• Title/Summary/Keyword: Noise Sources

Search Result 1,196, Processing Time 0.023 seconds

Study on the Sound Radiaton Characteristics of Trains by Sound Intensity Method (음향 인텐시티법을 이용한 주행열차의 음향방사특성의 검토)

  • 주진수;김재철
    • Journal of KSNVE
    • /
    • v.8 no.4
    • /
    • pp.603-608
    • /
    • 1998
  • In order to obtain basic data for the prediction of railway noise propagation, the noise radiation characteristics (source position, radiation directivity, etc) of trains were measured by using the sound intensity method. The measurements were performed at a side of railway by setting an intensity-probe array. As the measurement results, it was found that rolling noise due to interaction between wheel and rail and motor noise radiation from the lower part of train are dominant. The location of main sound sources can be described as being at the height of 0.1m in the center line of track, and the radiation directivity in the cross section of actually running trains are presented as a dipole source.

  • PDF

Computation of serrated trailing edge flow and noise using a hybrid zonal RANS-LES

  • Kim, Tae-Hyung;Lee, Seung-Hoon;Lee, Soo-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.414-419
    • /
    • 2012
  • The evaluation of a zonal RANS-LES approach is documented for the prediction of broadband noise generated by the flow past unmodified and serrated airfoil trailing edges at a high Reynolds number. A multi-domain decomposition is considered, where the acoustic sources are resolved with a LES sub-domain embedded in the RANS domain. A stochastic vortex method is used to generate synthetic turbulent perturbations at the RANS-LES interface. The simulations are performed with a general-purpose unstructured control-volume code FLUENT. The far-field noise is calculated using the aeroacoustic analogy of Ffowcs Williams-Hawkings. The results of the simulation are validated through the full-scaled wind turbine acoustic measurements. It is found that the present approach is adequate for predicting noise radiation of serrated trailing edge flow for low noise rotor system.

  • PDF

Computation of Serrated Trailing Edge Flow and Noise Using a Hybrid Zonal RANS-LES (혼합 영역 RANS-LES를 이용한 톱니 뒷전 유동 및 소음장의 계산)

  • Kim, Tae-Hyung;Lee, Seung-Hoon;Lee, Soo-Gab
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.5
    • /
    • pp.444-450
    • /
    • 2012
  • The evaluation of a zonal RANS-LES approach is documented for the prediction of broadband noise generated by the flow past unmodified and serrated airfoil trailing edges at a high Reynolds number. A multi-domain decomposition is considered, where the acoustic sources are resolved with a LES sub-domain embedded in the RANS domain. A stochastic vortex method is used to generate synthetic turbulent perturbations at the RANS-LES interface. The simulations are performed with a general-purpose unstructured control-volume code FLUENT. The far-field noise is calculated using the aeroacoustic analogy of Ffowcs Williams-Hawkings. The results of the simulation are validated through the full-scaled wind turbine acoustic measurements. It is found that the present approach is adequate for predicting noise radiation of serrated trailing edge flow for low noise rotor system.

Analysis of Acoustic Noise Characteristics of Jindo-Cheju HVDC (진도-제주 HVDC 변환설비 소음특성 분석)

  • Kim, Jae-Han;Kim, Chan-Ki;Lee, Seong-Doo;Kim, Jin-Young
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.574-576
    • /
    • 2010
  • HVDC converter station consists of a number of noise sources such as converter transformer, ac filter, cooling system and so on. In this paper, we analyzed the simulation results of the outdoor acoustic noise characteristics for HVDC converter station. It shows that maximum noise level in boundary of HVDC converter station exceeds regulation value. The main factors in generating maximum noise level are ac filter and converter transformer. Then we applied some soundproof countermeasure in HVDC converter station. Shielding wall is enough to reduce transformer noise level but not enough to reduce ac filter noise level. In case of ac filter, soundproof building is effective in satisfying noise level regulation in boundary of HVDC converter station. In addition, we also studied effects of season, soundproof woods, ground.

  • PDF

Noise reduction of a high precision gearbox based on experimental study (실험적 방법을 통한 고정밀 감속기의 소음 저감)

  • Lee, Kyu-Ho;Kim, Woo-Hyung;Chung, Jin-Tai
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.266-270
    • /
    • 2006
  • Noise reduction the noise of a high precision multi-stage gearbox applied at the industrial robot is investigated by experiment such as the modal test and the signal analysis. The signal analysis performed with the waterfall plot representing the power spectrum as a function of the rotating speed. An eccentric load is installed at the gearbox in order to organize similar condition used in the industrial robot. Exciting sources are found out by the waterfall plot, and then the main factor to make the noise is distinguish. For the low-noise gearbox, the gear design parameter is modified and this gearbox is experimented in the same procedure. The results of the test show the noise level of gearbox reduced.

  • PDF

Analysis of Physical Parameters for the Evaluation of HVAC Diffuser Noise (공기조화 취출구 소음 평가를 위한 물리지수 분석)

  • Park, Hyeon-Ku;Kim, Hang;Go, Seong-Seok;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.402-405
    • /
    • 2006
  • The diffuser noise of HVAC(heating ventilating and air-conditioning) uses dB(A) or NC as a indoor noise criteria that ASHRAE represents, and there is no specific guide line for application. According to the previous study, there are some problems like that even though the sound level of sound source is same, the NC shows different values, which makes the noise rating confused. This problem is caused by the frequency characteristics of sound source and its sound level. Therefore, appropriate evaluation method should be considered based on the subjective responses. This study aims to analyze the physical parameters appropriate for the evaluation of HVAC diffuser noise. To achieve this, recording of sound sources, calculation of physical parameters and psycho-acoustic experiment were carried out and the results were derived from the correlation analysis between physical parameters and subjective evaluatio

  • PDF

Prediction of the Noise Level inside Metro Electric Cars (통근형 전동차의 객실 내 소음수준예측)

  • 서승일;최문길;김국현
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.185-191
    • /
    • 1999
  • This paper deals with a method to predict the noise level inside metro electric cars running a single-line tunnel at the speed of 80km per hour using ray tracing method, a kind of ray acoustics generally used for a high-frequency and air-born noise analysis. The interior of the car including a under-frame, seats, side doors, end doors, door-pockets, side panels, end panel, a roof panel and so on is modeled. And in order to describe the noise power coming inside, artificial noise sources are designated using sound transmission loss data of each section measured from simple tests and external noise level. The noise level inside the car is calculated and its properties are investigated. The results satisfy the criteria on noise level inside the car.

  • PDF

The Noise Analysis of Ship HVAC System Based on GUI Modeling (GUI Modeling을 기반으로한 선박의 HVAC System 소음 해석)

  • 이철원;김노성;최수현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1300-1305
    • /
    • 2001
  • One of the main noise sources in cabin onboard ships is HVAC system. Up to now, the HVAC system designer manually calculates the HVAC system noise, or uses the program that is generally based on text user interface. In such a case, it is difficult to use the program and also to obtain the flow induced noise. In this study, the HVAC noise analysis program has been developed, which is based on GUI user interface that include 3.D modelling and model modification modules. For calculation of the insertion loss of HVAC system elements, NEBB experimental data and plane wave theory are used. And in order to obtain the flow rate information in each HVAC elements which is used to calculate the flow induced noise calculation, Global Converging Newton-Rapson Method is used.

  • PDF

Road Traffic Noise Status and Prediction (도로교통소음(道路交通騷音) 현황과 예측)

  • Kang, Dae-Joon;Kim, J.M.;Park, J.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.512-517
    • /
    • 2000
  • The road traffic noise becomes aggravated due to the rapid increase of vehicles. It has a great effect on the dwelling environment. Therefore we investigate the characteristics and sources of the road traffic noise through grasping the status of the road traffic noise. This report is concerned with the description of the various factors affecting the generation and propagation of outdoor traffic noise. It is particularly concerned with the mathematical interpretation of these processes and the resulting development of prediction techniques which are now broadly used for both the environment impact assessment of road traffic noise and the planning and design of roads and adjoining land use.

  • PDF

Identifications and Reductions of Aerodynamic Noise Sources in High Speed Rotating CD-Rom Drive (고속으로 회전하는 CD-Rom 드라이브의 공력 소음원 규명 및 소음 저감)

  • Heo, Dae-Nyoung;Kim, Yong-Seok;Han, Seung-Jin;Kim, Young-Chan;Lee, Duck-Joo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.771-776
    • /
    • 2000
  • Major noise source in high speed rotating CD-Rom drives arises due to the high-speed airflow produced from the upper and lower surfaces on the rotating disk. The present paper deals with the experimental approach how to identify the noise source based on the fundamental principles of aeroacoustics and to propose a reduction method of the noise source. Experimental studies were carried out in the anechoic wind tunnel with various design modifications, such as tray geometry and window size, to identify and reduce the major aerodynamic noise source and significant reductions of the noise source were obtained.

  • PDF