• Title/Summary/Keyword: Noise-induced

Search Result 1,115, Processing Time 0.026 seconds

A Study on Aerodynamic and Aeroacoustic Characteristics around Pantograph (판토그라프 주변의 유동 및 소음 특성에 관한 연구)

  • 유승원;민옥기;박춘수;정흥채
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.529-536
    • /
    • 2000
  • This paper describes the analysis of aerodynamics and the prediction of airflow induced noise around simplified pantograph. First, computational fluid dynamics (CFD) is conducted far several model to evaluate linear/nonlinear flow field characteristics due to high speed flow and the CFD results support the computational aeroacoustics. The accurate prediction of the aeroacoustic analysis is necessary for designers to control and reduce the airflow induced noise. We adopt the acoustic analogy based on Ffowcs Williams- Hawkings (FW-H) equation and predict aeroacoustic noise.

  • PDF

Active control of noise induced by rotating machines - A 3-dimensional enclosure case (회전기에 의한 소음 제거를 위한 능동 소음 제어 - 3차원 공간의 경우)

  • Nam, Hyun-Do;Ahn, Dong-Jun;Lee, Ho-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.290-292
    • /
    • 1993
  • In this paper, analysis of the noise induced by rotating machines and the mode analysis of a 3-dimensional enclosure are presented. Adaptive active noise control algorithms for the multi-channel case are proposed. Computer simulations were done to show usefulness of the designed algorithm in a 3-dimensional enclosure case.

  • PDF

Transition Rates in a Bistable System Driven by Singular External Forces

  • Cheol-Ju Kim;Dong Jae Lee
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.95-100
    • /
    • 1993
  • A noise-induced transition is presented for a bistable system subjected to a multiplicative random force, which is singular at the unstable state. The stationary probability distribution is obtained from the Fokker-Planck equation and the effects of the singularity is analyzed. On the basis of noise-induced phase transition with Gaussian white noise, the relaxation time and the transition rate of the system are evaluated up to the first order correction of D. In the parameter region v < l, the transition rates decrease as the exponent v goes to 1 and as the coefficient of the linear term of the kinetic equation increases.

Analysis on the Relation between Induced Longitudinal Voltage and Induced Noise Voltage caused by Electrified Railway system (고속전철시설에 의한 전력유도현상의 종전압과 잡음전압의 관계 분석)

  • Cho, Mun-Hwan;Lee, Snag-Mu;Cho, Pyung-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.589-592
    • /
    • 2011
  • Induced longitudinal voltage and induced noise voltage are used in the analysis on the power induction phenomenon and it is well known that these are in the subordinate relationship. But sometimes. there is a confusing situation that these voltages have not exact subordinate relationship in the actual measurement fields. So. we have analyze the correlation between induced longitudinal voltage and induced noise voltage by using tile actual measured data in the fields of 30 urban areas and 30 rural areas.

  • PDF

An Experimental Study on the Noise Generation Mechanisms of Propane Premixed Flames (프로판 예혼합화염의 소음발생 매커니즘에 관한 실험적 연구)

  • Lee, Won-Nam;Park, Dong-Soo
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.27-33
    • /
    • 2004
  • The Noise generation mechanisms of propane laminar premixed flames on a slot burner have been studied experimentally. The sound levels and frequencies were measured for various mixture flow rates (velocities) and equivalence ratios. The primary frequency of self-induced noise increases with the mean velocity of mixture as $f{\;}{\propto}{\;}U_f^{1.144}$ and the measured noise level increases with the mixture flow rate and equivalence ratio as $p{\;}{\propto}{\;}U_f^{1.7}$$F^{8.2}$. The nature of flame oscillation and the noise generation mechanisms are also investigated using a high speed CCD camera and a DSRL camera. The repetition of sudden extinction at the tip of flame is evident and the repetition rates are identical to the primary frequencies obtained from the FFT analysis of sound pressure signals. CH chemiluminescence intensities of the oscillating flames were also measured by PMT with a 431 nm(10 FWHM) band pass filter and compared to the pressure signals.

  • PDF

Characteristics of Flow Induced Noise from a Ball Valve Used for a Gas Pipeline Using an Acoustic Camera (음향 카메라를 이용한 가스 파이프라인 볼밸브 유동소음 특성)

  • KIM, CHUL-KYU;LEE, SANG-MOON;JANG, CHOON-MAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.1
    • /
    • pp.106-112
    • /
    • 2017
  • The present study describes flow induced noise generated from a ball valve used for a gas pipeline. Noise generation from a ball valve mainly induces by interference between unstable(or fluctuating) leakage flow and pipe wall when the ball valve is working closed or opened. To measure the positions of the noise source and the amplitude of noise with respect to measuring frequencies, a commercial acoustic camera is introduced. Noise characteristics generated by the ball valve have been performed by four valve opening rates: 30, 50, 70 and 100 percents. It is noted that 100 percent opening rate means that the valve is fully opened. Throughout the experimental measurements using the acoustic camera, the location of the noise source and the noise amplitude with respect to the frequencies for the test ball valve are clearly evaluated. It is found that the dominant frequencies come from the fluctuating flow at the downstream of the ball valve for four opening rates are observed between 3,000Hz and 3,200Hz. Maximum noise amplitude comes from the ball valve reaches 75dB at the valve opening rate of 50 percent.

The Risk Rating System for Noise-induced Hearing Loss in Korean Manufacturing Sites Based on the 2009 Survey on Work Environments

  • Kim, Young-Sun;Cho, Youn-Ho;Kwon, Oh-Jun;Choi, Seong-Weon;Rhee, Kyung-Yong
    • Safety and Health at Work
    • /
    • v.2 no.4
    • /
    • pp.336-347
    • /
    • 2011
  • Objectives: In Korea, an average of 258 workers claim compensation for their noise-induced hearing loss (NIHL) on an annual basis. Indeed, hearing disorder ranks first in the number of diagnoses made by occupational medical check-ups. Against this backdrop, this study analyzed the impact of 19 types of noise-generating machines and equipment on the sound pressure levels in workplaces and NIHL occurrence based on a 2009 national survey on work environments. Methods: Through this analysis, a series of statistical models were built to determine posterior probabilities for each worksite with an aim to present risk ratings for noise levels at work. Results: It was found that air compressors and grinding machines came in first and second, respectively in the number of installed noise-generating machines and equipment. However, there was no direct relationship between workplace noise and NIHL among workers since noise-control equipment and protective gear had been in place. By building a logistic regression model and neural network, statistical models were set to identify the influence of the noise-generating machines and equipment on workplace noise levels and NIHL occurrence. Conclusion: This study offered NIHL prevention measures which are fit for the worksites in each risk grade.

Flow-Induced Noise Prediction for Submarines (잠수함 형상의 유동소음 해석기법 연구)

  • Yeo, Sang-Jae;Hong, Suk-Yoon;Song, Jee-Hun;Kwon, Hyun-Wung;Seol, Hanshin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.7
    • /
    • pp.930-938
    • /
    • 2018
  • Underwater noise radiated from submarines is directly related to the probability of being detected by the sonar of an enemy vessel. Therefore, minimizing the noise of a submarine is essential for improving survival outcomes. For modern submarines, as the speed and size of a submarine increase and noise reduction technology is developed, interest in flow noise around the hull has been increasing. In this study, a noise analysis technique was developed to predict flow noise generated around a submarine shape considering the free surface effect. When a submarine is operated near a free surface, turbulence-induced noise due to the turbulence of the flow and bubble noise from breaking waves arise. First, to analyze the flow around a submarine, VOF-based incompressible two-phase flow analysis was performed to derive flow field data and the shape of the free surface around the submarine. Turbulence-induced noise was analyzed by applying permeable FW-H, which is an acoustic analogy technique. Bubble noise was derived through a noise model for breaking waves based on the turbulent kinetic energy distribution results obtained from the CFD results. The analysis method developed was verified by comparison with experimental results for a submarine model measured in a Large Cavitation Tunnel (LCT).

Characteristics of Noise Induced Hearing Loss of Fishermen Visiting a General Hospital (일개 종합병원을 방문한 어선원에서 발생한 소음성 난청의 특징)

  • You Sun Chung;Chang Hoi Kim
    • Journal of agricultural medicine and community health
    • /
    • v.48 no.1
    • /
    • pp.41-49
    • /
    • 2023
  • Objectives: To obtain audiologic basic data to diagnose the noise induced hearing loss of workers in fisheries. Methods: The charts of the referred fishermen with noise induced hearing loss from November 2022 to February 2023 at a general hospital were retrospectively reviewed. Pure tone audiometry, speech audiometry, auditory brainstem response test and auditory steady state response test were conducted. Results: All of them were men over 60 years of age, and the average duration of exposure to noise was 38.9 ± 10.8 years, and the average symptom duration of hearing loss was 13.4 ± 4.3 years. Although the hearing thresholds in the high frequencies were higher than thresholds in the low frequencies, the audiogram showed a down-sloping pattern without rebound at 8 kHz. 10.5% of the cases had thresholds greater than 75 dB in high frequencies, but 57.9% had thresholds greater than 40 dB in low frequencies. Other hearing test results of fishermen were similar to those of general noise-induced hearing loss. Conclusions: Although the fishermen were exposed to noise for a long time, they recognized hearing loss late. The hearing threshold in lower frequencies of the fishermen was higher than expected. Further studies will be needed to analyze the audiologic characteristics of noise-induced hearing loss of the fishermen after confirming noise exposure by conducting a survey on the working environment, such as the noise level and working hours.