• Title/Summary/Keyword: Noise Reducing Effect

Search Result 202, Processing Time 0.047 seconds

Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(3) - Suggestion of Test and Estimation Method - (방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(3) - 시험 및 평가방법의 제안 -)

  • Kim, Chul-Hwan;Chan, Tae-Sun;Kang, Hee-Man;Jeon, Ki-Seong;Kim, Dong-Joon;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.496-499
    • /
    • 2008
  • The noise reducing devices installed on the noise barrier have been developed in many shapes and ways to reduce noise around road traffic areas. In this study, test and estimation method for the noise reducing device witch installed on the top of a noise barrier was suggested. For this, the authors have considered sound power flow around the device and sound pressure levels for the far field area. To estimate the area effect behind the barrier, area average of noise pressure level difference divided by two area, upper and bellow the sight-line. Comparing the attenuation difference of these areas, the tendency of noise reduction effect was studied according to type of noise reducing devices. Compared with noise shielding efficiency of the devices that using equivalent height of a simple barrier calculated by the SoundPlan, the commercial environment noise simulation software.

  • PDF

Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(I) - Estimation by Sound Intensity - (방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(I) - 음향인텐시티에 의한 평가 -)

  • Kim, Chul-Hwan;Chang, Tae-Sun;Lee, Ki-Jung;Kang, Hee-Man;Lee, Soo-Il;Chang, Seo-Il;Kim, Bong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1053-1056
    • /
    • 2007
  • The acoustical performance of noise reducing devices installed on the top of a noise barrier were tested by small-scale outdoor tests. Noise measurements before and after installation of the devices were carried out using sound intensity methods. It is well known that the sound intensity method can specify the strength and directivity of sound, and it is convenient to consider the feature of sound around a noise barrier. The noise reduction effect of each edge device was evaluated using the difference between the input and output sound power levels calculated from sound intensities. It was investigated that each device had different efficiency in the shadow zone, while there was no significant difference between edge devices in the illuminated zone.

  • PDF

Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(2) - Estimation by Sound Pressure Level - (방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(2) - 음압레벨에 의한 평가 -)

  • Kim, Chul-Hwan;Chang, Tae-Sun;Lee, Ki-Jung;Kim, Dong-Joon;Jeong, Tae-Ryang;Chang, Seo-Il;Kim, Bong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1125-1128
    • /
    • 2007
  • In order to improve the acoustic performance of a noise barrier without increasing its height, various type of acoustic devices are suggested but, there is no proper method to estimate the performance in Korea. For this, an outdoor test facility was established in Expressway and Transportation Technology Institute(ETTI) of Korea Expressway Corporation for testing the acoustical performance of noise reducing devices installed on the top of a noise barrier. Noise measurements before and after installation of the noise reducing devices were carried out by using sound pressure level for long distance range from the barrier, from 10m to 40m. For considering the directivity effects of noise reducing devices, multivariate regression analysis was attempted.

  • PDF

A Study on the Test Method for Noise Reduction Devices Installed on the Noise Barriers (방음벽 상단 소음저감장치의 감음성능 평가방법 연구)

  • Kim, Chul-Hwan;Chang, Tae-Sun;Kim, Deuk-Sung;Kim, Dong-Jun;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.791-796
    • /
    • 2010
  • Installing noise barriers is the most common method for reducing the highway traffic noise to the road side residential area. After the report about edge potential concept of a noise barrier, various types of noise reducing devices(NRDs) called "noise reducers" have been suggested for getting more shielding effect on the top of highway noise barriers. But, it has been doubtful about effect of the NRDs in field because there was no appropriate and unified method to estimate the acoustic performance by using field measurement of the NRDs in Korea. In this study, the authors have considered to setup a practical method to test and estimate the acoustic performance of NRDs. For eliminating the noise reduction effect of the NRDs height itself, the source and measuring points are adjusted as highly as the NRDs height. For the frequency weighting in the estimation of the NRDs effect, the highway noise spectra were measured at asphalt and concrete road side and then averaged for a unit spectral parameter.

Prediction of the Effect of Quiet Pavement on Reducing Barrier Height (저소음 포장도로 시공에 따른 방음벽 높이 저감효과 예측)

  • Yang, Hong-Seok;Cho, Hyun-Min;Jeong, Jong-Seok;Kim, Myung-Jun
    • International Journal of Highway Engineering
    • /
    • v.18 no.5
    • /
    • pp.31-37
    • /
    • 2016
  • PURPOSES : The purpose of this study is to evaluate the effect of the quiet pavement on reducing a barrier height by using a prediction tool called SoundPLAN. METHODS : Firstly, the prediction was carried out to evaluate the difference in the maximum noise level at a building facade between the normal and the quiet pavements without a barrier. After calculating the noise reduction effect by the quiet pavement, a comparable barrier height to obtain the same noise reduction effect with it was predicted according to designable factors including road-building distance(10 m, 20 m, 40 m) and road-barrier distance(5 m, 10 m, 20 m, 30 m). RESULTS : The result showed that within the considered designable factors, the maximum barrier height was 37 m, 52 m, and 55 m to have the same noise reduction effect by the quiet pavement reducing 1 dBA, 3 dBA, and 5 dBA, respectively. It was evaluated that the barrier height increased with the increase of the road-building and road-barrier distances. To simulate the real situation in urban areas and to evaluate the combined effect of the normal/quiet pavement and barrier, the barrier height was fixed as 6 m. It was predicted that the noise level would reduce to as low as 0.2 dBA by the combination of normal pavement and barrier. On the other hand, the combination of the quiet pavement and barrier reduced 1.2 dBA, 3.2 dBA, and 5.2 dBA, respectively, for quiet pavement reducing 1 dBA, 3 dBA, and 5 dBA. CONCLUSIONS : A guideline needs to be suggested to select appropriate noise abatement schemes by considering factors such as the roadbuilding and road-barrier distances.

Noise Reduction Effect of an Air Bubble Layer on an Infinite Flat Plate Considering the Noise of Multi-bubbles (다중기포 발생소음을 고려한 무한평판 주위에 형성된 수중 기포층의 방사소음 감소 효과)

  • Kim, Jong-Chul;Heo, Bo-Hyun;Cho, Dae-Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1222-1230
    • /
    • 2009
  • A theoretical model was developed to compute the effect of a bubble layer in reducing the radiation noise generated by a force applied on an infinite flat plate considering the noise of multi-bubbles. Using the model, the effectiveness of a bubble layer in reducing the structure-borne noise of the plate was evaluated to consider various parameters such as the source noise levels, the thickness of bubble layers, the volume fractions and the frequency characteristics of bubbly fluids. Considering the noise of multi-bubbles, the actual reduction effect of radiation noise using a bubble layer was expected in cases of high source levels, high volume fractions of bubbles and large thickness of the bubble layer above the resonance frequency of the bubble layer. Accordingly, it is recommended that the thickness of a bubble layer, the source noise level and the characteristics of bubbly fluids should be optimized cautiously to maximize noise reduction effects.

Influence of Exposed Aggregate Texturing on the Reducing Traffic Noise Emission

  • Han-Young, Moon;Sang-Wook, Ha;Eun-Cheol, Yang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1067-1070
    • /
    • 2003
  • The effects of traffic noise are a serious concern in many urban communities throughout the world. Environmental noise at high intensities directly affects human health by causing hearing loss and indirectly affects human welfare by interfering with sleep, thought, and conversation. In general, portland cement concrete(PCC) pavement is known to create more noise than asphaltic surfaces though it has the advantage of durability and superior surface. However, the results of preliminary laboratory test showed exposed aggregate concrete(EAC) have an effect on reducing traffic noise. Based on the laboratory test, pilot construction of exposed aggregate concrete was performed and series of in-situ measurements were conducted for noise analysis which included the pass-by noise measurement and the close-proximity method. Conclusively, It is expected that tire/pavement noise which is represented much noise levels at higher frequencies would be significantly reduced on special textures of pavement as like exposed aggregate concrete.

  • PDF

Characteristics of Reducing the Water-drainage Noise of Toilet-bowl According to the Composition of Water Drainage Piping Materials of the Bathrooms of Apartment Housing (공동주택 욕실 배수배관 자재 구성에 따른 양변기 배수소음 저감 특성)

  • Jeong, A-Yeong;Kim, Kyoung-woo;Shin, Hye-kyung;Yang, Kwan-seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.114-120
    • /
    • 2017
  • Water supply and drainage noise in the bathroom is recognized as one of the main noises, along with the floor-impact sounds, in apartment housings. Recently, to solve such noise issues, a new construction method of installing the piping on the slab has been adopted. rather than the traditional method of penetrating the piping through the slab between the upper and the lower bathrooms. However, this new method has limitations due to high costs and constructional difficulties. Therefore, this study was conducted to develop noise reducing piping and elbows, where the noise can be reduced simply by replacing the existing pipings. The noise level was measured in a laboratory by installing the horizontal drainage piping (three types) and the elbows (three types) developed in this study. The results showed that the horizontal pipings reduced the noise level in LAmax by 0.3 dB(A)~1.0 dB(A), as compared to the existing pipings (VG2), indicating an insignificant noise reduction effect. The elbow reduced the noise level in LAmax by 5.5 dB(A) ~ 11.5 dB(A), as compared to the existing elbow (DRF elbow), with the result of reducing the noise level at all frequencies evenly. Consequently, it was shown that using the elbows is more effective in reducing the water-drainage noise from the toilet than using the horizontal pipings.