• Title/Summary/Keyword: Noise Standard

Search Result 1,475, Processing Time 0.027 seconds

Estimation of GPS Holdover Performance with Ladder Algorithm Used for an UFIR Filter (UFIR 필터 Ladder 알고리즘 이용 GPS Holdover 성능 추정)

  • Lee, Young-kyu;Yang, Sung-hoon;Lee, Chang-bok;Heo, Moon-beom
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.669-676
    • /
    • 2015
  • In this paper, we described the simulation results of the phase offset performance of a clock in holdover mode which was normally operated in GPS Disciplined Oscillator (GPSDO). In the TIE model, we included the time error term caused by environmental temperature variation because one of the most important parameters of clock phase error is the frequency offset and drift caused by the variation of temperature. For the simulation, we employed Maximum Time Interval Error (MTIE) for the performance evaluation when the frequency offset and drift are estimated by using an Unbiased Finite Impulse Response (UFIR) filter with ladder algorithm. We assumed that the noise in the GPS measurement is white Gaussian with zero mean and 1 ns standard deviation, and temperature linearly varies with a slope of $1{^{\circ}C}$ per hour. From the simulation results, the followings were observed. First, with the estimation error of temperature of less than 3 % and the temperature compensation period of less than 900 seconds, the requirement of CDMA2000 phase synchronization under 10 us could be achieved for more than 40,000 seconds holdover time if we employ an OCXO (Oven Controlled Crystal Oscillator) clock. Second, in order to achieve the requirement of LTE-TDD under 1.5 us for more than 10,000 seconds holdover time, below 3 % estimation error and 500 seconds should be retained if a Rubidium clock is adopted.

Liquefaction Prevention and Damage Reduction Effect of Reinforcement by Sheet Pile Using 1-G Shaking Table Test (1-G 진동대 실험을 이용한 시트파일 보강재의 액상화 및 피해 방지 효과)

  • Sim, Sung Hun;Yoon, Jong Chan;Son, Su Won;Kim, Jin Man
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.211-217
    • /
    • 2020
  • Earthquake preparedness has become more important with recent increase in the number of earthquakes in Korea, but many existing structures are not prepared for earthquakes. There are various types of liquefaction prevention method that can be applied, such as compaction, replacement, dewatering, and inhibition of shear strain. However, most of the liquefaction prevention methods are applied before construction, and it is important to find optimal methods that can be applied to existing structures and that have few effects on the environment, such as noise, vibration, and changes in underground water level. The purpose of this study is to estimate the correlation between the displacement of a structure and variations of pore water pressure on the ground in accordance with the depth of the sheet file when liquidation occurs. To achieve this, a shaking table test was performed for Joo-Mun-Jin standard sand and an earth pressure, accelerometer, pore water pressure transducer, and LVDT were installed in both the non-liquefiable layer and the liquefiable layer to measure the subsidence and excess pore water pressure in accordance with the time of each embedded depth. Then the results were analyzed. A comparison of the pore water pressure in accordance with Hsp/Hsl was shown to prevent lateral water flow at 1, 0.85 and confirmed that the pore water pressure increased. In addition, the relationship between Hsp/Hsl and subsidence was expressed as a trend line to calculate the expected settlement rate formula for the embedded depth ratio.

Error Probability Analysis for the Initial Acquisition Using Sum Differential Correlation Methods (합산 차등 상관 방식을 활용하는 초기 동기 획득 시의 오율 성능 분석)

  • Kim, Sang-Tae;Kim, Jae-Won;Chang, Dae-Ig;Kim, Pan-Soo;Sung, Won-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12C
    • /
    • pp.983-990
    • /
    • 2008
  • In communication systems, initial acquisition is required for the reliable transmission performance, and the analysis of the acquisition performance over various communication environments including different signal-to-noise ratios plays an important role in communication system design. Usage of differential correlation methods in initial synchronization procedure is desired when frequency offsets exist, and additional performance improvement can be achieved through proper modifications of conventional correlation schemes. In this paper, we derive the error probability of the initial acquisition and express it in terms of the Marcum Q-function, via statistical modeling of the differential correlator output. The result is generalized to the error probabilities of the extended differential correlation methods using the complex- and magnitude-sum of the correlator outputs. The derived probabilities can be applied for the acquisition performance verification of various communication systems including the DVB-S2 standard.

Development of Wireless Respiratory Air Flow and Urinary Flow Measurement System for Home Healthcare (가정용 무선 호흡기류 및 요속신호 계측 시스템 개발)

  • Cha, Eun-Jong;Lee, In-Kwang;Lee, You-Mi;Han, Soon-Wha;Han, Jeong-Su;Suh, Jae-Won;Park, Chan-Sik;Kim, Kyung-Ah
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1350-1357
    • /
    • 2012
  • Medical system for personal health management recently changes its paradigm from hospital service to self home care based on ubiquitous technology for healthcare anywhere at any time. The present study developed a wireless bio-signal measurement system for patients to self manage pulmonary disease and benign prostate hyperplasia(BPH), both of which are chronic diseases with increasing frequency in modern society. Velocity-type respiratory air flow transducer adapted to develop respiratory module for pulmonary disease management was simplified in structure to measure uni-directional flow since most important diagnostic parameters are evaluated on the expiratory flow signal only. Standard weight measurement technique was introduced to obtain urinary flow signal for BPH management. Three load cell signals were acquired for averaging to minimize noise, followed by accuracy evaluation. Transmission and receiver modules were also developed with user program for wireless communication. Averaged relative errors were 2.05 and 1.02% for respiratory volume and maximal flow rate, respectively, and the relative error was 2.17% for urinary volume, demonstrating that both modules enabled very accurate measurements. Wireless communication distance was verified within 15m, long enough for home care application. The present system allows the user to select a necessary measurement module on a particular health demand and to immediately provide the self-test results, thus better quality health care would be possible.

Design of a 5.2GHz/2.4GHz Dual band CMOS Frequency Synthesizer for WLAN (WLAN을 위한 5.2GHz/2.4GHz 이중대역 주차수 합성기의 설계)

  • Kim, Kwang-Il;Lee, Sang-Cheol;Yoon, Kwang-Sub;Kim, Seok-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.1A
    • /
    • pp.134-141
    • /
    • 2007
  • This paper presents a frequency synthesizer(FS) for 5.2GHz/2.4GHz dual band wireless applications which is designed in a standard $0.18{\mu}m$ CMOS1P6M process. The 2.4GHz frequency is obtained from the 5.2GHz output frequency of Voltage Controlled Oscillator (VCO) by using the Switched Capacitor (SC) and the divider-by-2. Power dissipations of the proposed FS and VCO are 25mW and 3.6mW, respectively. The tuning range of VCO is 700MHz and the locking time is $4{\mu}s$. The simulated phase noise of PLL is -101.36dBc/Hz at 200kHz offset frequency from 5.0GHz with SCA circuit on.

New Algorithm for Arbitrary-ratio Image Resizing in DCT Domain (DCT 영역에서 영상의 임의 비율 크기 변환을 위한 새로운 알고리즘)

  • Kim, Yong-Jae;Lee, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2C
    • /
    • pp.113-123
    • /
    • 2007
  • In Ubiquitous communication environment, various conversions of images are essential, and most digital images are compressed by standard methods such as the Joint Photographic Expert Group (JPEG) and Motion Picture Expert Group (MPEG) which are based on the discrete cosine transform (DCT). In this paper, various image resizing algorithms in the DCT domain are analyzed, and a new image resizing algorithm, which shows superior performance compared with the conventional methods, is proposed. For arbitrary-ratio image resizing in the DCT domain, several blocks of $8{\times}8$ DCT coefficients are converted into one block using the conversion formula in the proposed algorithm, and the size of the inverse discrete cosine transform (IDCT) is decided optimally. The performance is analyzed by comparing the peak signal to noise ratio (PSNR) between original images and converted images. The performance of the proposed algorithm is better than that of the conventional algorithm, since the correlation of pixels in images is utilized more efficiently.

Design and Fabrication of Broad-Band EMC Filter for Power Line (전원선에서의 광대역 EMC 필터의 설계 및 제작)

  • Kim, Dong-Il;Ku, Dong-Woo;Yang, Eun-Jung;Kim, Do-Yearn;Yea, Byeong-Dok
    • Journal of Navigation and Port Research
    • /
    • v.26 no.5
    • /
    • pp.525-528
    • /
    • 2002
  • The proposed EMC filter composed with feed-through capacitors and ferrite beads of high permeability was prepared which satisfy the EMC standard for a wide-band noise signal in the frequence of 10 MHz to 1.5 GHz in power supply line. The optimum structure of ferrite bead was found by calculating the load effect of ferrite beads. As a result, the filter showed excellent differential- and common-mode noises filtering characteristics above 30dB in the frequency band from 10 MHz to 1.5 GHz. The immunity characteristics are improved more than 10 to 30 dB over the frequency band from DC to 1.8GHz.

An Analysis of the Spatial Range of Environmental Impact Assessment(EIA) - Focusing on Landscape Ecological Aspects - (환경영향평가대상의 공간적 평가범위 설정에 관한 연구 - 경관생태학적 측면에서 -)

  • Oh, Kyushik;Kim, Hee-Ju;Lee, Dong-Kun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.3
    • /
    • pp.130-141
    • /
    • 2009
  • The spatial range of EIA is mainly related to landscape ecological factors such as topography, geology, animals, and plants. Problems were detected involved land, soil, noise, oscillation, the atmosphere, animals, and plants in the natural-environment. First of all, the current EIA lacks explicit spatial ranges and sections in terms of scientific exactitude and objectivity for assessment. Secondly, there are overlapping influence-area problems resulting in cumulative impacts of unit developments that accumulate. Finally, some developments have no regard for ecological and conservational value in relation to determining which effect ecological stability, and which should be regarded as Regional Ecological Resources. Therefore, this study suggests that EIA should be improved in the following manner. First, the standard classification of landscape unit for analysis should be established 10 regulate each spatial range on a wide-landscape scale. Secondly, the impacts resulting from the interaction of overlapping influence-area developments between individual development should be assessed. Third, Minimization of the of the environmental effects is needed by applying the cumulative effects to the influence-area where developments occur in the same time or in a sequence. Fourth, individual characteristics of landscape elements such as roads, rivers, and green networks need to be considered separately in the analysis. Finally, regional ecological habitats should be included in the analysis in order to achieve stable ecosystems.

Development of AAS and Determination of metals in airborne particles (원자흡수분광광도계의 제작 및 분진 중 금속성분 분석 비교)

  • Choi, Bae-Jin;Bang, Myung-Sik;Yeo, In-Hyeong
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.226-231
    • /
    • 2003
  • We analyzed the concentrations of heavy metals associated airbone particles by using AAS made by both a domestic manufacturer and one of the foreign manufacturer. One model developed by a domestic manufacture showed excellent results in the selected wavelength with an excellent performance of a monochromator. It abandons a big drop except a fine drop to improve reproduction in atomizer, so that no remains should leave. Using the low pass filter we were able to reduce a noise of detection signal. The performance of our equipment was found to be highly compatible with that of a foreign company as we achieved the detection limit of about $0.015{\mu}g/L$ using a standard solution of Au. The PM samples had been collected from by main observation points in 7 areas of Seoul city from 2001 to the spring in 2002. with these PM sample we analyzed the concentrations of Pb, Cu, Mn, Cd, Ni, Fe, Cr, Co, Mg and Al.

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.