• Title/Summary/Keyword: Noise Pollution Level

Search Result 72, Processing Time 0.03 seconds

A Survey on Elementary Students' Perceptions about Global and Local Environmental Issues (초등학생의 전지구적 및 지역적 환경 문제에 대한 인식 조사)

  • Jang, Bo-Ra;So, Keum-Hyun;Shim, Kew-Cheol;Yeau, Sung-Hee
    • Journal of Korean Elementary Science Education
    • /
    • v.28 no.2
    • /
    • pp.142-153
    • /
    • 2009
  • The purpose of this study was to survey primary students' perception of the global and local environmental issues. The subjects were 853 fifth primary students in Seoul, Busan, Daejeon, Anyang, Gimpo and Cheongju. The results were as follows: First, the perception level of the global environmental issues were global warming (M=3.99), drinking-water pollution (M=3.92), acid rain (M=3.77), yellow dust (M=3.66), ozone depletion (M=3.57), deforestation in tropical areas (M=3.52), desertification (M=3.36), biodiversity (M=3.40) and their perception level of local environmental issues were waste disposal (M=3.87), air pollution (M=3.74), bad smell (M=3.70), noise (M=3.61), river pollution (M=3.57), soil pollution (M=3.44). Second, it was shown that the metropolitan students' perception levels of environmental issues were higher than the non-metropolitan students'. There wasn't a significant difference in the perception levels of two scale environmental issues and characteristics for sex (p>.05). Third, the result of analyzing on the effects between characteristics was that the factors like 'environmental interest' and 'impact on personal life' had a strong influence on the 'behavior will' to solve the global environmental issues, and 'environmental interest' and 'personal knowledge' had a strong influence on the 'behavior will' to solve the local environmental issues. Fourth, the result of analyzing on the characteristics according to the types of the environmental issues showed that 'personal knowledge', 'environmental interest' and 'behavior will' were high in the global environmental issues (p<.01) and 'virtual contamination', 'human responsibility' and 'impact on personal life' were high in the local environmental issues (p<.05).

  • PDF

An Effect of Revolutions Per Minute (r.p.m) in the Noise Characteristics (기계소(機械騷) 음(音)과 회전(回轉) 속도(速度))

  • Cha, Bong-Suk
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.94-101
    • /
    • 1977
  • Noise pollution, both in the environment and in the workplace, has been recognized as a major health hazard -one that can impair not only a person's hearing but also his physical and mental well-being. As industrialization progresses, the prevalence rate of occupational diseases is increasing, especially hearing loss, which has the highest prevalence rate among the occupational diseases. The major cause of noise is the construction of various large industries without any regulation of noise sources. Therefor, we must establish an enactment to control mechanical noise sources. as soon as possible. For the purpose of controlling the noise source, we must have exact data about such things as the sound level, the frequency of the peak sound and the revolutions per minute (r.p.m.) of the machine (a measure of the power of its motor). This study was undertaken in order to define the noise characteristics, the power of the machine's motor, the change of the sound level and the peak sound as the r.p.m. increases, and the permissible exposure time. The sample size of this study was 74 machines at 11 plants in 6 industries. The results are as follows; 1. The breakdown of the types of mechanical noise noted was : 63.6% continuous normal sound, 26.9% intermittent sound, 4.7% continuous repeating sound and 4.6% impulsive sound. 2. With respect to the type of industry, the overall sound level was the highest in the mechanical industry, with $103.8{\pm}2.8dB(A)$, and lowest in the textile industry, with $89.2{\pm}1.43dB(A)$. 3. With respect to the type of machine, the highest sound level was 124 dB(A) caused by Gauzing(II), in the mechanical industry, and the lowest was 76 dB(A) caused by Attachment (Jup Chack) (I) in the timber industry. 4. The shortest permissible exposure time to Gauzing(II) in the mechanical industry was less than 15 minutes. 5. Among 74 machines, 68.2% of the peak sound was situated in the high frequency range (52.7% at 2 KHz, 4.1% at 4 KHz and 1.4% at 8 KHz). 41.8% of the peak sound was in the middle frequency range (4.1% at 250Hz, 14.8% at 500Hz and 22.9% at 1KHz). 6. If one machine had two motors or more, the peak sound was shifted to the low frequency range. 7. As the r.p.m. increased, the overall and peak sound levels were increased without any change of the frequency of the peak sound. 8. Whenever the machines had the same kind and the same r.p.m., the overall and peak sounds were changed by the physicochemical characteristics of the raw materials and the management.

  • PDF

Study on Traffic Noise in Residential Area Near Urban Expressways (주거지역 인접 도시고속도로 교통소음 분석)

  • Kim, Jong-Hyuk;Kim, Hong-Gil;Kim, Jung-Sik
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.2
    • /
    • pp.79-89
    • /
    • 2012
  • Noise pollution on the residential areas adjacent to urban expressway is a very severe situation. There has been a significant increases in the number of residential areas near urban expressway, and the quality of life in such areas is being degraded due to increased traffic volume and speed. In this study, several factors such as traffic volume, speed, and distance from noise source, etc. that affect the noise level were investigated for the residential areas near urban expressway. A correlation and regression model was built to examine the relationship between such traffic factors and noise. The study result found that traffic volume had a closer relationship with noise than speed had. Therefore, to decrease road traffic noise, it is more imperative to control traffic volume than traffic speed.

The Perception of Residential Problems and Satisfaction of Korean Elderly in Urban Area (노인이 인지하는 주거문제와 주거만족도에 관한연구)

  • 곽인숙
    • Journal of Families and Better Life
    • /
    • v.16 no.3
    • /
    • pp.95-110
    • /
    • 1998
  • The purpose of this study was to analyze contributing factors to the perception of elderly's residential problems and satisfaction. The sample in this study consisted of 556 elderly husband and wives over 55 years old living in Seoul Daejeon Jeonju and Daegu. Statistics employed for the analysis were frequencies means one-way anova and umltiple regression analysis. The results could be summarized as follows. Deficiency of privacy was the worst status and then noise and air-pollution and the level of facilties in residential space. And the perception of residential problems could be affected by age health the type of family the number of family the ownership of house the type of house location and the economic status The significant variable positively related to the residential satisfaction were the healthy conditon of eldely ownership of house living in multihousing the perception of privacy and high level of facilities in the house.

  • PDF

The Assessment of Survey on the Indoor Air Quality at Schools in Korea (국내 일부학교 건축물의 실내공기질 평가)

  • Sohn Jong-Ryeul;Roh Young-Man;Son Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

Overview of anthropogenic underwater sound effects and sound exposure criteria on fishes (어류에 미치는 인위적인 수중소음 영향과 피해기준에 대한 고찰)

  • PARK, Jihyun;YOON, Jong-Rak
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.1
    • /
    • pp.19-40
    • /
    • 2017
  • A scientific and objective sound exposure criterion for underwater sound damage on fish has been required since there has been many disputes between an underwater sound maker and a fish damage receiver. The existing criteria are still incomplete scientifically owing to a degree of variability of underwater sounds, diversity of fish hearing sensitivity and damage types, etc. This study reviews existing studies on a hearing mechanism of fish species, manmade underwater sound characteristics and sound exposure assessment parameters, and recent sound exposure criteria. A governing equation for damage coverage estimation and damage coverage dependency on sound source level, ambient noise and transmission loss are also reviewed and interpreted based on sound exposure environments. The foreign and Korean (National Environmental Dispute Medication Commission) criteria are reviewed and compared based on scientific aspects. In addition, the deficit and limit of Korean criteria are presented. The objective of this study is to give a direction for related researches and legislation of sound exposure criteria on fish.

A Study on the Application of Human Factors to the Introduction of PAV & UAM

  • Ahn, Kyung Su;Jeong, Won Kyong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.28 no.4
    • /
    • pp.171-175
    • /
    • 2020
  • The present and future cities are expanding, and the noise and environmental pollution in cities are getting worse day by day, causing saturation of road and subway traffic. As a result, citizens are spending a great deal of time and money. The use of the sky as a measure to solve this problem has become a reality. However, airplanes that require airstrips and noisy helicopters are difficult to use in cities. As a solution, PAVs and UAMs that generate low noise and enable vertical takeoff and landing using electric energy, motor, hybrid, and hydrogen energy, are attracting attention, with its practicality being promoted in many countries. The development of urban environment and technology has led to the emergence of Personal Air Vehicle (PAV), Vertical Takeoff and Landing (eVTOL), and Urban Air Mobility (UAM) for shipping. Though currently at the level of testing, general commercialization of these air transport means is expected in the next five to fifteen years. This study suggests a plan on the application of human factors to the introduction of PAV and UAM.

Association between Environmental Perception and Subjective Health Status of Older Adults (노인의 환경인식과 주관적 건강과의 관련성)

  • Lee, Sungeun
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.391-396
    • /
    • 2018
  • Objectives: The purpose of this study is to examine the level of community environmental perception of older adults and to identify the association between environmental perception and subjective health status among older persons. Methods: Analyses are based on data from Statistics Korea 2016 Social Survey. This study analyzed a total of 8,193 older adults aged 65 and over, and examined the association between environmental perception on air, water, soil, noise and vibration, and subjective health status using multiple regression analysis. Results: Study findings shown that environmental perception on water and soil had significant association with subjective health status of older adults. Specifically, older adults reported worse health status when they had more negative perceptions of water and soil environments in their communities. Conclusions: Results of this study suggested that efforts to enhance safety of drinking water and soil environments, and continuous research to identify relationship between environment and elderly health shoud be needed.

A Study on Public Nuisance in Seoul, Pusan and Daegu Cities Part I. Survey on Air Pollution and Noise Level (공해(公害)에 관(關)한 조사연구(調査硏究) 제일편(第一編) : 서울, 부산(釜山), 대구(大邱) 지역(地域)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 비교조사(比較調査) 연구(硏究))

  • Cha, Chul-Hwan;Shin, Young-Soo;Lee, Young-Il;Cho, Kwang-Soo;Choo, Chong-Yoo;Kim, Kyo-Sung;Choi, Dug-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.4 no.1
    • /
    • pp.41-64
    • /
    • 1971
  • During the period from July 1st to the end of November 1970, a survey on air pollution and noise level was made in Seoul, Pusan and Taegu, the three largest cities in Korea. Each city was divided into 4-6 areas; the industrial area, the semi-industrial area, the commercial area, the residential area, the park area and the downtown area. Thirty eight sites were selected from each area. A. Method of Measurement : Dustfall was measured by the Deposit Gauge Method, sulfur oxides by $PbO_2$ cylinder method, suspended particles by the Digital Dust Indicator, Sulfur dioxide ($SO_2$) and Carbon Monoxide (CO) by the MSA & Kitakawa Detector and the noise levels by Rion Sound Survey meter. B. Results: 1. The mean value of dustfall in 3 cities was $30.42ton/km^2/month$, ranging from 8.69 to 95.44. 2. The mean values of dustfall by city were $33.17ton/km^2/month$ in Seoul, 32.11 in Pusan and 25.97 in Taegu. 3. The mean values of dustfall showed a trend of decreasing order of semi-industrial area, downtown area, industrial area, commercial area, residential area, and park area. 4. The mean value of dustfall in Seoul by area were $52.32ton/km^2/month$ in downtown, 50.54 in semi-industrial area, 40.37 in industrial area, 24,19 in commercial area, 16.25 in park area and 15.39 in residential area in order of concentration. 5. The mean values of dustfall in Pusan by area were $48.27ton/km^2/month$ in semi-industrial area, 36.68 in industrial area 25.31 in commercial area, and 18.19 in residential area. 6. The mean values of dustfall in Taegu by area were $36.46ton/km^2/month$ in downtown area, 33.52 in industrial area, 20.37 in commercial area and 13.55 in residential area. 7. The mean values of sulfur oxides in 3 cities were $1.52mg\;SO_3/day/100cm^2\;PbO_2$, ranging from 0.32 to 4.72. 8. The mean values of sulfur oxides by city were $1.89mg\;SO_3/day/100cm^2\;PbO_2$ in Pusan, 1.64 in Seoul and 1.21 in Taegu. 9. The mean values of sulfur oxides by area in 3 cities were $2.16mg\;SO_3/day/100cm^2\;PbO_2$ in industrial area, 1.69 in semi-industrial area, 1.50 in commercial area, 1.48 in downtown area, 1.32 in residential area and 0.94 in the park area, respectively. 10. The monthly mean values of sulfur oxides contents showed a steady increase from July reaching a peak in November. 11. The mean values of suspended particles was $2.89mg/m^3$, ranging from 1.15 to 5.27. 12. The mean values of suspended particles by city were $3.14mg/m^3$ in Seoul, 2.79 in Taegu and 2.25 in Pusan. 13. The mean values of noise level in 3 cities was 71.3 phon, ranging from 49 to 99 phon. 14. The mean values of noise level by city were 73 phon in Seoul, 72 in Pusan, and 69 in Taegu in that order. 15. The mean values of noise level by area in 3 cities showed a decrease in the order of the downtown area, commercial area, industrial area and semi-industrial area, park area and residential area. 16. The comparison of the noise levels by area in 3 cities indicated that the highest level was detected in the downtown area in Seoul and Taegu and in the industrial area in Pusan. 17. The daily average concentration of sulfur dioxides ($SO_2$) in 3 cities was 0.081 ppm, ranging from 0.004 to 0.196. 18. The daily average concentrations of sulfur dioxides by city were 0.092 ppm in Seoul, 0.089 in Pusan and 0.062 in Taegu in that order. 19. The weekly average concentration of carbon monoxides(CO) was 27.59 ppm. 20. The daily average concentrations of carbon monoxides by city were 33.37 ppm. in Seoul, 25.76 in Pusan and 23.65 in Taegu in that order. 21. The concentration of $SO_2$ and CO reaches a peak from 6 p. m. to 8 p. m. 22. About 3 times probably the daily average concentration of CO could be detected in the downtown area probably due to heavy traffic emission in comparison with that in the industial area. 23. As for daily variation of the concentration of $SO_2$ and CO it was found that the concentration maintains relatively higher value during weekdays in the industrial area and on the first part of the week in the downtown area.

  • PDF

A Study on Public Nuisance in Kwangju City (Survey on Air Pollution and Noise Level) (공해(公害)에 관(關)한 조사연구(調査硏究) -광주시(光州市)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 조사연구(調査硏究)-)

  • Chung, Yo-Han;Kim, Kil-Wng;Moon, Jae-Kyu;Jhoo, Heung-Kyu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 1972
  • During the period from June 1st 1971 to November 30 th 1971, studies on air pollution were made in Kwangju city. The city was divided into 6 areas; the downtown area, the semi-downtown area, the heavy traffic area, the commercial area, the residential area, the park area, 13 surveying sites were selected each representing the characteristics of the area. The Measurement methods which were used are described below. Sulfur oxides were measured by $PbO_2$ cylinder method, sulfur dioxides ($SO_2$) and carbon monoxide (CO) by the MSA & Kitakwa detector, dustfall by the Deposit gauge method, and the noise levels by the Kanomax soundlevel meter. The results obtained are as follows: 1. The mean value of sulfur oxides in Kwangju city was $1.16mg\;SO_3/day/100cm^2\;PbO_2$, ranging from $0.45mg\;SO_3/day/100cm^2\;PbO_2$ to $3.10mg\;SO_3/day/100cm^2\;PbO_2$. 2. The mean values of sulfur oxides according to its specific area in the city were $1.45mg\;SO_3/day/100cm^2\;PbO_2$ in heavy traffic area, 1.36 in downtown area, 1.23 in semi-downtown area, 1.11 in commercial area, 0.96 in residential area, and 1.07 in park area, respectively. 3. The average concentration of sulfur dioxide was 0.063 ppm from 2 to 5 P.M in Kwangju city. 4. The average concentrations of sulfur dioxides according to its specific area, from 2 to 5 P.M, in the city were 0.084 ppm in heavy traffic area & downtown area, 0.067 in commercial area, 0.053 in semi-downtown area, 0.052 in residential area, and 0.036 in park area. 5. The average concentration of carbon monoxide was 22.3 ppm from 2 to 5 P.M, in Kwangju city. 6. The average concentrations of carbon monoxide according to its specific area, from 2 to 5 P.M, in the city were 27.0 ppm in downtown area, 26.3 in semi-downtown area, 23.0 in heavy traffic area, 21.7 in commercial area, 20.0 in residential arera, and 17.6 in park area. 7. The mean value of dusifall in Kwangju city was $29.28ton/km^2/month$, ranging from $9.85ton/km^2/month$ to $66.34ton/km^2/month$. 8. The mean values of dustfall according to its specific area in the city were $50.37ton/km^2/month$ in semi-downtown area, 42.76 in heavy traffic area, 34.67 in downtown area, 17.77 in commercial area, 14.40 in park area, and 14.76 in residential area. 9. The mean values of the soluble dust in Kwangju city was $10.23ton/Km^2/month$ and that of the insoluble dust was $19.05ton/Km^2/month$. 10. The mean value of noise level in Kwangju city was 62 phon, ranging from 37 phon to 88 phon. 11. The mean values of noise level according to its specific area in the city were 76 phon in heavy traffic area, 67 in semi-downtown area, 64 in downtown area, 59 in commercial area, 52 in part area, and 50 in residential area.

  • PDF