730-737
    • /
    • 1999
  • This paper illustrates the sound vibration phenomenon of mono type TV set produced by spearker and suggests guidelines for reducing the noise induced by the sound vibrations. In order to illustrate the sound vibration phenomenon, the structural acoustic coupled analysis for the grill and cavity of speaker and structural analysis for main frame are performed. To veify the structural analysis results, experimental modal test is carried out. It is found that the acoustic excitation in the cavity is negligible and main sound vibrations occur near the bottom of TV set. An improved model is found by doing structural modifications based on structural analysis and sound vibration tests are performed to verify the validation of the improved model. The obtained results are applied to similar models and design guide lines for noise reduction are suggested.

  • PDF

Vibration Control and System Identification of Long Span Slab (대형 구조물 바닥판의 동적 거동 및 제어)

  • 황재승;김장윤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.56-59
    • /
    • 2003
  • As the slab is longer and lighter, it is more sensitive to the external force so that the vibration of slab and noise induced by the slab vibration is bigger than expected in normal slab. The purpose of this study is to investigate how the dynamic characteristic of slab is different from the normal slab through the system identification and tn evaluate the vibration control performance when the damper system is installed. Finally, we was trying to understand by what mechanism the slab noise is induced from the slab vibration. The relationship between the vibration and the noise of slab is shown by the numerical simulation.

  • PDF