• 제목/요약/키워드: Noise power spectrum (NPS)

검색결과 41건 처리시간 0.026초

3.0T 자기공명영상을 이용한 잡음전력스펙트럼 특성 평가 (Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T)

  • 민정환;정회원;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.31-37
    • /
    • 2021
  • This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.

선형가속기의 시간에 따르는 전자조사문영상기구의 잡음전력스펙트럼 비교 평가 (Evaluation of Comparison of Noise Power Spectrum according to the Time of Using Electronic Portal Imaging Device (EPID) for LINAC System)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권2호
    • /
    • pp.117-123
    • /
    • 2024
  • This study was to assessment of quality assurance (QA) and noise characteristics of Noise Power Spectrum (NPS) according to the time of by using electronic portal imaging device (EPID) for LINAC (Linear Accelerator). LINAC device was (Varian ClinacR iX LINAC, USA) used and the were 40 × 30 cm2 of detector size were 1024 × 768 photo-electric diode array size. Signal could be obtained the K-space image of white noise images for NPS and we used to Overlap, Non-Overlap, Out of Penumbra, Flatness, Symmetry, Symmetry Rt, Lt methods. The 2013s NPS image Out of Penumbra quantitatively value more than 2013s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. Thus, the 2022s NPS image Out of Penumbra quantitatively value more than 2022s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. The assessment of comparison of white noise for NPS image noise and intensity of this study were to that should be used efficiently of the LINAC EPID detector system for Overlap method for International Electro-technical Commission (IEC).

간접평판형 검출기에서 국제전자기술위원회 기준을 통한 잡음전력스펙트럼 비교 연구 (Comparison of Noise Power Spectrum in Measurements by Using International Electro-technical Commission Standard Devices in Indirect Digital Radiography)

  • 민정환;정회원;김기원;권경태;정재용;손진현;김현수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.457-462
    • /
    • 2018
  • The purpose of this study was to compare image quality of indirect digital radiography (IDR) system using the International Electro-technical Commission standard (IEC 62220-1), and to suggest the analysis of noise power spectrum (NPS) which were applied to IEC 62220-1 in medical imaging. In this study, Pixium 4600 (Trixell, France) which is indirect flat panel detector (FPD) was used. The size of image receptor (IR) is $7{\times}17$ inch (matrix $3001{\times}3001$) which performed 14bit processing and pixel pitch is $143{\mu}m$. In IEC standard, NPS evaluation were applied to RQA3, RQA5, RQA7 and RQA9. Because of different radiation quality, each region of interesting (ROI) were compared. The results of NPS indicated up to $3.5mm^{-1}$ including low Nyquist frequency. RQA5 indicated the lowest NPS and the others indicated higher NPS results relatively. NPS result of ROI a38 was higher than ROI a92 and this result indicated that there are more noise in left (cathode) than right (anode). This study were to evaluate NPS by using different radiation quality and setting the each ROI, and to suggest the quantitative methods of measuring NPS.

자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가 (Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

The Noise Power Spectrum in Heavy Ion CT Based on Measurement of Residual Range Distribution

  • Yasuda, Naruomi;Abe, Shinji;Nishimura, Katsuyuki;Tomita, Tetsuya;Sato, Hitoshi;Muraishi, Hiroshi;Kanzaki, Takayuki;Inada, Tetsuo;Fujisaki, Tatsuya
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.228-230
    • /
    • 2002
  • The relative electron density resolution was discussed by the noise power spectrum (NPS) in the heavy ion CT image. The heavy ion beam $\^$12/C accelerated up to 400MeV/u by RIMAC was used in this study. The two-dimensional (2-D) NPS in the CT image was obtained from the one-dimensional (1-D) NPS of the measured residual range distribution of water phantom for single projection, and the noise variance in the CT image was calculated from 2-D NPS. The technique used in the reconstruction was the filtered back-projection method with Shepp-Logan filter. The calculated value suggests the result of our previous works using the density resolution phantom, assuming that the relative electron density resolution is twice the standard deviation. Therefore, the estimation of the noise in CT images by 2-D NPS obtained the measured residual range distribution is the useful method.

  • PDF

CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가 (Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System)

  • 정회원;민정환;김정민;박민석;이광용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.109-117
    • /
    • 2012
  • 간접형 CsI flat-panel detector (FPD)의 해상특성(modulation transfer function, MTF), 잡음특성(Wiener spectrum or noise power spectrum, NPS), 양자검출효율(detective quantum efficiency, DQE)을 측정하고 평가하기 위하여 본 실험을 실시하였다. IEC에서 권고한 실험방법을 따라 RQA3, RQA5, RQA7, RQA9의 방사선 선질을 사용하였다. MTF는 egde법을 사용하였다. Wiener spectrum은 조사 영역내에서 획득한 영상의 푸리에 변화를 통하여 구하였다. DQE는 MTF, WS(NPS), X선 입력 및 입력 광자량을 사용하여 평가하였다. 특성곡선은 RQA3와 RQA5, RQA7, RQA9과는 차이가 발생하였다. MTF는 X선 선질과는 상관없이 일정하였다. WS(NPS)은 X선 양이 증가 할수록 감소하였으며, RQA3, RQA5, RQA7, RQA9순으로 감소하였다. DQE는 1mR에서 가장 우수했으며, RQA3, RQA5, RQA7, RQA9순으로 감소하였다. FPD의 물리적 영상 특성을 입력 선질에 따라 다를 수 있다. 본 연구를 통하여 디지털 방사선 시스템의 바르게 사용하려면 FPD의 물리적 영상 특성을 아는 것이 중요함을 인식하게 되었다.

디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구 (Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography)

  • 김호경;조민국
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.

디지털진단의료영상 화질평가 프로그램 개발 (Development of Image Quality Evaluation Program for Digital Diagnostic Radiography)

  • 강보선
    • 한국방사선학회논문지
    • /
    • 제2권2호
    • /
    • pp.5-10
    • /
    • 2008
  • 최근의 진단의료용 방사선영상은 대부분 디지털영상으로 변환되었으나, 영상획득을 위한 조사조건 등 영상화질에 영향을 미치는 요소들에 관련하여서는 여전히 대부분 필름-스크린 시스템의 기준을 그대로 따르고 있으며, 실정이다. 뿐만 아니라 획득된 디지털영상에 대한 객관적인 화질평가 또한 임상에서 적용되고 있지 않은 실정이다. 본 연구에서는 디지털영상의 화질을 평가함에 있어 기본이 되는 요소인 화질의 균일성, NPS(noise power spectrum), MTF(modulation transfer function), NEQ(noise equivalent quanta) 등에 대한 평가를 임상에서 활용할 수 있도록 사용자 친화적인 윈도우 환경의 디지털영상화질 평가 프로그램을 MatLab을 이용하여 개발하였다.

  • PDF

산란선이 간접변환방식 엑스선 검출기의 신호 및 노이즈 특성에 미치는 영향에 관한 연구 (A Study on the Scatter X-ray Signal and Noise Characteristics of Indirect Conversion-Type Detector for Radiography)

  • 김준우
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.345-353
    • /
    • 2021
  • 디지털 래디오그라피 이미징 시스템으로 환자의 병변 진단에 있어 도움을 줄 수도 있으나 인체에 입사되는 엑스선이 물질과의 상호작용으로 인해 산란선이 발생되면 엑스선 영상의 신호 및 노이즈 특성에 영향을 미치게 된다. 인체를 폴리메틸메타아크릴레이트(polymethyl methacrylate, PMMA)로 간주하고 PMMA에서 발생되는 산란선이 엑스선 영상에 미치는 특성을 관찰하기 위해 공간 영역에서 신호 및 노이즈 분석뿐만 아니라 공간주파수 영역에서 노이즈-파워 스펙트럼(noise-power spectrum, NPS) 그리고 제로주파수에서 양자검출효율(detective quantum efficiency, DQE)을 계산하였다. PMMA 두께 증가에 따라 신호는 감소, 노이즈는 증가하였으며 전반적인 공간주파수에서 노이즈-파워 스펙트럼의 저하가 확인되었다. 이러한 특성을 바탕으로 제로주파수 성능 또한 저하되는 결과를 보였다. 간접변환방식 검출기의 산란선에 의한 제로주파수 성능을 보다 정량적으로 분석하기 위해 몬테칼로 시뮬레이션과의 비교분석이 이루어져야 할 것이다.

방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교 (Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 손순룡;최관우;정회원;권경태;김기원;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.99-105
    • /
    • 2016
  • 잡음전력스펙트럼 (noise power spectrum, NPS)는 noise 진폭의 측정과 균일한 방사선 영역으로부터 획득된 영상의 품질에 가장 일반적인 방법 중 하나이다. 이 연구의 목적은 megavoltage X-ray 에너지를 사용하여 다른 잡음 전력스펙트럼 방법론들을 비교하는 것이다. 진단 영역에서의 잡음전력스펙트럼 평가 방법들은 국제 전기 규격 international electro-technical commission(IEC 62220-1) 기준을 사용하여 치료 영역에 적용되었다. 우리가 사용한 전자포털영상장치(electronic portal imaging device, EPID)는 Varian TrueBeam$^{TM}$, Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT 그리고 Varian Clinac$^R$ iX aS1000이었다. 잡음전력스펙트럼의 관심영역을 측정하기 위해, 우리는 겹침 (overlapping), 비겹침 (non-overlapping), 평탄도 (flatness), 반음영 (penumbra) 4가지 인자를 사용하였다. 결과적으로는 Siemens BEAMVIEW$^{PLUS}$, Varian TrueBeam$^{TM}$ flattening filter, Varian Clinac$^R$ iX aS1000, Varian TrueBeam$^{TM}$ flattening filter free에서의 잡음 (noise) 분포는 기존의 첫번째, 두번째, 세번째 실험방법보다는 Elekta iViewGT보다 현격하게 높은 noise 분포가 나타남을 알 수 있다. 이번 연구는 다양한 인자들이 잡음전력스펙트럼의 megavoltage imaging (MVI)영상에서 MVI영역에서 잡음전력 스펙트럼의 기준의 방법론으로 사용되어질 수 있다는 것을 보여주었다.