• 제목/요약/키워드: Noise Reduction Technology

검색결과 609건 처리시간 0.03초

Image Noise Reduction Using Structural Mode Shaping for Scanning Electron Microscopy

  • Hamochi, Mitsuru;Wakui, Shinji
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권2호
    • /
    • pp.28-33
    • /
    • 2008
  • In a scanning electron microscope (SEM), outside acoustic noise causes image noise that distorts observations of the specimen being examined. A SEM that is less sensitive to acoustic noise is highly desirable. This paper investigates the image noise problem by addressing the mode shapes of the base plate and the transmission path of the acoustic noise and vibration. By arranging the position of the rib, a new SEM base plate was developed that had twisting as the 1st and 2nd modes. In those two twisting modes, vibration nodes existed near the center of the base plate where the specimen chamber is placed. Less vibration was transmitted to the chamber and to the specimen by the twisting modes compared to bending ones, which are the 2nd and 3rd modes for a rectangular plain base plate. An SEM with the developed base plate installed exhibited a significant reduction of image noise when exposed to acoustic noises below 250 Hz.

수동/능동적 방법을 혼용한 압전지능패널의 광대역 전달 소음저감성능 (Transmitted Noise Reduction of Piezoelectric Smart Panels using Passive/Active Method in Wide Range frequency)

  • 이중근;박우철
    • 한국산학기술학회논문지
    • /
    • 제2권2호
    • /
    • pp.73-79
    • /
    • 2001
  • 압전재료를 이용한 지능패널의 전달음 저감성능을 실험적으로 연구하였다. 제안된 압전지능패널은 압전 감지기와 작동기가 부착되어 있는 주구조물에 흡음재가 한 쪽면에 부착된 구조이다. 이는 저주파에서 능동적 방법과 고주파에서 수동적방법을 혼용한 개념이다. 이 개념을 증명하기 위하여 음향실험을 수행하였다. 음향실험을 위하여 음향터널을 설계, 제작하여 음향특성을 실험하였다. 음향 특성실험을 통하여 800 Hz가지 평면파특성을 나타내었다. 단일패널에 흡음재를 부착한 지능패널은 첫번째 공진주파수영역을 제외한 중주파수영역에서 뚜렸한 소음저감성능을 나타내었다. 첫번째 공진주파수에 대하여 반전회로를 이용한 능동제어를 수행하여 약 10 dB소음저감을 이루었다. 또한, 공기층을 갖는 이중지능패널에 대한 실험을 통하여 공진주파수에서 뿐만 아니라 넓은 영역에서 좋은 소음저감성능을 보였다. 수동적 방법과 능동적 방법을 혼용한 압전지능패널은 넓은 주파수 영역에서의 소온저감대책으로 유망한 기술이다.

  • PDF

시스템분배기 소음방지 및 성능개선방안 연구 (A Study on the Noise Reduction and Performance Improvement of the Hot Water Distributing System)

  • 김용기;이태원;한태수;유선학
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1055-1060
    • /
    • 2009
  • Noise is one of the major environmental problems in human life. But hot water distributers with the flow rate control valve bring about often noise according to the heating control condition in residential buildings. The sound power level increased as the flow rate and pressure difference increased. And thus, experimental analyses for the flow rate control and the pressure difference control were carried out in this study to reduce the noise emitted from the flow rate control valve. As the results, the flow rate control method using a SMA(Shape Memory Alloy)-valve and the flow rate control system using a pressure difference sensor can be expected to control noise in the region of below 50 dB of sound power level.

  • PDF

건설공사장 이동식 방음시설물의 음향특성 (Site Mitigation Plan for Noise Sources from Construction Sites by Developing Movable Noise Barriers)

  • 이성찬;정진연;임정빈
    • 한국소음진동공학회논문집
    • /
    • 제25권1호
    • /
    • pp.58-64
    • /
    • 2015
  • There are a lot of different types of noise from construction site and it depends on construction stage, equipment type and number of operating equipments. The problem is that the almost noise from construction site is high level and some kinds of noise levels are over 100 dB. In addition, if construction site is located in downtown, there are a few options to reduce noise level. Therefore several site mitigation plans were developed to reduce different types of construction noises such as breaker work, gang form and asphalt saw. They were applied in site and evaluated noise reduction performance. The test result of site insertion loss was between 4~8 dB depends on the equipment and type of work.

Enhancing Medical Images by New Fuzzy Membership Function Median Based Noise Detection and Filtering Technique

  • Elaiyaraja, G.;Kumaratharan, N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2197-2204
    • /
    • 2015
  • In recent years, medical image diagnosis has growing significant momentous in the medicinal field. Brain and lung image of patient are distorted with salt and pepper noise is caused by moving the head and chest during scanning process of patients. Reconstruction of these images is a most significant field of diagnostic evaluation and is produced clearly through techniques such as linear or non-linear filtering. However, restored images are produced with smaller amount of noise reduction in the presence of huge magnitude of salt and pepper noises. To eliminate the high density of salt and pepper noises from the reproduction of images, a new efficient fuzzy based median filtering algorithm with a moderate elapsed time is proposed in this paper. Reproduction image results show enhanced performance for the proposed algorithm over other available noise reduction filtering techniques in terms of peak signal -to -noise ratio (PSNR), mean square error (MSE), root mean square error (RMSE), mean absolute error (MAE), image enhancement factor (IMF) and structural similarity (SSIM) value when tested on different medical images like magnetic resonance imaging (MRI) and computer tomography (CT) scan brain image and CT scan lung image. The introduced algorithm is switching filter that recognize the noise pixels and then corrects them by using median filter with fuzzy two-sided π- membership function for extracting the local information.

FEASIBILITY STUDY OF SOUND POWER BASED ACTIVE NOISE CONTROL STRATEGIES FOR GLOBAL NOISE REDUCTION

  • Kang, Seong-Woo;Kim, Yang-Hann
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.785-790
    • /
    • 1994
  • The active noise control which regards the acoustic power as a target function to be minimized, is analyzed to test its feasibility of which simplifies the measurement system compared with the global acoustic energy based active noise control system. In fact, it is found that the acoustic power based active noise control strategy is equally likely as good as the global acoustic energy based active noise control method if the acoustic field of interest is diffusive or very low model density one. In the intermediate model density field, we also demonstrate that the power based control gives the similar results as the energy based control in terms of global sound energy reduction for the lightly damped enclosure which might be most important system in practical application. From all the theoretical and power based control strategy is dependent on the characteristics of the acoustic field to be controlled; i.e., the model density distribution, the degree of reverberation, and on the strength of modal interaction of the control source with the primary source; i.e., the location of control source.

  • PDF

EMI Prediction and Reduction of Zero-Crossing Noise in Totem-Pole Bridgeless PFC Converters

  • Zhang, Baihua;Lin, Qiang;Imaoka, Jun;Shoyama, Masahito;Tomioka, Satoshi;Takegami, Eiji
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.278-287
    • /
    • 2019
  • In this study, a zero-crossing spike current issue in a totem-pole bridgeless power factor correction (PFC) converter is comprehensively investigated for the first time. Spike current occurs when input voltage crosses zero, becomes a noise source, and causes severe common mode emission issues. A generation mechanism for electromagnetic interference (EMI) is presented to investigate the EMI problem caused by zero-crossing issue, and a noise spectrum due to this issue is predicted by a theoretical analysis based on the Fourier coefficient of an approximate spike current waveform. Furthermore, a noise reduction method is proposed and then improved to reduce the spike current. Experimental measurements are implemented on a GaN-based totem-pole bridgeless PFC converter, and the spike current can be effectively suppressed through the proposed method. Furthermore, the noise spectrums measured without and with the reduced zero-crossing spike current are compared. Experimental results validate the analysis of the noise spectrum caused by the zero-crossing spike current issue.

동력분산형 고속철도의 실내외 소음저감기술 연구 (Study on the Noise Reduction Techniques of the High-Speed EMU)

  • 홍윤혁;김정태;김정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1148-1153
    • /
    • 2008
  • Noise pollution from a high speed train has been a serious social issue nowadays. Especially when a train speed exceeds 350 km/hr, an aerodynamic noise level has been known to be increased drastically. In this paper, explained were the studies on the noise reduction and engineering approaches to estimate and analyze influences of noise. Based on this study, it is estimated to apply results to development of trains and expected to accomplish futuristic technology by devising noise prediction of high speed EMU and measures to reduce noise on a design phase.

  • PDF

PET/MR 영상에서의 팬텀을 활용한 노이즈 감소를 위한 변형된 중간값 위너필터의 적용 효율성 연구 (Efficiency of Median Modified Wiener Filter Algorithm for Noise Reduction in PET/MR Images: A Phantom Study)

  • 조영현;이세정;이영진;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.225-229
    • /
    • 2021
  • The digital image such as medical X-ray and nuclear medicine field mainly contains noise distribution. The noise degree in image degrades image quality. That is why, the noise reduction algorithm is efficient for medical image field. In this study, we confirmed effectiveness of application for median modified Wiener filter (MMWF) algorithm for noise reduction in PET/MR image compared with median filter image, which is used as conventional noise redcution algorithm. The Jaszczak PET phantom was used by using 18F solution and filled with NaCl+NiSO4 fluids. In addition, the radioactivity ratio between background and six spheres in the phantom is maintained to 1:8. In order to mimic noise distribution in the image, we applied Gaussian noise using MATLAB software. To evlauate image quality, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used. According to the results, compared with noise image and images with MMWF algorithm, the image with MMWF algorithm is increased approximately 33.2% for CNR result, decreased approximately 79.3% for COV result. In conclusion, we proved usefulness of MMWF algorithm in the PET/MR images.

Novel Phase Noise Reduction Method for CPW-Based Microwave Oscillator Circuit Utilizing a Compact Planar Helical Resonator

  • Hwang, Cheol-Gyu;Myung, Noh-Hoon
    • ETRI Journal
    • /
    • 제28권4호
    • /
    • pp.529-532
    • /
    • 2006
  • This letter describes a compact printed helical resonator and its application to a microwave oscillator circuit implemented in coplanar waveguide (CPW) technology. The high quality (Q)-factor and spurious-free characteristic of the resonator contribute to the phase noise reduction and the harmonic suppression of the resulting oscillator circuit, respectively. The designed resonator showed a loaded Q-factor of 180 in a chip area of only 40% of the corresponding miniaturized hairpin resonator without any spurious resonances. The fully planar oscillator incorporated with this resonator showed an additional phase noise reduction of 10.5 dB at a 1 MHz offset and a second harmonic suppression enhancement of 6 dB when compared to those of a conventional CPW oscillator without the planar helical resonator structure.

  • PDF