• Title/Summary/Keyword: Noise-induced

Search Result 1,115, Processing Time 0.029 seconds

Design and Performance Analysis of Current Source for 3.0T MREIT System (3.0T MREIT 시스템을 위한 정전류원의 설계 및 성능검증)

  • 김규식;오동인;백상민;오석훈;우응제;이수열;이정한
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.165-169
    • /
    • 2004
  • In Magnetic Resonance Electrical Impedance Tomography (MREIT), we inject current through electrodes placed on the surface of a subject and measure the induced magnetic flux density distribution using an MRI scanner. This requires a constant current source whose output pulses are synchronized with MR pulse sequences. In this paper, we present a design and performance analysis of a current source used in a 3.0T MREIT system. The developed current source was tested using a saline phantom. We found that its performance is satisfactory for the current MREIT system. We suggest future improvements for better SNR(signal-to-noise ratio).

Observation of the Earth's Magnetic field from KOMPSAT-1

  • Hwang, Jong-Sun;Kim, Sung-Yong;Lee, Seon-Ho;Min, Kyung-Duck;Kim, Jeong-Woo;Lee, Su-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1236-1238
    • /
    • 2003
  • The Earth's total magnetic field was extracted from on board TAM (Three Axis Magnetometer) observations of KOMPSAT-1 satellite between June 19th and 21st, 2000. In the pre-processing, the TAM's telemetry data were transformed from ECI (Earth Centered Inertial frame) to ECEF (Earth Centered Earth Fixed frame) and then to spherical coordination, and self-induced magnetic field by satellite bus itself were removed by using an on-orbit magnetometer data correction method. The 2-D wavenumber correlation filtering and quadrant-swapping method were applied to the pre-processed data in order to eliminate dynamic components and track-line noise, respectively. Then, the spherical harmonic coefficients are calculated from KOMPSAT-1 data. To test the validity of the TAM's geomagnetic field, Danish/NASA/French ${\phi}$rsted satellite's magnetic model and IGRF2000 model were used for statistical comparison. The correlation coefficient between ${\phi}$rsted and TAM is 0.97 and IGRF and TAM is 0.96. It was found that the data from on board magnetometer observations for attitude control of Earth-observing satellites can be used to determinate the Earth's total magnetic field and that they can be efficiently used to upgrade the global geomagnetic field coefficients, such as IGRF by providing new information at various altitudes with better temporal and spatial coverage.

  • PDF

Analysis of Land Cover Change Around Desert Areas of East Asia (식생 자료를 이용한 동아시아 사막 주변의 토지피복 변화 분석)

  • Ryu, Jae-Hyun;Han, Kyung-Soo;Pi, Kyoung-Jin;Lee, Min-Ji
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.1
    • /
    • pp.105-114
    • /
    • 2013
  • Desertification of the East Asia area induced by human's indiscriminate activities and natural causes has gradually expanded and demanded scientific research for monitoring and predicting land cover condition. Therefore, this research classified land types which were compared to MODIS land cover and analyzed the extent of barren zone effecting Korea through yellow dust using S10-DAY MVC NDVI from SPOT between 1999 and 2011. This study used unsupervised classification after processing NDVI Correction and Water Mask for eliminating noise values included in the data for enhancement of classification accuracy. The results of analysis are that there are active variations near the borders of desert, especially the Mongolian steppe and the Gobi Desert in central Asia. In addition, the extent of entire desert has been decreased in the middle of the last decade, although desertification is in going on in East Asia.

A Design of a Fault Tolerant Control System Using On-Line Learning Neural Networks (온라인 학습 신경망 조직을 이용한 내고장성 제어계의 설계)

  • Younghwan An
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1181-1192
    • /
    • 1998
  • This paper describes the performance of a full-authority neural network-based fault tolerant system within a flight control system. This fault tolerant flight control system integrates sensor and actuator failure detection, identification, and accommodation (SFDIA and AFDIA), The first task is achieved by incorporating a main neural network (MNN) and a set of n decentralized neural networks (DNNs) to create a system for achieving fault tolerant capabilities for a system with n sensors assumed to be without physical redundancy The second scheme implements the same main neural network integrated with three neural network controllers (NNCs). The function of NNCs is to regain equilibrium and to compensate for the pitching, rolling. and yawing moments induced by the failure. Particular emphasis is placed in this study toward achieving an efficient integration between SFDIA and AFDIA without degradation of performance in terms of false alarm rates and incorrect failure identification. The results of the simulation with different actuator and sensor failures are presented and discussed.

  • PDF

Illumination Robust Feature Descriptor Based on Exact Order (조명 변화에 강인한 엄격한 순차 기반의 특징점 기술자)

  • Kim, Bongjoe;Sohn, Kwanghoon
    • Journal of Broadcast Engineering
    • /
    • v.18 no.1
    • /
    • pp.77-87
    • /
    • 2013
  • In this paper, we present a novel method for local image descriptor called exact order based descriptor (EOD) which is robust to illumination changes and Gaussian noise. Exact orders of image patch is induced by changing discrete intensity value into k-dimensional continuous vector to resolve the ambiguity of ordering for same intensity pixel value. EOD is generated from overall distribution of exact orders in the patch. The proposed local descriptor is compared with several state-of-the-art descriptors over a number of images. Experimental results show that the proposed method outperforms many state-of-the-art descriptors in the presence of illumination changes, blur and viewpoint change. Also, the proposed method can be used for many computer vision applications such as face recognition, texture recognition and image analysis.

A Study on Multiband FTN Method for Improving Throughput Efficiency (전송 효율 향상을 위한 다중 밴드 FTN 기법 연구)

  • Seo, Jung-Hyun;Baek, Chang-Uk;Jung, Ji-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.3
    • /
    • pp.235-240
    • /
    • 2018
  • FTN method which transmits signals faster the Nyquist rate is representative method for improving throughput efficiency sacrificed performance due to inter-symbol interference. To compensate performance loss, in this paper, we propose a multiband FTN method which split the coded bits into several bands and transmits signals applying FTN method. As coded bits are being assigned different bands, number of samples per bit of each band is increased, it induced performance improvement by noise averaging effect. In the simulations, compared the performance of single band FTN method and multiband FTN method when the interference rate is 25%. The results of simulation show the performance of proposed method is better than that of single band FTN one by 0.3dB~0.5dB.

The Effect of Adaptation to Sound Intensity on the Neural Metabolism in Auditory Pathway: Small Animal PET Study (소동물 [F-18]FDG 양전자단층촬영 기법을 이용한 청각신경에서의 소리크기에 대한 적응효과 연구)

  • Jang, Dong-Pyo
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.55-60
    • /
    • 2011
  • Although sound intensity is considered as one of important factors in auditory processing, its neural mechanism in auditory neurons with limited dynamic range of firing rates is still unclear. In this study, we examined the effect of sound intensity adaptation on the change of glucose metabolism in a rat brain using [F-18] micro positron emission tomography (PET) neuroimaging technique. In the experiment, broadband white noise sound was given for 30 minutes after the [F-18]FDG injection in order to explore the functional adaptation of rat brain into the sound intensity levels. Nine rats were scanned with four different sound intensity levels: 40 dB, 60 dB, 80 dB, 100 dB sound pressure level (SPL) for four weeks. When glucose uptake during the adaptation of a high intensity sound level (100 dB SPL) was compared with that during adaptation to a low intensity level (40 dB SPL) in the experiment, the former induced a greater uptake at bilateral cochlear nucleus, superior olivary complexes and inferior colliculi in the auditory pathway. Expectedly, the metabolic activity in those areas linearly increased as the sound intensity level increased. In contrast, significant decrease interestingly occurred in the bilateral auditory cortices: The activities of auditory cortex proportionally decreased with higher sound intensities. It may reflect that the auditory cortex actively down-regulates neural activities when the sound gets louder.

Amplitude dependency of damping of tall structures by the random decrement technique

  • Xu, An;Xie, Zhuangning;Gu, Ming;Wu, Jiurong
    • Wind and Structures
    • /
    • v.21 no.2
    • /
    • pp.159-182
    • /
    • 2015
  • This study focuses on the amplitude dependency of damping of tall structures by the random decrement technique (RDT). Many researchers have adopted RDT to establish the amplitude dependency of damping ratios in super-tall buildings under strong wind loads. In this study, a series of simulated examples were analyzed to examine the reliability of this method. Results show that damping ratios increase as vibration amplitudes increase in several cases; however, the damping ratios in the simulated signals were preset as constants. This finding reveals that this method and the derived amplitude-dependent damping ratio characteristics are unreliable. Moreover, this method would obviously yield misleading results if the simulated signals contain Gaussian white noise. Full-scale measurements on a super-tall building were conducted during four typhoons, and the recorded data were analyzed to observe the amplitude dependency of damping ratio. Relatively wide scatter is observed in the resulting damping ratios, and the damping ratios do not appear to have an obvious nonlinear relationship with vibration amplitude. Numerical simulation and field measurement results indicate that the widely-used method for establishing the amplitude-dependent damping characteristics of super-tall buildings and the conclusions derived from it might be questionable at the least. More field-measured data must be collected under strong wind loads, and the damping characteristics of super-tall buildings should be investigated further.

The Controller Design of a 2.4MJ Pulse Power Supply for a Electro-Thermal-Chemical Gun (전열화학포용 2.4MJ 펄스 파워 전원의 제어기 설계)

  • Kim, Jong-Soo;Jin, Y.S.;Lee, H.S.;Rim, Geun-Hie;Kim, J.S.
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.511-517
    • /
    • 2006
  • The key issues in high power, high energy applications such as electromagnetic launchers include safety, reliability, flexibility, efficiency, compactness, and cost. To explore some of the issues, a control scheme for a large current wave-forming was designed, built and experimentally verified using a 2.4MJ pulse power system (PPS). The PPS was made up of eight capacitors bank unit, each containing six capacitors connected in parallel. Therefore there were 48 capacitors in total, with ratings of 22kV and 50kJ each. Each unit is charged through a charging switch that is operated by air pressure. For discharging each unit has a triggered vacuum switch (TVS) with ratings of 200kA and 250kV. Hence, flexibility of a large current wave-forming can be obtained by controlling the charging voltage and the discharging times. The whole control system includes a personal computer(PC), RS232 and RS485 pseudo converter, electric/optical signal converters and eight 80C196KC micro-controller based capacitor-bank module(CBM) controllers. Hence, the PC based controller can set the capacitor charging voltages and the TVS trigger timings of each CBM controller for the current wave-forming. It also monitors and records the system status data. We illustrated that our control scheme was able to generate the large current pulse flexibly and safely by experiments. The our control scheme minimize the use of optical cables without reducing EMI noise immunity and reliability, this is resulting in cost reduction. Also, the reliability was increased by isolating ground doubly, it reduced drastically the interference of the large voltage pulse induced by the large current pulse. This paper contains the complete control scheme and details of each subsystem unit.

Characteristic of the Regression Lines for EMG Median Frequency Data Based on the Period of Regression Analysis During Fatiguing Isotonic Exercise (등장성 운동 시 회귀분석기간에 따른 근전도 중앙주파수 회귀직선의 특징)

  • Kim, Yu-Mi;Cho, Sang-Hyun;Lee, Young-Hee
    • Physical Therapy Korea
    • /
    • v.8 no.3
    • /
    • pp.63-76
    • /
    • 2001
  • Many studies have shown that the initial median frequency (MDF) and slope correlate with the muscle fiber composition. This study tested the hypothesis that the initial MDF and slope are fixed, regardless of the interval at which data are collected. MDF data using moving fast Fourier transformation of EMG signals, following local fatigue induced by isotonic exercise, were obtained. An inverse FFT was used to eliminate noise, and characteristic decreasing regression lines were obtained. The regression analysis was done in three different periods, the first one third, first half, and full period, looking at variance in the initial MDF, slope, and fatigue index. Data from surface EMG signals during fatiguing isotonic exercise of the biceps brachii and vastus lateralis in 20 normal subjects were collected. The loads tested were 30% and 60% maximum voluntary contraction (MVC) in the biceps brachii and 40% and 80% MVC in the vastus lateralis. The rate was 25 flexions per minute. There were no significant differences in the initial MDF or slope during the early or full periods of the regression, but there was a significant difference in the fatigue index. Therefore, to observe the change in the initial MDF and slope of the MDF regression line during isotonic exercise, this study suggest that only the early interval need to be observed.

  • PDF