• 제목/요약/키워드: Noise standards level

검색결과 109건 처리시간 0.029초

Quality Evaluation of Ultrasonographic Equipment Using an ATS-539 Multipurpose Phantom in Veterinary Medicine

  • Cho, Young-kwon;Lee, Youngjin;Lee, Kichang
    • 한국임상수의학회지
    • /
    • 제39권3호
    • /
    • pp.114-120
    • /
    • 2022
  • The purpose of this study is to examine the status of quality control using multipurpose phantom of ultrasound equipment used in hospital of veterinary college in South Korea by using ATS-539 multipurpose phantom so as to examine quantitative and objective new image evaluation method. Specialists discussed and analyzed multipurpose phantom images acquired by using convex transducer of 10 ultrasound imaging devices, currently used in 9 veterinary colleges, at 4.0-6.0 MHz. Total 8 items that can be measured with ATS-539 multipurpose phantom including dead zone, vertical and horizontal measurement, axial/lateral resolution, sensitivity, focal zone, functional resolution and gray scale/dynamic range were evaluated. For qualitative evaluation, valid decisions were made based on dead zone, axial/lateral resolution, and gray scale/dynamic range which are resolution index, and coefficient of variation (COV) and blind referenceless image spatial quality evaluator (BRISQUE) were found to increase objectivity. As a result of experiment, all the targeted ultrasonic devices were found appropriate from qualitative evaluation items of dead zone, axial/lateral resolution, and gray scale/dynamic range. In other evaluation items, they were found to be appropriate from focal zone and vertical measurement of quantitative evaluation while inappropriate from horizontal measurement, sensitivity, and functional resolution. COV value was 0.12 ± 0.04, and BRISQUE value was 47.77 ± 2.77, both analysis results show that the noise level of all ultrasonic devices was located within tolerance range. Upon image examination using ATS-539 multipurpose phantom, they were 100% appropriate with inspection standards of dead zone, axial/lateral resolution, and gray scale/dynamic range, and besides, focal zone and functional resolution can be used as evaluation items. In the field of veterinary medicine, 8 standard items using ATS-539 multipurpose phantom and image evaluation items using COV and BRISQUE can be used as standards for quality control of ultrasonography machine.

충격소음으로 인한 양식어류 피해기준 제안 (Suggestion of Safety Level in Fish Farming by Impulsive Sound)

  • 최태홍;김정한;송하림;고진석
    • 터널과지하공간
    • /
    • 제25권2호
    • /
    • pp.125-132
    • /
    • 2015
  • 어류 양식장 인근에서 건설공사로 인하여 발생하는 소음 진동의 경우 피해 금액과 산정방식 선정은 건설공사에 대한 공종별 전문가의 공학적, 기술적 의견이 배제된 상태에서 이루어지고 있다. 피해자 측이 일방적으로 어류 전문가들의 생물학적 자문 위주의 논리만 주장하는 반면, 어류에 대한 생물학적 전문지식이 부족한 건설사 측은 일반적인 건설소음 진동에 관한 논리를 전개하는 경우가 대부분이다. 그래서 중앙 환경 분쟁 조정위원회에서는 2009년 소음 진동으로 인한 육상 양식어류 피해 평가 및 배상액 산정기준에 관한 연구를 통해 구체적인 피해기준을 제시하였다. 국내의 경우 수중소음 피해인정 기준을 140 dB re $1{\mu}Pa$을 인정하고 있다. 이 기준은 충격음이 아닌 1초 이상의 연속음의 RMS 값이다. 또한, 기존 연구 자료들을 보면 어류는 골표류와 비골표류, 기각류와 비기각류 등 어종에 따라서 수중소음에 대한 반응이 많은 차이가 있는 것으로 보인다. 그래서 본 연구는 충격음과 연속음의 특성 차이를 고려하여 충격음의 피해기준을 제시하려 한다.

의료기관 리모델링의 법적 제문제 (Legal Issues of Medical Institution Remodeling)

  • 신태섭;정미영
    • 한국콘텐츠학회논문지
    • /
    • 제21권8호
    • /
    • pp.294-304
    • /
    • 2021
  • 의료기관은 환자의 만족도 충족과 타 의료기관과의 경쟁력 향상을 위해 신축보다는 기존 병원 건물을 리모델링하게 된다. 의료기관 리모델링은 의료의 질과 환자 안전의 수준 향상을 위해 강화된 법과 제도로 인하여 점차 증가하고 있다. 다만 선행연구들은 의료기관 리모델링에 대해 건축적 요소 등 제한된 범위에서만 논의가 이루어졌다. 이에 본 연구는 의료기관 리모델링의 법적 제문제를 다각적으로 검토함으로써 향후 리모델링을 계획하는 의료기관에게 기본적인 자료를 제공하고자 한다. 의료기관 리모델링은 공사 여건의 제한으로 공사 기간이 길어지고, 환자에게 소음·분진 등의 피해를 발생시킨다. 따라서 사전에 환자의 피해를 예방하고 적정한 의료기관의 리모델링을 지원하는 방안이 필요하다. 이에 의료기관 리모델링 활성화 및 지원에 관한 법률 마련이 필요하다. 그리고 의료기관은 공사기준 자율 준수 체크리스트, 사전 방지조치 및 사후 개선조치, 병원 내 감염과 방사선 노출에 대한 대책을 마련해야 한다.

Low Frequency Noise and It's Psychological Effects

  • Eom, Jin-Sup;Kim, Sook-Hee;Jung, Sung-Soo;Sohn, Jin-Hun
    • 대한인간공학회지
    • /
    • 제33권1호
    • /
    • pp.39-48
    • /
    • 2014
  • Objective: This entire study has two parts. Study I aimed to develop a psychological assessment scale and the study II aimed to investigate the effects of LFN (low frequency noise) on the psychological responses in humans, using the scale developed in the study I. Background: LFN is known to have a negative impact on the functioning of humans. The negative impact of LFN can be categorized into two major areas of functioning of humans, physiological and psychological areas of functioning. The physiological impact can cause abnormalities in threshold, balancing and/or vestibular system, cardiovascular system and, hormone changes. Psychological functioning includes cognition, communication, mental health, and annoyance. Method: 182 college students participated in the study I in development of a psychological assessment scale and 42 paid volunteers participated in the study II to measure psychological responses. The LFN stimuli consisted of 12 different pure tones and 12 different 1 octave-band white noises and each stimulus had 4 different frequencies and 3 different sounds pressure levels. Results: We developed the psychological assessment scale consisting of 17 items with 3 dimensions of psychological responses (i.e., perceived physical, perceived physiological, and emotional responses). The main findings of LFN on the responses were as follows: 1. Perceived psychological responses showed a linear relation with SPL (sound pressure level), that is the higher the SPL is, the higher the negative psychological responses were. 2. Psychological responses showed quadric relations with SPL in general. 3. More negative responses at 31.5Hz LFN than those of 63 and 125Hz were reported, which is deemed to be caused by perceived vibration by 31.5Hz. 'Perceived vibration' at 31.5Hz than those of other frequencies of LFN is deemed to have amplified the negative psychological response. Consequently there found different effects of low frequency noise with different frequencies and intensity (SPL) on multiple psychological responses. Conclusion: Three dimensions of psychological responses drawn in regard to this study differed from others in the frequencies and SLP of LFN. Negative psychological responses are deemed to be differently affected by the frequency, SPL of the LFN and 'feel vibration' induced by the LFN. Application: The psychological scale from our study can be applied in quantitative psychological measurement of LFN at home or industrial environment. In addition, it can also help design systems to block LFN to provide optimal conditions if used the study outcome, .i.e., the relations between physical and psychological responses of LFN.

사물인터넷 기반 실내 환경 모니터링 및 자동제어 시스템 구현 (Implementation of Indoor Environment Monitoring and Automatic Control System based on Internet of Things)

  • 이상훈;김진엽;김수연
    • 한국산업정보학회논문지
    • /
    • 제21권6호
    • /
    • pp.71-80
    • /
    • 2016
  • 생활수준이 점차 높아짐에 따라 환경문제에 대한 국민들의 관심과 인식 수준도 증가하였다. 최근 들어 실내 활동시간이 증가함에 따라 환경에 대한 인식과 개선에 대한 방안이 요구되고 있다. 본 연구에서는 IoT 기반 기술을 이용하여 실시간으로 실내 환경에 대한 모니터링을 통해 환경정보를 수집하고 연동된 제어장치를 이용하여 실내 환경을 적정수준으로 유지하고 개선하는 시스템을 설계하고 개발하였다. 이는 기존의 수동적인 실내 환경개선 행위나 대규모 설비를 대신하여 가정이나 소규모 장소에서도 자동적인 실내 환경개선 시스템을 제공한다. 본 시스템은 공기 질과 CO2, 온도와 습도, 소음과 조도에 따른 상태분석과 함께 상대적 기준치를 적용하여 9가지의 상태에 따른 제어신호를 자동제어 모듈로 전송하여 실내 환경을 개선한다.

전자산업 공정에서 사용한 부품, 기계류 세정(cleaning) 작업 안전보건 가이드 (Development of an Occupational Safety and Health (OSH) Guide for Safely Cleaning Contaminated Machinery, Equipment, and Parts Used in the Electronics Manufacturing Process)

  • 이승희;김소연;조경이;황영우;이경희;정광재;박동욱
    • 한국산업보건학회지
    • /
    • 제33권4호
    • /
    • pp.419-426
    • /
    • 2023
  • Objectives: This study aims to develop an Occupational Safety and Health (OSH) guide for the safe cleaning of contaminated machinery, equipment, and parts used in the electronics manufacturing process. Methods: A literature review, field investigations, and discussions were conducted. An initial draft of an OSH guide was developed and reviewed by experts with significant experience in maintenance work in the electronics manufacturing process in order to refine the guide. Results: Workers involved in cleaning processes with chemicals, solvents, and abrasive blasting can face exposure to a wide range of chemicals, abrasives, and noise. Identifying potential risks associated with each cleaning technique was an essential first step toward enhancing safety measures. The OSH guide comprises approximately eleven to twelve sections spanning 20-25 pages. It includes engineering and administrative protocols systematically organized to address the necessary actions before, during, and after cleaning tasks, depending on the technique. It is recommended that airline respirator masks be used in conjunction with an air purification system to ensure adherence to air quality standard "D" for atmosphere level. The use of an oil-free air compressor is advised, preferably a stationary model that does not rely on fuel sources like diesel. Conclusions: This OSH guide is designed to protect workers involved in maintenance activity in the electronics industry and aligns with global standards, such as those from the International Organization for Standardization (ISO) and Semiconductor Equipment and Material International, ensuring a higher level of safety and compliance.

도심용 eVTOL 항공기 전기추진시스템 기준 분석 및 안전성 확보 방안에 관한 연구 (A Study on the Certification Standard Analysis and Safety Assurance Method for Electric Propulsion System of the Urban eVTOL Aircraft)

  • 김주영;유민영;권혁록;길기남;공병호;나종화
    • 항공우주시스템공학회지
    • /
    • 제16권3호
    • /
    • pp.42-51
    • /
    • 2022
  • 도심환경에서 저공해/저소음으로 운항이 요구되는 eVTOL 항공기는 왕복행정엔진이나 터빈엔진과 같은 전통적인 추진시스템이 아닌 대부분 배터리를 이용한 전기추진시스템을 동력원으로 사용한다. 이에 따라 전기추진시스템에 대한 인증제도 마련 및 전기추진시스템의 안전성 확보방안이 중요한 이슈가 되고있다. 미국의 경우 전기추진시스템을 인증하기 위해 FAR Part 33에 준하는 특수기술기준을 발행하였고 유럽의 경우 전기추진시스템의 인증을 위해 다양한 특별조건을 제정하였다. 따라서 국내에도 미국, 유럽에 맞춰가며 eVTOL 항공기 전기추진시스템 기술기준에 대한 대비가 필요하다. 본 논문에서는 특별조건 중 전기/하이브리드 추진 시스템의 기술기준인 SC E-19를 분석하였고 기존 항공기 안전성 평가 절차인 ARP 4761에 항공기 수준에서 적용 되어야하는 SC E-19 기술기준을 적용시킴으로써 항공기에 장착하는 전기추진시스템의 안전성 확보 방안을 제안하였다. 마지막으로 Ehang 184 전기추진시스템의 사례연구를 통해 제안한 전기추진시스템의 안전성 확보 방안이 항공기 수준에서 적용 가능함을 확인하였다.

Performance Evaluation of a Driving Power Transmission System for 50 kW Narrow Tractors

  • Hong, Soon-Jung;Ha, Jong-Kyou;Kim, Yong-Joo;Kabir, Md. Shaha Nur;Seo, Young Woo;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • 제43권1호
    • /
    • pp.1-13
    • /
    • 2018
  • Purpose: The development of compact tractors that can be used in dry fields, greenhouses, and orchards for pest control, weeding, transportation, and harvesting is necessary. The development and performance evaluation of power transmission units are very important when it comes to tractor development. This study evaluates the performance of a driving power transmission unit of a 50 kW multi-purpose narrow tractor. Methods: The performance of the transmission and forward-reverse clutch, which are the main components of the driving power transmission unit of multi-purpose narrow tractors, was evaluated herein. The transmission performance was evaluated in terms of power transmission efficiency, noise, and axle load, while the forward-reverse clutch performance was evaluated in terms of durability. The transmission's power transmission efficiency accounts for the measurement of transmission losses, which occur in the transmission's gear, bearing, and oil seal. The motor's power was input in the transmission's input shaft. The rotational speed and torque were measured in the final output shaft. The noise was measured at each speed level after installing a microphone on the left, right, and upper sides. The axle load test was performed through a continuous equilibrium load test, in which a constant load was continuously applied. The forward-reverse clutch performance was calculated using the engine torque to axle torque ratio with the assembled engine and transmission. Results: The loss of power in the transmission efficiency test of the driving power unit was 6.0-9.7 kW based on all gear steps. This loss of horsepower was equal to 11-18% of the input power (52 kW). The transmission efficiency of the driving power unit was 81.5-89.0%. The noise of the driving power unit was 50-57 dB at 800 rpm, 70-77 dB at 1600 rpm, and 76-83 dB at 2400 rpm. The axle load test verified that the input torque and axle revolutions were constant. The results of the forward-reverse clutch performance test revealed that hydraulic pressure and torque changes were stably maintained when moving forward or backward, and its operation met the hydraulic design standards. Conclusions: When comprehensively examined, these research results were similar to the main driving power transmission systems from USA and Japan in terms of performance. Based on these results, tractor prototypes are expected to be created and supplied to farmhouses after going through sufficient in-situ adaptability tests.

VDL Mode-2 물리 계층 설계 및 성능 분석 (The Design and Performance Analysis of Physical Layer for VDL Mode-2)

  • 최준수;이한성;김태식;김인규;김현경
    • 한국항행학회논문지
    • /
    • 제11권1호
    • /
    • pp.17-23
    • /
    • 2007
  • 본 논문에서는 차세대 항공 데이터 통신에 사용되는 VDR(VHF Data Radio)의 물리계층을 국제규격에 만족하도록 설계하였다. VDR의 주파수 대역은 117.975~137MHz이고, CSMA(Carrier Sense Multiple Access) 다중 접속방식, D8PSK(Differential Eight Phase Shift Keyed), 25kHz의 채널 대역폭을 사용한다. VDR의 성능 요구 조건인 인접 채널 분리, 수신감도, 혼변조, 수신기의 동작영역, 송신기의 선형성, 불요 방사 전력을 선형 및 비선형 시뮬레이션을 통해 분석 하고, 제작을 위한 방향을 제시하였다. 설계 결과 송신부는 Po1dB보다 5dB 낮은 점에서 사용해야하고, 중간 주파수를 45MHz 선정하여 스퓨리어스 발생을 억제해야한다. 수신부는 잡음지수 4.5dB, Es/No 27.52dB로 설계 되었고, 혼변조 성분을 최소화하기위해 저 잡음 증폭기의 IIP3를 +10dBm 이상을 사용하고, 혼합기의 절연특성이 30dB이상이 되어야한다.

  • PDF

도시형생활주택의 공급현황 및 거주특성 연구 - 서울시 공급사례를 중심으로 - (A Study of Supply Patterns and Residential Characteristics of Urban-type Housing in Seoul)

  • 이재수;성수연;이동훈
    • 한국주거학회논문집
    • /
    • 제25권2호
    • /
    • pp.1-9
    • /
    • 2014
  • This study investigates supply patterns and residential characteristics of the Urban-type Housing in Seoul. There have been 3,336 buildings and 71,790 housing units approved until the end of 2012. One-room apartments and small units less than 30 $m^2$ of residential area amount to 81% and 82% of total units, respectively. Major findings are as follows. First, single- and two-person households less than 30 years of age are mostly lived in the housing. Respondents are mainly professional and white-collar (43%) and service and sales workers (27%). Most of them are mid-income classes (67%), which is twice more than that of single- and two-person households in Seoul. They pay 672 thousand won in rent more than average rent of mid-income class. The rent to income ratios are 29.9% for single households and 24.5% for two-person households, which are higher than that of mid-income bracket. Third, their satisfaction level is relatively high in internal environment and access to public service facilities, but not in external environment and community service facilities. They are satisfied with security and daylight, walking and safety, access to public transport and parking space, but not with noise and vibration, natural environment, access to park and cultural and sports facilities, and most community service facilities. It is necessary to reexamine the articles of deregulation and prepare design standards while considering different housing and locational types.