• 제목/요약/키워드: Noise Standard

검색결과 1,475건 처리시간 0.029초

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) via Public Facilities PM2.5, Korea (II)

  • Kim, Ho-Hyun;Lee, Geon-Woo;Yang, Ji-Yeon;Jeon, Jun-Min;Lee, Woo-Seok;Lim, Jung-Yun;Lee, Han-Seul;Gwak, Yoon-Kyung;Shin, Dong-Chun;Lim, Young-Wook
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권1호
    • /
    • pp.35-47
    • /
    • 2014
  • The purpose of the study is to evaluate the pollution level (gaseous and particle phase) in the public facilities for the PAHs, non-regulated materials, forecast the risk level by the health risk assessment (HRA) and propose the guideline level. PAH assessments through sampling of particulate matter of diameter < 2.5 ${\mu}m$ ($PM_{2.5}$). The user and worker exposure scenario for the PAHs consists of 24-hour exposure scenario (WIES) assuming the worst case and the normal exposure scenario (MIES) based on the survey. This study investigated 20 PAH substances selected out of 32 substances known to be carcinogenic or potentially carcinogenic. The risk assessment applies major toxic equivalency factor (TEF) proposed from existing studies and estaimates individual Excess Cancer Risk (ECR). The study assesses the fine dusts ($PM_{2.5}$) and the exposure levels of the gaseous and particle PAH materials for 6 spots in each 8 facility, e.g. underground subway stations, child-care facilities, elderly care facilities, super market, indoor parking lot, terminal waiting room, internet caf$\acute{e}$ (PC-rooms), movie theater. For internet caf$\acute{e}$ (PC-rooms) in particular, that marks the highest $PM_{2.5}$ concentration and the average concentration of 10 spots (2 spots for each cafe) is 73.3 ${\mu}g/m^3$ (range: 6.8-185.2 ${\mu}g/m^3$). The high level of $PM_{2.5}$ seen in internet cafes was likely due to indoor smoking in most cases. For the gaseous PAHs, the detection frequency for 4-5 rings shows high and the elements with 6 rings shows low frequency. For the particle PAHs, the detection frequency for 2-3 rings shows low and the elements with 6 rings show high frequency. As a result, it is investigated that the most important PAHs are the naphthalene, acenaphthene and phenanthrene from the study of Kim et al. (2013) and this annual study. The health risk assessment demonstrates that each facility shows the level of $10^{-6}-10^{-4}$. Considering standards and local source of pollution levels, it is judged that the management standard of the benzo (a)pyrene, one of the PAHs, shall be managed with the range of 0.5-1.2 $ng/m^3$. Smoking and ventilation were considered as the most important PAHs exposure associated with public facility $PM_{2.5}$. This study only estimated for inhalation health risk of PAHs and focused on the associated cancer risk, while multiple measurements would be necessary for public health and policy.

IC-임베디드 PCB 공정을 사용한 DVB-T/H SiP 설계 (Design of DVB-T/H SiP using IC-embedded PCB Process)

  • 이태헌;이장훈;윤영민;최석문;김창균;송인채;김부균;위재경
    • 대한전자공학회논문지SD
    • /
    • 제47권9호
    • /
    • pp.14-23
    • /
    • 2010
  • 본 논문에서는 유럽에서 사용되는 이동형 디지털 방송인 DVB-T/H 신호를 수신 및 신호처리 가능한 DVB-T/H SiP를 제작하였다. DVB-T/H SiP는 칩이 PCB 내부에 삽입될 수 있는 IC-임베디드 PCB 공정을 적용하여 설계되었다. DVB-T/H SiP에 삽입된 DVB-T/H IC는 신호를 수신하는 RF 칩과 어플리케이션 프로세서에서 활용할 수 있도록 수신된 신호를 변환하는 디지털 칩 2개를 원칩화한 모바일 TV용 SoC 이다. SiP 에는 DVB-T/H IC를 동작하기 위해 클럭소스로써 38.4MHz의 크리스탈을 이용하고, 전원공급을 위해 3MHz로 동작하는 DC-DC Converter와 LDO를 사용하였다. 제작된 DVB-T/H SiP는 $8mm{\times}8mm$ 의 4 Layer로 구성되었으며, IC-임베디드 PCB 기술을 사용하여 DVB-T/H IC는 2층과 3층에 배치시켰다. 시뮬레이션 결과 Ground Plane과 비아의 확보로 RF 신호선의 감도가 개선되었으며 SiP로 제작하는 경우에 Power 전달선에 존재하는 캐패시터와 인덕터의 조정이 필수적임을 확인하였다. 제작된 DVB-T/H SiP의 전력 소모는 평균 297mW이며 전력 효율은 87%로써 기존 모듈과 동등한 수준으로 구현되었고, 크기는 기존 모듈과 비교하여 70% 이상 감소하였다. 그러나 기존 모듈 대비평균 3.8dB의 수신 감도 하락이 나타났다. 이는 SiP에 존재하는 DC-DC Converter의 노이즈로 인한 2.8dB의 신호 감도 저하에 기인한 것이다.

5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구 (The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance)

  • 정해조;김희중;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.98-106
    • /
    • 2007
  • 2005년 6월 연세의료원 세브란스병원에서는 진단목적으로 20대의 5 mesa 화소 Totoku ME511L 평판 LCD 표시장치를 추가하여 PACS를 확장하였다. 20대의 Totoku ME511L 표시장치를 대상으로 반사, 휘도 반응, 휘도 공간 의존, 분해능, 잡음, 베일링 그레어, 그리고 색도 항목에 대하여 AAPM TG 18보고서에 기준하여 정량적인(또는 시각적인) 인수검사를 실시하였다. 측정에 사용된 장치는 색도를 측정할 수 있는 만원경식 휘도계, 조도계, 반사 측정에 필요한 빛 선원, 빛 차단 장치, 그리고 TG18 테스트 패턴들이었다. 선택된 8대의 표시장치에 대한 평균 확산 반사계수($R_d$)는 $0.019{\pm}0.02sr^{-1}$이었다. 휘도 반응 검사에서, 휘도비(LR), 최대 휘도 변이($L_{max}$), 그리고 최대 대조도 반응 변이는 각각 $550{\pm}100,\;2.0{\pm}1.9%$, 그리고 $5.8{\pm}1.8%$이었다. 휘도 균일도 검사에서, 최대 휘도 변이는 TG18-UNL10 테스트 패턴의 10% 휘도에 대하여 $14.3{\pm}5.5%$이었다. 분해능 측정은 휘도 측정법으로 수행하였으며 중심에서 퍼센트 휘도(${\Dalta}L$)는 $0.94{\pm}0.64%$이었다. 시각적인 방법의 잡음측정의 모든 경우에서, 중앙 및 주위 4사분면에서 가장 작은 것을 제외하고 15개의 모든 정사각형의 표적을 인식할 수 있었다. 글레어 비(GR)은 $12,346{\pm}1,995$이었다. 최대 색도 균일도 지표(D)는 $0.0025{\pm}0.0008$이었다. 또한 국내 실정에 적합한 진단용 표시장치의 정도관리 가이드라인 연구 결과를 제시하였다. 모든 인수검사 결과는 AAPM TG18 보고서 기준에 포함되어 진단 목적으로 사용하기에 적합하였다. 결론으로 인수검사는 표시장치가 진단에 사용하기에 적합한 성능임을 알려줄 뿐만 아니라 정도관리의 가이드라인, 최적 판독 환경, 그리고 표시장치의 교체시기를 결정하여주는 중요한 역할을 할 수 있다.

  • PDF

임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발 (Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner)

  • 김은주;김대홍;이상우;허단;이영한;서진석
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권1호
    • /
    • pp.52-58
    • /
    • 2014
  • 목적: 임상용 MRI에서 마우스 종양의 pH 측정을 위한 $^1H-^{31}P$ RF 코일 시스템을 개발하고 팬텀을 이용하여 pH 값의 정확도를 시험하고자 한다. 대상과 방법: 마우스 종양 연구를 위한 표면형 $^1H$$^{31}P$ radio frequency (RF) 코일을 개발하였다. 두 코일을 서로 수직이 되도록 설치하여 두 코일간의 상호인덕턴스를 0으로 하였다. 다양한 pH 값을 가진 팬텀으로부터 $^{31}P$ MR 스펙트럼을 얻어 Henderson-Hasselbalch equation을 이용하여 pH를 구하였다. $^{31}P$ 스펙트럼으로부터 얻은 pH값은 pH meter를 사용하여 직접 구한 pH값과 비교한다. 결과: $^1H-^{31}P$ RF 코일 상호간 coil coupling (S12)은 각각 -73.0, -62.3 dB로 충분히 분리 되었다. 균일한 팬텀으로부터 얻은 $^1H$ 영상의 signal-to-noise ratio (SNR)는 약 300 이상이며, in vivo 고해상도 마우스 영상을 얻을 수 있었다. $^1H$ 신호가 분리된 $^{31}P$ MR 스펙트럼으로부터 얻은 pH값은 pH meter로 직접 측정하여 얻은 값과 약 97% 상관관계를 가졌다. 결론: 본 연구에서 개발한 임상 MRI 장비용 $^1H-^{31}P$ RF 코일 시스템으로부터 정확한 pH를 구할 수 있었다. 본 코일 시스템은 31P 이외의 다른 핵 MRS 혹은 MRI에 적용 가능할 것으로 기대된다.

시료 전처리 방법이 근적외선분광법을 이용한 옥수수 사일리지의 화학적 조성분 평가에 미치는 영향 (Effect of Sample Preparations on Prediction of Chemical Composition for Corn Silage by Near Infrared Reflectance Spectroscopy)

  • 박형수;이종경;이효원;황경준;정하연;고문석
    • 한국초지조사료학회지
    • /
    • 제26권1호
    • /
    • pp.53-62
    • /
    • 2006
  • 본 연구는 시료 및 스펙트럼의 전처리 방법이 근적외선 분광법을 이용한 옥수수 사일리지의 화학적 조성분의 예측능력에 미치는 영향을 평가하기 위해 수행되었다. 시료의 전처리 방법은 건조하여 분쇄하는 방법(Oven Dried Grinding), 액화 질소처리 후 분쇄하는 방법(Liquid Nitrogen Grinding) 그리고 생사일리지(Intact Fresh)처리로 하였으며 4개의 스펙트럼의 수처리(1,4,4, 2,6,4, 2,10,5) 방법을 이용하여 다변량회귀분석법인 변형부분최소자승회귀법(MPLS)을 통해 검량식을 작성하였다. 시료의 전처리 방법에 의해서 유도된 검량식의 예측 능력은 섬유소 성분(NDF, ADF)과 일반 조성분(CP, Ash) 모두에서 Oven dried grinding (ODG) > Liquid nitrogen grinding (LNG)>Intact fresh (IF) 처리 순으로 우수하였다. 또한 스펙트럼의 수처리 방법에 의한 결과는 시료의 전처리 방법에 따라 그 예측 능력이 다르게 나타났다. 옥수수 사일리지의 섬유소 함량을 예측하기 위한 최적의 시료 전처리 및 스펙트럼 수처리 방법은 NDF는 ODG 처리에 2,10,5 수처리 방법 $(R^2=0.86)$, ADF는 ODG 처리에 2,10,5 수처리 방법 $(R^2v=0.93)$이 가장 우수한 전처리 방법으로 나타났다. 조단백질 함량과 조회분 함량을 측정하기 위한 최적의 시료 전처리 및 스펙트럼 수처리 방법은 조단백질은 ODG 처리에 1,4,4 수처리 방법$(R^2v,=0.91)$, 조회분은 ODG 처리에 2,10,5 수처리 방법$(R^2v=0.89)$이 가장 우수한 전처리 방법으로 판단된다. 이상의 연구 결과를 종합해보면 근적외선 분광법을 이용한 사일리지의 화학적 조성분 함량 측정은 적은 오차 범위 내에서 신속하고 정확한 분석법이 될 수 있음을 확인 할 수 있었다. 비록 원물 생시료(IF)에 대한 직접적인 측정은 다소 예측 정확성이 떨어지지만 현장 적용성과 편리성을 높이기 위해서는 생시료의 측정시 오차를 줄일 수 있는 스펙트럼의 수처리 방법이나 산란보정 방법과 같은 데이터 처리기법에 대한 더 많은 연구가 앞으로 진행되어야 한다고 생각되어진다.

64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가 (Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography)

  • 성열훈;김영옥;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제21권2호
    • /
    • pp.137-144
    • /
    • 2010
  • 64 multi-detector computed tomography (MDCT)에서 두개부의 과도한 선량이 문제가 되어 고정관류기법과 관전류 자동노출조절(automatic exposure control, AEC) 기법을 이용하여 선량 감소 정도를 비교 평가하고자 한다. 연구에 사용한 장비는 Siemens사의 SOMATOM Definition 64 multi-detector CT를 이용했으며, Whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd)의 두개부를 사용했다. 실험 protocol은 helical scan 방식을 적용하여 120 kVp, rotation time은 1 sec, slice thickness와 increment는 각각 5 mm, FOV는 250 mm, matrix size는 $512{\times}512$, collimation은 $64{\times}0.625\;mm$, pitch는 1로 조사하였다. 선량감소효과의 측정방법은 관전류를 350 mAs로 고정한 방법과 AEC 기법을 적용한 방법으로 나누어 평가하였으며, 영상품질은 CT number의 표준편차를 이용하여 영상의 잡음을 측정하였다. 이 때 두개부(craniofacial bone)는 머리덮개뼈(calvaria) 끝부분에서 눈썹활(superciliary ridge)까지를 1구역, 논썹활 아래부터 코가시점(acanthion)까지를 2구역, 그리고 코가시점 아래부터 턱(mentum)끝까지를 3구역으로 정의하여 측정하였다. 고정관류기법에서 구역별로 CTDIvol은 57.7 mGy였으며, DLP는 $640.2\;mGy{\cdot}cm$로 동일하였다. AEC 기법을 적용한 1구역은 CTDIvol: 30.7 mGy, DLP: $340.7\;mGy{\cdot}cm$, 2구역은 CTDIvol: 46.5 mGy, DLP: $515.0\;mGy{\cdot}cm$, 그리고 3구역은 CTDIvol: 30.3 mGy, DLP: $337.0\;mGy{\cdot}cm$으로 나타났다. 영상품질을 나타내는 CT number의 표준편차는 1구역에서 고정 관류기법은 2.6, AEC 기법은 3.0, 2구역에서 고정 관류기법은 3.1, AEC 기법은 3.4, 3구역에서 고정 관류기법은 2.7, AEC 기법은 3.2으로 측정되었다. 64 MDCT에서의 AEC 기법은 기존의 고정관류법에 비해 안구, 이하선 그리고 갑상선 부위에 대해 큰 선량 감소효과가 나타났으며, 두개부의 방사선량을 감소시키는데 매우 유용한 기법으로 사료된다.

사무 자동화에 따른 사무직 근로자의 건강과 연관된 자각 증상에 대한 조사연구 (An Investigation on the self-consciousness Symptoms of the Clerical Workers attendant upon Office Automation)

  • 정미화
    • 한국직업건강간호학회지
    • /
    • 제3권호
    • /
    • pp.54-70
    • /
    • 1993
  • According as the automation of clerical work(OA ; Office Automation) develops, the use of VDT(Visual or Video Display Terminal) is increasing suddenly. But, in proportion to the spread of office automation(OA tendency), the self-conciousness syptom attendant upon the work is appearing also (Kim, Jung Tae, Lee, Young Ook, 1990). The apparatuses of office enable the clerical workers to be convenient and perform mass businesses. But, they are increasing the opportunity to be exposed to VDT syndrom, techno stress, computer terminal disease, pain by muscle strain(RSI), bradycausia of noise nature, and electromagnetic waves, etc. which are referred to as the new type of occupational diseases to the workers. It is the real situation that the workers to use VDT is complaining of the physical inconvenience sense in the recent newspaper and literature, it is the point of time that the sydrome to come from VDT use and computer terminal disease, etc. must be classified into the occupational disease(Lee, Kwang Young 1990, Lee, Kyoo Hak 1990, Lee, Won Ho 1991, Lee, Si Young 1991, Lee, Joon 1991, Choi, Young Tae 1991, Heo, Seung Ho 1989). In addition, it is the real situation that the scientifitic study result about the scope that electromagnetic waves has influence on the human body has not been suggested yet, and criticism on the stable exposure permission standard about electromagnetic waves to be emitted from VDT and on the problem in the health about electromagnetic waves is continuing. (IEEE Spectrum, 1990). In addition according to the experience of nursery business of industry field, it is the real situation that the patients who consult complaining of physical and mental inconvenience sence, among the users of apparatus of office automation, are reaching 10% of the patients coming to doctor's room. Therefore, it is necessary to confirm the self-consciousness symptom that the clerical workers complain of multilaterally with the actual state examination about the use of the apparatuses of offices automaton. Thus, this study was tried as th basic data for the cosultation and education for the maintenance and furtherance of the health of workers as the nurse of industry field, by confirming the contents of self-consciousness symptom attendant upon the use of the apparatus for office outomation making the financial institution in which the spparatus for office automation in most frequently used as the subject, and by examining whether there is the difference according to the subject of study, the data were collected, by using the questionnaire method, making 200 workers who consented to the study participation as the subject, among the persons who have spent over 3 months since they used the apparatuses for office automation and didn't receive the treatment in hospital due to the clerical disease for recent 3 years. The period of data collection was from Oct. 9, 1991 to Oct. 12. As for the measurement instrument about the complaint if self-consciousness symptom attendant upon the use of apparatuses fo office automation, the question item on the complaint symptom of health problem attendant upon the treatment of VDT that Kim(1991) developed and on CMI health problem and the question items on the fatigue degree due to industry were used by previous examination to 25 persons. Collected data were analyzed with the statistical method such as percentage, arithmetic mean, Person correlation coeffient, Kai square verfication, t-test, ANOVA, etc. by using SPSS/PC+ program, and the result is as follows : 1. The self-consciousness symptom that the clerical workers complained of most frequetly appeared high in 'My eyes are tired'(99.4%), 'I feel fatigue and weariness'(99.4%), 'I feel that my head is heavy5(90.0%), 'eyesight fell'(88.8%), 'I have a stiff neck'(88.8%), 'I fell pain in the shoulder'(85.0%), 'I feel cold and painful in the eyes'(76.9%), 'I feel the dry sense of eyeball'(76.2%), 'My nerves are edgy, and I an fretful, (75.6%), 'I feel pain in the waist'(73.2%) and 'I fell pain in the back'(72.8%). It emerged that the subject use the apparatuses for office automation complained of self-consciousness symptoms related to visual symptoms and musculoskeletal symptoms. 2. As for the general feature of examination subjects, the result to see the distribution by classifying into sex, age, school career, use career of apparatuses for office automation, skillfulness degree of the use of apparatus for office automation, use hours of the apparatuses for office automation per 1 day, type of business of the apparatus for office automation, rest hours during the use of apparatus for office automation, satifaction degree of business of office automation, and work circumstance, etc. emerged as follows : As for the sex of subjects, the distribution showed that men were 58.8% and women were 41.3%, Age was average 26.9. As the distribution of school career, the distribution showed that4below the graduation of high school' was 58.8%, 'graduation from junior college-university' was 35.0%, and 'over graduate school' was 6.3%. In the question to ask the existence or non-existence of experience of health consultation in connection with the work of office automation, the response that I had the consultation exprience and I feel the necessity emergerd as 90.1% And, the case that the subject who didn't wear the glasses or lens before using the OA apparatus wear glasses or lens after using OA apparatus emerged as 28.3% of whole. As for the existence or non-existence of use career of OA apparatus, the case under 3 years was highest as 52. 7%. As for the skillfulnness degree about the use of apparatus for office automation, most of them are skillful with the fact that 'common' was 44.4%, 'skill' was 42.5%, and 'unskillful' was 13.1% As for the use average hours of the apparatus for office automation per 1 day, the distribution showed that the case under 3-6 hours was 33.1%, the case under 6-9 hours was 28.1%, the case under 3 hours was 30.6%, and the case over 9 hours was 8.1% Main OA business and the use hours for 1 day showed in the order of keeping and retrieval, business of information transmission(162min), business of information transmission(79.3 min), business of document framing(55.5 min), and business of duplication and printing(25.4min). as for the rest during the use of apparatus for affice automation, that I take rest occasion demands the major portion, but that I take after completing the work emerged as 33.8%. Though the subiness gets to be convenient by the use of the apparatus for of office automation, respondents who showed the dissatisfaction about the present OA business emergd high as 78.1%. The work circumstances of each office was good with the fact that the temperature of office was 21.8, noise was average 42.7db, and the illumination was average 364.4 lx, in the light of ANSi/HFS 100 Standard. 3. Sight syptom, musculoskeletal symptom, skin and other symptoms showed the significant difference according to the extent of skillfulness of the apparatus for office automation. All the symptoms exept skin symptom showed the difference according to the use hours of the apparatus for office automation. All the question items exept the sytoms of digestive organs and the rest hours during the apparatus for office automation showed the signicant difference. The question item which showed the signicant difference from the satisfaction degree of present OA business showed the significant difference from all the question item classified into 6 groups. But, age and school career didn't significant difference from the complaint of any self-consciousness symptoms.

    . In conclusion, the self-consciousness symptoms of the subjects to use OA apparatus appeared differently, according to sex distiction, skillfull degree of OA apparatus, use hours of OA apparatus, the rest hours during th use of OA apparatus, and the satiafaction degree of persent business. Therefore, it is necessary that the nurse in the inuctry field must recognize to receive the education about the human technological physical condition which is most proper for te use of OA apparatus and about the proper rest method until they get accustomed to the use of OA apparatus. In addition, the simple exercise relax the tention of muscle due to the repetitive simple movement, and the education for the protection of eyesight are necessary.

  • PDF
  • NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가 (Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001)

    • 김진수;이재성;이동수;정준기;이명철
      • 대한핵의학회지
      • /
      • 제38권3호
      • /
      • pp.259-267
      • /
      • 2004
    • 목적: 전신용 PET에 대한 표준 성능 평가 방법으로 NEMA NU2-2001이 확립되어 제안되었다. 따라서 새로이 설치되는 PET 스캐너뿐 아니라 기존에 사용 중인 스캐너에 대한 성능 평가가 이 표준 방법에 따라서 새로이 이루어 져야 한다. 이 연구에서는 NEMA NU2-2001 방법을 이용하여 CTI ECAT EXACT 47 PET 스캐너의 공간해상도, 민감도, 산란분획, NECR 등을 측정하였다. 대상 및 방법: 공간해상도를 평가하기 위하여 축 방향 시야의 정 가운데와 축 방향 시야 길이의 1/4을 벗어난 횡단면에 F-10을 채운 유리관(내경 1.1 mm)을 횡단면의 중심에서 1, 10 cm 떨어진 지점에 축 방향과 평행하게 위치시킨 후 PET 영상을 얻었다. 민감도를 측정하기 위하여 폴리에틸렌 및 알루미늄 관에 F-18을 채운 후 불응시간 손실이 1%를 넘지 않는 것을 확인한 후 영상을 획득하였다. 산란분획 및 최적 영상 획득 조건을 얻기 위하여 NECR을 NEMA 산란 팬텀을 이용하여 측정하였다. 결과: FBP재구성 방법(화소 크기: $0.515{\times}0.515mm^2$)으로 영상을 재 구성했을 때 스캐너의 중심에서 1cm 벗어난 지점에서 축방향, 횡축방향 공간 분해능은 0.62, 0.66 cm (FBP, 2D와 3D), 0.67, 0.69 cm (FBP, 2D와 3D)이었고 중심에서 10 cm 벗어난 지점에서 축방향, 횡축반경방향, 횡축접선방향 공간 분해능은 0.72, 0.68 mm (FBP, 2D와 3D), 0.63, 0.66 mm (FBP, 2D와 3D), 0.72, 0.66 mm (FBP, 2D와 3D)이었다. 민감도는 스캐너의 횡축방향 708.6 (2D), 2931.3 (3D) counts/sec/MBq, 횡축방향 중심에서 10cm 벗어난 지점에서 728.7 (2D), 3398.2 (3D) counts/sec/MBq 이었다. 산란 분획은 0.19 (2D), 0.49 (3D)이었고 최고 참 계수율과 NECR은 2차원 영상 획득 모드에서 40.1 kBq/mL 일 때 64.0 kcps, 40.1 kBq/mL 일 때 49.6 kcps, 3차원 영상 획득 모드에서 4.76 kBq/mL 일 때 53.7 kcps, 4.47 kBq/mL 일 때 26.4 kcps이었다. 결론: 이 실험에서 NEMA NU2-2001로 측정한 PET스캐너의 물리적 특성은 PET스캐너에 대한 객관적 평가 및 최적화 된 영상 획득과 분석에 유용할 것이다.

    부채살 SPECT 데이터를 위한 정칙화된 기댓값 최대화 재구성기법 개발 (Development of Regularized Expectation Maximization Algorithms for Fan-Beam SPECT Data)

    • 김수미;이재성;이수진;김경민;이동수
      • 대한핵의학회지
      • /
      • 제39권6호
      • /
      • pp.464-472
      • /
      • 2005
    • 목적: 부채살 단일광자단층촬영(SPECT)은 공간분해능과 민감도를 개선하는 것으로 알려져 있다. 보다 정확한 영상을 얻고 인체에 대한 SPECT의 영상화 과정을 정확하게 묘사하기 위하여 평행 데이터로 재배열하는 과정 없이 직접 부채살 데이터를 이용하여 재구성하는 알고리즘이 필요하다. 본 연구는 다양한 부채살 재구성 알고리즘을 구현하였고 각 방법의 성능을 비교하였다. 대상 및 방법: 선추적법을 적용하여 부채살 투사기와 이로부터 얻은 데이터를 직접 재구성할 수 있는 FBP, EM, OS-EM과 MAP-EM OSL 알고리즘을 구현하였다. OSL 알고리즘의 경우에는 membrane과 thin plate prior를 사용하였다. 직접 부채살 데이터를 재구성하는 방법의 성능을 평가하기 위해 양방향 최근접 이웃, 양방향 1차와 양방향 3차 보간법을 사용하여 재배열된 평행 데이터를 얻었고 이 데이터를 기존의 평행 데이터에 대한 EM 알고리즘을 사용하여 재구성하였다. Hoffman 두뇌와 Shepp/Logan 팬텀으로부터 얻은 잡음 없는 데이터와 잡음 있는 데이터는 각 방법으로 재구성하였으며 퍼센트 오차를 계산하여 각 재구성된 영상을 비교하였다. 결과: Thin-plate 사전 분포함수를 사용한 OSL 방법이 가장 낮은 오차를 가지며 잡음으로 인한 결과 영상의 불안정성을 효과적으로 제어함을 확인할 수 있었다. 부채살 데이터를 평행 데이터로 재배열시 양방향 1차 보간법이 정확성과 계산 시간 측면에서 가장 효율적인 방법임을 확인하였다. 재배열된 평행 데이터의 EM결과에 비해 직접 부채살 데이터를 재구성하여 얻은 결과영상이 더 정확하게 재구성되었다. 결론: 본 연구에서는 평행 데이터로 재배열한 경우에 비하여 보다 정확한 영상을 재구성하는 직접 부채살 재구성 알고리즘을 구현하였으며 이는 정량적으로 월등히 개선된 결과를 제공함을 확인하였다.

    정상 성인의 직교유도체제와 피라미드유도체제에 의한 신호 가산 평균심전도의 비교 (Comparision of Signal-Averaged Electrocardiography (SAECG) Determined by Flank Lead System (FLS) and Pyramidal Lead System (PLS) in Healthy Young Adults)

    • 장병익;강승호;김형일;신동구;김영조;심봉섭;이현우
      • Journal of Yeungnam Medical Science
      • /
      • 제10권1호
      • /
      • pp.179-189
      • /
      • 1993
    • 고전적인 직교 유도체제를 이용하여 고해상신호가산 심전도의 95% 신뢰구간을 구하고 His 분절 활성을 잘 기록할 수 있는 피라미드 유도체제와 비교함으로써 피라미드 유도체제가 미연전이를 발견할 수 있는데 사용될 수 있는지를 알아 보고자 영남대학 의과대학에 재학중인 젊은 정상 지원자 31명을 대상으로 고해상 신호가산 평균심전도를 측정하였다. 젊은 성인에 있어 직교 유도체제를 이용한 고해상 신호가산 심정도의 여과된 총 QRS 지속시간과 고빈도 저전위 신호 지속시간은 각각 25-250 Hz 주파수 여파에서는 129.6과 22.5 msec, 40-250 Hz 주파수 여과에서는 114.4와 31.9 msec, 80-250 Hz 주파수 여과에서는 110.4와 38.4 msec 이상을 비정상 범위로 잡을수 있고, QRS 말기 40 msec의 평균전위와 RMS 전위는 각각 25-250 Hz 주파수 여과에서는 49와 68.6 uV, 40-250 Hz 주파수 여과에서는 27.9와 58.8 uV. 80-250 Hz 주파수 여과에서는 10.6와 16.3 uV 이하를 비정상 범위로 잡을 수 있었다. 피라미드 유도체제도 미연전위를 기록하는데 유용하리라 사료되지만 40-250 Hz 주파수 여과에서 고빈도 저전위 신호 지속시간과 RMS 전위는 직교 유도체제와 달라 이에 대한 더 많은 연구가 필요하리라 사료된다.

    • PDF