• Title/Summary/Keyword: Noise reducing device

Search Result 58, Processing Time 0.054 seconds

A Study on the Performance Prediction and Evaluation of Scale Down Noise Reducing Device on the Top of Noise Barrier (축소모형 방음벽 상단장치의 성능예측 및 평가에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Jang, Kang-Seok;Hong, Byung-Kook
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2844-2851
    • /
    • 2011
  • The purpose of this study is to set up an acoustic prediction technique and to perform the IL test of scale down noise reducing device for the development of the noise reducing device as the development of 400km/h class high speed train. First of all, the IL prediction of noise reducing device was performed with the 2D BEM method. And the noise test of scale down noise reducing device in anechoic chamber was performed for the verification of acoustic prediction technique and IL performance evaluation. As the results, the acoustic prediction technique for the development of noise reducing device was verified because the averaged IL difference between prediction and test is in 2dB(A). And the measured IL value of noise reducing device is less than 2dB(A), and additional IL with polyester absorption material is increased about 0.5dB(A).

  • PDF

Patent Analysis for Noise Barrier and Noise Reducing Device (방음벽 및 방음장치 특허 동향 분석)

  • Cho, Jun-Ho;Koh, Hyo-In;Kim, Heung-Sup
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1975-1981
    • /
    • 2010
  • In this study, the patent trends for noise barrier and noise reducing device have been analyzed, for the development of adaptive noise barrier according to the transmission characteristics of railway noise. Using patent search engine, keyword searching for patents after 1980 in Korea was performed. The first 667 patents details were reviewed for the extraction core(ie, key) patents. From this review, finally 70 patents were built as DB. From this analysis of core patents, system requirements for development of noise reducing device were obtained.

  • PDF

Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(3) - Suggestion of Test and Estimation Method - (방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(3) - 시험 및 평가방법의 제안 -)

  • Kim, Chul-Hwan;Chan, Tae-Sun;Kang, Hee-Man;Jeon, Ki-Seong;Kim, Dong-Joon;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.496-499
    • /
    • 2008
  • The noise reducing devices installed on the noise barrier have been developed in many shapes and ways to reduce noise around road traffic areas. In this study, test and estimation method for the noise reducing device witch installed on the top of a noise barrier was suggested. For this, the authors have considered sound power flow around the device and sound pressure levels for the far field area. To estimate the area effect behind the barrier, area average of noise pressure level difference divided by two area, upper and bellow the sight-line. Comparing the attenuation difference of these areas, the tendency of noise reduction effect was studied according to type of noise reducing devices. Compared with noise shielding efficiency of the devices that using equivalent height of a simple barrier calculated by the SoundPlan, the commercial environment noise simulation software.

  • PDF

Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(I) - Estimation by Sound Intensity - (방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(I) - 음향인텐시티에 의한 평가 -)

  • Kim, Chul-Hwan;Chang, Tae-Sun;Lee, Ki-Jung;Kang, Hee-Man;Lee, Soo-Il;Chang, Seo-Il;Kim, Bong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1053-1056
    • /
    • 2007
  • The acoustical performance of noise reducing devices installed on the top of a noise barrier were tested by small-scale outdoor tests. Noise measurements before and after installation of the devices were carried out using sound intensity methods. It is well known that the sound intensity method can specify the strength and directivity of sound, and it is convenient to consider the feature of sound around a noise barrier. The noise reduction effect of each edge device was evaluated using the difference between the input and output sound power levels calculated from sound intensities. It was investigated that each device had different efficiency in the shadow zone, while there was no significant difference between edge devices in the illuminated zone.

  • PDF

Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(2) - Estimation by Sound Pressure Level - (방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(2) - 음압레벨에 의한 평가 -)

  • Kim, Chul-Hwan;Chang, Tae-Sun;Lee, Ki-Jung;Kim, Dong-Joon;Jeong, Tae-Ryang;Chang, Seo-Il;Kim, Bong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1125-1128
    • /
    • 2007
  • In order to improve the acoustic performance of a noise barrier without increasing its height, various type of acoustic devices are suggested but, there is no proper method to estimate the performance in Korea. For this, an outdoor test facility was established in Expressway and Transportation Technology Institute(ETTI) of Korea Expressway Corporation for testing the acoustical performance of noise reducing devices installed on the top of a noise barrier. Noise measurements before and after installation of the noise reducing devices were carried out by using sound pressure level for long distance range from the barrier, from 10m to 40m. For considering the directivity effects of noise reducing devices, multivariate regression analysis was attempted.

  • PDF

A study on the development of noise reducing device installed on the top of noise barrier for 400km/h class high-speed railroad (400km/h급 고속철도 소음저감용 방음벽 상단장치 개발에 관한 연구)

  • Yoon, Je Won;Kim, Yonng Chan;Jang, Kang Seok;Hong, Bynng Kook;Eum, Young-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.708-713
    • /
    • 2013
  • 본 연구의 목적은 400km/h 급 고속철도 소음저감용 방음벽 상단장치를 개발하기 위함이다. 이를 위해 우선 현장에서의 소음측정을 통한 400km/h 급 고속철도(HEMU) 및 300km/h 급 KTX의 주파수특성을 분석하였다. 그리고, 해석적 기법(BEM) 및 시작품 제작을 통한 실내실험을 수행하여 3dB(A) 이상의 소음을 저감시킬 수 있는 상단장치를 설계하였다. 마지막으로, 상단장치 시작품을 제작하여 옥외시험실에서의 성능시험을 수행하였으며, 고속철도의 주파수특성을 반영한 상단장치 설치 전후의 감음량을 평가하였다.

  • PDF

Development on a Vibration Reducing Element for the Large Transformers (대형 변압기 방진장치개발)

  • Lee, Jun-Shin;Lee, Wook-Ryun;Son, Seok-Man;Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.259-262
    • /
    • 2005
  • The large transformers used in the electric power company become targets of public complaints because of those characteristics generating high-level noise. Reducing vibration level is the basis of noise control for the large transformers. For this reason, a vibrating reducing element is developed for the large transformers with a sub-element enduring seismic movement. Large attenuation of vibration is achieved by applying the element to the large transformers in a substation.

  • PDF

Analysis of Noise Reduction Performance for Noise Cut Transformer (Noise Cut Transformer의 노이즈 억제성능 분석)

  • Lee, Jae-Bok;Huh, Chang-Su;Lee, Ki-Chul;Myung, Sung-Ho;Ha, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1784-1786
    • /
    • 1996
  • It is necessary to eliminate the broad band noise which frequency is in a few kHz to MHz in the AC line to supply the power to electrical and electronic control equipments. Because this kind of noise could damage the device or could be a source of malfunction, many devices like a filter and surge suppressor are developed to cut off the noise. But those device could not disconnected from the power line, so it remain some problem and on be used in limited area, In this paper, we present performance test results NCT(noise Cut Transformer) with excellent performance for reducing the high frequency noise and surge existing in the power line.

  • PDF