• Title/Summary/Keyword: Noise protection

Search Result 341, Processing Time 0.028 seconds

A study on Traffic Noise control by the Environmental facilities around Roadway (도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구)

  • Sul Jeung Min;Chung Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.3 no.2 s.5
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF

PLANNING AGNAINST NOISE IN HONG KONG

  • Wong, Sam W. H.;Lui, Aaron S.W.;Lau, K.K.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.656-661
    • /
    • 1994
  • The impacts of road traffic noise in Hong Kong are pervasive. About one million peoople are affected by road traffic noise at levels higher than a standardd recommended fro planning of new developments. The Environmental Protection Department of Hong Kong has promulgated a set of planning standards and guidelines for reference of planners, engineers and architects in their preparation of land use proposals which include road and residential developments. This paper will describe, in connection with road traffic noise in Hong Kong, the planning objectives, the various practicable mitigation measures available to a high density modern city, and the achievements through conscientious planning efforts made over the past years.

  • PDF

Feedback Active Noise Control Based Voice Enhancing Ear-Protection System

  • Moon, Seong-Pil;Chang, Tae-Gyu
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1627-1633
    • /
    • 2017
  • This paper proposes a voice enhancing ear-protection system which is based on feedback active noise control(FBANC). The proposed system selectively suppresses the background noise and preserves the talking voice by controlling the adaptive algorithm with the voice activity period detection module. The noise reduction performance of the proposed noise canceling algorithm is analytically derived for the two key performance affecting parameters, i.e., electro-acoustic coupling distance and noise bandwidth. The proposed system is also implemented with a floating-point DSP system and its performance is experimentally tested to compare with the analytically derived results. The achieved levels of noise reduction for the three different noise bandwidths cases, i.e., 10Hz, 50Hz, and 90Hz, are high to show 17.05dB, 10.54dB and 8.99dB, respectively. The feasibility of the proposed system is also shown by the peak noise reduction achieved more than 25dB while preserving the voice component in the frequency range between 200-800Hz.

The Research of Safety Effects by using a Hearing Protection(Ear Plug) in the Military (군대 청력 보호구(귀마개) 사용 및 착용 안전효과 실태조사)

  • Hwang, Sung Ho;Joo, Myo Kyoung;Park, Jae Bum
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.103-106
    • /
    • 2013
  • During a military service, noise has unusual characteristics, and constitutes a serious hazard to hearing of military servicemen. The purpose of this study is to understand the use of hearing protection and to assess the safety effects of hearing protection by using a ear plug in military. A total of 208(the army : 101, an air force : 107) serviceman were studied utilizing a questionnaire to know how many serviceman use the hearing protection and a total of 202(the army : 110, an air force : 92) serviceman were also studied using a ear fit validation device to assess the safety effects of hearing protection by using a ear plug. The results showed that the army have low used of hearing protection than an air force because of the low frequency of the noise exposure in the army. Personal attenuation rate was increased with 8 dB after fitting education. Therefore, it is recommended that use of proper hearing protection and fitting education was more suitable for military servicemen who were being exposed of the noise in domestic military.

Subjective Responses to the Anti-noise Effect According to Different Types of Soundproof-protector (방음 보호구 종류별 소음저감 효과에 대한 주관적 반응)

  • Kim, Dae-Goon;Kim, Jae-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.10
    • /
    • pp.891-899
    • /
    • 2010
  • Since the working machine generates an excessive loud noise as much as its use-purpose and dimension, those damages are occurring to the exposed workers such as unpleasant sense, stress and occupational hearing-impaired. Accordingly, as one of the measures for prevention such loud noise, various soundproof protection tools were developed. However, such soundproof protection tools were presented the physical measured value only, it is real state that the psychological study result with regard to the soundproof effect which the workers are actually feeling, is not existing. On such point of view, with the object on the typical earplugs and earcaps among the soundproof protection tools, this study has ever tried a subjective evaluation about the degree of soundproof effect through Psycho-acoustics experiment. It is considering that such study result could be utilized as the useful material when establishing the soundproof measure for the workers in the future.

AC Modeling of the ggNMOS ESD Protection Device

  • Choi, Jin-Young
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.628-634
    • /
    • 2005
  • From AC analysis results utilizing a 2-dimensional device simulator, we extracted an AC-equivalent circuit of a grounded-gate NMOS (ggNMOS) electrostatic discharge (ESD) protection device. The extracted equivalent circuit is utilized to analyze the effects of the parasitics in a ggNMOS protection device on the characteristics of a low noise amplifier (LNA). We have shown that the effects of the parasitics can appear exaggerated for an impedance matching aspect and that the noise contribution of the parasitic resistances cannot be counted if the ggNMOS protection device is modeled by a single capacitor, as in prior publications. We have confirmed that the major changes in the characteristics of an LNA when connecting an NMOS protection device at the input are reduction of the power gain and degradation of the noise performance. We have also shown that the performance degradation worsens as the substrate resistance is reduced, which could not be detected if a single capacitor model is used.

  • PDF

An Investigation of the Noise in Ship Engine-Room and Cabins for Hearing Protection (I) (청력보호를 위한 선박 기관실 및 선실소음의 조사(I))

  • Yu, Y.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.97-103
    • /
    • 1999
  • As the noise of ship engine room is too loud, the engineer who works in a ship engine-room has the trouble of hearing. In this paper deals the investigation of the noise of ship engine room and cabins with the internationally allowable noise exposure level and noise exposure time. Recently, the problem of engine-room noise is more serious because of shipowner wants to make small number and larger size of cylinder. Therefore, engineers work in a ship engine-room for a long time have the trouble of hearing when they are exposed the high noise level. In this study, two kinds of vessels were used to investigate the noise of engine room, engine-control room, bridge, offices and cabins. As criteria of sound levels, A-weighted sound pressure level and octave band pressure level were used.

  • PDF

A Study on the Knowledge, Attitude and the Preventive Behavior of Noise of Workers Exposed to the Harmful Noise (일 소음작업장 근로자들의 소음에 대한 인식 및 태도, 예방행위에 관한 연구)

  • Kim, Eun-Hee;Kim, Tae-Kyung;Jung, Hee-Young;Kwon, Su-Ja
    • Research in Community and Public Health Nursing
    • /
    • v.16 no.1
    • /
    • pp.59-67
    • /
    • 2005
  • This study was to investigate knowledge, attitude and the preventive behaviour of noise of workers exposed to harmful noise and to provide primary data for noise-exposed workers' hearing conservation and the prevention of noise induced hearing loss. Method: The subjects were 104 workers who participated voluntarily in the questionnaire. The instrument used in this study was knowledge, attitude and practice on noise-induced hearing loss tool by Rhee & Yi (1996). The data were collected from August to September, 2002 with a self-administered questionnaire. Data were analyzed by SPSS 10.0 win program for finding frequency, percentage, mean, standard deviation, t-test, and ANOVA. Results: The average age of workers was 35.9 and the current average year of working at the noise place was $5{\sim}$10 years. In the group of previous noise-exposed workers, they showed significant difference in preventive behaviors (t=4.087, p=.048). In the group of current noise-exposed workers, they showed significant difference in recognition and attitude of noise(F=4.707, p=.004). Also, the duration of wearing ear protection equipment(t=2.383, p=.019), the feeling of wearing ear protection equipment(F=3.602, p=.031) and comfortable sense of wearing ear protection (F=3.919, p=.023) was significant in the preventive behaviour of noise. Conclusion: Considering the results above, we can recognize that there are close relations among the knowledge, attitude and the preventive behaviour of noise. Therefore, it is necessary to develop education - programs for noise-exposed workers' better understanding of noise and preventive behaviors

  • PDF

Effects of Hearing Protection Methods and Noise Directions on Bone-Conduction Sensitivity (청력보호구 종류와 소음 방향에 따른 골전도 민감도의 영향)

  • Han, Woojae;Yu, Jyaehyoung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.423-429
    • /
    • 2013
  • The present study aimed to find the most sensitive placement of the skull to perceive speech through the bone vibrator in various protection methods while being exposed to noise. Twenty young normal-hearing adults (10 male and 10 female) participated in the study. As stimulus, Korean spondee words were presented via one of five skull locations (i.e., jaw angle, condyle, temple, mastoid, and vertex), while the participants wore one of four protection methods (i.e., ear form, ear plug, ear muff, and ear form and muff together) against white noise in one of four noise directions (i.e., 0, 90, 180, 270 degrees). The results showed: 1) there was a significant difference among the five skull locations with condyle being the most sensitive placement; 2) there was a significant difference among the four protection methods, with the ear form plus ear muff condition (or dual protection) providing the lowest threshold; 3) when exposed to noise from 90 degrees, the significantly lowest threshold was found; 4) there was no significant difference in results by gender. The pattern of results suggests that the communicative condition via the condyle bone conduction and the dual protection of the air conduction under any noise direction might be ideal for preventing noise-induced hearing loss, although further studies should be undertaken in this area.

Design of Small Acoustic Filter for ITE Type Noise Protector (ITE 타입의 소음 차폐기용 소형 음향 필터의 설계)

  • Lee, Yun-Jung;Kim, Pil-Un;Chang, Yong-Min;Lee, Sang-Heun;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.479-487
    • /
    • 2004
  • The prevention of noise induced hearing loss is very important, because there is no treatment for it. There are some kinds of devices for hearing protection, and those are effective in preventing a noise induced hearing loss. However, people often resist the use of hearing protection devices because it is difficult to have a conversation. Therefore, a hearing protection device is must effective not only in hearing protection but also in preserving communication ability. In this paper, we proposed a small acoustic filter for ITE type noise protector to solving the problem about the difficulties of conversation. That is applied a principle of acoustic filters that have been used for a muffler of automobiles, guns, and etc. To find out the sound transmission characteristic at the eardrum, we regarded an acoustic filter and external ear canal as a coupled system. So, we simulated the coupled system with OrCad, and experimented with a designed acoustic filter and a 2 cc coupler which has the same transmission characteristic as the external ear canal has. We confirmed that it is possible to adjustment acoustic transmission characteristics through simulation of electrical model for acoustic filter and external ear and experiments using designed small acoustic filters.