• 제목/요약/키워드: Noise-induced

검색결과 1,116건 처리시간 0.031초

SNG 선회 안정화 화염구조 가시화를 위한 OH* 자발광 이미지 역변환에서 전처리 효과 (Effect of a Preprocessing Method on the Inversion of OH* Chemiluminescence Images Acquired for Visualizing SNG Swirl-stabilized Flame Structure)

  • 안광호;송원준;차동진
    • 한국연소학회지
    • /
    • 제20권1호
    • /
    • pp.24-31
    • /
    • 2015
  • Flame structure, which contains a useful information for studying combustion instability of the flame, is often quantitatively visualized with PLIF (planar laser-induced fluorescence) and/or chemiluminescence images. The latter, a line-integral of a flame property, needs to be preprocessed before being inverted, mainly due to its inherent noise and the axisymmetry assumption of the inversion. A preprocessing scheme utilizing multi-division of ROI (region of interest) of the chemiluminescence image is proposed. Its feasibility has been tested with OH PLIF and $OH^*$ chemiluminescence images of SNG (synthetic natural gas) swirl-stabilized flames taken from a model gas turbine combustor. It turns out that the multi-division technique outperforms two conventional ones: those are, one without preprocessing and the other with uni-division preprocessing, reconstructing the SNG flame structure much better than its two counterparts, when compared with the corresponding OH PLIF images. It is also found that the Canny edge detection algorithm used for detecting edges in the multi-division method works better than the Sobel algorithm does.

한국형 인공심장내의 심실간 압력 측정시스템의 개발 (Development of an Interventricular Pressure Measurement System or the Korean Total Artificial Heart)

  • 최성욱;안재목;조영호;엄경식;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.126-130
    • /
    • 1997
  • In the development of the totally implantable artificial heart (TAH), the information of the preload condition is important to ind appropriate condition or the automatic control of the heart. Our TAH configuration consists of two artificial ventricles, and brushless DC motor within actuator. The pressure between ventricles could indicate the preload condition during the TAH operation. If we can measure accurately inspite of the noise induced from TAH and environmental condition. We suggested integrating a feedback loop to remove an unexpected DC drift. NPI 19-series Nova sensor was used which could measure pressure in gas and liquid. This method and sensor enabled us to develop the pressure transducer compact so (that) the systems can be implanted with TAH into patient. This system has been verified in vitro and in vivo test. This results showed that the output waveform of this system was stable irrespective of animal condition.

  • PDF

Fe-Cr-Mn-X계 합금의 감쇠능 및 플라즈마이온질화 특성에 미치는 합금원소의 영향 [I 감쇠능] (The Effect of Alloy Elements on the Damping Capacity and Plasma Ion Nitriding Characteristic of Fe-Cr-Mn-X Alloys [I Damping Capacity])

  • 손동욱;정상훈;김재환;이종문;김익수;강창룡
    • 동력기계공학회지
    • /
    • 제9권1호
    • /
    • pp.70-75
    • /
    • 2005
  • The damping property of Fe-12Cr-22Mn-X alloys has been investigated to develop high damping and high strength alloy. Particularly, the effect of the phase of austenite, alpha and epsilon martensite, which constitute the structure of the alloys Fe-12Cr-22Mn-X alloys, on the damping capacity at room temperature has been investigated. Various fraction of these phases were formed depending on the alloy element and cold work degree. The damping capacity is strongly affected by ${\varepsilon}$ martensite while the other phase, such as ${\alpha}'$ martensite, actually exhibit little effect on damping capacity. In case of Fe-12Cr-22Mn-3Co alloy, the large volume fraction of ${\varepsilon}$ martensite formed at about 30% cold rolling, and in case of Fe-12Cr-22Mn-1Ti alloy, formed at about 20% cold rolling and showed the highest damping capacity. Damping capacity showed higher value in Fe-12Cr-22Mn-1Ti alloy than one in Fe-12Cr-22Mn-3Co alloy.

  • PDF

Fe-Al-Mn 합금의 진동감쇠능 및 인장성질에 미치는 미세조직의 영향 (Effect of Microstructure on the Damping Capacity and Tensile Properties of Fe-Al-Mn Alloys)

  • 손동욱;김재환;이종문;김익수;김한청;강창룡
    • 동력기계공학회지
    • /
    • 제8권4호
    • /
    • pp.31-37
    • /
    • 2004
  • The damping capacity and strength of Fe-2Al-26Mn alloys have been studied for the development of new materials with high strength and damping capacity. Particularly, the effect of ${\alpha}'\;and\;{\varepsilon}$ martensite phase, which constitutes the microstructure of cold rolled Fe-Al-Mn alloys, has been investigated in terms of the strength and damping capacity of the alloys. The damping capacity rises with increasing the degree of cold rolling and reveals the maximum value at 25% reduction. The damping capacity is strongly affected by the volume fraction of ${\varepsilon}$ martensite, while the other phases, such as ${\alpha}'$ martensite and austenite phase, actually exhibit little effect on damping capacity. Considering that tensile strength increases and elongation decreases with increasing the volume fraction of ${\alpha}'$ martensite, it is proved that tensile strength is mainly affected by the amount of ${\alpha}'$ martensite.

  • PDF

Design and Fabrication of Miniaturized Optical Chopper Operated by Electromagnetic Actuation

  • Kim, Ho Won;Min, Seong Ki;Choi, Young Chan;Kong, Seong Ho
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.165-169
    • /
    • 2014
  • An existing infrared (IR) analysis system is generally composed of infrared source, IR focusing lenses, IR detector, and optical chopper. An optical chopper is widely used in combination with lock-in amplifier to improve the signal-to-noise ratio by periodically interrupting incident light beam. During recent years, a few researches on miniaturized optical chopper have been reported to apply to micro-scaled optical systems. In this paper, a micro optical chopper operated by electromagnetic actuation is proposed and applied to a miniaturized micro-scaled optical system operating in IR spectral range. Additionally, the fabrication method of the proposed micro chopper is demonstrated. The proposed micro optical chopper is composed of the polydimethylsiloxane (PDMS) membrane, solenoid, and permanent magnet. The permanent magnet is bonded on the PDMS membrane using an ultraviolet-activated adhesive. The operation of the chopper is based on the attractive and repulsive forces between permanent magnet and solenoid induced by an electrical current flowing through the solenoid. The fabricated micro optical chopper could operate up to 200 Hz of frequency. The maximum operating distance of the chopper with 7mm diameter membrane was $750{\mu}m$ at 100 Hz of frequency.

태아 중 소음 스트레스가 출생 후 해마 내 c-Fos 발현에 미치는 인삼의 효과 (Influences of Postnatal Ginseng radix Administration on Prenatal Noise Stress-induced c-Fos Expression in the Hippocampus of Offspring Rats)

  • 장재찬;김연섭;김지혁
    • 동의신경정신과학회지
    • /
    • 제17권3호
    • /
    • pp.1-10
    • /
    • 2006
  • 목적:임신 중 소음 스트레스가 태아에 어떤 영향을 미치는 가를 관찰하고자, 임신 중인 흰쥐에 소음 스트레스를 가한 후 출생한 새끼 흰쥐에 인삼을 투여하여 신경적 발육에 대한, 특히 새끼 흰쥐 해마의 c-Fos 관점에서 연구하였다. 결과:CIA 영역의 c-Fos-positive 세포의수는, 출생 전 소음 스트레스를 받은 대조군에 비해, 10 mg/kg의 인삼을 투여한 군에서 유의성 있는 감소를 보였다. 해마의 CA2, CA3 영역에서의 c-Fos-positive 세포의 수는 10 mg/kg의 인삼을 투여한 그룹에서, 출생 전 소음 스트레스를 받은 대조군에 비해 유의성 있는 감소를 보였다. 해마의 dentate gyrus 영역에서 c-Fos-positive 세포의 수는, 10 mg/kg의 인삼을 투여한 그룹에서, 출생 전 소음 스트레스를 받은 대조군에 비해 유의성 있는 감소를 보였다. 결론: 인삼은 태아기 소음 스트레스로 야기되는 c-Fos의 변화로 인한 해마의 기능장애에 중화제로서 사용될 수 있다. 그리고 임신 중 소음 스트레스를 경험한 엄마의 아이들에 있어서 정신과적 문제를 치료하는데 유용할 것이다.

  • PDF

색상 검출방식의 천이 액정법에서 색상 변화 시간 산정의 정확도 향상 (Improvement of Accuracy in Evaluating Hue Change Time in the Hue Detection Based Transient Liquid Crystals Technique)

  • 신소민;전창수;정용운;곽재수
    • 대한기계학회논문집B
    • /
    • 제31권11호
    • /
    • pp.918-925
    • /
    • 2007
  • In this paper, different criteria fur determining hue change time in the hue detection based transient liquid crystals technique were compared. Results showed that methods utilizing threshold of intensity or saturation gave many missing points and quality of the calculated results were strongly depends on the value of threshold. Wider bandwidth in the hue bandwidth method showed better distribution of calculated hue change time, but induced ambiguity in the hue change time. In the time-hue curve fitting method, the distribution of evaluated hue change time was smooth and reasonable, and, by the nature of curve fitting, the noise effect on the hue was successfully considered in calculating of the hue change time. Compared to other methods, it is expected that the time-hue curve fitting method would provide better and accurate hue change time in the hue detection based transient liquid crystals technique.

튜브와 지지대 사이의 동적상호 충격력 측정장치 특성규명에 관한 연구 (A Study on the Characteristics of the Tube-to-Support Dynamic Impact Force Measurement Facility)

  • 김일곤;박진무
    • 소음진동
    • /
    • 제5권1호
    • /
    • pp.95-106
    • /
    • 1995
  • Flow-induced vibration in heat exchanger (or fuel rod) in nuclar power plant can cause dynamic interactions between tubes and tube supports resulting in fretting-wear. To increase the reliability and design life of heat exchanger components, design criteria that establish acceptable limits of vibration and minimize fretting wear are necessary. The fretting-wear rate is dependent upon material combination, contact configuration, environmental conditions and tube-to tube support dynamic interaction. It is demostrated that the fretting -wear rate correlates well with tube-to-support contact force or work rate. The tube-to-support dynamic interaction, which consists of dynamic contact forces and tube motion, is used to relate single-span wear data to real heat exchanger configurations consisting of multi-span tube bundles. This paper describes the test facility to measure tube-to-support dynamic impact force and reports its dynamic characteristics through the four impact tests - a force transduces independent and external impact tests, central ring inside impact test and additional cylinder impact test. Through the tests the impact parameter change dependent upon the material difference of impacting ball is studied, and the impact parameters of Force Transducer Assembly components are measured. And also the dynamic behavior of Force Transducer Assembly is analyzed. The force measurement technique herein is shown to provide a reasonable measure of dynamic contact forces.

  • PDF

발파진동으로 인한 공작기계 가공정도의 영향 평가 (Evaluation of the Influence of Blast Vibration on Machine Tool Accuracy)

  • 이진갑
    • 한국산학기술학회논문지
    • /
    • 제15권8호
    • /
    • pp.4790-4795
    • /
    • 2014
  • 공작기계는 기계산업의 생산 및 시제품가공 등에 널리 적용되고 있다. 폭발시 발생하는 지반진동은 인근 구조물의 손상이나 시설에 많은 영향을 미친다. 본 논문은 발파진동이 공작기계의 가공정밀도에 미치는 영향을 고찰하였다. 발파진동과 발파시 공작기계의 진동을 측정하였고, 진동허용치를 기준으로 평가하였다. 공작기계의 진동허용치를 기준으로 할 경우 본 연구에 사용된 공작기계의 발파시 진동허용치는 SLIGHTLY ROUGH~ROUGH에 해당된다. 발파진동이 반복될 경우 정밀도가 저하될 가능성이 많다.

동적 방사선투과검사를 이용한 지상연소시험 기술개발 (An Application of Dynamic Radioscopy Technique to Static Firing Test)

  • 임수용;김준엽;김인식
    • 한국추진공학회지
    • /
    • 제10권3호
    • /
    • pp.32-40
    • /
    • 2006
  • 본 연구는 소형 로켓모터의 지상연소시험 시 동적 방사선투과검사를 이용하여 로켓모터의 내부 연소현상을 실시간으로 관측하는 시험 기술을 개발하고자 하였다. 이를 위해 자체 설계/제작한 영상촬영상자와 300 kV급 X선 발생장치를 사용하여 지상연소시험을 실시하였고, 연소 중 발생되는 진동과 소음 등의 외부 환경인자로부터 영상의 안정화와 장비보호를 위하여 방진/방음 장치를 개발하여 적용하였다. 시험결과, 측정부위의 진동크기가 장비의 정상운용을 위한 허용한계 이하로 측정되었으며, 연소 중 로켓모터 내부형상과 추진제 연소면의 변화를 명확히 관찰할 수 있었다.